Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.3 LAccepted-AOC 222 346 LUKERGANJ LUKERGANJ LUKERGANJ ALLAHABAD UTTAR PRADESH 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | 1 | Accepted-AOC L1 | |
| 2 | 2₹3.4 L+₹12,170 (3.68%)Rejected-AOC 257 132 KRISHNA NAGAR KYDGANJ PRAYAGRAJ | 2 | Rejected-AOC L2 | |
| 3 | 3₹3.5 L+₹15,390 (4.66%)Rejected-AOC 16F 1K NEW MARKET BAMRAULI NEAR BAMRAULI RAILWAY STATION ALLAHABAD UTTAR PRADESH 211012 | PRAYAGRAJ | UTTAR PRADESH | 211012 | 3 | Rejected-AOC L3 |
Tender Value
₹3.4 L
EMD Value
₹4,000
Closing Date
22 Oct 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Superintending Engineer Electricity Transmission Circle I 57 George Town Prayagraj 211002
Auto mode operation of marshalling box and repairing of cooling fans of power T/F installed at various 220 KV 132 KV Substations under Electy. Trans. Division- Pratapgarh
2024_UPTCL_962328_1
23-ETC-I(A)/ 2024-2025
Open Tender
Miscellaneous Works
Item Rate
60 days
Pratapgarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
SE,ETC,PRAYAGRAJ
₹4,000
18 Jan 2025
3 Oct 2024
23 Oct 2024
3 Oct 2024
22 Oct 2024
3 Oct 2024
Amount
Supply and fixing of 3NO+1NONC three phase contractor for cooling Fan(pick up potential 250V/AC/9A) of standard of standard make.
40 MVA (Technical) T/F -I &II at 132KV S/S Raniganj
40 MVA (ACCURATE) T/F -II at 132KV S/S Patti
63 MVA (ADITYA) T/F-II at 132KV S/S Pratapgarh
40MVA (AREVA ) T/F-II AT 132KV S/S Lalganj
40MVA (ACCURATE ) T/F-III AT 132KV S/S Lalganj
40 MVA (Technical) T/F -I &II at 132KV S/S Raniganj
40 MVA (ACCURATE) T/F -II at 132KV S/S Patti
40MVA (AREVA ) T/F-II AT 132KV S/S Lalganj
40MVA (ACCURATE ) T/F-III AT 132KV S/S Lalganj
Supply and fixing of 3-phase MCB (4POLE/415VOLT AC/32A)
40 MVA (Technical) T/F -I &II at 132KV S/S Raniganj
40 MVA (ACCURATE) T/F -II at 132KV S/S Patti
40MVA (AREVA ) T/F-II AT 132KV S/S Lalganj
40MVA (ACCURATE ) T/F-III AT 132KV S/S Lalganj
Supply and fixing of overload relay for fan and motor (6-12amp)
40 MVA (Technical) T/F -I &II at 132KV S/S Raniganj
40 MVA (ACCURATE) T/F -II at 132KV S/S Patti
63 MVA (ADITYA) T/F-II at 132KV S/S Pratapgarh
40MVA (AREVA ) T/F-II AT 132KV S/S Lalganj
40MVA (ACCURATE ) T/F-III AT 132KV S/S Lalganj
40 MVA (Technical) T/F -I &II at 132KV S/S Raniganj
40 MVA (ACCURATE) T/F -II at 132KV S/S Patti
40MVA (AREVA ) T/F-II AT 132KV S/S Lalganj
40MVA (ACCURATE ) T/F-III AT 132KV S/S Lalganj
Supply and fixing of terminal block(415v/AC/32A)
40 MVA (Technical) T/F -I &II at 132KV S/S Raniganj
40 MVA (ACCURATE) T/F -II at 132KV S/S Patti
40MVA (AREVA ) T/F-II AT 132KV S/S Lalganj
40MVA (ACCURATE ) T/F-III AT 132KV S/S Lalganj
Revinding & Overhauling Of Three Phase, 150W/240W/410W, (0.3-0.4 Amp.), (1400/700 Rpm) Aditya Ltd., Technical Associate, Amco Ltd., Accurate, Alstom Ltd. Etc. 0.5Hp Cooling Fan Of 20/40/100 Mva T/F At Deffrent Following Primary Sub Stations Under Etd Patapgarh
Cheeking out of dismantling the burnt winding/ coil & damaged three phase cooling fan from the primary sub-station under ETD-Pratapgarh as giving below. The job includes proper testing & identified the rout case not running of cooling fan of power T/F, carriage of above damaged cooling fans from substation to contractor work shop the man, test kit T&O Provided by contractor & his cost the details or giving below.
Rewinding & repairing of three phase, 150W/240W/410W, (0.3-0.4 amp.), (1400/700 rpm) . 0.5hp cooling fan of 20/40/100MVA T/F by super enamelled coper wire work include removing the burnt coil, replacement of damaged barring with new one if found proper oiling & greasing in the moving parts of the t/f cooling fans at different primary sub-station under ETD-Pratapgarh. The detail of giving below.
Fixing of above Repair & rewinding T/F cooling fans with proper connection of three phase supply for proper operation of cooling fans at different primary substation under ETD-Pratapgarh as mentioned above, work includes carriage of require fans from contractor workshop to substation fixing of safe guard of fan with nut-bolt. All man & T&P provided by contractor at this cost.
220 KV Sub-station Pratapgarh 100MVA T/F-I & II, (2 No.)
132 KV Sub-station Gadwara 20 MVA T/F (4 Nos.)
132 KV Sub-station Raniganj 40 MVA T/F-I & II (1 NO.)
132 KV Sub-station Patti 40 MVA T/F-II (3 Nos.)
132 KV Sub-station Lalganj 40 MVA T/F-I, II & III (5 Nos.)
220 KV Sub-station Sangipur 40MVA T/F-I, 160MVA T/F-I & II, (9 No.)
132 KV Sub-station Kunda 63 MVA T/F-II (2 Nos.)
M/S Maa Enterprises
R.S.ASSOCIATE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .