Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹36.2 L+₹89,016.20 (2.52%)Rejected-Finance 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹40.2 L+₹4.9 L (13.9%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance BEING NOT L1 |
Tender Value
Refer Docs
EMD Value
₹86,100
Closing Date
23 Jun 2021, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA 400704
SPECIAL REPAIR TO INDOOR BADMINTON COURT BLDG NO P569 BLDG NO P548 AT AYUDH VIHAR I AND OFFICERS MARRIED ACCOMMODATION BLDG P308 M4 AT NAVAL STATION KARANJA
2021_MES_446513_1
8375/E8
Open Tender
Civil Works
Item Rate
240 days
GE NW KARANJA
SPECIAL REPAIR TO INDOOR BADMINTON COURT BLDG NO P569 BLDG NO P548 AT AYUDH VIHAR I AND OFFICERS MARRIED ACCOMMODATION BLDG P308 M4 AT NAVAL STATION KARANJA
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹86,100
Yes
31 Jul 2021
28 May 2021
25 Jun 2021
28 May 2021
23 Jun 2021
11 Jun 2021
28 May 2021 - 11 Jun 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
S&F Coloured vitrified ceramic tiles 10mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed in CM(1:6) complete all as specified and directed.
S&F Coloured vitrified ceramic tiles 10mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in skirting, dados and risers to step etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed in CM(1:4) complete all as specified and directed.
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:6) complete all as specified and directed.
S&F Coloured Glazed ceramic tiles in vertical surfaces 350x250mmx7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plaster in CM(1:4) on fair face of brick or concrete surface complete all as specified and directed.
Demolition of Stone slabs & tiles of any description or thickness in floors, aprons etc. Laid, bedded & pointed in any mortar complete all as specified and directed.
M&L 16-18mm thick Granite (of any tpe) work (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms and like in CM(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick Screed in CM (1:4) complete all as specified and directed.
M&L rounding to edges as bull nose of any type stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M&L machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 15 mm thick Screed in CM (1:4) complete all as specified and directed.
Taking down Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down Chowkats or frames exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with screws complete all as specified and directed.
S & F 18 mm thick Celuka ply wood boardof grade 1 quality of both side laminated fixed with screws, solvent cement/ adhesive to make kitchen cabinet sides top and bottom and shelves inside the cabinets cupboard with door complete as per specifications and as directed by the engineer - in -charge. Make-Rajshri complete all as specified and directed.
S & F 12 mm thick Celuka ply wood boardof grade 1 quality of both side plain white colour fixed with screws, solvent cement/ adhesive to make kitchen cabinet sides top and bottom and shelves inside the cabinets cupboard with door complete as per specifications and as directed by the engineer - in -charge. Make-Rajshri
S&F aluminium anodised 2 way track for cup boards/wardrobs incl wheel for sliding of shutter and all necessary fittings complete all as specified and directed.
S&F 150mm stainless steel decorative type handle for cupboards/wardrobs complete all as specified and directed.
S&F Brass Locks 4 levers, cupboards/wardrobs/drawers, grade I, size 65 mm complete all as specified and directed.
S&F Chromium plated Tubular towel rail 20mm dia for cup boards/wardrobs incl brackets and all necessary fittings etc. complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet & edges will be painted to match with printed sheet reinforced with M.S Square tube, in opening as per specification & drawing complete all as specified and directed.
S&F with wood free EPS factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F Aluminium handles 125mm size, cast type, anodised. Complete all as specified and as directed by EIC.
S&F Aluminium, anodised, barrel tower bolts 150mm long of extruded section complete all as specified and directed.
S&F 75mm butt hinges stainless steel complete all as specified and directed by EIC.
S&F 2nd class hardwood Plain, solid, straight, chowkats & frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Preparing surfaces of wood and wood based materials, steel and iron work, new or old of any description and girth, not otherwise described and treated with tar or coal tar black paint complete all as specified and directed.
M&L Precast cement concrete type B1 (1:2:4) using 20 mm graded aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, hold fast, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers, weathering’s, throttling etc. and setting in CM(1:4) with joints to match. Complete all as specified and directed.”
S&F MS hold fast similar small articles confirming to Fe 290 Gde -E- 165 complete all as specified and directed.
S&F 40 mm thick Flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 2nd class hardwood 35mm thick Glazed & skeleton shutters, open rebated & prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut & mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); to chowkats complete all as specified and directed.
S&F Aluminium, anodised, barrel tower bolts 200mm long of extruded section complete all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F overall length of cover plate 150mm long Floor door stopper of aluminium alloy body & tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed.
S&F 100mm butt hinges stainless steel complete all as specified and directed by EIC.
S & F night latch 7 lever Godrej brass locking mechanism steel body with scratch resistant powder coated finish of size 98mm x 67mm x 28mm as in repairs all as specified and directed.
S&F in repair magic eye incl all necessary fittings complete all as specified and directed.
Taking up or down steel tubing & connections, including cleaning (Walls, ceiling, floors, etc.) of 15mm bore complete all as specified and directed.
Taking up or down steel tubing & connections, including cleaning (Walls, ceiling, floors, etc.) of 20mm bore complete all as specified and directed.
S&F 20mm CPVC, PIPES of pressurerating 10kgf/sqcm fixed complete to wall, ceilings or in floors etc including all fitting complete all as specified and directed
S&F 25mm CPVC, PIPES of pressurerating 10kgf/sqcm fixed complete to wall, ceilings or in floors etc including all fitting complete all as specified and directed
Cutting chases, pinning in, making good to facings where required and pointing in CM(1:3) to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in brick wall complete all as specified and directed.
S&F in repairs CP Bib taps 15 mm bore, cast copper alloy with crtuch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule fancy type complete all as specified and directed.
S&F in repair Stop valves 15 mm bore fancy type, CP with long shank & cup (conncelaed type), cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs 15 mm dia bore cast copper alloy chromium plated fancy type angle cock with long shank & cup (concealed type), complete all as specified and directed.
S&F in repairs flexible jet shower(health faucet) , 25mm dia including CP flexible pipe 1.20m long heavy duty and hook incl twin one tap all necessary fittings complete all as specified and directed by Engineer-in-Charge.
S&F in repair toilet paper holder, brass chromium plated, fixed to walls with chromium plated brass screws. Complete all as specified and as directed.
S&F in repair soap dish, chromium plated, fixed to plugs with chromium plated brass screws. Complete all as specfied and as directed.
S&F in repair sheet glass shelf assemble consisiting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard railing 60cm long. Complete all as specified and as directed.
S&F in repar 15mm Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed in repairs complete all as specified
S & F in repair drapery rod powder coated 25mm internal dia with bracket incl decorative brass end knob etc and fixed on wall. Complete all as specified and directed
S&F in repairs 40mm bore CPVC pipe of pressure rating 10 kg/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed.
S&F in repairs 32mm bore CPVC pipe of pressure rating 10 kg/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed.
S & F in repairs stainless steel kitchen plate rack of size 1 mm thick (18 gauge) complete all as specified and directed.
S&F in repairs PVC valveless, syphonic action type, flushing cistern 10 litr capacity, low level, white, with intel, ball valve, float & handle including brackets complete all as specified and directed.
S&F in repairs Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste chain & plug & porcelain stopper but including brackets complete all as specified and directed.
S & F in repair wash hand basin brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed. complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers & waste; including bedding in CM to dwarf wall or including fixing cantilever brackets & connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs PVC looking mirror cabinet complete all as specified and directed. (Note: size as per approved by site requirement)
S&F in repairs Brass CP shower rose 125mm size complete all as specified and directed.
S&F in repair PVC (SWR) Floor trap 75mm dia with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) Floor trap 100mm dia with grating including jointing with solvent cement complete all as specified and directed.
S&F aluminium door/ window/ventilator/partition shutters, made out of extruded power coated aluminium sections weighing 0.55kg/m, with sliding or openable shutters including frame and necessary joining cleats, glazing clips, rubber packing, power coated aluminium snap beading, screws etc. Complete and also including the following powder coated aluminium fittings such as cobra hinges, butt hinges, tower bolts, hook & eyes, peg stay and handles connected items wtih and including star, complete all as specified and directed. Taking down existing old door/window/ventilator/partions and removing to stores. Notes:- (i) Minimum thickness of powder coating shall be 15 micron for widows and 25 microns for doors. (ii) Rubber beading shall be measured and paid for separately. (iii) Design of door, window and ventilator shutters and sections to be used in their fabrications shall be as approved by the Engineer-in-Charge/GE.
S&F Sheet glass 4.0mm thick, ordinary quality & glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed.
S&F Sheet glass 4.0mm thick, ordinary quality & glazing with oil putty in square but exc 0.5 sq.m in each pane complete all as specified and directed.
S&F frosted glass 4.0mm thick, pin head type & glazing with oil putty in squares n exc 0.5 sq.m in each pane complete all as specified and directed.
S&F rubber beading suitable for fixing 4mm/5mm thick glass in panels of aluminium doors/windows/ventilators. Complete all as specified and directed.
S&F aluminium louvers with levers and locking arrangement suitable for fixing 100mm wide4 to 6 nos glass complete all as specified and directed.
S&F star lock for window incl all necessary fittings complete all as specified and as directed.
S&F in repair aluminium (anodized) grill of design DG 104 pattern, made out of 10mm thick dia, rod fixed with and inclding standard aluminium frame of 'F' section of size 23.40mm x 15.30mm and 1.4mm thick all as per manufacturers instructions and as specified and directed.
S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire & average width of aperture 1.40mm with aluminium wire staples complete all as specified and directed.
S&F in repair Aluminium alloy wire cloth, 0.45mm nominal dia of wire & average width of aperture 1.40mm with aluminium wire staples complete all as specified and directed.
S&F Continuous (piano) hinges, Brass, bright finish or electrogalvanised with width of flaps (When open) 30 mm complete all as specified and directed.
S&F Brass knobs 35-40mm dia complete all as specified and directed.
S&F magnetic catch including all fittings complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L 20 mm thick polymer modified ready mix cement based plaster make easy plast from wall plast,chemplast, ready plast from ultra Tech on external surfaces. Complete all as specified and directed.
M & L rendering 5 mm thick in cm 1: 3 on concrete surfaces as in ceiling finished even and smooth without using extra cement.
M&L 15 mm thick polymer modified ready mix cement based plaster make easy plast from wall plast,chemplast, ready plast from ultra Tech on internal surfaces. Complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls including washing, rubbing down and stopping of nail holes and applying two finishing coat of oil bound distemper (oil emulsion) on walls over a coat of , incl 3mm thick wall care putty. complete all as specified and directed.
M & L for preparation of new plastered or unplastered surfaces of ceilings including cornices, etc and applying three finishing coat of white wash complete all as specified and directed.
Taking down 110mm pipe any type incl all fittings complete all as specified and directed.
Taking down 75mm pipe any type incl all fittings complete all as specified and directed.
S&F PVC pipe inner dia 100mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floorscomplete all as specified and as directed
S&F PVC pipe inner dia 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floorscomplete all as specified and as directed
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern & flush pipe) incl all fittings complete all as specified and directed.
Dismantling water tanks and removing to store exc 1000ltr and nexc 2000 ltrs complete all as specified and directed.
S&F 1000 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S& F for 20mm bore dia of pipe Ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and directed.
M&L 100mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as in plinth pritection,footpath ,flooring,paving and similar work like this complete all as specified and directed.
M&L 50 mm thick PCC type C-2, (1:4:8) using 40mm graded stone aggregate as sub base of flooring and like paving complete all as specified .
M&L for PCC 1:2:4 type B2 using 40 mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165
Applying two coats of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of pink primer complete all as specified and directed.
Applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome complete all as specified and directed.
M & L for new or old surfaces of exterior wall decorating and water proofing treatment to wall surface by wire brushing in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with clan water & allow to dry. Fill visible cracks/ joints by chemistic crack seal caulking compound & allow to dry for 24 hours. Apply a primer coat of chemistic prime M Seal (water base primer) and allow to dry for 6 hours. Thereafter apply 02 coats of chemistik PDS-50 (WB high build anti caronatin coating cum waterproofing) & shade by brush at the interval of 08 hours between the coat and allow to dry to match the existing shade including necessary scaffolding for any height, covering etc complete all as per specified and directed.
Demolition of Brickwork or stone/boulder masonry, laid dry complete all as specified.
M & L for Brick work with subclass ‘B’ bricks,straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as per specified and directed.
M & L for Brick work with subclass ‘B’ bricks,straight or curved to any radius, in half brick thick wall built in CM 1:4complete all as per specified and directed.
Treated the soil along with external perimeter of bldg at the rate of 2.25 ltr of emulsion per ltr of the perimeter of wall complete all as specified.
At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the samecomplete all as specified.
S & F loft type water storage tank ISI marked of capacity 250 ltrs hoisted and fixed in position including PTMT float valves of 15mm dia, high pressure with polythene float and fly nut complete, screwed for iron pipe of brass ferrule and fixed in 15mm bore GI tube etc complete all as specified and directed including taking down old tank.
Cutting into existing 100 mm dia manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required
S&F PVC SWR cowl 75 mm dia complete all as specified and directed.
S&F PVC SWR cowl 110 mm dia complete all as specified and directed.
S&F PVC SWR Bends and radius 75 mm dia complete all as specified and directed.
S&F PVC SWR bends and radius110 mm dia complete all as specified and directed.
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:6) complete all as specified and directed.
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, window jamp over 15mm thick plater in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
S & F in factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tube for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width struck in side with solvent cement for stiles and plain colour PVC sheet for top tail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement suppling and fixing the frame at site as in repairs all as per specification & drawings given in SSR 2010 Part II all as specified and directed.
S & F in repair 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified.
S&F tubes 15mm dia medium grade galvanised(GI Tube) with all fittings and fixed complete to walls and ceiling or laid in floors 15mm bore all as specified.
S&F tubes 20mm dia medium grade galvanised(GI Tube) with all fittings and fixed complete to walls and ceiling or laid in floors 20 mm bore all as specified.
Supply and fixing in repairs 15mm bib cock brass chromium plate fancy type and as directed by Engineer Incharge
Supply and fixing in repairs 15mm stop cock chromium plated but fancy type 15 mm dia with crutch or butterfly handle, screwed down high pressure complete all as specified and directed.
Supply and fixing in repairs 15 mm bore Pillar cocks cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified
S&F in Repair 32mm Waste pipe fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed completed all as specified.
S&F in repairs Vitreous China urinals, half stall Urinal type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. completed all as specified.
S&F in repairs 40mm bore unplasticised PVC pipe of pressure rating 10 kg/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed.
S&F in repairs 32mm bore unplasticised PVC pipe of pressure rating 10 kg/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed.
S&F in repair Cast iron Nahani trap 100mm dia, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
S&F 100mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stay, including bolts and nuts and securing ends of stay to wall or roof complete all as specified and directed.
S&F 75mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stay, including bolts and nuts and securing ends of stay to wall or roof complete all as specified and directed.
S&F 110mm dia PVC (SWR) branch piece singe (single Y) equal or unequal with access door complete all as specified and directed.
S&F PVC (SWR) branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parellel branches with oval access door 110mm dia complete all as specified and directed.
S&F PVC (SWR) branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parellel branches with oval access door 75mm dia complete all as specified and directed.
S&F PVC (SWR) braches pieces double (equal or unequal) ordinary or inverted (spiogot or socket) or with parelle branches with oval access door 100mm dia complete all as specified and directed.
S&F PVC (SWR) braches pieces double (equal or unequal) ordinary or inverted (spiogot or socket) or with parelle branches with oval access door 75mm dia complete all as specified and directed.
S&F in repairs Vitreous China squatting pan, `Orrisa' pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern & flush pipe) complete all as specified and directed.
Taking down existing mild steel rolling shutters for and including replacing the slates, bottom lock plates, helical springs, side guides, sponge rubber gaskets, hood cover and side bracket etc wherever required and refixing in its original position after repairs including material and labour for greasing and mechanical old and new parts of rolling shutters complete all as per directed for shutters of area n. exc 10 sqm each, complete all as specified and directed.
S&F factory fabricated mild steel (hardened) helical wire spring of size 400mm long, 80mm dia to match with existing complete all as specified and directed.
S&F factory fabricated new guide of rolling shutter made out of 1.25mm thick mild steel sheet of grade Fe-310 or Fe-410 of required length to match the existing one and including one shop coat of red oxide primer complete all as specified and directed.
S&F factory fabricated side brackets made out of 1.25mm thick mild steel of grade Fe-410 or Fe-310-0 to match with existing including one shop coat of red oxide primer complete all as specified and as directed
S&F factory fabricated new mild steel slates of 1mm thick of grade Fe-410-0 or Fe-310-0 to match with existing fitted with locking clips, riveted to slates including one shop of red oxide primer complete all as specified and as directed
S&F factory fabricated mild steel of grade Fe-410-0 or Fe-310-0 2.5mm thick bottom lock plate riveted and made of mild steel sheet of 1mm and welded with and including provision of standard locking arrangement welded to and including mild steel angle iron complete to match with existing with and including one shop coat of red oxide primer complete all as specified and as directed
S&F factory fabricated hood cover of mild steel 1mm thick hexagonal, square or circular shape fitted to existing angle iron stiffness at bottom edge and to bracket plate all as directed and applying one shop coat of red oxide primer complete all as specified and directed.
S&F mild steel safety lever lock with 4 levers for rolling shutters all as specified and as directed.
M&L for preparing old painted steel surface of any decription over 10cm in width or girth and applying 2 coats of aluminium paint over one coat of red oxide primer complete all as specified and directed.
M & L for preparation of newly or untreated plastered surface applying two coats of oil bound distemper (OBD) over a coat primer complete all as specified and directed.
M & L for preparing surfaces, plastered or unplastered old surfaces of walls applying two coat of oil bound distemper (OBD) complete all as specified and directed.
M & L preparing old decorated surfaces of ceilings and applying two coats of white wash complete all as specified and directed.
Chipping , removing carefullly concrete work by low impact hammer, breakar without damaging the structure & cleaning and disposal of debries out side the premises etc. complete all as directed. (Hard concrete should not be removed by force).
M&L for Cleaning existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete and applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr. Fixit Rust removal or ShaliRust of STP Ltd. on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry.
M & L for Carrying out application of ‘Bi-polar migratory corrosion inhibitor' EPCO-KP-100 on concrete surface. This inhibitor has migratory kind of property which permits the material to migrate to a virtual extent of 100 mm, through pores of concrete, inhibiting the corrosion and de-passivating the Electro-chemical reaction. It has property to attack anode as well as cathode, which is purely alkaline in nature (pH-9.5), so it has no carcinogen activity with concrete.
M&L for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes. Works shall be carried out as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the carck with a liberal application of the epoxy putty.
M&L for Injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers (approved make) & migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency , Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled. Make / brand of Epoxy grout - Dr. Fixit Epoxy injection or EPCO KP-HP-250 of M/s Krishna Conchem or Shaligrout EI of STP Ltd.
M&L Injecting low viscosity (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, Including, Mixing of materialas: Mixing of material components(part a&b) in the required quantities as per manufacturer's instruction by weigh batching. Grouting:Fill the grouting gun with concrete penetrating corrosion inhibitor EPCO-KP-100. Maintain desired pressure in the gun by air compressor; maintain the pressureat exit (2 to 3kg/cm2) by monitoring pressure guage at exit. Grout the material through prefixed nozzles in the structural elements@ 100ml per nozzle. Repeat the process for all the nozzles.
M & L in replacement of corroded steel reinforcement with new/fresh reinforcement complete all as specified & as directed by Engineer-in-charge. (Note: Replacement of corroded steel reinforcement to be undertaken when 20% of cross section is reduce due to corrosion)
M & L for anticorrosive Treatment to Reinforcement by application of two coats of IPNET RB (CBRI Know how) by brush on exposed reinforcement with time interval of minimum 4 hours between each coat all as specified and directed.
M&L Providing and applying structural grade epoxy-latex bond coat prior to application of any type of mortar confirming to ASTM-C- 882-91 (Arizona Slant Shear Test) to ensure bond between old concrete & new concrete by brush application all as specified and directed.
M&L Building up the profile of structural members by using latex B2 modified air cured mortar system in damaged areas (1Cement- 3 part graded cleaned pre-packed river sand- 5 to 10% latex mortar by weight of cement- 0.35% w/c ratio) in 20 mm thickness including leveling profiling etc. complete all as specified and directed.
Providing and applying jacketing around columns with Micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete.Note: Reinforcement shall be measured and paid separately.(Rates including jacketing, formwork and micro concrete) all as per manufacturer's instruction and as directed by the Engineer-in-Charge.
Complete removal of existing water proofing treatment of any description in any position including cleaning, wire brushing, watering, removal of debris upto 1500mtr distance as directed by Engineer-in-charge complete all as specified and directed.
M&L for brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified and as directed.
M&L rendering 20mm thick cement plaster in Cm 1:3 on roof top surface and chajjas including WPC by weight of 2% of total cement content complete all as specified. Note: WPC will be measured & paid seperately
Surface preparation : (i)Clean the surface thoroughly using mechanical tools and the surface to be free of dirt, oil. (ii) Repair all cracks by cutting "V" groove of size 5x5mm on roof surface and fill the gap using repair mortar Fibre Reinforced Polymer (iii) Provide 75mmx 75mm Coving / angle fillet using the above repair mortar using Latex Based Bonding Agent as bond coat. (iv)All construction joints to opened 15mmx15mm and treated with repair mortar Fibre Reinforced Polymer and Honeycombing to be pressure grouting with No Shrink cementatious Injection Grout. Water Proofing Application : The surface to be free from standing water Prime the surafce with UV stable Polyurethane water proof liquid membrane at 400gm/sqmt dilute with water 1:1 Apply 1st coat of ShaliPrime WP WB at 400gm / Sqmt. Apply 1st coat of UV stable Polyurethane water proof liquid membrane White at 1Kg/Sqmt. Place 40 Gsm Geotextile / FG Tissue as reinforcement followed by 2nd coat of UV stable Polyurethane water proof liquid membrane at 1kg/sqmt. Ensure final curing of 36hrs before carrying any further work. Extend water proofing treatment and terminate at the top of the edge of the parapet wall Seal the Groove using repair mortar. Make : (i) ShaliUrethane BTD of M/s STP Limilted (ii) Sec-I PU500 of M/s SG Corporation (iii) Impermo 3002 of M/s Pratham Enterprises (iv) Opty D5HDPU of M/s Optimus Chemicals
Dismantaling single layer Mangalore pattern or similar tiles in roofing complete all as specified and directed.
Dismantaling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling of unframed fillets, rails, posts, rafters, purlins etc., under 40 Sq. Cm in section complete all as specified and directed.
Dismantling timber scanttlings 40 sqcm and over in section, in any position unframed work complete all as specified and directed.
Dismantling boarding any description, fixed in any position with nails complete all as specified and directed.
M & L For pre painting galvalume sheet shall 0.50mm thick (total coated) thickness) 550mpa minimum, yield strength, it shall be coated with hot dip alloys of 55%, Aluminium 43.50%, zinc .5%, silicon and finished with resin coat on both side surface @ 150gm/ sqm of coating (Total both surfaces) Having overall width and laid width as specified and shall be fixed using hot dip galvanised, self drilling and self tapping screws neoprene and EPDM washerspenetrations and laps in sheet shall be provided wherever required to close voids between sheet shall be sealed by using propersealant profile. HDPE fillers shall be provided whrever required to close voids between sheet & fasteners etc fixing system shall be as per manufactures instructions and shall be safe against effects of wind velocity. Roofing accessaries ie shall be of galvalume sheet and of size shape complete all as specified and as directed.
S & F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof ridge, valley gutters etc all as specified.
Dismantling wall and ceiling boards (fibers pulp insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed.
S&F for 4 mm thick non asbestos fibre cement building board fixed with timber /GI/Aluminium frame work fixed with ceiling complete all as specified
M & L for rendering 15mm thick on other than fair faces of brick work or one side of lathing in cement mortar 1:6, surface finished even and smooth without using extra cement.
M&L for rendering 20 mm thick in cement mortar 1:4 on EXTERNAL fair faces or Brick walls or on concrete surfaces plastered surfaces finished even and smooth without using extra cement with WPS as per manufacture instruction complete all as specified.
M&L preparation of new surfaces of wall and applying two coats of acrylic emulsion paint over a coat of primer over a coat of 3 mm thick wall care putty on walls . Complete all as specified and directed.
M&L preparation of old surfaces of wall and applying two coats of acrylic emulsion paint over a coat of 3 mm thick wall care putty on walls . Complete all as specified and directed.
M&L preparation of New surfaces of ceiling and applying two coats of acrylic emulsion paint over a primer . Complete all as specified and directed.
S&F mild steel works in window guard bars palin let in and fixed with steel members etc complete all as specified and directed.
M&L flat iron fillets fixed to the fencing posts and other works incl all necessary drilling bolting or riverting etc and similar work conforming ot Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F rolled mild steel Roof trusses (framed), trussed pulins crane gantriel, rails & fastenings & heavy brackets faming (Beam, tea, angle channel or flat sections) including distance pieces, cleats etc. GDE Fe410 0 or Fe 310-O complete all as specified and directed.
S&F Sheet glass 4.0mm thick, ordinary quality & glazing with oil putty in square but exc 0.5 Sqm in each pane complete all as specified and directed.
Taking down Chowkats or frames exc 1.5 sq.m but n exc 4 sq m each with shutters (without taking off shutters from the frames) complete all as specified and directed.
M&L of Teak parquet of 154x22mmx10mm as per shade & Pattern Approved By Garrison Engeneering including fixing ,sanding and polishing of the same with water based polish and fixing with grove of each other including dismentling of old wooden flooring complete all as specified and directed.
S&F aluminium anodised snap grid frame work of size 605mmx605mmfor false ceiling with hanging arrangement 6 mm dia GI up to 1200 mm length adjustable level fixed to roof slab of ceiling cleat made out of 40x3 mm size 60 mm long complete as directed by Engineer-in-charge
M&L 75 mm thick cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as plinth protection / path finished even & smooth with out using extra cement and the like all as specified and directed.
Taking down carefully copper / aluminium point wiring (light, fan socket or power) through steel / PVC conduit / casing caping including complete fittings such as switches, ceiling roses, pendants, regulators, sockets, buzzer, bell, switch sockets, etc removing and making good to the disturbed surfaces of walls/ceiling etc, with its original specification complete all as specified and directed.
M & L for point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable (using colour code as per IS), 1100 volts grade drawn through and including concealed PVC conduit and shall be of one of the make M/s Precision/ M/s Asian/M/s Prestoplast/M/s BEC with all accessories including surface/ concealed sheet steel terminal/CI box with 3mm thick hylam/masonite sheet top including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor (using green colour) to common earth and connecting to earth dolly, the make of cable shall be one of the following M/s Finolex, M/s Havells, M/s Plaza, Polycab complete all as specified & directed for the following :-
(a) One light point controlled by one switch 5 Amp, SP, one way 240 volts.
(b) One exhaust fan point controlled by one switch SP one way 5 Amp 240 Volts
(c) One multi pin socket outlet 5 Amp on same board
M&L Point wiring single core 1100 Volts grade 1.5 sqmm size PVC FRLS insulated unsheathed stranded copper conductor cable using color code drawn through concealed PVC conduit with all modular accessories like metal flush box, cover plate frame plates of suitable sizes complete all as specified in and including 1.5 sqmm PVC insulated unsheathed copper conductor cable for continues earth conductor (using green colour) to common earth and connecting to earth dolly for the following NOTE : "The rates includes for Necessary wall cutting chasing" (a) One light/fan/bell point controlled by one switch
All as per item No 183 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 1.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board.
All as per item No 183 above but with 4 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board.
-ditto - as per item no 183 but One light point controlled by 2 way switch SP, 5 Amp, 240 Volts
-Ditto- all as per item No 183 above but One 5 Amp, 3 Pin socket point independent
Ditto, all as per sl item No 183 above, but using 2.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable for phase & 2.5 sqmm PVC insulated unsheathed multistanderd copper conductor cable for earth continuity ( green colour) for one 3 pin socket outlet 15 Amp multi purpose independent controlled by 15 Amp switch, SP, one way, 240 Volts & socket, complete all as specified and directed.
Submain wiring with single core 1100 volts 1.5 sqmm FRLS size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including concealed PVC conduit 19/20 mm dia with accessories like bend, junction box etc complete all as specified in and including 1.5 sqmm PVC insulated PVC unsheathed FRLS copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and directed by Engr-in-Charge NOTE : If more than 7.5 mtr length is used in ser No 183 above then submain wiring will be considered as point wiring and extra length of point wiring will measured in this item.
S & F switch piano flush button single pole one way, 6 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge
S & F switch socket 2 in 1, 3 pin, 6 Amp flush type (ISI marked) makes as given in Appx of PS complete all as specified and directed by Engineer-in-Charge.
S & F ceiling rose surface bakelite 65 x 50mm, three terminals ISI (Marked) complete all as specified and directed by Engineer-in-Charge.
S & F MCB SPN 240 V, 50 Hz, 10 KA conforming to IS 8828 of rating 6 to 32 Amp 'C' series complete all as specified and directed by Engineer-in-Charge. Make as per PS.
S & F MCB SP 240 V, 50 Hz, 10 KA conforming to IS 8828 of rating 32 Amp, 'C' series complete all as specified and directed by Engineer-in-Charge. Make: Legrand/Havells/L&T
S & F MCB DB, SPN, 8 way, 230 Volts as per IP-42 of complete all as specified and directed by Engineer-in-Charge. Make as per PS.
Supply, fixing, stringing and drawing submain wiring with 2 run of single core 4 Sqmm PVC insulated and unsheathed, multi stranded FRLS copper conductor cable using colour code for phase red and neutral black with and including 4 Sqmm PVC insulated and unsheathed copper conductor multistranded cable in green colour connected to common earth point and connected to earth dolly drawn through 20 mm PVC casing caping, heavy grade (ISI marked) with and including all accessories etc in replacement compete all as specified and directed NOTE:- (i) Two run of 4 sqmm, one run of 4 sqmm earth continuity conductor and 20 mm PVC casing caping and accessories shall be measured and paid as one length. (ii) Cable shall be of ISI marked of make M/s Finolex / M/s Plaza /M/s Havells. (iii) PVC conduit shall be makes given in Appx 'A' to PS.
Taking down exhaust fan of 400/450 mm sweep rated including all accessories and connecting with 3 core copper flexible cable from ceiling rose all as sepcified and directed by engr-in charge. Note- Old fan should deposit to MES store yard for repair and painting.
refixing of exhaust fan in same place with all acessories and connecting with 1.5 sqmm FRLS copper conductor from ceiling rose to exhaust fan complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED building security light fitting with suitable size bracket/angle to fit security light of 60W IP 66 protection complete all as specified and directed by Engr-in-Charge. make as per PS.
Supply and fix LED high bay luminaire 100w suitable for different modern hi tech industrial applications including connecting up with all accessories at any height with providing provision for hanging the lights complete all as specified and directed by engr-in-charge.Make as per PS.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earth testing point including necessary excavation, earth work, PCC pit ,RCC cover 1:2:4 B1 with 8 mm dia MS rounds 1.5 kgs, funnel ,watering pipe etc. all specified and directed including testing on completion.
Supply and fix panel box of size 75cmx65cmx25cm single door to accommodate DB made out of CRCA sheet complete with all accessories as specified and directed and specified by Engr-in-charge.
S & F switch modular single pole one way, 6 Amp (ISI marked) all as complete all as specified and directed by Engineer-in-Charge
S & F modular bell push flush type 6Amp (ISI marked) all as specified and directed Engineer-in-Charge.
S & F modular socket outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S & F modular socket 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S & F switch modular single pole one way, 16 Amp (ISI marked) all as complete all as specified and directed by Engineer-in-Charge
S & F ding dong door bell electric suitable for AC 230 volt, single pole complete a all as specified and directed by Engineer-in-Charge.
S & F modular type fan 5 step regulator for ceiling fan complete all as specified and directed by Engineer-in-Charge.
S & F flush type fan 5 step regulator for ceiling fan complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED batten with 20W LED tube light in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver and including LED tube rod.as directed and specified by engr-in-charge.Make Bajaj CT PT NO- BCLAB 20W or equivalent in CG/C&S
Supply and fix LED batten with LED tube light 10W 2 feet in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc as directed and specified by engr-in-charge.Make Bajaj ct pt no BCLSB 10NW including LED tube rod or equivalent in CG/HAVELLS/bajaj
S&F MCB double pole RCBO 240 volts AC 40 Amps (C-series) OF 30MA all as specified and directed by engr-in-charge
Taking down ceiling fan and keeping in safe custody for reuse and refixing the same after duly painted and marking of MES number on ceiling fan of size 1200mm sweep complete with connected accessories as directed and specified by engr-in-charge .make-havells
Refixing of ceiling fan/wall fan/ exhaust fan taken down against Item No 215 and connecting with ceiling rose with proper size flexible black copper wire completed all as specified and directed by Engineer-in-Charge
Taking down geyser and keeping in safe custody for reuse and refixing the samed after duly painted and marking of MES number on geyser 25ltr including all connected accessories like pvc connection hot/cold water etc all as directed and specified by Engr-in-charge
Supply and fixing LED building security light fitting with suitable size bracket/angle to fit security light of 45w IP 66 protection LED make bajaj ct pt no-BRTFG 45 Watt
Supply and fix LED decorative wall mounting chrome finish fixture with textured glass with 5 w led lamp MAKE-HAVELLS ct pt no-LHFOFDC1TZ1C040 or equivalent in bajaj/CG
Supply and fix sheet metal enclosure with socket plug top and 20 amp single pole MCB complete all as specified and directed .
Supply & fixing, jointing, connecting & testing in trenches XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of following sizes including taking out cable cover & cable all as specified and directed : 2 core 16 Sqmm
Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in soft/loose soil including taking out faulty cable/cable covers and GI pipe complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above complete all as specified & directed.
M & L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers all as specified
Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed.
M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 40 mm bore of pipe complete all as specified & directed.
S & F switch single pole two way, 6 Amp (ISI marked) all as complete all as specified and directed by Engineer-in-Charge
S & F switch socket outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) all as per Cat No 14615 of M/s Anchor Penta or equivalent complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, stringing and drawing submain wiring with 2 runs of single core 6 sqmm PVC insultaed, unsheathed multi stranded copper concuctor cable, 1100 Volts conforming to IS-694 1990 with ISI mark, drawn through and including PVC conduit 25 mm bore/ stove enamelled steel conduit 25 mm bore / PVC casing capping 25 mm size including one run of 4 Sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694, 1990 green colour for earth contuinity and connecting up to common earth dolly complete all as specified and directed. Note:- Two run of 6 Sqmm and one run of 4 Sqmm earth wire will be measured as one running metre
Supply, fixing, stringing and drawing submain wiring with 4 runs of single core 6 sqmm PVC insultaed, unsheathed multi stranded copper conductor cable, 1100 Volts grade conforming to IS-694 1990 with ISI mark, drawn through PVC conduit 25 mm bore/ stove enamelled steel conduit 25 mm bore / PVC casing capping 25 mm size including two run of 4 Sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694, 1990 green colour for earth continuity and connecting up to common earth dolly complete all as specified and directed. Note:- Four runs of 6 sqmm cable, one run of 4 sqmm earth wire will be measured as one running metre
S & F replacement MCB SPN distribution board sheet steel, phosphorised powder painted MCB DBs with busbar neutral link, earth bar and DIN rail conforming to IS, 4 way double door, 230 volts, 50 HZ, AC make Cat No. DHDNSNODRW 04 of M/s Havells or equivalent of Standard/legrand/HPL
Taking down unserviceable XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor from wall through necessary arrengements of size 2 core 6 sqmm
Supply & fixing, jointing, connecting & testing in trenches/surface XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of size 2 core 6 Sqmm including necessary arrengement of saddle the cable on wall complete and all as specified and directed by Engineer-in-charge.
Mahadev Enterprises
M.K Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .