Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹9.7 L+₹64,250 (7.08%)Rejected-Finance 0 MADHUPUR SAKARDAHA MADHUPUR SAKARDAHA SARAON MADHUPUR SAKARDAHA ALLAHABAD UTTAR PRADESH 212502 | PRAYAGRAJ | UTTAR PRADESH | 212502 | L2 | Rejected-Finance Being Not Lowest |
Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
5 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Prabhat Kumar Singh, AGE (I)
AGE (I) Manauri Allahabad-212212
REPAIR / MAINT OF E/M INSTALATION ALLIED WORKS UNDER AGE(I) AF MANAURI
2020_MES_362794_1
8830/E8
Open Tender
Civil Works - Water Works
Item Rate
182 days
Manauri, Allahabad
Class E, cat b(ii)
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹19,600
Yes
13 Oct 2020
7 Aug 2020
7 Sept 2020
7 Aug 2020
5 Sept 2020
22 Aug 2020
60 days
Amount
Lowering / lifting taking up/ down as site to submersible pump motor set with column pipe and cable in any specification after removing /disconnecting all electric connection carefully from panel board, joint of heavy duty flanged column pipe in 150 mm bore dia , minimum length 50 Mtrs as site in 3 Mtrs pieces ,bolts nuts washers, rubber gaskets etc including S&F of nut, bolts , washer, rubber gasket in suitable to 150 mm flange joints etc with all other site required work for making functional to submersible pump motor set of capacity upto 40 HP complete all as directed. (Note : All required T&P shall be arrange by contractor.
De-coupling/dismantling the body of submersible motor carefully for removing to defective spares such burn out winding with insulating material, GM impeller, necking, bowl assembly, bushes , coupling, lock, sand cap , CI intermediate bowl, S/S pump shaft etc ,checking and segregating serviceability , for replacing of defective parts as above and re-assembling as same, testing ,commissioning after replacing/ repairing to defective spares capacity upto 40 HP complete all as directed. Note ; (i) Quoted rate shall be included transportation charges (if required) from site to workshop and back as same (ii) Repair, servicing, checking, machine work , facing /cutting, grinding, polishing etc other all other site work.
M&L for re-winding to burnt out winding of submersible motor body primary winding as same in existing size /gauge/ No of turns / qty of insulation etc using superior quality water proof copper insulated winding wire ISI marked original manufacturer and submersible copper cable in required length and size for making connection minimum 1.5 Mtrs long outside, re-assembling, full load testing, heating, drying, varnishing, overhauling, re-installation, commissioning, testing and connecting capacity upto 40 HP complete all as directed.. Note :-(i) Testing shall be given by contractor after lowering in bore well at site. (ii) Quoted rate shall be including all required work at site for making functional to pump motor set and cutting , removing to burned windings from the motor body etc all.
M&L for re-packing around the borewell to pea gravel of size 1.6 mm to 4 mm all around the casing, blind and strainer pipe in borewell to entire depth complete all as specified and directed. Note:- Volume of Pea gravel shall be measured as net in compact stacks prepared on leveled ground and recorded in MB before pouring in position, surplus qty shall be similarly measured to arrive at the actual qty incorporated in the work
M&L for development of bore well (having ductile cashing pipe in slotted and solid/ blind type arranged as per assembly layout in any size and specification etc) located at 24 ED AOR by compressed air of Air Compressor capacity of PSI 500 to 600 upto getting clear water with 15000 GPH discharged / output ,complete. Note : Quoted rate shall be deem to included cost for the following:- (a) Repair/ replacement to all type of damage caused during development and all other required T&P/ fuel / etc all. (b) Cost shall be paid after yield test upto existing discharged/ output. (c) Yield test shall be measured and paid separately under respective item of this schedule.
M&L for Yield testing of repaired tube well by means of electric driven pumping set of suitable capacity (The discharge shall be measured by providing orifice system of "v" notch fixed to steel tank of adequate capacity) getting discharged upto existed output complete all as specified and directed. Note : All required T&P with submersible pump set shall be arrange by contractor. (ii) Yield test shall be done in presences of accepting officer. The yield test report and water test report issued by Govt approved laboratory shall be submitted by contractor.
S&F in replacement to MS housing clamp made out of mild steel flat iron size 150x12mm, 70 CM long, suitable for 350 MM dia casing pipe with necessary 19mm dia MS bolts full threaded, nuts and washers 04 Nos with each clamp complete all as specified and directed.
S&F in replacement to MS Cap made out by 8mm thick MS plate suitable to covered the bore well 350mm dia having internal threads with welded iron handle 20 MM dia MS round bar, made to shape both side openable hinges arrangement cutting welding etc complete all as per existing and as directed. Note : Quoted rate shall be included all required work for replacement to existing at given site.
S&F in replacement cast Iron fittings ISI marked conform to IS 1538- 1993 for flanged or spigot socketed pipe such as connecting pieces, bends, tapers, tail pieces (single or double branch) any type and angle / radius and straight connecting piece suitable for upto 250 mm bore pipe complete all as specified and directed.
S&F in replacement Ductile iron fittings IS-9523 marked for flanged or spigot socketed pipe such as connecting pieces, bends, tapers, tail pieces (single or double branch) any type and angle / radius and straight connecting piece suitable for upto 250 mm bore pipe complete all as specified and directed.
S&F in replacement to cast iron pipe class ‘A’, ISI marked, flanged end or spigot and sockets end (as site required) vertically cast, bore of pipe 150 mm using for main rising conforming to IS 1536- 1976 with necessary bolts, nuts, washers and packing material and joints laid in trenches including painting in two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. Note:- (a) Quoted rate shall be deem to included cost of complete earthwork (excavation, returning filling, removal) and nut bolt washer with packing material etc as required. (b) Fittings shall be measured & paid separately under respective item of this schedule.
S&F in replacement to cast iron pipe class ‘A’, ISI marked, flanged end or spigot and sockets end (as site required) centrifugally cast, bore of pipe 100 MM conforming to IS 1536- 2001 with necessary bolts, nuts, washers and packing material and joints laid in trenches including painting in two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. Note:- (a) Quoted rate shall be deem to included cost of complete earthwork (excavation, returning filling, removal) and nut bolt washer with packing material etc as required. (b) Fittings shall be measured & paid separately under respective item of this schedule.
S&F in replacement ductile iron pipe class K-9, ISI marked, flanged end or spigot and sockets end with internal cement mortar lining and external zinc and bitumen coated, bore of pipe 150 MM conforming to IS 8329:2000 complete with MS bolts, nuts, washers and packing material and joints laid in trenches complete all as specified and directed. Note:-(a) Quoted rate shall be deem to included cost of complete earthwork (excavation, returning filling, removal) and nut bolt washer with packing material etc. (b) DI Fittings shall be measured & paid separately under respective item of this schedule.
S&F in replacement to cast iron non return valve / Reflux Valve PN-1.6 grade, for 150 MM dia bore of pipe including all jointing material such as nuts, bolts, washers, rubber gasket etc complete and as directed. Make ; Kirloskar / Vir or as specified in Appendix B to PS
Taking out to excavated material after excavation the surface with required T&P, cleaning the area by removing the vegetation /grass, stacking the old crushed stone /chequred tiles/ interlocking tiles, broken to hard standing /PCC work etc cleaning levelling preparing for re-surfacing the hard standing using by cement concrete / lay to inter locking tiles after filling & compacting of approved soil / sand in layer laid in complete area not less than 100 mm thick, spraying the anti grass treatment in complete area and proper levelling in water supply Installation area including removing from site and depositing not exc 50 Mtr apart from site complete all as specified and directed. Note: Approved soil shall be measured and paid separately under respective items of this schedule.
Supply, levelling, laying in layer, compacting, watering etc as per site requirement for filling purpose of approved fine soil obtained from outside MOD land and to laid in the MRS (Main receiving Station) switch yard duly watering, well rammed, compacted and levelled complete all as specified and directed. Note: Approved soil shall be measured at filling area after deduction of 10% bulkage for obtaining standard proctor density to optimum moisture condition.
Supply and filling broken/crushed stone boulder size 40 to 63 mm filling dry hand packed tightly laying in layers on ground surface in after excavation, removing, dressing, leveling, compact work etc all as per site requirement on existing ground surface of E/M installations complete all as specified and directed. Note:- Quoted unit rate shall be deemed to included cost required for earth work to prepare the surface for laying boulder in layers with compact work.
M&L for PCC (1:2:4) type C1 using 20mm graded stone aggregate as in benching, plinth foundation/ laying in layer as required thickness for hard standing in installation yard/ surface of cable trench etc including levelling etc as site required complete all as specified.
M&L for forming construction joint 30mm deep and 10mm wide filled with sealing compound grade ‘A’ complete all as directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling, sub base of floor and mass concrete complete all as specified and directed.
M&L for factory made 80mm thick M-40 grade machine pressed precast cement concrete interlocking paver block any shape and size colour glazed confirming to IS 15658- 2006 with grey cement and pigment concrete over 50mm thick sand cushioning including demolition and removing to old broken as same above complete all as specified. Note:- (a) 50mm thick sand cushioning shall be punned thickness (b) All exposed sides of interlocking paver block shall locked with PCC 12:4 type B1 using 20mm graded stone aggregate and PCC shall be measured & paid separarately under item No 18.
M&L for preventive maintenance/ overhauling / servicing /cleaning etc all for required to DG set capacity 400 KVA located in E/M installation including supply and replacement of fuel filter (primary and secondary all) oil filter, by pass filter packing material/ gaskets, high pressure GI fuel pipe with both end union ,bolt washer, cleaning to air cleaner with replacement of air cushion pad etc in original manufacture as per existing including cleaning to oil sump using Kerosene oil after drain out old unsv oil & testing all as directed Note: (i) Engine Oil shall be measured & paid separately under respective Items (ii) Quoted rate shall be deem to include time / tapper setting, repair to leakage etc all required work for making serviceable .
S&F in replacement radiator fan and water pump belt (both) suitable for 400 KVA DG Set specification all as per existing and directed. Make:- As per sample
Re-setting to AMF controller panel of DG set capacity 400 KVA (Make Kirloskar, model Green Power JAK ) by technical rep of OEM for microprocessor based fully configurable control unit relay LCD display phase voltage generating current ,all digital indication display parameter audio visual warning including supply and replacement to relay, connecting fuse time relay switch etc all in original manufacture existing specification etc with all minor spares and replacement of internal connection cable with copper lugs in existed size etc all other work required for making serviceable and testing all as specified & directed.
S&F in replacement to main head gaskets of DG set capacity 400 KVA made out by bronze pack material including opening and re-assemble to engine body by tech rep of OEM complete with testing on full load for one hour minimum etc all as specified and directed. Make:- As per sample
S&F in replacement water hose pipe of DG set capacity 400 KVA in existing specification and directed. Make:- As per sample
Taking down of radiator assembly complete of DG set capacity 400 KVA including cleaning, brazing and soldering to leakage water tubes cleaning to tube fens by compressed air and in side body by using chemical including re-fixing the same with required nut bolt washer radiator cap (as per existing) with supply and re-filling of coolant upto top level with half fulfill to air pressure reservoir tank , two coat of black heat shrinkable paint on metal body , required nut bolt washer and re-fixing as same, testing complete as directed . Note:- Quoted rate shall be included cost of transportation charge.
S&F in replacement of battery lead / cable for 180 AH 12 / 24 Volt copper conductor for PVC Insulated multi-stranded minimum 1.5 m long with both end heavy duty copper terminals & lugs (440/014 or equivalent) for 35 Sqmm or suitable to giving the start push for DG set 400 KVA capacity all as directed.
Supply & fixing in replacement of heavy duty battery terminals made by copper with nuts & bolts washer etc all as directed. Make:- As per Sample
Supply and re-filling upto indicating level 20 W 40 engine oil multi grade supplied in sealed container ISI marked. Make:- Servo / HP extra super/ Indian oil /Castrol
S&F in replacement of self-starter assembly 24 volts with mounting bracket suitable for 400 KVA DG set Make kirloskar Green Power India Model Jak Power in original manufacture Make REIL series R 50 type 400 rotation CW model DV 0027.11.0.00 Sr No 22 , 012K and all specification as per existing with connecting lead / cable one end thimbles and other Battery post terminal making all connections including testing with original warrant card issued by OEM complete all as specified and directed. Make:- As per Sample
S&F in replacement three pole power contactor type ML-12 current rating AC3 300 Amp and AC1 400 Amp range, 240 volt confirm to IS/ IEC 60947- 4-1 & IEC 60947 -4-1 size Fr -4, 2 NO+ 2 NC with other specification parameter all as per existing 400 KVA DG set Make Kirloskar including making connection complete as specified and directed. Make : L&T Model-SS91010 OR as per sample
Supply, connecting in replacement of acid lead maintenance free GP 115E31L type 12 volt 180 Ah heavy duty Generator set battery suitable for giving start backup to 125 KVA DG set initially charged with connecting copper multicore lead/ cable PVC insulated 1.5 mtr long one end fixed heavy duty copper terminal and other copper lugs with 36 months warranty minimum complete. Make:- Exide Model Xpress
Supply connecting in replacement of acid lead maintenance free 12 volt 150 Ah heavy duty Generator set battery suitable for giving start backup to 75KVA DG set initial charged with connecting copper multicore lead/ cable PVC insulated 1.5 mtr long one end fixed heavy duty copper terminal and other copper lugs with 36 months warranty minimum complete. Make ; Exide Model Xpress
S&F in replacement of water temperature gauge in original manufacture all existing specification suitable for 400 KVA Kirloskar make DG set complete as directed. Make:- As per sample
S&F in replacement of starting switch with keys / canopy locking in original manufacture all existing specification suitable for 400 KVA Kirloskar make DG set complete as directed . Make:- as per sample
S&F in replacement of asbestos rope for heat resistance fixing on exhaust pipe of 400 KVA DG set.
Dismantling and disconnecting to body engine and alternator separately of DG set capacity 400 KVA to removing the existing flywheel ring and supply, fixing with replacement as same suitable for alternator 400, KVA KG 354 S 2 , 556.5 Amps 1500 RPM in original by technical rep of OEM / authorized agency with re-assembling connecting making all connection , all other spares such as self-starter etc all complete with testing re-connecting etc all as site required and directed. Note : Quoted rate shall be included cost of all other required minor spares and work for making serviceable satisfactorily.
M&L for cleaning washing with casting soda mixed water removing all oil mixed wastage and scarping rubbing to old faded colour of DG set capacity 400 KVA complete body of engine alternator cabing both side after preparing to all including painting using paint through spray gun in two coat one as finishing in existing colour over one coat of red oxide primer with mounting frame, control panel Main supply (02 Nos), AMF panel etc all connecting protection and control device complete all as specified and directed with marking/ written MES No/ indications in different colour complete all as directed. Note:- Paint colour shall be approved by Deptt.
S&F in replacement to water pump assembly of DG set capacity 400 KVA in original manufacture and all technical specification as per sample with required nut bolt washer for fixing complete all ad specified and directed.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri if not specified in BOQ
Avion Industries
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .