GE Faizabad
GE MES faizabad
REPAIR MAINT OF STPs SEWAGE PUMP INSTALLATIONS AND SUPPLY OF WATER TREATMENT CHEMICALS UNDER AGE EM AT GE FAIZABAD
2021_MES_430377_1
8138/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Faizabad
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE faizabad
₹40,000
Yes
30 Jul 2021
13 Mar 2021
13 Apr 2021
13 Mar 2021
12 Apr 2021
27 Mar 2021
Amount
Comprehensive maintenance of complete STP 02 nos. at Himachal Niwas(650 KLD), Kandhar Line (550 KLD) and Sewage Disposal Plants 02 nos at OGB 32 & Punjab Niwas including pumps, motors, blowers,valves,LT panels,carbon media filter, dual media filter, chemical dosing plants and its accessories complete.Initially with the commencement of contract servicing including replacement of faulty spare parts of all plant equipments along with complete cleaning as a one time precautionary measure and thereafter maintenance and repairs as and when requried to run the plant with full efficiency without break down including Saturday,Sunday and holidays and mechanic with adequate experience should be avaiable to rectify in case any fault observed and all as specified and directed by Engr-in-Charge. Note :(a)The rate quoted against above items are inclusive of cleaning of Non Clog Submersible Pump Sets (1 working + 1 standby) upto 12.5 HP capacity every alternate month (total six times in the contract period) by lifting and lowering each from 02 Nos equalisation tank, 04 No underground sump of sewage disposal / treatment sumps including cleaning of flocculation chamber and tube settler each 02 Nos every alternate month. If the contractor fails to respond a penalty of Rs 500 per day per month will be deducted.(b)The rate quoted against above items are inclusive of repair, reassembling after testing Non Clog Submersible Pump/ Centrifugal Pump Set upto 12.5 HP capacity including lifting and lowering out carefully from underground sump of sewage disposal / treatment sumps by removing cable connection from LT panel.(c)All type of T & P for dismantling, repairing, lifting and lowering arrangement etc at site will be arranged by the contractor and cost of the same deemed to be included in the quoted rate.(d)The rate quoted against above items are inclusive of Motor housing & sleeve repairing on Lathe.(e)The rate quoted against above items are inclusive of all fast moving items and consumables as listed in particular specifications & like grease,topping up of chemicals daily etc, which may be required for smoth functioning of the plants as decided by GE.(f)The rate quoted against above items are inclusive of removal of vegetation growth on sludge bed and nearby areas if any every month.(g)The cost also includes for making stand by arragnment to avoid any type of breakdown by putting standby motor/pumpset serviceable at all time.(h)The above quoted rate shall not include for supply of spares/items which are covered under schedule 'A' Part-III and spares which are not indicated in sch. 'A' Part-III but are required for smooth running of plant shall be deemed to be included in the above quoted rate. GE's decision in this regard shall final and binding. However all labour charges for replacing spares, testing, commissioning transportation etc shall be deemed to be included in the above quoted rates.(j)Any other major spare parts not included in Sch 'A' Part-III which are otherwise urgently required for keeping the plant in serviceable condition shall be measured and paid separately. Decision of GE in this regard shall final and binding.(k)After getting complaint contractor will rectify the fault/ bottleneckness within 24 Hrs and only if rewinding of motor has to be done time to rectify the fault within 72 Hrs. If contractor fail for any reason, a fine of Rs 1500/- per day will be recovered from the contractor.
Supply only Ball Bearing No.6309(Make :-SKF/NBC/GPZ) for non clog monoblock submersible pump set of capacity12.5 HP . Make: Kirloskar/KSB.
All as per item no. 2 but Bush Shaft sleeve MS
All as per item no. 2 but Rubber Coupling
All as per item no. 2 but Copper wire S/E (super enamelled) with insulating material for rewinding
Supply only Ball Bearing No.6308( Make :-SKF/NBC/GPZ.) for non clog monoblock submersible pump set of capacity 5 HP of Make: KSB
All as per item no. 6 but Bush Shaft sleeve MS
All as per item no. 6 but Rubber Coupling upto No.14
All as per item no. 6 but Copper wire S/E (super enamelled) with insulating material for rewinding
Supply only Ball Bearing for centrifugal pump set of capacity 7.5 HP of Make Havells-Lafert & Kirloskar
All as per item no. 10 but Rubber Coupling upto No. 6
All as per item no. 10 but Gland packing
All as per item no. 10 but packing paper
All as per item no. 10 but water seal
All as per item no. 10 but Starting Coil
All as per item no. 10 but Brass Impeller
All as per item no. 10 but Copper wire S/E (super enamelled) with insulating material for rewinding
Supply only ball Bearing for monoblock centrifugal pump set capacity 3 HP of Make Kirloskar
All as per item no. 18 but Rubber Coupling upto No. 6
All as per item no. 18 but Gland packing
All as per item no. 18 but Packing paper
All as per item no. 18 but Water seal
All as per item no. 18 but Starting Coil
All as per item no. 18 but Brass Impeller
All as per item no. 18 but Copper wire S/E (super enamelled) with insulating material for rewinding
Supply only Ball Bearing No.6309 2RSC3 (Make :-SKF/NBC/GPZ.) for 3 phase induction motor 11 KW (for blower) of Make Kirloskar.
All as per item no. 18 but Fan Belt SPA-PT 1450 Fenner Make:- Powertran
All as per item no. 18 but Shaft sleeve MS
All as per item no. 18 but Gland packing
All as per item no. 18 but Packing paper
All as per item no. 18 but Starting Coil
All as per item no. 18 but Copper wire S/E (super enamelled) with insulating material for rewinding
Supply only GEAR OIL EP 90 HP (SHELLSPIRAX S2 G90 CASTROL HYPOY 90EP) for Air Blower Twin Lobe 400 Cum/Hr of Make Everest Blower & Model M5075.
All as per item no. 33 but Air Silencer & Filter
All as per item no. 33 but Ball Bearing 6305 Single Z Make :-SKF/NBC/GPZ.
All as per item no. 33 but Lip Seal 42/25/6
All as per item no. 33 but Timing Gear
All as per item no. 33 but Oil seal
All as per item no. 33 but O-Ring
All as per item no. 33 but Vacuum measuring gauge
All as per item no. 33 but Oil level gauge
All as per item no. 33 but Ball valve brass 32mm. Make:- Aarti or equivalent
All as per item no. 33 but Butterfly Check Valve Wafer Type PN 1.6, 80mm. Make:-Mitra or equivalent including nut bolts and gasket.
Supply only On load Changeover 4 pole 200 Amp, 415 volt, in Sheet Steel Enclosure type Cat No: CO22000OSOO of ( make: L&T or equivalent )for LT Panels any make & model complete all as specified and directed by Engr-In-Charge .
All as per item no. 44 but On load Changeover 4 pole 63 Amp, 415 volt, in Sheet Steel Enclosure Cat No: CO10630OSOO of make: L&T or equivalent
All as per item no. 44 but Digital type Voltmeter with LED display suitable for 3 phase with accuracy class 1 Cat No: WL132010OOOO of make: L&T or equivalen
All as per item no. 44 but Digital type Ammeter with LED display suitable for 3 phase with accuracy class 1 Cat No: WL131010OOOO of make: L&T or equivalent
All as per item no. 44 but Tape wound ring type Current Transformer suitable for Bar primary of rating 200/5 Amp, burden 5 VA of make: Kappa/ Matrix or equivalent
All as per item no. 44 but 3 pole power contactor 415 volts with AC 1 rating 45 A & AC 3 rating 25 A with 1 NC Aux contact of make: L&T, Cat No CS94110 or equivalent in Schneider/ Siemens
All as per item no. 44 but 3 pole power contactor 415 volts with 30 Amp AC3 duty rating 1 NO or NC and type MNX18 of make: L&T, type ML-4, Cat No CS94100 / CS94101 or equivalent in Schneider/ Siemens
All as per item no. 44 but Thermal overload relay of Capacity range 4.5-7.5 Amp with MN 2 (Directly operated ) of make:L&T, and Cat No SS94141OOUO or equivalent in Schneider/ Siemens
All as per item no. 44 but Thermal overload relay of Capacity range 6-10 Amp with MN 2 (Directly operated ) of make: L&T, and Cat No SS94142OOVO or equivalent in Schneider/ Siemens
All as per item no. 44 but Thermal overload relay of Capacity range14-23 Amp with MN 2 (Directly operated ) of make : L&T, and Cat No SS94144OODO or equivalent in Schneider/ Siemens
All as per item no. 44 but MCCB 4 pole 160 Amp, 415 volt, 25 kA Cat No: CM90642OONO of make: L&T or equivalent in Schneider/ Siemens
Supply only MBBR media fluidised type of existing nature
Supply only Activated Carbon Media including removing of old media from tank and cleaning of tank complete with suitable chemicals
Supply only Stailness Steel 304 Grade Bar Screen 25X5mm thick flat (removable type ) in 2 mesh size (1 small & 1 big mesh )
Supply only Sodium Hypo Chlorite Liquid (10% chlorine content) in 50 Litre drum for dosing system, disinfection & chemicals with testing certificate [Note- Drums will be returned to the contractor after consumption of chemicals if any as specified and directed by Engr-in-charge]
All as per item no. 60 but Poly Aluminium Chlorite (PAC) Liquid (10% Al2O3 content, PH:3-5) in 50 Kg drum
All as per item no. 60 but Polyelectrolyte (10% concentration solution) in 25 Kg bag of Make: Acuro or equivalent.
All as per item no. 60 but Dosing Tank cylindrical vertical with closed top of capacity 1000 ltr
All as per item no. 60 but Dosing Tank cylindrical vertical with closed top of capacity 500 ltrs
Supply only Weighted suction line strainer 3/8", Part no.- ST138 of (make: Declibac or equivalent) for Dosing plants of chemicals (PE,PAC,Sodium Hypochlorite)
All as per item no. 65 but 3/8" white suction/discharge tubing, Part no.- MALT002 of make: Declibac or equivalent
All as per item no. 65 but Check valve duckbill only (PK-5), Part no.- MCCVDBO of make: Declibac or equivalent (pack of 5)
All as per item no. 65 but Connecting nut 3/8", Part no.- MANUT00 of make: Declibac or equivalent
All as per item no. 65 but Connecting nut 3/8" with adapter(PK-5) , Part no.- MCADPTR of make: Declibac or eqvlt (pack of 5)
All as per item no. 65 but Ferrule 1/4" (PK-24), Part no.- MCAK200 of make: Declibac or equivalent (Pack of 24)
Supply only Butterfly 80 mm bore PN 10 of (Make:- L&T and Castle or equivalent.) valve 'ISI marked' both ends flanged and drilled cast iron including necessary nut bolts and gasket
All as per item no. 71 but Butterfly 100 mm bore PN 10 of Make:- Castle or equivalent.
All as per item no. 71 but Sluice 80 mm bore PN 1.6 of Make:- BIR or equivalent.
S&F FR PVC Insulated Single core unsheathed Industrial Flexible cable of size 16 sqmm conforming to IS 694:2010 with bright annealed copper conductor in existing panel including taking out of old one all as specified and as directed . Make : Polycab or equivalent .
Collection of water samples of STP located in different pockets of cantonment area in decontaminated sterilised bottles and testing of water samples for following essential parameters as per IS:10500- 2012 from Govt Lab or NABL accredited laboratory: - (i) pH value (ii) Ammonical Nitrogen ( mg/lt) (iii)Total suspended solids (mg/lit) , (iv) Chemical Oxygen Demand (COD) mg/lit , (v) Biological or Biochemical oxygen demand (BOD) mg/lit (vi) Faecal Coliform (MPN/100 ml) (vii) Esseceria Coli (E Coli) (viii) Total Phosphorous (mg/ltr) (ix) Total Nitrogen (mg/ltr) all as specified and as directed .
Cleaning of Under Ground sewage disposal Sump every alternate month (total six times in the contract period) internally as well as externally of capacity upto 10000 gallons after pumping out of residual sewage/ water with opening of choked/jammed suction/delivery all lines of sewage pump in sump well ( size upto 10 mtr dia and 10 mtr depth max) fitted with submersible sewage pumpset of capacity upto 12.5 HP including removing deposit, sand from inside the sump by rodding , air presure or other mechanical means , scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus/ algae/ vegetation, filling of cavities inside and outside of tank with cement mortar 1:3 mixed with quick settling chemical and applying one coat of white wash inside including top side by rodding. Any other work reqd for cleaning includes elctrician work, plumbing works or mechanical means reqd if any is deemed to be included in quoated rate & writing date of cleaning outside complete all as specified and directed. [Note :-(i) Under Ground Sump include sewage disposal sumps of Punjab Niwas, OGB-32, Himachal Niwas and Kandhar line (ii) All type of T&P including portable non-clog pump for pumping out residual water before cleaning and Labour etc shall be arranged by the contractor and rate for the same deemed to be included in the quoted rate. (iii) Contractor will dispose off the material taken out from the installation at a distance upto 50 Mtr as directed by Engr-in-Charge.]
M&L for Star HD Flex Electric Shock & it's Management/ Fire order/ SOP Chart showing the Effects, Management, Precautions against electric shock of dimension (90cm×60cm) fixed on Iron square bar Frame (90cm×56cm×2cm) welded together at each end screwed with 2 Hooks for fixing on the wall all as directed by Engr-in-Charge
M&L for Star HD Flex 120cmx60cm showing description of Single Line Diagram of Plant and Machinery Chart having varous tanks,beds,dosing system & motor coupled Pumpsets and Generators wherever installed all as directed by Engr-in-Charge
Supply only lead acid battery 12 volt 180 Ah including initial charge of make: Exide or equivalent complete all as directed by Engr-In-Charge
M&L for Rolled mild steel in Joist ,channel,angle, or tee sections, fixed independently, without connecting plates, etc. for repair to staircase,hand rails and back rest of STP or as otherwise directed. [Note: All T&P and labour charges including weldind work for working on STP deemed to be included in the quoted rate]
M&L for applying two coats of synthetic enamel paint on MS,CI pipes, sluice valves,railings,staircase as per existing colour of both STPs and sewage disposal plants complete after preparing of old surfaces complete all as specified and directed by Engineer-in-charge. [Note: - (i) Different colours as per existing shall be applied as per standard colour code and cost of the same deemed to be included in the quoted rate.]
Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI strip 32x6mm by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI strip is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the equipment. Cement concrete chamber of PCC ( 1:3:6 ) type C-2 using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate, excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009).
His And Her Enterprises
Avion Industries
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .