Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | -1.99% | ₹1.2 Cr | L1 | Admitted-Finance |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
3 Feb 2026, 6:00 pmClosed
EE, ADA, Ajmer
ADA, Ajmer
Beautification Work at Chorasiyawas talab, Ajmer
2026_ADA_531686_1
51/2025-26(3)
Open Tender
Electrical Works
120 days
ADA
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
Yes
ADA, Ajmer
₹2.4 L
Yes
11 Feb 2026
23 Jan 2026
4 Feb 2026
23 Jan 2026
3 Feb 2026
23 Jan 2026
Supply, Installation, Testing & Commissioning of 5 MP Varifocal Bullet Network Camera complete with all required specification and supporting accessories. -1/2.7 inch Progressive Scan CMOS, 2592 × 1944 at 25fps, 2.8 mm Fixed lens, 0.003 Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, BLC, HLC, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage including SD Card up to 256 GB , IP67, Alarm 1 inputs, 1 outputs, Audio 1 inputs, 1 outputs, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Region entrance detection, Region exiting detection, Scene change detection, Face capture, Video tampering, audio exception detection, False alarm reduction through human and vehicle target classification based on deep learning CE, FCC, BIS certified
Supply, Installation, Testing A Commissioning of 16 ch NVR Pre-licencfl, NVR supports upto 40 TB HDD Support, I6ch IP inputs; ; Support ANR tectinology 320mbps incoming bandwidth, supports up to I2MP full channel recordin8; support H.265 compression; l6ch syncronised playback @1080p; support 3rd party caméras ONVIF type; 4K output; minimum 04 sATA HDD Slots; each slot should supppori upio IOTB HDD; Dual gigabit self adoptive Ediemct interface; serial inteface; USB interface; (all cameras and Storage-NVà should be of same mie tot the smooth functioning of the system).complète with mounting accessories & junciion box (to tie provided by OEM) for cable management. Model should be Cenificatcs of CompJiance: UL, CE/FCC, BIS. The CCTV OEM should have CMMI Level S or aboie or equivalent setup certification. The CCTV OEM should have its office and service/ support center in RajasthanAll as per pre approved by £ngineer in charge for additional techriical parameters of products/ work , refer Annexuic "A' aitached with this BSR
Supply, Installation. Testing & Commissioning of 32 ch NVR Pre-licenced, NVR supports upto 40 TB HDD Support, 32 ch IP inputs; ; Support ANR technology 320mbps incoming bandwidth, supports up to 12MP full channel recording; suppon H.265 compression; l6ch syncronised playback @l080p; support 3rd party camems ONVIF type, 4K output: minimum 04 SATA HDD Slots; each slot should suppport upto l OTB HDD; Dual gigabit self adaptive Ethernet interface; seriai interface; USB interface; (all camcras and Storage-NVR shouîd be of same mie for the smœth functioning of the system).complete with mounting accessories & jwiction box (to be provided by OEMs for cable management. Model should be Certificates of Compliance: UL, CE/FCC, BIS. The CCTV OEM should have CMMt Level 5 or above or equivalent scnip certification. The CCTV OEM should have its office and service/ support center in RajasthanAll as per pre approved by Engineer in charge. I-or additional technical parameters of products/ work , refer Annexure ”A" attached with this DSR
Supply. Installation, Testing & Commissioning of of 3.5" 6 TB SATA ,USB 3.0 Surveillance Hard Disk .All as per pre approved by Engineer in charge. For addiüonal technical pararneters of produets/ york , rater Arinexun ”A" aliached With this BSR
Supply, Installation, testing and coinmissioning of BIS compliancc Professional series Diagonal Screcn sÎze 43" LED with Résolution 3.840 x 2,160 (4K UHD) along with Static (Panel) Conoast Ratio (1300:1) or better with viewùig angle o 178/178 degree with response time of 8ms along with fmMl fn 2.0 - 2 nos., USB 2.0 2 nos., RS 232- 1 nos., Rf 45- I Nos. with Built in Speairer(10W + l0W, ) with high speed processor and andrnid or other reputated operationg system along with 4 GB RAM along with all audio and video decoder, Stand-by / sleep / off mode power 0.5 wa+t, All as per pro approved by Engineer in charge. For additional technicai parameters of products/ worf , inter Annexwe •A” attached with this BSR
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with HDPE, U/UTP (Unscreened/Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Outdoor Cable as per latest ammendments of ANSI/TIA/EIA-568 C.2 & ISO/IEC 11801 2nd Ed, The copper conductors should be balanced twisted in pairs, seperated by a cross divider & protected by LSZH PVC outer jacket of UV resistant. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. Should meet IEEE 802.3af & IEEE 802.3at for POE applications. Cable Should support Ethernet 10GBASE-T according to the standards. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
SITC of 4port Giga PoE Switch with dualup link: unmanaged PoEswitch;4X10/100/1000mbpsBase-TPoE;2*10/100/1000 Base-T (Uplink) or 2*1000 Base-X (uplink); PoE Power ConsumptionperPort: ≤30W; powerbudget:minimum96W; PoE Protocols: IEEE802.3af, IEEE802.3at ; Switching Capacity: 20Gbps or better;MACTableSize2Kor better; WorkingTemperature:-5°C~55°C; Power supply: DC48~57V Certificateofcompliance: CE/FCC.Allasperpreapprovedby Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attachedwithP.W.D. Electrical B.S.R. 2022.
SITCof8port GigaPoESwitchwithdualuplink: unmanaged PoEswitch;8X10/100/1000mbpsBase-TPoE;2*10/100/1000 Base-T (Uplink) or 2*1000 Base-X (uplink); PoE Power ConsumptionperPort: ≤30W; powerbudget:minimum96W; PoE Protocols: IEEE802.3af, IEEE802.3at ; Switching Capacity: 20Gbps or better;MACTableSize2Kor better; WorkingTemperature:-5°C~55°C; Power supply: DC48~57V Certificateofcompliance: CE/FCC.Allasperpreapprovedby Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attachedwithP.W.D. Electrical B.S.R. 2022.
Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent Giga Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) all switches & related Fiber modules should be of same make & category for seamless integration with each other of Enterprise class Catalyst Series including making connections etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Supply, Installation, & Testing of 19" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, multimode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirement complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supply , Installation, Testing and Comissioning of Hot pluggable Small Form Factor Pluggable (SFP Module), 1000BASE-SX, 1.25/2.125G Fiber Channel, LC Type Duplex Connector, 850nm laser transmitter, Should support distance upto 500m on 50/125um of data rate upto 2.125 Gb/s on bi-directional data links. Should also support industrial temperature, should have metal enclosure for lower EMI. The transceiver should be ROHS Compliant. (For Each MM Fiber) all switches & related Fiber modules should be of same make & category for seamless integration with each other of Enterprise class, complete in all respect.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 µm (OS1/OS2) made of glass fiber optic with LSZH jacket, F8 2.0x4.1 mm, yellow, singlemode G652.D (9/125 µm (OS1, OS2) Mounted on both sides with ST/E-2000/SC/LC/MT-RJ/PC type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL < 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords's performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Singlemode Pigtail (9/125 µm (OS1/OS2) made of glass fiber optic, with semi-tight buffer PA/PBT, Ø 0.9 mm, yellow, singlemode G652.D (9/125 µm (OS1, OS2), should have length of min 1.5m, should be fitted at one end with any one type of single ST/E2000/SC/LC/MT-RJ/PC type connector in acc. with IEC 61754-20, Should be delta IL < 0.2 dB after 500 mating cycles, It should be Zirconia (ceramic) ferrule with a PC polished endface geometry connector qualified in acc. with IEC 61753-1 for category U (uncontrolled environment). and qualified in acc. with IEC 61753-1, Performance acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, Standard Specification as per requirments.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below: outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supply, Drawing and Testing, of stranded Single mode (9/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR 6 fiber
Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
Add Extra in item no. 60.1 to 60.4 for Laying Charges for cable through Vermeer machine by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required
Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supply, Installation, Testing & Commissioning of 2 KVA 1 Phase lnput,wit1i GB7 Based Rectifier True Online Double Conmnion Robusi design Wide input voltage range: 16fi300 VAC @ I00% 1o8d(II 7 debating to 50•2• load @ IOOVAC input) Generator Compatible with Wide Input voltage window Double Conversion Efficiency *91% & ECO mode efficiency up to 98% 100% load @ H40C operating temp. Active Input Power Factor Correction 0.99 O/P power faetnr 0.9 inbuilt OVCD (Over Voltage Cut-off device) Fully conform coated PCBA adaptable to harsh environment Offer terminal blocker on 2K/3K rating to connect to big capacity equipment Digital Charger Technology provide 02- IO A charging current Easy understanding LCD for convenient installation setup with Minimum 60 minute battery back up (26A H x 6 Nos of SMF batteries branded and recommended by UPS O£M, battery stand and inter1uil‹ FR PVC copper cable of appropriate size and lugs), with tequiteñ cabling for incoming & outgoing connection. UPS should be NABL certified with CE, ROHS & BIS compliance. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , reter Annexure ’A” attached with this BSR /{
DECORATIVE POLE WORK
Supply & Installation of decorative ornamental stepped pole total height 4000 mm bottom made out of 140 mm dia MS pipes 1000 mm and Middle pipe was 76 mm dia, OD MS pipe 3000 mm height. Top 60 mm for fixing the light the pole shall have window opening with flush door with looking arrangement at bottom of the pole to accommodate electrical accessories. The decorative pole shall be duty pretreated & painted in UV ray resistant PU coating in approved colour. The pole shall be erected on CC foundation 450mmx 450 mm size 1 sou bolt 20mmx750 x1000mm with foundation leneth. 4 Meter Decorative Pole with Single Arm
Supply of IP 65 Protected Decorative LED Post Top suspended lantern range made up of spun aluminum canopy with die cast aluminum spigot. Fitted with glare free optically designed prismatic diffuser protected LED decorative Post Top lantern with Low glare optical design & Acrylic diffuser 45W. 220-240V, 50Hz (Integrated driver) driver shall be high efficiency having efficiency 85% and in compliance to IEC stans 2rd (Integral with ligit fixture) system life of 25000 burning hours 70% of initial lumens maintained. system 0.95 and CRI 70 efficency should greather than or equal 75Lm/W Power Factory Decorative. LED Post Top 45 Warm White
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
A) Excavation of Pit for Foundation Size upto required depth from Ground level
B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.
C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness
D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.
E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal
F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.
G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.
H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.
Pole Foundation for Octagonal pole from 3 Mtr. To 6 Mtr.
Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
One day reserve (Analog type )
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-
(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided
(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.
[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )
(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.
(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.
(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )
(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.
(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
4 pole Power contactors with following AC 1 Rating
Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Single pole MCB (With B/C curve tripping Characteristics)
6 A to 32 A rating
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
4 pole MCCB With Thermal Magnetic release
125 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
3x 1.5 sq.mm
Fontain work
P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
2.5 Sq.mm 3 core flat / Round
Supply and laying PVC Insulated and PVC Round Sheathed Multi Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade. Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
1.5 sq.mm x 4 core
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accredited Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Armoured Cable
120sqmm 3.5 core
Supply and fixing of fasting acting high pressure and high Flow Aqua group ASM series Horizontal Submersible pump 3 phase of 10 Hp for fountain use only (approx discharge 1950 LPM on 12mtr head) With SS 304 nut bolts, rubber washers. Make Oase, Grounforce, KSB, Aqua group, Texmo
Supply and fixing fasting acting high pressure and high Flow Aqua group ASM series Horizontal Submersible pump 3 phase of 2 Hp for fountain use only (approx discharge 750 LPM on 6mtr head) With SS 304 nut bolts, rubber washers. Make Oase, Grounforce, KSB, Aqua group, Texmo
SITC of Electrical Panels (BCH make) double door type made of 1.2 CRCA sheet with mounting plate made of 2 mm galvanised sheet of size 1000 x 1200 x 300 mm JF-NP2 series with Star delta starter for 10Hp and DOL for 2Hp pumps (BCH, Siemens), MCB's (Legrand, Siemens), ammeter, voltmeter, single phasing preventer, indicating lights, Bus Bar, etc.-Suitable for 1 nos of 10HP and 6 nos 2Hp submersible pumps Weather proof body fixed with MS angle frame stand in suitable size CC min 450mm deep in ground. Make OASE, Wet Design, Fountana fountains, Waltzing Waters, Jet fountains, ALT
SITC of Hollow jet nozzle of made of Brass / SS 304 Material with required other components made of Brass/ SS304 / Aluminium having arrangement to fix on 75mm / 100mm Pump Outlet and min 25mm outlet. Make OASE, Wet Design, Fountana fountains, Waltzing Waters, Jet fountains, ALT
Providing and Fixing of 1 nos of 1.25 m wide with thickness 8" thick in center and 4" from sides hexagonal floating unit made of Fibber reinforced Plastic with insulation filled. Provision for installation of submersible pump with fountain lights and Pump structure. the floating plate form should be fixed with 2 nos of anchors with Wire / PP rope for connecting the floating platform with the anchors. Make OASE, Wet Design, Fountana fountains, Waltzing Waters, Jet fountains, ALT
S&F of 3" water coulomb / 2" aerating jet (max. height 5M) made of SS 304 , brass, Aluminium material Make OASE, Wet Design, Fountana fountains, Waltzing Waters, Jet fountains, ALT
SITC of IP 68 protected LED Under water light 130mm min dia & 85mm min height made of SS 304 sheet housing having 9W LED lamps, work on 12 / 24 V DC supply with semi conductor controlling chip who control voltage and can support DMX protocol. Having dynamic colour changing Ability to create 16.7 million uniform, smooth and brilliant colours available in quick connecting cable coupled with various counting accessories, Available in 4 type single colour - Red, green, blue, warm white Or RGB multi Colour changing. Make OASE, Wet Design, Fountana fountains, Waltzing Waters, Jet fountains, ALT
SITC of Colour changing controller for LED lights, work on 12-24v DC with 150w working load capacity with semi conductor controlling chip who control voltage and support DMX / RS485 / I2C protocol to synch other colour changing controller connected in series for same colour output. Make OASE, Wet Design, Fountana fountains, Waltzing Waters, Jet fountains, ALT
SITC of 12v DC, 150 watt industrial grade SPMS Power supply. Make Phoenix Lubi, Delta, Meam well, hyundai, Union.
Supply and fixing of SS 304 grade structure with 2'' or 2.5'' dia with 3mm min. wall thickness pipe industrial grade pipe for fountain with stands for lights, valves and accessories to fix nozzles with pump Make OASE, Wet Design, Fountana fountains, Waltzing Waters, Jet fountains, ALT
Supply and fixing of filter made SS 304 frame of size 7" x 7" x 10" with SS 304 plate at both side having 1" to 3" threaded nizzle (as per pump inlet) and rest 4 sides surroundingly rapet by SS 304 mesh suitable for 0.5 Hp pump to 5 Hp pump. Make OASE, Wet Design, Fountana fountains, Waltzing Waters, Jet fountains, ALT
Supply and fixing of filter made SS 304 frame of size 10" x 10" x 17" with SS 304 plate at both side having 2" to 5" threaded nizzle (as per pump inlet) and rest 4 sides surroundingly rapet by SS 304 mesh suitable for 5Hp pump to 15Hp pump. Make OASE, Wet Design, Fountana fountains, Waltzing Waters, Jet fountains, ALT
HT LT LINE WORK
S I T C of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 . including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect .
The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
Extensible 3 way RMU with 1 no. VCB & 2 No. Load Break Switch
Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
3 core 185.0 Sq.mm
Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. (Earth Excavation will be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annex ure "A" attached with this BSR .
80 mm dia.
50 mm dia.
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
11 KV End Termination Kit Indoor type
3 core 120/150/185 Sq.mm
11 KV End Termination Kit Outdoor type
3 core 120/150/185 Sq.mm
Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supply and fixing of LT Distribution Kiosk confirming to IS:13947/1993/ IEC 60947 Pt.3 amended up-to-date and as per DISCOM specifications made of 2 mm thick powder coated CRCA sheet of 415 volts 3 phase 4 wire triple pole and neutral type, complete in all respect as required. Including Incoming Switch Disconnector Fuse unit, Aluminium Busbar with copper one piece U contacts base, brass studs and nuts, copper busbar for main and interconnection, MS Channel frame of 75 mm x 40 mm grouted with C.C. of M-10 grade to achieve the height of 1.5 feet above the road level suitable for required no. outgoing. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
200 Amp. LT Distribution Kiosk for 63/100 KVA Transformer
Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM.
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
3.pdf
Tender Documents • 10.57 MB
BOQ_947662.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid