Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹38.3 L+₹56,557.05 (1.50%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹38.7 L+₹89,488.10 (2.37%)Rejected-AOC | L3 | Rejected-AOC Rejected being L3 | |
| 4 | L4₹38.7 L+₹96,795.15 (2.56%)Rejected-AOC | L4 | Rejected-AOC Rejected being L4 | |
| 5 | L5₹39.0 L+₹1.3 L (3.39%)Rejected-AOC | L5 | Rejected-AOC Rejected being L5 |
Tender Value
₹3.4 Cr
EMD Value
₹68,000
Closing Date
21 Jul 2023, 6:00 pmClosed
GE 867 EWS
GE 867 EWS PIN 913867 C/O 99 APO
REPAIRS/MAINT OF LT PANEL LT DISTRIBUTION OH LINE, UG CABLE, MCCBS, SERVO VOLTAGE STABLIZER, SECURITY/STREET LIGHT, POLE PAINTING ETC AND CONNECTED MISC ITEMS OF WORK AT ZONE A AND ZONE B AREA AT KPG UNDER GE 867 EWS
2023_MES_605312_1
GE /867/ TOKEN/ 18 OF 2023-2024
Open Tender
Civil Works
Item Rate
270 days
Kalimpong
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹68,000
Yes
8 Sept 2023
23 Jun 2023
24 Jul 2023
23 Jun 2023
21 Jul 2023
7 Jul 2023
23 Jun 2023 - 5 Jul 2023
Amount
Excavation in trenches in soft/ loose soil not exc 1.5 mtr wide and not exc 1.5 mtr deep in for lying of electric cable, pole foundation and stays etc and getting out, trimming the sides, forming bottom surfaces to required level complete all as specified and as directed.
All as per item No. 1 above but exceeding 1.5 mtr and not exc.3.0 mtr, complete all as specified and as directed.
Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 250mm thick after cable are laid and tested complete all as specified and as directed.
Removing excavated material (Surplus soil) to a distance not exc 50m and depositing where directed at level not exc. 1.5m above the starting point complete all as specified and as directed.
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches, total 23 CM complete all as specified and as directed. Note - for measurement purpose punned thickeness 18 CM shall be considered
S & F Sub class B bricks having minimum compressive strength 75 Kg/Sqcm laid in trenches for cable protection etc complete all as specified and as directed.
M&L for Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish, complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundtion for pole including necessary form work complete all as specified and as directed.
M & L for plain cement concrete (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) incl necessary form work complete all as specified and as directed.
M & L for Plain Cement Concrete (1:2:4) type B1 (using 20 mm graded stone aggregae) as in copping including necessary formwork, weathering, slightly rounded or chamfered angles, finishing of exposed surfaces of concrete to even and smooth without using extra cement complete all as specified and as directed.
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trench/ on wall with the help of shadel of following size as required at site size of 150 Sqmm 3.5 Core, complete all as specified and as directed.
All as per item No. 11 above but 120 Sqmm 3.5 Core, complete all as specified and as directed.
All as per item No. 11 above but 95 Sqmm 3.5 Core, complete all as specified and as directed.
All as per item No. 11 above but 50 Sqmm 3.5 Core, complete all as specified and as directed.
All as per item No. 11 above but 35 Sqmm 3.5 Core, complete all as specified and as directed.
All as per item No. 11 above but 25 Sqmm 4 core, complete all as specified and as directed.
All as per item No. 11 above but 16 sq mm 4 core, complete all as specified and as directed.
All as per item No. 11 above but 10 Sqmm 4 core, complete all as specified and as directed.
All as per item No. 11 above but 2 core 10sqmm, complete all as specified and as directed.
All as per item No. 11 above but 6 sqmm 4 core, complete all as specified and as directed.
Dismantling / Taking out Unserviceable LT cables of size upto 35 sqmm any core from any position i.e ground / walls / poles / culverts etc complete with protection pipe complete all as specified and as directed.
Laying only LT under ground cable PVC/XPLE insulated PVC sheathed 1100 V grade armoured/ unarmered any type including testing commissioning of the cross sectional area 6 mm² to 150 Sq mm², 2/ 3.5/4 core, complete all as specified and as directed. Note :- Cable will be issued under Sch 'B' free for fixing. Excavation and earthwork will be measured under respective items.
S & F in repair 'Tubes "light grade" galvanised iron, laid under roads/drain, fixed to poles, walls, with flat iron clamps bolts/nuts/washers of the following sizes of 50 mm dia bore complete all as specified and as directed.
All as per item No.23 above but 40 mm dia, complete all as specified and as directed.
All as per item No.23 above but but 25 mm dia, complete all as specified and as directed.
M & L for junction box hot press moulded SMC of 295 x 195 x 100mm and outside dimention 32 with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having TPN Bus bar 100A amps capacity with necessary base insulator and including necessary flat iron clamps with nuts, bolts & washers complete all as specified and as directed. Make- Sintex Industries Ltd or equivelent make.
Dismantling and taking down any type of LT poles from any location complete all as specified and as directed.
Supply, Install and errect in true vertical position steel tubular swaged poles in replacement complete with MS base plate of 6mm of size 300mm X300mm finial taper plug,pole cap,bolts,nuts and washers screws,pole made out of ERW MS tubing as per IS-1161 and pole shall be as per IS-2713 Part II type 410SP-31 (9.00 Mtrs Long) complete including one coat of red oxide zinc chrome primer and two coats of Aluminium paint for exposed surfaces and two coats of black bitumenous paint for portion embedded in concrete complete all as specified and as directed. Note: Excavation and earth work ,PCC in foundation /plinth block/coping shall be measured and paid for separately
Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and as directed.
Supply and fixing cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including a coat of red oxide primer one underand & one finishing coat complete all as specified and as directed.
Material and labour for disconnection of electric cable from pole and bringing it to ground for cutting of damaged part of cable and putting insulation tape and reconnecting the same on exising pole after taking out additional cable from loop of the cable after excavation complete all as specified and as directed.
Material and labour for Load balancing of LT panel in all three phases of all outgoings complete all as specified and as directed under:- a) Taking of load of LT panel out going cables with the help of tong testing three times in a day to assess maximum unbalance of load. b) To disconnect the LT cables/ TC wires and reconnect the same as per the load of the MCCB to balance the circuit. c) Take the building wise load on the panel and make the load balance at bldg end.
Material and labour for cleaning of panel busbars and cable termination with the help of CRC spray, dismantling the cables from connections, lubrication of hinges of panels, welding of hinges if required and reconnecting the cables after cutting of damaged cable parts and relugging complete, tapping if required, cleaning the complete panel after disconnection from main supply and taking out of loop complete all as specified and as directed. Note :- i) Contractor will take proper shut down of panel from Power house before starting the work.
Trimming of tree branches which touches the LT/HT OH lines and 2.5 Mtr away from centre line of LT/HT oh lines span not exceeding 60 Mtr distance between poles by using neccessory T&P items and depositing the tree branches/leaves at 30 Mtrs away from the site, complete all as specified and as directed. Note -Any number of tree branches cut in one span will be measured as one lenght for payment ,
Restringing of existing LT overhead line including removing the existing binding wire and rebinding with new binding wire after tightning of overhead lines including disconnecting existing jumpher and connections and reconnecting after tightning of conductor incl replacement of all jumpers complete all as specified and as directed. Note - (a) Single wire run of conductor in LT lines shall be measured as one lenght for payment purpose. (b) ACSR conductor will be measured and paid separately.
Repairing of LT panel by means of replace the hinge and locking arrangement of the existing panel, tightening the cable with bus bar by means of suitable lugs complete all as specified and as directed.
Material and labour for spray painting to outdoor/Indoor type double door LT panels/Fedder pillar box incl angle iron stand by applying two coats of synthetic enamel paint over a coat of red oxide primer after cleaning the surface thouroughly with scrapper of MS sheet and angle iron stand incl cleaning of cables, wiring and other non painted parts of paint complete all as specified and as directed.
Material and labour for replacement of old unserviceable voltmeter/ Ammeter with Panel mounted multi function three phase digital energy meter of accuracy Cl-1.0 for measuring Voltage, Current, KW, KVAR, KWH, KVAH and power factor and making the disturbed surface good by welding/riveting in MS sheet 1.6 mm thick on the hollow portion duly painted and replacement of wiring if required complete all as specified and as directed. Make: Schneider EM6400 with RS 485 Port or equivalent in Siemens/L&T.
Material and labour for replacement of old unserviceable indicators any type with LED based indicating lamps of RYB colour incl making hole in existing panel complete all as specified and as directed. Make : Legrand/ABB/Siemens
Material and labour for replacement of old unserviceable CT of LT Panel /Feeder pillar box with CT of 100/5A ratio, 5 VA incl connecting, disconnecting and testing complete all as specified and as directed.
Material and labour for replacement of old unserviceable CT of LT Panel /Feeder pillar box with CT of 160/5A ratio, 5 VA incl connecting, disconnecting and testing complete all as specified and as directed.
Supply, jointing and testing staright through joint Heat shrinkable type with jointing kit suitable for LT 1100 Volt graded XLPE size 150 to 185 sqmm x 3.5 core in any situation/position complete all as specified and as directed. Make : Denson/Raychem/Cabseal
Supply, jointing and testing staright through joint Heat shrinkable type with jointing kit suitable for LT 1100 Volt graded XLPE size 70 to 120 sqmm x 3.5 core in any situation/position complete all as specified and as directed. Make : Denson/Raychem/Cabseal
Supply, jointing and testing staright through joint Heat shrinkable type with jointing kit suitable for LT 1100 Volt graded XLPE size 25 to 50 sqmm x 3.5 core in any situation/position complete all as specified and as directed. Make : Denson/Raychem/Cabseal
S & F for replacement of pin type insulator porcelain vitreous white/ brown or green including one galvanised mild steel spindle two GI washer and one GI nut 100mm height, 65mm dia for 1100 Volt grade complete all as specified and as directed.
S & F for replacement of Sackle type insulator porcelain vitreous white/ brown or green including one galvanised mild steel straps of size 31 x 5 mm, washers insulator bolt of 14 mm dia and nuts complete of size 100 mm hight and 115mm dia of working pressure 1100 volts grade complete all as specified and as directed.
M&L in replacement of u/s MCCB of 4 pole of capacity 63 to 100 Amps 415 Volts with breking capacity 16 KA complete all as specified and as directed. Make:- L&T/ Legrand/ Scheinder/ Siemens
M&L in replacement of u/s MCCB of 4 pole 200 Amps adjustable type, 415 Volts, with breking capacity 36 KA complete all as specified and as directed. Make:- L&T/ Legrand/ Scheinder/ Siemens
M&L in replacement of u/s MCCB of 4 pole 250 Amps adjustable type, 415 Volts, with breking capacity 36 KA complete all as specified and as directed. Make:- L&T/ Legrand/ Scheinder/ Siemens
M&L in replacement of u/s MCCB of 4 pole 400 Amps adjustable type, 415 Volts, with breking capacity 50 KA complete all as specified and as directed. Make:- L&T/ Legrand/ Scheinder/ Siemens
S&F in replacement of primary relay foe 50 KVA 3 phase, 415 v, 50 Hz servo voltage stablizer including all electric connections complete all as specified and as directed.
S&F in replacement of secondary relay relay foe 50 KVA 3 phase, 415 v, 50 Hz servo voltage stablizer including all electric connections complete all as specified and as directed.
M&L for control wiring as per existing with color coding and marking in 50 KVA, 3 phase, 415 volt with copper wire complete all as specified and as directed.
M & L for preventive maintenace/periodical servicing of 50 KVA servo voltage stablizer by checking the various critical setting in mechanism, checking of oil, checking of cooling fins, conrol wirig & testing of servo votage stablizer for smooth and correct fuctioning complete all as specified and as directed.
M&L for earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.3 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, Plain cement concrete (1:3:6), type C-1 chamber, Reinforcement cement concrete (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and as directed.(set of two) NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
Supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box in replacement, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars 400Amps capacity for looping & branch connection system .The chamber shall be painted with powder coated paint. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55, complete all as specified and as directed. (a) The bus bar chamber shall be made out of 3.0mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and angle iron padastal frame 600mm high above ground level. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. (Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 600mm height (without base frame & canopy), 600mm width and 500mm depth).
M&L for painting of 9 Mtr Long steel tubular LT pole , vertical complete with cross arms with one coat of aluminium paint after cleaning and preparation of surfaces of poles, cross arms, painting 30 cm wide Yellow and black strip on poles up to 1.5 mtr high above coping level and numbering of size 70mmx40mm by using stencil to the pole with black synthetic enemal paint (1st grade ) complete all as directed.
Labour only for disconnection of off road existing security light fitting of any type by isolating jumper from OH line, terminal connection from junction box and removing carbonised/ defective part of the cable including replacement of unserviceable cable connection and reconnecting the same after making security light in ON road position complete all as directed by Engr-in-Charge. Note : New cable connection will be measured and paid separately under respective item.
Supply and fix in replacement of Street light driver of 40 watts, 230 V, 50 HZ, suitable for operation over voltage range and by removing from existing position complete as per following make and model complete all as specified and directed by EIC. Model - LSTS-40-CDL Make-Crompton/Philips/Surya/Havells Note : i) T&P required for carry out the repair work on street lights at a height up to 15 meter will be arranged by contractor and rates for the same deemed to be included in quoted rates. ii) Contractor is bound to provide material to match the technical specification of LED fittings and material is also required to fix casing of LED fitting. iii) Before quoting the rate of driver contractor should check the technical specification of the driver.
All as per item No 59 above but cap. of 45 Watt LED fitting complete as per following make and model or as directed by EIC. Model- 1) ENDURAPEARLNEOSL45WLED757SASYTOPC Make-Crompton/Philips/Surya/Havells.
All as per item No 59 above but cap. of 50 Watt LED fitting complete as per following make and model or as directed by EIC. Model- 1) LSTP-60-CDL 2) Havells model- Jeta Neo 50 (IP65) Make-Crompton/Philips/Surya/Havells.
All as per item No 59 above but cap. of 60 Watt LED fitting complete as per following make and model or as directed by EIC. Model- 1) ENDURAPEARLPLUSSL60WLED757SASYTOC 2) Surya model-SLEUL60WIP66LXN Make-Crompton/Philips/Surya/Havells.
All as per item No 59 above but cap. of 90/120/110 Watt LED fitting complete as per following make and model or as directed by EIC. Model- 1) LFLN-120-CDL/60" 2) LFLN11-110-CDL/60 3)Surya model- SLEFL120WIP65LUMOS 4) SLEUL90W IP66LXN Make-Crompton/Philips/Surya/Havells.
All as per item No 59 above but cap. of 35 Watt Post top LED fitting complete as per following make and model or as directed by EIC. Model- 1) RUBYPT35WLED757PSYMTOPC Make-Crompton/Philips/Surya/Havells.
All as per item No 59 above but cap. of 8 Watt BAMBOO bollard light LED fitting complete as per model or directed by EIC. Make-Crompton/Philips/Surya/Havells.
All as per item no 59 above but cap of 15 Watt post top , LED fitting complete as per cat part No RUBYMINIPT15WLED757PSYMTOPC of Havells.
Supply and fix in replacement of surge protector of 5 KV suitable to accomadate in LED street/flood light fittings of 25/30/36/45/60/72/100/120/135/150/165 and 200 Watts, 230 V, 50 HZ by removing from existing position complete all as specified and as directed. Note : i) T&P required for carry out the repair work on street lights at a height up to 15 meter will be arranged by contractor and rates for the same deemed to be included in quoted rates. ii) Contractor is bound to provide material to match the technical specification of LED fittings and material is also required to fix inside casing of LED fitting. Make-Philips/Wipro/Crompton/Goldwyn/Decorex.
Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. MAKE :- Phillips/wipro/Crompton.
Supply and fixing in replacement LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. MAKE :- Phillips/wipro/Crompton.
Supply and fixing in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. MAKE :- Phillips/wipro/Crompton.
Supply and fixing in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. MAKE :- Phillips/wipro/Crompton.
Supply and fixing in replacement post-top-luminaire, 15 watt, IP-65 protoection, operating temp -10 degree celcius to +45 degree celcius, Operating voltage range - 140-270 V, guaranteed burning life 50000 hours, Die-cast aluminium spigot housing for mouting of driver with spun aluminium canopy painted white inside, epoxy powder coated matt black finish, Lumen efficacy >140 lm/watt, high quality polycarbonate cover with acrylic diffuser, electronic driver powered by integral in ABS housinng with APFC, SMPS based constant current supply with lower THD, Short ciruit, over voltage, surge voltage protection as per IS 15885 Part-2/Sec -3. Mounting suitable for pole having 50 to 70 mm dia complete all as specified and as directed. Make : Havells, cat part No RUBYMINIPT 15WLED757PSYMTOPC, Model : RUBY (Clear) or equivalent.
Material and labour for Stringing of existing stays after dismantling from pole and refixing the same after properly straightning of conductor complete all as specified and as directed.
Taking out and relaying of existing brick/cable cover to the existing trench after completion of fault finding work of cable complete all as specified and as directed. Note :- Excavation work will be paid under respected item.
Material and labour for taking out and relaying of existing cable of any size after completion of fault finding work of exiting cable complete all as specified and as directed. Note :- Cost of excavation of cable will be paid respective item.
Supply & fixing in replacement automatic street light switch of rating 8 KW in single phase using nature sensor for automatic swithing "ON/OFF" of street lighting based on lux level of natural light along with 63 Amps contactor, MCB 63 Amps with support terminals prewired with PVC insulated 16 Sqmm multi strand copper wire enlosed/housed in pole wall mounted enclosure made of rust proof , shock proof , termite proof & dust proof FR grade moulded compound Junction Box complete all as specified and as directed. Model - SWADEEP - 02EC 8 KW 1 P MAKE- 1.Nature-Nature Switch : Kakatiya Energy systems Pvt. Ltd / HEALER / BAJAJ
Supply & Fix in replacement 3 Core copper cable 1100 volts grade PVC insulated and PVC sheathed of size 1.5 sqmm complete all as specified and as directed.
M&L for Painting of complete GI post top light fitting pipe hight upto 1 mtr with PCC protection of pipe by applying single coat of synthetic enamel paint after preparation of existing surface of GI post , colour as existing or directed by Engineer in charge.
Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment.
SCHEDULE OF CREDIT
SUNIL PRADHAN
PRASAD PRADHAN AND SON
MANOJ JINDAL
DEEP CHANDRA JOSHI
HEM RAJ GURUNG
SANJAY SAW MILL
G K SUTHAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .