CHIEF ENGINEER KANPUR
CHIEF ENGINEER KANPUR
Internal electrification work in Flated Factory at Industrial Estate, Amausi, Lucknow
2026_MSME_1154780_4
22/CE/26-27
Open Tender
Electrical Works
540 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,850
Executive Engineering UPSIC KANPUR
₹2.0 L
KANPUR
27 May 2026
27 May 2026
8 Jun 2026
27 May 2026
6 Jun 2026
27 May 2026
2 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | A-Common Services & BackupSupply, installation, Testing & Commissioning of 200 KVA 'Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,GeoTag of manufacturing location, rating plate as per relevant IS Code etc.(A) Diesel Engine:
Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications(C) Alternator:
Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame & Foundation:
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUELTANK:
Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
(F) Exhaust System:
Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System:
12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications. (I) AMF Panel:
Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.
2. Auto/Manual/Test/Off selector switch
3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay)4. 3 Sets of current transformers 15 P10 accuracy for protection and 15 VAclass-I for metering.
5. Energy analyser unit to indicate current, Voltage( L-N & L-L), kW, kVA (Phase & Total), Frequency, KWH, PF.
6. LED Indicating lamps for load on mains and load on set.
7. Fuse/ MCB for instruments.
8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor.
10. Supply failure timer.
11. Restoration timer
12. Control unit with three impulse automatic engine start/stop and failure to start lockout.
13. Impulse counter with locking and reset facility.
14. ON/OFF/Control circuit switch with indicator
15. Audio/Video annunciation for
(i) High water temperature
(ii) Low lubricating oil pressure
(iii) Engine over speed
(iv) Engine fails to start
(v) Full load/maximum load warning
16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories
17. Maintenance notification based on Engine Run Hour & due date.
18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel, interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.sch no- DSR-29.1.10 | 1 | Each | 13,11,542.37 | ₹13,11,542.37 |
| 2 | Common Services LT Panel with AMF 100 KVA DSR-25- 25.1.3 | 1 | No | 2,52,182.2 | ₹2,52,182.2 |
| 3 | Providing & Laying GI Strip 32mmx6mm from earth electrode directly in ground as required DSR E&M -6.12 | 300 | Mtr | 102 | ₹30,600 |
| 4 | LT PVC Cable 4 Core 16 Sqmm Al. Arm. Cable from Common Panel to Floor Common DB's on Wall surface UPPCL-pwd-24 item no-20c.1.9 | 15,000 | Mtr | 254.25 | ₹38,13,750 |
| 5 | LT XLPE Cable 3.5 Core 70 Sqmm Al. Arm. Cable from Common Panel to Fire Panel on Wall surface UPPCL-pwd-24 item no-20c.1.13 | 300 | Mtr | 646.64 | ₹1,93,992 |
| 6 | LT XLPE cable 3.5Cx150 sqmm. from DG to Common Panel with 10% Loop on Wall surface UPPCL-pwd-24 item no-20c.1.16 | 500 | Mtr | 1,100.05 | ₹5,50,025 |
| 7 | Supplying and making end termination with brass compression gland for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 70 sq. mm (38mm) DSR-11.1.23 | 10 | Nos | 396.63 | ₹3,966.3 |
| 8 | Supplying and making end termination with brass compression gland for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 150 sq. mm (50mm)DSR-11.1.26 | 10 | Nos | 590.7 | ₹5,907 |
| 9 | Supplying and making end termination with brass compression gland for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)DSR-11.1.33 | 40 | Nos | 261.87 | ₹10,474.8 |
| 10 | Providing and fixing circular/Hexagonal G.I. Box for ceiling fan clamps, of internal dia 140 mm, 73 mm height, top LID of 1.5 mm thick G.I. sheet with its top surface hacked for proper bonding, top LID shall be screwed into the G.I. box by means of 3.3 mm dia rounded screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shap as per standard drawing.DSR Civil-10.18 | 250 | Each | 220.65 | ₹55,162.5 |