Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹23.3 L+₹14,471.53 (0.63%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹25.1 L+₹2.0 L (8.48%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹25.4 L+₹2.2 L (9.67%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹25.4 L+₹2.3 L (9.87%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
30 Mar 2021, 6:00 pmClosed
Sh ARJUN PATRO,GE (U) Elect Supply
GE U ELECTRIC SUPPLY DELHI CANTT
MANNING AND OPERATION OF 11 KV SUB STATION AT TODAPUR DHAULAKUAN PART I REPAIR REPLACEMENT OF LT PANELS MCCBS CONNECTED ITEMS IN THE AREA OF CARRIAPPA VIHAR DHAULAKUAN PARTI UNDER AGE U ELECT SUPPLY NO II UNDER GE U ELECTRIC SUPPLY DELHI CA
2021_MES_422440_2
GE ELECT/D-109/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE U ELECTRIC SUPPLY
₹70,000
Yes
12 Apr 2021
17 Mar 2021
1 Apr 2021
18 Mar 2021
30 Mar 2021
25 Mar 2021
Amount
Manning and Operation in Receiving-cum-Distribution Stn 11 KV round the clock by deployment of electrician in three shifts as specified, including Sunday and holidays under the concerned area under GE (U) E/S Delhi Cantt as per the schedule below :- Todapur Sub Station (11 KV) :- (a) 1st shift from 0800 hrs to 1600 hrs. One Electrician. (b) 2nd shift from 1600 hrs to 0000 hrs. One Electrician. (c) 3rd shift from 0000 hrs to 0800 hrs. One Electrician. Dhaula Kuan Part I Sub Station (11 KV) :- (a) 1st shift from 0800 hrs to 1600 hrs. One Electrician. (b) 2nd shift from 1600 hrs to 0000 hrs. One Electrician. (c) 3rd shift from 0000 hrs to 0800 hrs. One Electrician. .
Note : (i) The contracotor will ensure suitable repalcement of electrician while on leave/weekly holidays and Wages for the same deemed to be included in the quoted rate. (ii ) The contractor shall ensure that electricians/ operator always be present in each shift. In case of absence of any worker the penalty @ Rs 100.00 per hours per electricians/ operator shall be imposed on the contractor. (iii) The contractor shall be responsible for maintaining the complete area (i.e. inside boundary wall ) such as building , hard standing , foothpath etc in neat and clean position . All necessary T&P for cutting /cleaning of grass and vegitation will be arranged by contractor without any extra cost. (iv) The contractor shall provide uniform , raincoat, protective clothing such as hand gloves ,helmet, safety belt , first aid box and shoes etc to all persons on duty and the cost of the same is deemed to be included in quoted rate. (v) Person employed should be working experience of working on HT and LT Installation. (vi) The contractor shall provide log sheet and maintain the the same on daily basis and the cost of the same is deemed to be included in quoted rate.
Worker's wage per person per day per shift (inclusive of GST as applicable)
Employees Provident Fund as per existing rules (Prescribed Rate of EPF as applicable on (minimum wages without GST ) + GST Rate as applicable on Prescribed Rate of EPF as applicable on (minimum wages without GST )
Employees state insurance as per existing rules. (Prescribed Rate of ESI as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of ESI as applicable on (minimum wages without GST )
Contribution of Bonus as per existing rules. (Prescribed Rate of BONUS as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of BONUS as applicable on (minimum wages without GST)
Over head & profit on total of srl No 1.02 to 1.05 as applicable.
LWC as per existing rules on total of srl no 1.02 to 1.06. The bidder should note that the minmum wages including all statutory provisions as mentioned in item no 1.02 to 1.06 are exclusive of GST for calculating of labour cess.
NOTE For Item 1 and sub items :- (a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, ie proof of payment. (b)The rate quoted shall not be less than minimum wages as notified by Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc as applicable and also not less than applicable rates for contribution of employer towards EPF,ESIC, BONUS and LWC under respective heading /subitems. In case the rates quoted are less than the minimum wages as notified by the Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc on the last due date of bid submission. his tender will be treated as non bonafide and will not be considered for acceptance.In such case,the lowest bidder shall be determined from amongst the valid/bonafide bids only. (c) 'NIL' or 'Zero' quoting against OH & Profit will be treated as 'Non-bonafide'.
(d) Contractor is required to quote upto two digits after decimal place or otherwise it will be consdered by rounding off to two digits after decimal place in accordance with Rules for Rounding off of Numerical Values in accordance with IS:02 OF 1960(Revised 2016) of BIS. (e) Any variation in minimum wage, liability of EPF/ESIC/Bonus/LWC/GST shall be adjusted for reimbursement/recovery as under:- (i) Variation in minimum wage including other related statutory provisions shall be adjusted in terms of Condition 63 of GCC (IAFW-2249). (ii)Variation in percentage/rate of GST and LWC shall be adjusted as per instructions in Annexure XVI of MES Manual on Contracts which deals with ‘Reimbursement/Refund on Variation in Taxes Directly Related to Contract Value’
Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of size 450mm x 450mm x 300mm with 4 Nos 500 Amps aluminium bus bar and with 250 Amp MCCB, 4 pole, 36 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level. (Location : UE-01, CV-01 )
Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT Panel board of size 700mmx900mmx1450mm, cubical compartmentalized , out door type double door , mounted on angle iron legs 50x50x6mm thick, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system accomodated with 01 No ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type motorized, front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection fitted with aluminium bus bar link 1200 Amps for incomming and outgoing cable connection. The panel shall be dust and vermin proof. IP-65 class protection and shall be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement . including excavation, earth work and platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. (Location : 1 WEC Sub Stn)
(b) Outgoing (i) MCCB 4 pole , 250 Amps, 50 Hz,415 Volts, 36 KA with thermal magnetic release - 02 Nos (ii) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA with thermal magnetic release - 02 Nos (iii) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 36 KA with thermal magnetic release - 02 Nos (c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer r
S&F in replacement of UNSV /Burnt MCCBs of capacity 630 Amps, TP, 50 KA, 415 Volts 50 Hz, AC, with thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed.
All as per sel item No 7 here in before but rating of MCCB 400 Amp, 36 KA
All as per sel item No 7 here in before but rating of MCCB 250 Amp, 35 KA
All as per sel item No 7 here in before but rating of MCCB 200 Amp, 25KA
All as per sel item No 7 here in before but capacity MCCB 125 Amp, 25 KA
All as per sel item No 7 here in before but capacity MCCB 160 Amp, 25 KA
All as per sel item No 7 here in before but capacity MCCB 100 Amp, 25 KA
S&F in replacement of UNSV /Burnt MCCBs of capacity 630 Amps TPN , FP, 50 KA, 415 Volts 50 Hz, AC, with thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed.
All as per sel item No 14 here in before but rating of MCCB 400 Amp, FP, 36 KA.
All as per sel item No 14 here in before but rating of MCCB 320 Amp, FP, 35 KA.
All as per sel item No 14 here in before but rating of MCCB 250 Amp,FP, 25 KA.
All as per sel item No 14 here in before but rating of MCCB 200 Amp,FP, 25 KA.
Description all as per sel item No 14 above but rating of MCCB 160 Amp,FP, 25 KA.
All as per sel item No 14 here in before but rating of MCCB 100 Amp,FP, 25 KA.
All as per sel item No 14 here in before but rating of MCCB 63 Amp,FP, 25 KA.
S&F in renewal on load change over switch open execution of capacity 400 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable changeover from panels etc complete all as specified and directed.
S&F on load change over switchopen execution of capacity 250 Amps , 4 pole , 415 volt , 50 Hz mounted on wall with fastner and suitable size of nut and bolts after taking down old existing un serviceable MCCB/SDFU etc complete all as specified and directed.
S&F on load change over switch with SS enclosure of capacity 200 Amps , 4 pole , 415 volt , 50 Hz mounted on wall with fastner and suitable size of nut and bolts after taking down old existing un serviceable MCCB/SDFU etc complete all as specified and directed..
Supply and fixing in renewal of 3 pole power contactor ML-6 Cat No SS90921 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable contactor etc complete all as specified and directed.
Supply and fixing in renewal of 3 pole power contactor MNX-110 Cat No CS94137 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable contactor complete all as specified and directed.
Supply and fixing in renewal of Analog Time switch Cat No J648B1, 240 Volt AC , 50 Hz , mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable time switch complete all as specified and directed.
Material and labour in replacement of Voltmeter 0-500 V digital type as per existing size complete all as per specified and directed.
Material and labour in replacement of Ammeter 0-400 Amp digital type per existing size complete all as per specified and directed
Supply and fixing in replacement of indicator lamp for RYB phases complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel/feeder pillar for 70 sqmm cable to 240 Sqmm cable complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel for 300 sqmm cable to 400 Sqmm cable complete all as specified and directed.
Note : (i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
M/s Adhikari construction co.
Vijay Electricals
Rajindera Enterprises
MV Engineers And Contractors
Microsys Controls India
somyaenterprises
Ridhi engineers and builders
mayur enterprises
ENVIRO TECH SERVICES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .