CWE NO 2 DELHI CANTT-10
HQ CWE NO 2 DELHI CANTT-10
REPAIR / REPLACEMENT AND MAINT OF HT EXTERNAL ELECT NETWORK AND OTHER CONNECTED ITEMS AT SALARIA OFFRS ENCLAVE AT DWARKA UNDER GE (WEST) DELHI CANTT-10
2024_MES_641232_1
CWE/WEST/TOKEN-34/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE WEST DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE WEST DELHI CANTT-10
₹40,000
30 Apr 2024
7 Feb 2024
11 Mar 2024
7 Feb 2024
8 Mar 2024
23 Feb 2024
Amount
Maintenance,Servicing,cleaning, Vaccum circuit breaker unit 11KV of capacity 630A, make CG,racking out from panel / opening of the VCB for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing ,greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and Calibration and testing of 11KV VCBs indoor type along with control panel and control wiring, protection system and Calibration of relays by injecting high voltage/ current in primary / secondary side as required for check the triping mechanism complete including rectification of defects noticed complete all as specified and directed. (Note:- The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch 'A' as supply only.)
Supply only following spares in repairs suitable for 11KV HT VCB of capacity 630A
Door Limit switch
Tripping coil assembly
Closing coil assembly
Anti condensation space heater
Thermostat
Test and Service Limit Switch
Vacuum Interrupter
S&F in repair differential relay CT 11KV single phase out door oil cooled CT of ratio 800/400/5 -5 amps class 1.0 - 5P 10 burden 15 VA insulation level 70KV/170 KV as per IS : 2705 including check wiring from CT to Defferencial relay complete all as specified and directed.
Dehydration/filtration of transformer oil by means centrifuging machine electrically operated at site of installation of transformer in running condition including testing of transformer oil before and after filtration by means of oil testing machine, keeping the electrodes at 2.5 mm gap and to achieve die electric strength of filtered oil 50 KV and above complete all as specified and directed.
Supply and topping up/replaced transformer oil conforming to IS : 335 and to withstand dielectric strength of 60 KV (when tested with 2.5 mm Gap electrode) complete all as specified and directed.
Supplying, laying and commissioning of HT XLPE cables, insulated, screened, PVC bedded, galvanized steel strip armoured, earthed, electric power cable with Aluminium conductor, 11 KV grade, 3 Core, 240 Sq.mm cross sectional area laid in trenches / fixed on poles including taking up/down old cables complete all as specified and as directed. Note: Earth work,excavation, cable covers and sand cushioning shall be measured and paid separately.
Material and Labour for heat shrinkable HT, 11 KV cable straight through joint suitable for 11 KV, 3 Phase, AC, 50 Hz, 3 Core, Size of 50 to 95 Sq.mm XLPE Cable including jointing materials, including taking down old unserviceable joints etc complete all as specified and as directed.
Material and Labour for heat shrinkable HT, 11 KV cable straight through joint suitable for 11 KV, 3 Phase, AC, 50 Hz, 3 Core, size of 120 to 185 Sq.mm XLPE Cable including jointing materials, including taking down old unserviceable joints etc complete all as specified and as directed.
Material and Labour for heat shrinkable HT, 11 KV cable straight through joint suitable for 11 KV, 3 Phase, AC, 50 Hz, 3 Core, size of 240 to 300 Sq.mm XLPE Cable including jointing materials, including taking down old unserviceable joints etc complete all as specified and as directed.
M & L for Locating electrical faults and repair work in HT/LT side of the transformer, VCB whenever any fault arises at Salaria officers Enclave area, making complete supply system functional dully rectifying and repair work complete all as specified and directed. Note: (a) Whenever any breakdown reported the Contractor will have to take immediate action and send skilled Technician immediately on site. (b) Any parts required to be replaced during repair work shall be measured and paid for separately.
S & F in repair of High voltage insulation mats (ISI Marked) as per IS-15652 of size 2m X 1 m and 2.5 mm thick for voltage upto 11 KV complete all as specified and directed.
Supply and fixing cable route indicator for HT UG Cable of 11000 Volts bolted with 40 x 6 mm flat iron member of height 0.60 mtr, and 80 mm dia Cl plate embedded in PCC 1: 3: 6 type C2 of size 20 x 20 x 30 cm block complete all as specified and directed.
M&L for crushed stone aggregate for filling in floors or pavings of Gauge 40 to 63 mm, at TFR, deposited, spread and levelled in layers not exc. 150mm thick, rammed to a True Surface, complete all as specified and as directed.
Preparation of old painted surface removing of rust from any kind of steel surface, clamps, TFR fencing etc for of any description and repainting by 1st quality Synthetic enameled paint 2 coat over a coat of primer complete all as specified and directed
M&L for dismantling/preparing base for PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) on feeder pillar foundations/pole foundation in any shape of foundations, filling of mass concrete making complete existing shape complete all as specified and directed.
M&L for replacement of air breather with filled silica gel suitable for any make of transformer rating up to 630 KVA mounted on plinth including taking out old u/s one complete all as directed
M&L for maintenance of earthings of installations like cleaning of earth pits, treatment of earthing by pouring salt water, replacement of perished wire mesh, unserviceable funnel and repair works like patch works to the PCC chambers and RCC cover with cement mortar 1: 4 all as directed.
M&L for replacement of battery bank for VCB as per existing capacity single phase including taking out old u/s one complete all as directed.
M&L for replacement of Cable end protector HT side for TFR end cables complete including taking out old u/s one complete all as directed.
Periodical servicing to 11KV HT RMU (3 ways) any type make- Crompton Greaves model Sabre complete including the following:- (a) Disconnecting the 11 KV line from RMU. (b) Opening the RMU and replacement the unserviceable part as required at site. (c) Checking of mechanical system for proper functioning of upward/downward or clock wise and anty clock wise movement of breaker. (d) Cleaning & servicing the fixed/ moving contact, busbar, cable boots with the CTC solution and greasing/oiling the parts where required or as directed. (e) Tighten the all loose parts and testing complete as directed by EIC. * Repair the door/lock incl welding and painting and replacement of lock/handle Note- (i) Replacing new items shall be included in the quoted rates. (ii) Other part which is not included but required for functioning of equipment is included in the quoted rate. (iii) Remove the moisture from RMU by heating (iv) The above job to be carried out by engineer of authorized dealer/service centre of concerned manufacturer. (vii) Painting with the approved color after preparation of old surface as directed.
M&L for replacement of Capacitor bank for capacitor panel of capacity 25 KVAR complete including taking out old u/s one complete all as directed.
M&L for replacement of Capacitor bank for capacitor panel of capacity 15 KVAR complete including taking out old u/s one complete all as directed
M&L for replacement of Capacitor bank for capacitor panel of capacity 10 KVAR complete including taking out old u/s one complete all as directed.
M&L for replacement of Capacitor bank for capacitor panel of capacity 5 KVAR complete including taking out old u/s one complete all as directed.
M&L for excavation in trenches in soft soil n.exc 1.5m wide and n.exc 1.5m in depth for laying of cables/pole etc setting out trimming the site forming bottom surface to required level complete all as specified and directed.
M&L for returning filling in-trenches including spreading leveling watering and well Cum ramming in layers with soft/loose/dense soil n.exc 25 cm thick in each layer of soil complete all as specified and directed.
M&L for removing/excavated soil to a distance n.exc 50 Mtr and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed.
M&L for sand cushioning with a layer of sand 23 cm thick (8 cm under and 15 cm above the cable) in trenches complete all as specified and as directed. Note:- Compacted thickness of sand i.e. 18 cm shall be measured and paid only.
M&L for fixing old serviceable un-reinforced precast concrete cable covers for cable protection of class LV type 1 flat of size 250 x150 x 40 mm complete all as specified and directed.
Supply, Installation, Testing & Commissioning of RTU panel in repair with all necessary spares for installation on main incoming panels at Salaria enclave. The said RTU panel must be capable of acquiring the data from various relays/ meters/ breakers/hard- points, etc., conditioning data for transmitting, transferring data through RTU to the server. Also, the unit should be able to perform bidirectional communication for future use. The system should be mounted in a panel of size 300mm x 300mm x 200mm (minimum) fabricated from 1.6mm thick CRCA sheet and must be powder coated. It shall be installed at site and, and shall be consisting of following:
Supply, Installation, Testing & Commissioning of RTU panel in repair with all necessary spares for installation on 3 Nos. outgoing panels at Salaria enclave. The said RTU panel must be capable of acquiring the data from various relays/ meters/ breakers/hard- points, etc., conditioning data for transmitting, transferring data through RTU to the server. Also, the unit should be able to perform bidirectional communication for future use. The system should be mounted in a panel of size 300mm x 300mm x 200mm (minimum) fabricated from 1.6mm thick CRCA sheet and must be powder coated. It shall be installed at site and, and shall be consisting of following:
Supply, Installation, Testing & Commissioning of multifunction meters in repair with RS485 for mounting on HT panels (replacing analog meters). The meter shall be of acc cl 1.0 and shall be able to record V, A, KW, KWh, PF, F with all wiring cabling, cutting of cabinets, etc. Make: Schneider, ABB, Socomec
Supply, installation, testing and commissioning in repair of a central station having computer processor of min 2Ghz along with the enclosure. The processor must be Processor- 7th gen intel Core TM i5 processor and 16GB DDR4 RAM 2400MHz or higher with Solid State Drive 512GB Hard Drive. Along with NVDIA/ GeForce Graphic Cards of 4GB and screen monitor of 27 inches for the SCADA work station system. Complete all as specified and directed. Must be accompanied by all peripherals such as mouse, keyboard, etc. with dedicated UPS supply having 10 minutes of backup. The central system software shall comply to below specifications: a) Must have user customizable dashboards and SLD (without any coding/ scripting). Dashboards shall be enabled with SVG based mimics only (PNG, JPEG images for functional mimics shall not be allowed) b) Reporting must be user-configurable and changeable. Utility like billing reports must be supported. c) Multi-site data viewing within same interface without any physical cable connection of sites to single website d) System must be accessible over internet and must have adequate security with dual factor authentication with username/ password along with OTP on email. e) All device communication with the server must be secured using TLS/SSL encryption. Central System must not support non- secure connections. f) Periodic reporting shall be enabled according to the format decided by the engineer-in-charge. All runtime/ development licenses must be included in the above for creation and maintenance of the system. It shall have the following functionalities.
(1) The central system software will report online trend for monitoring and should be capable of controlling devices. It should have all basic functionalities such as monitoring, control, historian (For trend analysis), alarm generation, and reporting. (2) The software with various reporting options and can store minimum 12 months of data. (3) The software have bidirectional operation on at least on Modbus DNP3, IEC61850, MQTT protocols and shall have more than 1500 tags. It must support SVG and PNG formats of assets.
Supply installation and commissioning in repair of RS 485 Communication cable, two pairs stranded copper, (7*32) tinned copper conductors, polyethylene insulation, twister pairs, aluminium/Polyster 100% coverage, Tinned copper braid shield 90% coverage, 24 AWG strained tinned copper drain wire, armoured , PVC jacket with the following specifications: (i) Outer jacket : Polyvinyl Chloride, 0.34 in (ii) Conductor DCR: 24 Ω/1000ft (iii) Nominal outer shleid DCR: 2.2 Ω/100ft (iv) Nominal capacitance conductor to conductor: 12.8µF/ft (v) Nominal capacitance conductor to other conductor to shield: 23µF/ft (vi) Nominal characterstics impedence: 120 Ω (vii) Frequency : 1 Mhz (viii) Nominal insertion loss: 0.6 DB/100m
Supplying and fixing in repair of 6 Core 1.5 Sqmm multistrand copper cable PVC insulated, laid up together PVC inner sheathed, as required complete all as specified and directed. Make: Polycab, KEI, reputed (Note: Rates include Power cables to be laid as specified with GI/PVC pipe protection whereever deemed necessary) - If higher number of cores are required in proposed DDC/ panels; contractor must assume higher number of cores. No extra price will be paid
J V ENGINEERS / JAI SINGH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .