Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance HOUSING COLONY UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance RAM KALA MANDIR GALI K K ELECTRICALS COURT ROAD UDHAMPUR RAMNAGAR CHOWK UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹33,000
Closing Date
6 Sept 2024, 3:00 pmClosed
Executive Engineer Electric Division UdhampurJPDCL
Executive Engineer Electric Division UdhampurJPDCL
Installation of electric poles and shifting of transformer
2024_PDD_257527_1
ED/Udh/14 of 2024-25 dt. 16-08-2024
Open Tender
Electrical Works
Turn-key
60 days
in district udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Electric Division JPDCL
₹33,000
24 Sept 2024
16 Aug 2024
7 Sept 2024
16 Aug 2024
6 Sept 2024
16 Aug 2024
16 Aug 2024 - 31 Aug 2024
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of single phase two wire LT line with 30 mm sq conductor for Installation of Electric Poles Pyt. Hartyan Block. Ghordi -PDD -PRI
8 mtr. Long PCC poles (PCC-WL 200KG)
8 mtr. Long ST poles (ST-410 SP15)
GI M Clamps for shackle insulator
GI U Clamps for shackle insulator
30mm² ACSR Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with one coat of red oxide and two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of single phase two wire LT line with 30 mm sq conductor for Installation of poles with fuse conductors in different locations of Pyt Prowa Jagir Block Jaganoo -PDD -PRI
8 mtr. Long PCC poles (PCC-WL 200KG)
8 mtr. Long ST poles (ST-410 SP15)
GI M Clamps for shackle insulator
GI U Clamps for shackle insulator
30mm² ACSR Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with one coat of red oxide and two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of single phase two wire LT line with 30 mm sq conductor for Provision of PCC poles in W.No.1,2 ,3 Pyt Sunal Block Jaganoo- PDD-PRI
8 mtr. Long PCC poles (PCC-WL 200KG)
GI U Clamps for shackle insulator
30mm² ACSR Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of single phase two wire LT line with 30 mm sq conductor for Installation of Electric poles & other accessories at W. No. 04, Pyt. Khoon PDD PRI
8 mtr. Long PCC poles (PCC-WL 200KG)
GI U Clamps for shackle insulator
30mm² ACSR Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Shifting of transformer along with allied works at W. No. 5, Pyt. Pathwar PDD PRI
Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
120mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
9 mtr. Long ST poles (ST-410 SP33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
GI Channel /Angle/flat of sizes including clamps
Galvanized Nuts and Bolts.
LT Fuse set made 50x6mm angle iron and 50x6mm Aluminium Bus bar strip fixed on Bus Bar insulator.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI barbed wire for Anti climbing
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of ST poles 9 mtr. Long with 2 coats of Aluminum paint.
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of three phase four wire LT line with 30 mm sq ACSR conductor for Shifting of transformer along with allied works at W. No. 5, Pyt. Pathwar PDD PRI
8 mtr. Long ST poles (ST-410 SP15)
GI M Clamps for shackle insulator
30mm² ACSR Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with one coat of red oxide and two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of single phase two wire LT line with 30 mm sq conductor for Electric poles at pyt Thalora PYT. THALORA BLOCK MAJALTA PDD PRII
8 mtr. Long PCC poles (PCC-WL 200KG)
GI U Clamps for shackle insulator
30mm² ACSR Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of three phase four wire LT line with 30 mm sq conductor for Electric poles at pyt. Sunwal Block Majalta PDD PRI
8 mtr. Long ST poles (ST-410 SP15)
GI M Clamps for shackle insulator
30mm² ACSR Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with one coat of red oxide and two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of three phase four wire LT line with 30 mm sq conductor for Electirc pole palater and Jansal Jugawal pyt jansal block majalta PDD PRI
8 mtr. Long ST poles (ST-410 SP15)
GI M Clamps for shackle insulator
30mm² ACSR Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with one coat of red oxide and two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
KULDEEP KUMAR SUDAN
Jeet Kumar
M/S D.K TRADERS
SWASTIK ELECTRICAL AND CONSTRUCTION WORKS
JAI CHANDI MAA ENTERPRISES
M/S K.K ELECTRICALS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .