Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-Finance | L1 | Accepted-Finance qualified as L1 | |
| 2 | L2₹3.2 L+₹15,087 (5.01%)Rejected-Finance | L2 | Rejected-Finance Not qualified |
Tender Value
₹2.9 L
EMD Value
₹5,878
Closing Date
30 Sept 2024, 3:00 pmClosed
Executive Engineer (E), BSNL, Bhubaneswar
Room No 317 3rd floor Door Sanchar Bhawan, Unit-IX, Bhubaneswar-751022
Electrical repairing and Maintenance works
2024_BSNL_208992_1
NIT NO. 28/BSNL-EDB/2024-25
Open Tender
Electrical Works
Item Rate
90 days
Door Sanchar Bhawan BBSR
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
A O (Cash), BSNL, O/o GMTD, Bhubaneswar
₹5,878
Yes
10 Oct 2024
21 Sept 2024
1 Oct 2024
21 Sept 2024
30 Sept 2024
21 Sept 2024
21 Sept 2024 - 27 Sept 2024
Amount
Replacement of following faulty SDFU switches by new ones after dismantling the old defective ones, i/c fixing, connection & testing etc. as required.
32 Amps SPN main switch in Sheet steel enclosure with rewirable type porcelain cut out & fuses. (Make: L&T , /Havells / Standard) .
63 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses.(Make: L&T FN type, /Havells / Siemens) .
125 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses. (Make: L&T FN type, /Havells / Siemens) .
250 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses, confirming toIEC 60947-3, IS/IEC60947-3 . (Make: L&T FN type, /Havells / Siemens) .
315 Amps 415 volts TPN SDFU of open execution type with DIN type HRC fuses, confirming toIEC 60947-3, IS/IEC60947-3 . (Make: L&T FN type, /Havells / Siemens) .
Replacement of following faulty / damaged electrical accessories/components by new one suitable for operation on 230 volt 50 hz AC Suppy i/c testing etc. as required.
36 /40-watt Fluorescent Tube rods
36/40-watt electronic ballast for Fl. Tube fittings
Starter for Fl. Fittings
20/22W Ultra bright LED Tube light with very high efficacy >=115 lm/W & THD<10% suitable for installation in existing tube light G13 lamp holders to give glare free light.
20/22 watt 65000K LED Batten Polycarbonate/Aluminium body
Angle/batten Holder
Ceiling Rose
18 watt 6500K LED panel (Round/Square) (Trim Clipon LED panel of Havells/SS)
15 watt BC LED Lamp
Replacement of following faulty / damaged electrical accessories/components by new one suitable for operation on 230 volt 50 hz AC Suppy i/c testing etc. as required.
63 Amps HRC fue with fuse holder & fuse base. (M/s L&T or s.s. make)
15/16 Amps 250 volt 3 pin Top ( M/s Anchore /Cona/ or s.s. make)
5/6Amps 250 Volts 3 pin Plug top ( M/s Anchore /Cona/ or s.s. make)
6 /10 Amps 1 way piano type switch
16 Amps 1 way piano type switch
6 Amps 3 pin piano type socket
16 Amps 3 pin piano type socket
Calling bell / buzzer ( Cona or s.s. make)
Replacement of the burnt out wires /wirings by the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 sq. mm
2 x 1.5 sq. mm
3 x 1.5 sq. mm
4 x 1.5 sq. mm
2 x 4 sq. mm
Replacement of damaged conduits by the following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Rewinding of 1200mm/1400mm ceiling fan by superior quality super enameled copper conductor i/c heat varnishing, testing etc. as required.
Overhauling of Ceiling Fan i/c dismantling, heat varnishing of windings, greasing of bearings, refitting, testing etc. as required.
Replacement of following defective spares for ceiling fans by the new one etc. as required. (Make- Anchor/Havells/Cona/ISI)
2.25 mfd Capacitor for Ceiling Fan
Bearings for Ceiling fans (6201 & 6202) etc. as required. (Make: SKF/SS)
Ceiling Fan hanging Clamp with nuts and bolts
5 stepped type electronic fan regulator on the existing switch box including connections etc. as required. (2M)
Replacement of damaged and life expired ceiling fans by new ones of 1200 Ceiling Fans for the Officers Quarters i/c installation, connection and testing etc. as required. (Havells Elegant White Or Equivalent of Usha/Bajaj/Crompton)
Providing 380 mm size exhaust fans for the toilet i/c installation, connection and testing etc. as required. (Havells Veltil Air DX HS Or Equivalent make of Usha/Bajaj/Crompton)
Replacement of following damaged SPN/TPN type sheet steel, MCB distribution board by new one suitable for operation on 240V /415 V, 50 hz, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make-Legrand/L&T/Siemens/Schneider)
8 way, Double doortype SPN DB
10 way, Double door SPN DB
12 way, Double door SPN DB
Supply and fixing 4 way (4 + 12) horizontal type 3 phase and neutral MCB distribution board of sheet steel, IP-43 with metal door, suitable for flush mounting and surface mounting, with 100Amps copper bus bar for each phase with neutral bar, earth bar and cable ties for cable management, fully insulated busbar & shrouded neutral bars, pre-fitted masking sheet, reversible door with provision for fixing four pole MCB/Isolator /RCCB/RCBO as incomer and SPMCB's as outgoing etc. as per IEC 61439-3 and grouting in wall as required.(Make: Legrand/ L&T / Schneider Electric/ Siemens / ABB)
Replacement of faulty MCBs, Isolators by following rating, suitable for operation on 240/415 V, AC supply complete with connections, testing and commissioning as required.(Make M/s Standard, Havells, Legrand S.S. Make)
6-32 A Amps rating SPMCB
40 A Double Pole Isolator
63 A Double Pole Isolator
63 A Four Pole Isolator
100 A Four Pole Isolator
Supplying of following Copper sockets ( Ring/Pin) for end termination in place of damaged ones.
35 Sqmm Copper sockets ( Dowells/Lotus/ or SS make)
25 Sqmm Copper sockets ( Dowells/Lotus/ or SS make)
16 Sqmm Copper sockets ( Dowells/Lotus/ or SS make)
10 Sqmm Copper sockets ( Dowells/Lotus/ or SS make)
6 Sqmm Copper sockets ( Dowells/Lotus/ or SS make)
4 Sqmm Copper sockets ( Dowells/Lotus/ or SS make)
Supplying of following Copper sockets ( Ring/Pin) for end termination in place of damaged ones.
300Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make)
240 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make)
185 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make)
150 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make)
120 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make)
95 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make)
70 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make)
50 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make)
25 Sqmm Aluminium sockets ( Dowells/Lotus/ or SS make)
Supply and Fixing of MCB protected Socket outlet 4 modules with metal box comprising of 01no. 25Amps socket and 01no. 25Amps Plug and 01no. 25Amps "C" series SPMCB for Split AC units’ i/c grouting in wall, connection, testing etc. as required. (Make: Legrand/ L&T / Schneider Electric/ Siemens / ABB)
SITC of 12V sealed maintenance free battery of not less than 7AH capacity with all accessories etc as reqd.(Exide /Amco/Superior) ( For lift operation)
Fault attending & repairing of 15 Litre capacity storage type gyser after dismentaling from the existing position, replacing the faulty spares by new one, reassembling & refixing the same etc as required. (Make: V-guard/ Crompton or s.s make)
Replacing the following faulty spares of 15 litres of geser by new one,i/c testing etc as required.(Make: V-guard/ Crompton or s.s make)
2000 watt heating coil element
Thermostat
Thermal cut
Replacement of faulty 15 Litre capacity storage type gyser by new 5 litre capacity instant heating type after dismentaling the faulty one from the existing position & fixing the new one i/c connection testing etc complete as required. ( for IQ Room No -3)
M/S PRACHI ELECTRICALS (BID ID -751149)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .