Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹39.4 L Quoted ₹41.0 L | L1 | Accepted-AOC AOC |
| 2 | L2₹41.9 L+₹91,140 (2.22%)Rejected-Finance | ₹41.9 L+₹91,140 (2.22%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹42.6 L+₹1.6 L (3.90%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹42.6 L+₹1.6 L (3.90%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹43.0 L+₹2.0 L (4.80%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹43.0 L+₹2.0 L (4.80%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹43.3 L+₹2.3 L (5.68%)Rejected-Finance SHYAM BHAWAN OPP BANK OF INDIA CHOPASNI ROAD JODHPUR 342003 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342003 | ₹43.3 L+₹2.3 L (5.68%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
9 Jun 2023, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
REPAIR AND MAINT OF STREET LIGHT FITTINGS AND SOLAR LIGHTS AND MISC WORK AT HQ AREA AND VARIOUS UNITS AT MIL STN JAISALMER UNDER GE (A) JAISALMER
2023_MES_595349_1
8291/23-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Army Jaisalmer
₹98,000
Yes
1 Sept 2023
13 May 2023
16 Jun 2023
13 May 2023
9 Jun 2023
26 May 2023
Amount
Supply, laying, testing and commissioning of LT UG ,XLPE insulated, heavy duty, 1100V grade of size 50 Sqmm 3.5 core electric cable with aluminium conductor, served with an inner sheathing of PVC tape armoured eith galvanized steel wire or tape and overall PVC sheathed,laid in trench or passing through pipe, making all connection with and including provision of necessary glands,lugs, bushing etc as required including taking down old unservicable complete all as specified and directed by Engineer-in -Charge of following size:- Note: Earthwork excavation sand cushioning, Jodhpur stone patti, GI protcetion pipe shall be measured and paid separately in their respective items.
All as per item No 1.00 above but size 35 Sqmm 3.5 core
All as per item No 1.00 above but size 25 Sqmm 4 core
All as per item No 1.00 above but size 16 Sqmm 4 core
All as per item No 1.00 above but size 10 Sqmm 4 core
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Removing excavated material soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
M/L for tibba sand for cushioning with layers of sand 8 cm before laying of cable & 15 cm after laying of cable (total 23 cm ) in trenches, duly punning to a thickness of 18 cm for cable protection complete all as specified and directed by the Engineer-in-Charge. Note:- Thickness after punning shall be measured for payment.
M&L for laying 40 to 50 mm thick roughly hammer dressed jodhpur stone patti cable cover 25 cm to 30 cm wide and not exc 60 cm long each laid dry abuting with each other with maximum gap between adjacent patti/ slabs not exc 10 mm complete all as specified and directed by the Engineer-in-Charge.
Supply, transportation fixing and errection of Steel Tubular Swaged poles complete with cast iron base plate, finial taper pulg, bolts, nuts and screws as specified type 410 SP-31 (9.0 meters long) and including making alternate white and black strips 30cm height (Total 05 Nos) with two coats of synthetic enamel paint over a coat primer complete all as specified & directed by Engineer-in-charge.
M&L for plain cement concrete (1:4:8) type D-2 (using 40mm grade stone aggregate) in foundation of pole/struts etc including necessary form work complete all as specified & directed by Engineer-in-charge.
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm grade stone aggregate) in foundation of stay assembly/pole including necessary form work complete all as specified & directed by Engineer-in-charge.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm grade stone aggregate) for coping/encasing around of pole including necessary form work finished and smooth without using extra cementcomplete all as specified & directed by Engineer-in-charge.
S&F led street light of capacity 60 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 100 Lumens/Watt, Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket, Nut, Bolts And Accessories including disconnected & taking down old Unserviceable Light. The Manufacturer of the Led fitting shall have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. all as specified and directed by Engr-in-Charge. Make – Crompton cat No CRP-409-60-57-SL-GL-NSG or equivalent in Appx 'C' list of makes.
S&F led street light of capacity 45 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 100 Lumens/Watt, Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories including disconnected & taking down old unserviceable Light. The Manufacturer of The Led fitting shall have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. all as specified and directed by Engr-in-Charge. Make – Crompton Cat No CRP-409-45-57-SL-GL-NSG or equivalent in Appx 'C' list of makes.
S&F led street light of capacity 30 Watt, Including making electrical connection to the fitting with suitable size of wire,Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 100 Lumens/Watt, Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D < 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ) Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket , Nut, Bolts And Accessories including disconnected & taking down old unserviceable light. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report etc. all as specified and directed by Engr-in-Charge. Make – Crompton Cat No LSTS30 CDL-M or equivalent in Appx 'C' list of makes.
S&F Led Flood Light Fitting 250 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95, Dimensions Of The Fitting Shall Not Be Less Than 345 Mm X 345 Mm X 70 Mm ( Higher Dimensions Can Be Accepted) , Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X …….. Frlsh Wire, complete all as specified and directed by Engr-in-Charge Make : Crompton Cat no CFS-250-57-30 D-HL2-GL-NSG or equivalent in Appx 'C' list of makes.
S&F Led Flood Light Fitting 400 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 48,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95, Dimensions Of The Fitting Shall Not Be Less Than 500 Mm X 345 Mm X 130 Mm ( Higher Dimensions Can Be Accepted) , Cct – 5700k, 2 Nos. Of Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Seperate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X …….. Frlsh Wire, All As Per Directed By Eic all as specified and directed by Engr-in-Charge Make – Crompton Cat no CFS-400-57-30 D-HL2-GL-NSG or equivalent in Appx 'C' list of makes.
S&F PVC sheathed 1100 V grade flat 3 core stranded copper conductor of size 2.5 sqmm including conduit pipe connecting from SMC box to street light fitting and including taking down existing unserviceable cable complete all as specified & directed by Engineer-in-charge.
S&F PVC sheathed 1100V grade flat 2 core stranded aluminium conductor of size 4 sqmm including conduit pipe connecting from SMC box to street light fitting and including taking down existing unserviceable cable complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 40 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 50 mm bore, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCCB 4 Pole 63 Amps, breaking capacity 16 KA, thermal & magnetic adjustable type, 415 volts with connection link on LT panel /fedder piller including taking out existing UNSV / burnt MCCB complete all as specified and directed by Engineer-in-charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 Pole 100 Amps, breaking capacity 16 KA, thermal & magnetic adjustable type, 415 volts with connection link on LT panel /fedder piller including taking out existing UNSV / burnt MCCB complete all as specified and directed by Engineer-in-charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 Pole 125 Amps, breaking capacity 16 KA, thermal & magnetic adjustable type, 415 volts with connection link on LT panel /fedder piller including taking out existing UNSV / burnt MCCB complete all as specified and directed by Engineer-in-charge. (Note: ICS = ICU 100%).
Supply and fixing MCCB 4 Pole 250 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with connection link on LT panel /fedder piller including taking out existing UNSV / burnt MCCB complete all as specified and directed by Engineer-in-charge. (Note: ICS = ICU 100%).
S&F in repair miniature circuit breaker (MCB) of single pole SP 6-32 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
S&F in repair miniature circuit breaker (MCB) of single pole and neutral SPN 32 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB/ Panel box/ feeder piller box complete with connection testing and commissioning.MCB, TPN 40 Amp, including dismantling existing MCB complete all as specified and directed by Engineer-in-charge.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB/ Panel box/ feeder piller box complete with connection testing and commissioning.MCB, TPN 63 Amp, including dismantling existing MCB complete all as specified and directed by Engineer-in-charge.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB/ Panel box/ feeder piller box complete with connection testing and commissioning.MCB, TPN 100 Amp, including dismantling existing MCB complete all as specified and directed by Engineer-in-charge.
S&F galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete for fixing street light fittings and including taking down existing bracket of any description complete all as specified and directed by Engineer-in-charge.
Disconnecting and taking out existing SMC of any size and in any position on pole and Supply & fix in repair sheet moulding compound junction (SMC) suitable for terminating 2 Nos 4 x 6/10/16 Sqmm UG cable including S&F of one in Nos MCB SP 6-32A including cable glandes- 2 Nos, and two way connector 1 No, including dismantling old one complete all as specified & directed by Engineer-in-charge.
Material and labour for straight through (Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm including dismantling the old burnt cable joint termination complete all as specified & directed by Engineer-in-charge.
Material and labour for preparation of old painted surface of LT Concrete electric pole of any size by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos), including painting the cross arms/bracing support on poles with a coat of aluminium paint, silver colour aluminium paint with coating of primer and writing of identification Nos with proper stencil cut etc complete all as specified & directed by Engineer-in-charge.
Material and labour for preparation of old painted surface of LT Steel tubular pole of any length by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing support on poles and writing of identification Nos with proper stencil cut etc complete all as specified & directed by Engineer-in-charge.
Material and labour for preparation of old painted surface of F/P box/LT Panel by removing all dirt, dust, etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour over a coat of primer including writing of identification with proper stencil cut etc complete all as specified & directed by Engineer-in-charge.
S&F Lithium based energy efficient Integrated solar street light of 20 watt in single FRP body with duly polyurenthane coating encases with monocrystalline solar PV panel of 30/35Wp, Lithium battery 11.1/12.8 Volt, 19.8 Ah with inbuit BMS, IP 65, High brightness W-LED (160-180 Im/Watt) lamp with aluminium reflector for better lighting distribution, CRI 70, colour temperature 5700 K-6500 K, Microcontroller based charge controller cum driver, automatic dimming function with PIR motion sensor,Dusk to dawn operation weight not more than 10-12 KG with adjustable MS Clamp suitable for existing pole/wall mounting etc and including taking down existing light complete all as specified & directed by Engineer-in-charge. Note : Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & TOHS complaint.
Supply and fix Din type HRC fuse link of Required rating 32A/63A/100A Suitable for HG type 20H/2 and including taking out existing fuse of any description complete all as specified & directed by Engineer-in-charge.
S&F Advance Microcontroller and real time clock base astronomical timer panel suitable for 3 phase 415v,AC having 8 bit micro controller with inbuilt battery,16 character two line LCD display, input isolator 125 Amp 4 pole and 3 Phase output with 6 Nos, 32Amps MCB SP and with complete copper conductor power wiring of suitable size, contactor 63 Amps, 4 Pole-03 Nos, inside 2mm (16/18 guage) thick feeder panel duly power coated complete with 40X40X5mm 45CM height angle iron structure with PCC complete suitable for 30 KVA load and including taking out existing timer switch of any description complete all as specified & directed by Engineer-in-charge.
Supply & fix DX3 Power contactor suitable for power supply 40 Amps 4 pole 4 NO Contactor including making electrical connection to the contactor and including taking out existing power contactor complete all as specified & directed by Engineer-in-charge.
Supply & fix DX3 Power contactor suitable for power supply 63 Amps 4 NO Contactor including making electrical connection to the contactor and including taking out existing power contactor complete all as specified & directed by Engineer-in-charge.
Labour only for attending street light complaints and rectifying the faults viz non ops & flickering of street light, Cable or service wire damage, earth leakage & electric shock in street light poles & panel, hanging or bending of street light etc up to entire satisfaction of Eng-in-Charge including all necessary petty items like lugs, nut, bolts, screws and any type of tool required. Note:-Group of complaints for one feeder will be consider as one job. Complaint slip will printed and supplied by contractor in prescribed format as specified at the time of commencement of contract as directed by Engr-in-Charge.
Supply and fix in repair for the following parts for LED fitting complete all as specified & directed by Engineer-in-charge.
(a) Electronic Driver suitable for Capacity 45 Watts
(b) Electronic Driver suitable for 60 Watts
c) Electronic Driver suitable for 30 Watts
d) Electronic Driver suitable for 90 Watts
Supply and Fixing in repair of Surge protection device 10 KV Suitable for LED Street lights capacity 30 Watt to 90 Watt sle, single phase, 230 volts, 50 Hz complete all as specified & directed by Engineer-in-charge. Note : Contractor has to arrange telescopic boom lift for maintenance at height of 15m at his own cost. No extra payment will be paid by department.
Supply, installation, testing and commissioning LT Feeder pillar/Panel board cubical type outdoor conforming to IS 8623 Part 1 1993 ,factory fabricated out of 3.15 mm thick CRCA sheet & suitable size to accommodate all acceessories / fitting , compartmentalized in construction to accomodate incoming and outgoing, MCCB, MCB and TPN Aluminium Bus bar of rating not less 1.5 times the rated capacity of incomer MCCB/ACB and outdoor feeder. The TPN bud bar shall insulated with color coded heat shrinkable sleeve and shall be mounted on DMC/ Epoxy insulators of suitable size through out the length of TPN bus bar. The incoming as well as outgoing MCCBs shall have copper extension link of current carrying cap not lass than 1.5 times the rated capacity of individul feeders. The extension link shall be supported on DMC /Epoxy insulators having provision for termination of incoming and outgoing cables .
ITEM NO. 47.00 CONTD... All extension links / interconnection shall be insulated with heat shrinkable colour code sleeves. The cubical shall have a bottom channel of size 50x50X5 mm and and 45 cm height above the ground level duly fixed with PCC . a detachable predrilled gland plate of thickness not less than 3 mm thick should be used at a bottom for enrty of armoured cable of adequate size with glands. The above panel shall be front and back openable /lockable by the key from both side and shall have louvers and air vent gasket for natural floe of air. XLPE adhesive type gasket shall be used to make the panel weather, dust and vermin proof with IP 65 degree of protection, complete as specified and consisting the following switchgears and accessories.:-
ITEM NO. 47.00 CONTD... (a) 4 No's alumnium bus bar of rating 400 Amps mounted on heavy duty rubberised/porcelene support two set (Vertically and horizontaly) (b) Incoming MCCB 4 pole ,250 Amp 415 Volts , 36 kA rupturing capacity ,with adjustable setting 80% to 100 % thermal magnetic release -01 No (Ics =100%Icu) (c) Outgoing MCCB 4 pole ,160 Amp 415 Volts , 16 kA rupturing capacity ,with adjustable setting 80% to 100 % thermal magnetic release -01 No (Ics =100%Icu) (d) Outgoing MCCB 4 pole ,100 Amp 415 Volts, 16 kA rupturing capacity, with adjustable setting 80% to 100 % thermal magnetic release -02 No (Ics =100%Icu)
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground levl connected to galvanized iron strip 32 x6 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection all necessury earth work ,excavation ,earth chamber with PCC 1:3:6 type C2 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on completion complete all as specified & directed by Engineer-in-charge.
Material and labour for cutting the existing bituminious road / hard standing to size not exceeding 45 CM wide and depth not less than 45 cm for passing UG cable through GI pipe and making good the good distrubed surface and filled excavated material and 200 mm depth with plane cement concrete 1:3:6 type C1 using 20 mm graded aggregate complete all as specified & directed by Engineer-in-charge.
Taking down existing High Mast light fitting complete light with bracket ring along with their control gear with the help of winch at repairable height and taking up at its original height after repair and renewal of unserviceable material complete all as specified & directed by Engineer-in-charge. Note : (i) Item/materials required i.e.driver ballast, igniter, bipin holder, lamp, chock, etc required for measured and paid separately under relevant items under supply only. (ii) Fixing of lamps/tube rod not included in unit rates.
M&L for Marking of Pole Number on PCC/Steel Tubular (HT/LT Pole) with suitable size 15cmx15cm using with sythentic enemal paint colour and using Black colour for Pole numbers etc complete all as specified & directed by Engineer-in-charge.
S & F in repair of battery 12 V, 40 AH with controller suitable for solar lighting system complete all as specified & directed by Engineer-in-charge.
Supply and fix in repair of Solar Charge Controller 5Amp with protection circuits for 16 to 32 watt Solar Light System: 12V Nom inal Capacity: 80Wp Max Regulation: Low Loss, Shunt Type OVD: Output Voltage Drop<200mV at 2.1A Load IVD: Input Voltage Drop<330mV at 10A Charge LVD: Low Voltage Disconnect, 10.8V HVD: High Voltage Disconnect,14.2V LVR: Low Voltage Reconnect, 12.3VHVR: High Voltage Reconnect, 14.15V Battery Charging Type: PWMProtections: Short Circuit and Overload at load Reverse polarity of battery and panel complete all as specified & directed by Engineer-in-charge.
Supply and fix in repair of of PIR Motion Sensor 170 uA for 12 to 60 watt Solar Light Standard Detection 5m Lens Color : White complete all as specified & directed by Engineer-in-charge.
Supply & Installation of Lithium Battery 11.1V/ 28.6 Ah (Suitable for 16 to 24Watt solar light) with BMS Circuit and other necessary wires and connectors suitable for 16 to 24watt Integrated Solar Lights complete all as specified & directed by Engineer-in-charge.
Supply & fixing in reapir of Rocker Switch 6 to 10Amp for solar lights complete all as specified & directed by Engineer-in-charge.
Supply and Fix Retro Reflective Tape 3 inch width red and yellow colour sutiable for steel tubular pole and RCC Pole complete all as specified & directed by Engineer-in-charge. Note : Contractor has to arrange telescopic boom lift for maintenance at height of 15m at his own cost. No extra payment will be paid by department.
Note : (a) Contractor has to arrange his own vehicles along with mounted hydraulic ladder/articulated & telescopic boom lift arrangement for attending the complaint throughout jaisalmer cantt area. (b) Contractor shall depute minimum 2 staff daily to attend and rectify the complaint. if not, Contractor shall have to bear a penalty of Rs 50.00 per complaint or maximum of Rs 500 per day on this account (c) Complaints has to attend and rectify the complaint/defect irrespective of no of trips/Complaints as alloted by Eng-in-Charge.(d) Complaint should be attend in Night also.
HARSH CONSTRUCTION CO.
M/s Shree Construction Company
SANJOLI CONSTRUCTION COMPANY
Shri Maruti Trading Co.
M/s Yash Electrical and Maintenance
Manisha Enterprises
Anil Builders
SHRI HARI CONSTRUCTION
OLIVE EXPORTS PVT LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .