| 1 | L1₹4.5 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.4 L+₹65,270 (13.8%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹6.7 L+₹2.0 L (41.9%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹6.7 L+₹2.0 L (42.2%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
5 Jun 2024, 6:00 pmClosed
AGE I AF MEMAURA
AGE I AF MEMAURA
REPAIR MAINT AND REPLACEMENT OF INTERNAL ELECTRIC WIRING FITTING AND FIXTURES IN SMQ AND OMQ AT AF STN MEMAURA
2024_MES_653264_1
8340/E8
Open Tender
Civil Works
Works
183 days
AGE I AF MEMAURA
As per NIT
8 documents required · 8 mandatory
₹500
AGE I AF MEMAURA
₹19,000
Yes
18 Jul 2024
10 May 2024
7 Jun 2024
10 May 2024
5 Jun 2024
24 May 2024
Amount
Taking down carefully copper/Aluminium point wiring (light/fan/socket power) complete of any size, type and including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good to the disturbed surfaces of walls, floors, etc to match with the existing surfaces complete all as directed.
Material and labour for point wiring concealed type with 1.5sq mm PVC insulated unsheathed single core multistranded FRLSH copper conductor cable 1100 volts grade incl. 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through and incl. medium grade PVC rigid conduit not less than 20 mm dia with its accessories, galvanized pressed steel terminal boxes of thickness 1.0 mm covered including 3mm thick laminated sheet cover for fixing switches/ socket/regulators etc for the following: - Note:- (i) On RCC ceiling/column, false ceilling, AC/Metallic Sheet ceilling wiring done on surface with conduit/PVC Casing caping and its accessories. (ii) The quoted rete is deemed to be included for the chases cutting. (iii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
One light/fan/exhaust fan/ Bldg security light point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board.
One socket outlet 6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
One light point controlled by two, two way switches.
All as per item No. 2.00 here-in-before but by using 2.5 Sqmm FRLS copper conductor cable with continuous earth wire of 2.5 Sqmm FR copper conductor for one 3 pin 15 Amp socket outlet point controlled by one switch.
Material and labour for point wiring in PVC casing and caping type with 1.5sq mm PVC insulated unsheathed single core multistranded FRLSH copper conductor cable 1100 volts grade incl. 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drawn through and incl. ISI mark suitable size PVC casing and caping with its accessories, PVC terminal boxes of thickness 1.0 mm covered including 1mm or more thick PVC cover for fixing switches/ socket/regulators etc for the following: -
One light/fan point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board.
One socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 9.00 here-in-before but by using 2.5 Sqmm FRLS copper conductor cable with continuous earth wire of 2.5 Sqmm FR copper conductor for one 3 pin 15 Amp socket outlet point controlled by one switch.
S&F switch modular type 5/6 Amps, 230 V AC, single pole, one way complete all as specified and directed.
S&F socket out let multipurpose modular for 2 pin and 3 pin, 5 Amp flush type with shutter complete all as specified and directed.
S&F switch modular flush type 16/20 Amps, 230 V AC, single pole, one way complete all as specified and directed.
S&F socket outlet, multipurpose, modular 6 pin, 6 /15Amp with shutter complete all as specified and directed.
S&F in repair modular fan regulator electronic type (5 step) , 120W - 2 module complete all as specified & directed.
S & F modular switch 2- way, 5/6 amps flush type 230 volts complete all as specified and directed.
S&F Modular bell push type 5/6 Amps, 230 V AC, single pole, one way complete all as specified & directed.
S&F in repair switch piano flush type 5/6 Amp single pole one way complete all as specified & directed.
S&F in repair socket outlet flush type 5/6 Amp 5 Pin complete all as specified & directed.
S&F in repair switch piano 16/20 Amp flush type 240 Volt complete all as specified & directed.
S&F in repair socket out let 6 Pin 2 in 1, 5/15 Amp flush type 240 Volt complete all as specified & directed.
Supply & fix in repair Switch socket combination unit with box 2 in 1, 3 pin 6/16 Amps flush type universal complete all as specified & directed.
Supply and fix in repair fan regulator electronic type (5 step) complete all as specified and directed .
S&F bell push, flush type, 6 amp 240 volts complete.
S&F ceiling rose three terminals complete.
S&F door bell, ding dong/ multi music, AC, 240 volts, single pole complete.
S&F angle holder, insulated polycabonate body with back plate complete.
S & F modular metal flush box 3 module, complete all as specified & directed.
S & F modular metal flush box 4 module, complete all as specified & directed.
S & F modular metal flush box 6 module, complete all as specified & directed.
S & F modular metal flush box 8 module, complete all as specified & directed.
S & F Modular white cover plate with frame 3 module, complete all as specified & directed.
S & F Modular white cover plate with frame 4 module, complete all as specified & directed.
S & F Modular white cover plate with frame 6 module, complete all as specified & directed.
S & F Modular white cover plate with frame 8 module, complete all as specified & directed.
S&F in renewal LED bulk head luminaire, internally prewired with and including premium quality diffuser for glare free light, 10 watt, Ingress protection IP 65, colour temp - 6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria and connecting the same in electric source with and using PVC sheathed and insulated 3 core copper conductor cable of size 0.50 Sqmm and fixing arrangement for fixing the light fitting complete all as specified and directed.
Supply and fix in replacement of decorative wall mounting type LED light fitting, 1 x 9 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 9 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed.
S & F Wall/surface mounted type LED light fitting batten type complete with LED 1x 18/20 watt (4 feet long), extruded aluminium body with heat sink provided for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with 3 core twisted flexible copper conductor cable complete all as specified and as directed.
S & F Wall / surface mounted type LED light fitting batten type complete with LED lamp 10- watt (2 feet long), poly carbonate body and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with twine core twisted flexible copper conductor cable complete all as specified and as directed.
S&F in replacement metal clad plug & socket DB with plug top including one MCB single pole 20 Amps 240 volts 50 HZ complete all as specified & directed.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed.
All as Item No 44 above but for 3 Phase, 415 volt
Supply and fixing 10 SQMM 2 Core PVC insulated PVC sheathed Aluminium, flame resistant flat cable all as specified and directed.
Material and labour for sub main wiring with 6 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, ISI marked, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 6 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade, ISI marked complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Supplying and fixing in replacement SPN Distribution Board 4 Way,metal double door, neutral busbar, earth bar, din bar, blanking plates in unused spaces etc as required complete all as specified and directed.
All as Item No 48 here - in - before but for SPN DB, 240 volts, 8 ways
All as per item No 48 here - in - before but for 2 way DB single door
Supplying and fixing MCBs Single pole 6 to 32 Amp of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size complete all as specified and directed.
All as Item No 51 here-in-before but for SPN 06 to 32 Amp
All as Item No 51 here-in-before but for SPN 40 to 63 Amp
Note for MCBs & MCB DBs:- MCBs & MCB DBs shall be of the same make. MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces.
S&F 20 W powder coated PPC aluminium LED building light fitting having Ingress Protection class IP-65 , with high power LED complete with 32 mm bore light grade GI pipe bracket (1.5m long) duly bent to shape including 2 Nos M.S. Flat (25mmx5mm) clamps, nuts, bolts, washers etc. all as specified and as directed.
Supply and lay, jointing & testing of cable 10 Sqmm 2 Core XLPE armoured LT 1100 volt grade heavy duty with Stranded aluminium conductor passing through ducts/pipes and run on poles/walls including fixing with proper size of alluminium lugs/saddles and taking down old cable complete all as specified and directed.
VIDYA TRADERS
m/s pal associates
M/S PRATAP ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .