| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC MAYURESH BHARAT CHS PLOT NO 170 181 B 09 SECTOR 21 NERUL NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹34.0 L+₹31,539 (0.94%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹34.2 L+₹55,499 (1.65%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹34.7 L+₹97,298 (2.89%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹37.8 L+₹4.1 L (12.2%)Rejected-Finance | L5 | Rejected-Finance Being 5th lowest |
| Sl No | Description | Qty | Unit | DARSHAN CONSTRUCTION Co. L3 | ECOBUILD L1 | Nexus Infratech L2 | M.K Enterprises L4 | R A Electric Co. L5 | SREE HARITHA ASSOCIATES L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Sch" A" Part- I (Periodical Maintenance)
Material and labour for periodical maintenance of fire alarm system by attending fault, testing of system, periodical checking of system, including testing on monthly basis in presence of user representative etc including attending system fault on emergency , preventive measures by replacing minor spares(up to cost Rs 1000/- including GST and other charges) other than mentioned in Schedule 'A' Part II for fire alarm system installed at Magic Matra building comprising following all as specified and directed by Engr-in-Charge :-
(a) 08 Zone main control panel with zone card battery charger and 230 V power unit.
(b) Ionisation type smoke detector, heat detector, response indicator, manual call point and hooters etc.
(c) All cable connections from main control panel to items
(d) Lead acid battery any capacity
(e) Electric Hooter | 11 | Per month | 4,000 ₹44,000 | 3,700 ₹40,700 Lowest | 4,000 ₹44,000 | 3,999 ₹43,989 | 3,857 ₹42,427 | 4,100 ₹45,100 |
| 2.00 | Ditto- all as per serial item No 1.00 here-in-before but for compressor room bldg in EKM complex (Bldg No 784) for 8 Zone main control panel | 11 | Per month | 4,000 ₹44,000 | 3,700 ₹40,700 Lowest | 4,050 ₹44,550 | 3,999 ₹43,989 | 3,878 ₹42,658 | 4,100 ₹45,100 |
| 3.00 | Ditto- all as per serial item No 1.00 here-in-before but for oxygen workshop bldg in EKM complex (Bldg No 783) for 8 Zone main control panel | 11 | Per month | 4,000 ₹44,000 | 3,700 ₹40,700 Lowest | 4,100 ₹45,100 | 3,999 ₹43,989 | 3,879 ₹42,669 | 4,100 ₹45,100 |
| 4.00 | Ditto- all as per serial item No 1.00 here-in-before but for Armoury store room at INS Abhimanyu complex for 8 Zone main control panel | 11 | Per month | 4,000 ₹44,000 | 3,700 ₹40,700 Lowest | 4,100 ₹45,100 | 3,999 ₹43,989 | 3,889 ₹42,779 | 4,100 ₹45,100 |
| 5.00 | Ditto- all as per serial item No 1.00 here-in-before but for Sea Cat workshop bldg in NAD (Karanja) with 8 zone main control panel | 11 | Per month | 4,000 ₹44,000 | 3,700 ₹40,700 Lowest | 4,100 ₹45,100 | 3,999 ₹43,989 | 3,929 ₹43,219 | 4,100 ₹45,100 |
| 6.00 | Ditto- all as per serial item No 1.00 here-in-before but for Maurya Hanger for 15 Zone main control panel | 11 | Per month | 4,000 ₹44,000 | 3,700 ₹40,700 Lowest | 4,100 ₹45,100 | 3,999 ₹43,989 | 3,969 ₹43,659 | 4,100 ₹45,100 |
| 7.00 | Ditto- all as per serial item No 1.00 here-in-before but for Harshawardhan Hanger (MRF P-20) for 15 Zone main control panel | 11 | Per month | 4,000 ₹44,000 | 3,700 ₹40,700 Lowest | 4,100 ₹45,100 | 3,999 ₹43,989 | 3,959 ₹43,549 | 4,100 ₹45,100 |
| 8.00 | Ditto- all as per serial item No 1.00 here-in-before but for Kashmir TP for 8 Zone main control panel | 11 | Per month | 4,000 ₹44,000 | 3,700 ₹40,700 Lowest | 4,250 ₹46,750 | 3,999 ₹43,989 | 3,919 ₹43,109 | 4,100 ₹45,100 |
| 9.00 | Ditto- all as per serial item No 1.00 here-in-before but for Club TP for 2 loop Addressable type fire alarm control panel | 11 | Per month | 4,000 ₹44,000 | 3,700 ₹40,700 Lowest | 4,100 ₹45,100 | 3,999 ₹43,989 | 3,883 ₹42,713 | 4,100 ₹45,100 |
| 10.00 | Ditto- all as per serial item No 1.00 here-in-before but for NAD Explosive area Fire Station for 12 Zone main control panel | 11 | Per month | 4,000 ₹44,000 | 3,700 ₹40,700 Lowest | 4,100 ₹45,100 | 3,999 ₹43,989 | 3,838 ₹42,218 | 4,100 ₹45,100 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
14 Mar 2025, 6:00 pmClosed
CWE Karanja
CWE Karanja, Naval Station Karanja, Uran, Raigad - 400704
PERIODICAL MAINTENANCE AND ESSENTIAL REPAIRS TO FIRE ALARM SYSTEM AT NAVAL STATION KARANJA
2025_MES_698929_1
84381-K/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Naval Station Karanja
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (NW) Karanja
₹70,000
7 Aug 2025
21 Feb 2025
17 Mar 2025
21 Feb 2025
14 Mar 2025
7 Mar 2025
Amount
Sch" A" Part- I (Periodical Maintenance) Material and labour for periodical maintenance of fire alarm system by attending fault, testing of system, periodical checking of system, including testing on monthly basis in presence of user representative etc including attending system fault on emergency , preventive measures by replacing minor spares(up to cost Rs 1000/- including GST and other charges) other than mentioned in Schedule 'A' Part II for fire alarm system installed at Magic Matra building comprising following all as specified and directed by Engr-in-Charge :- (a) 08 Zone main control panel with zone card battery charger and 230 V power unit. (b) Ionisation type smoke detector, heat detector, response indicator, manual call point and hooters etc. (c) All cable connections from main control panel to items (d) Lead acid battery any capacity (e) Electric Hooter
Ditto- all as per serial item No 1.00 here-in-before but for compressor room bldg in EKM complex (Bldg No 784) for 8 Zone main control panel
Ditto- all as per serial item No 1.00 here-in-before but for oxygen workshop bldg in EKM complex (Bldg No 783) for 8 Zone main control panel
Ditto- all as per serial item No 1.00 here-in-before but for Armoury store room at INS Abhimanyu complex for 8 Zone main control panel
Ditto- all as per serial item No 1.00 here-in-before but for Sea Cat workshop bldg in NAD (Karanja) with 8 zone main control panel
Ditto- all as per serial item No 1.00 here-in-before but for Maurya Hanger for 15 Zone main control panel
Ditto- all as per serial item No 1.00 here-in-before but for Harshawardhan Hanger (MRF P-20) for 15 Zone main control panel
Ditto- all as per serial item No 1.00 here-in-before but for Kashmir TP for 8 Zone main control panel
Ditto- all as per serial item No 1.00 here-in-before but for Club TP for 2 loop Addressable type fire alarm control panel
Ditto- all as per serial item No 1.00 here-in-before but for NAD Explosive area Fire Station for 12 Zone main control panel
Ditto- all as per serial item No 1.00 here-in-before but for NAD Main Fire Headquarter Non- Explosive area for 12 Zone main control panel and 20 Zone Control Panel
Ditto- all as per serial item No 1.00 here-in-before but for Bldg No P- 249/1 ( 'G' Fueling Points Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier, addressable Detector, Manual call Point, Hooter.
Ditto- all as per serial item No 1.00 here-in-before but for Bldg No P- 747 ( 'New 'O' Fueling Points Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier, addressable Detector, Manual call Point, Hooter.
Ditto- all as per serial item No 1.00 here-in-before but for Bldg No P-364 ( 'G' Damp No - 4 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier, addressable Detector, Manual call Point, Hooter.
Ditto- all as per serial item No 1.00 here-in-before but for Bldg No P- 363 ('G' Damp No - 3 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier, addressable Detector, Manual call Point, Hooter.
Ditto- all as per serial item No 1.00 here-in-before but for Bldg No P- 365A ('O' Damp No - 2 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier, addressable Detector, Manual call Point, Hooter.
Ditto- all as per serial item No 1.00 here-in-before but for Bldg No P- 208 ( 'O' Damp No - 1 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier, addressable Detector, Manual call Point, Hooter.
Ditto- all as per serial item No 1.00 here-in-before but for Bldg No P- 741 ( 'G' Damp No - 2 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier, addressable Detector, Manual call Point, Hooter.
Ditto- all as per serial item No 1.00 here-in-before but for Bldg No P- 248 (Old 'O' Fueling Point 2 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier, addressable Detector, Manual call Point, Hooter.
Ditto- all as per serial item No 1.00 here-in-before but for Bldg No P- 746 (Club Fueling Point Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier, addressable Detector, Manual call Point, Hooter.
Ditto- all as per serial item No 1.00 here-in-before but for Type -III Accn , NAD Colony for 07 loop main control panel with electric siren of 02 Km range and amplifier and microphone.
Ditto- all as per serial item No 1.00 here-in-before but for 582 Bldg for 07 Zone main control panel with electric siren of 02 Km range and amplifier and microphone.
Ditto- all as per serial item No 1.00 here-in-before but for Type -II (A Block) Accn , Chunabhatti Area for 07 loop main control panel with electric siren of 02 Km range and amplifier and microphone.
Ditto- all as per serial item No 1.00 here-in-before but for NAD Main Gate Non- Explosive area but for 12 Zone main control panel and 20 Zone Control Panel
Ditto- all as per serial item No 1.00 here-in-before but for Type -II (B Block) Accn , Chunabhatti Area but for 07 loop main control panel with electric siren of 02 Km range and amplifier and microphone.
Ditto- all as per serial item No 1.00 here-in-before but for Kakoli Bldg for 12 Zone main control panel.
Ditto- all as per serial item No 1.00 here-in-before but for Kalapi Bldg for 24 Zone main control panel.
Ditto- all as per serial item No 1.00 here-in-before but for Kiran Bldg for 24 Zone main control panel.
Ditto- all as per serial item No 1.00 here-in-before but for Komal Bldg for 24 Zone main control panel.
Ditto- all as per serial item No 1.00 here-in-before but for Kailash Bldg for 24 Zone main control panel.
Ditto- all as per serial item No 1.00 here-in-before but for Kesar Bldg for 12 Zone main control panel.
Ditto- all as per serial item No 1.00 here-in-before but for Koyal building for 8 Zone main control panel.
Ditto- all as per serial item No 1.00 here-in-before but for Kalpana building for 8 Zone main control panel.
Ditto- all as per serial item No 1.00 here-in-before but for Kaneri building for 8 Zone main control panel.
Ditto- all as per serial item No 1.00 here-in-before but for Abhimanyu clothing Store building for 4 Zone main control panel.
Ditto- all as per serial item No 1.00 here-in-before but for Derby hanger for Single loop addressable panel.
Ditto- all as per serial item No 1.00 here-in-before but for Sub fire HQ at NAD for 12 Zone conventional panel.
Ditto- all as per serial item No 1.00 here-in-before but for Type III NAD for Single loop addressable panel.
Ditto- all as per serial item No 1.00 here-in-before but for Harpoon process bldg Tunir for Single loop addressable panel.
Ditto- all as per serial item No 1.00 here-in-before but for Chukar Sqdn III for Single loop addressable panel.
Ditto- all as per serial item No 1.00 here-in-before but for COMCEN (SOK) for Single loop addressable panel.
Ditto- all as per serial item No 1.00 here-in-before but for Chariot Hanger for Single loop addressable panel.
Ditto- all as per serial item No 1.00 here-in-before but for NAD Factory -II Bldg for Single loop addressable panel.
Ditto- all as per serial item No 1.00 here-in-before but for Narmada Bldg for Single loop addressable panel.
Ditto- all as per serial item No 1.00 here-in-before but for 140 DSC pers Md Accn (Sangam, Zhelam and Yamuna) Bldg for Single loop addressable panel.
Notes for Serial item Nos 1.00 to 45.00 :- (i) Cost of Minor spare parts replaced other than listed in Sch "A" Part II shall be deemed to be included in the rate quoted by the contractor. (ii) Testing kit (Solo Smoke and heat detector kit) will be provided by the MES for testing and will be submitted to the department after the testing.
Sch ''A'' Part-II (ESSENTIAL REPAIRS) Excavation in trenches not exc 1.5 meter wide and not exc 1.5 meter depth and getting out in soft/loose soil including taking out faulty cable/cable, cable covers and GI pipe complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing excavated soil not exc 50 metres and depositing where directed at a level notexc 1.5 metres above the starting point, complete all as specified and directed by Engr-in-Charge.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming complete all as specified and directed by Engr-in-Charge.
Supply & laying un-reinforced precast concrete cable cover with embossing of cable size and capacity class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement manual call point conventional type surface mounting type of standard size with alarm raising push button, plastic coated glass element suitable for conventional type fire alarm system etc complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement smoke detector confirming to E- 54.7 standard of size 100mm dia, height 56mm suitable to work on 24V DC (12 V DC - 28 V DC) fixed with LED made out of flame retardant plastic confirming to fire protection standard complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement heat detector automatic reset type (class air series 65) complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement 1.5 sqmm 02 core armoured copper conductor cable ISI marked complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement 1.5 sqmm 04 core armoured copper conductor cable ISI marked complete all as specified and directed by Engr-in-Charge.
Supply only lead acid battery 12V/7AH capacity (maintenance free) complete all as specified and directed by Engr-in-Charge.
Supply & fix in repair fire alarm hooter with speaker suitable for PA system complete all as specified and directed by Engr-in-Charge.
Supply and Fix fire alarm sounders/sirens electronic type horizontal single stage continuous normal operation for atleast 50 minutes with sound level 65 dB to 120 dB measured at 1.5 meter with sound output variation of +5 dB of 3500 m range complete all as specified and directed by Engr-in-Charge.
Supply and fix in Repairs Zone Card Suitable for Conventional Type fire alarm system working with 24 DC Volt supply complete all as specified and directed by Engr-in-Charge.
Supply and fix in Repairs Power Supply Card Suitable for Conventional Type fire alarm system working with 24 DC Volt supply complete all as specified and directed by Engr-in-Charge.
Supply and fix in Repairs Control Monitor Card Suitable for Conventional Type fire alarm system working with 24 DC Volt supply complete all as specified and directed by Engr-in-Charge.
Supply and fix in Repairs Transformer unit Suitable for Conventional Type fire alarm system working with 24 DC Volt supply complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of complete mother board suitable for conventional type fire alarm panel board confirming to fire protection standard all as specified and directed by Engr -in- Charge.
Supply & fix in replacement multisensor with heat and smoke combination suitable for Addressable type fire alarm panel board working on 24V DC (12 V DC - 28 V DC), made out of flame retardant plastic confirming to fire protection standard complete all as specified and directed by Engr-in-Charge. .
Supply & fix in replacement Manual Call Point suitable for Addressable type fire alarm panel board confirming to fire protection standard complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement Power Supply SMPS suitable for Addressable type fire alarm panel board confirming to fire protection standard complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement Single Loop Card suitable for Addressable type fire alarm panel board confirming to fire protection standard complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of complete mother board suitable for Addressable type fire alarm panel board confirming to fire protection standard complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable conventional type fire alarm control panel from existing position and supply, testing and install new microprocessor type fire alarm control panel of 8 zone to work on single phase AC supply 50 Hz fabricated out of CRCA sheet with standard size as per OEM recommendation duly painted including wiring with suitable copper conductor cable Form panel to floor level manual call point and upto smoke/ heat detector if required all as specified and directed by Engineer-in-Charge.
Taking down unserviceable conventional type fire alarm control panel from existing position and supply, testing and install new microprocessor type fire alarm control panel of 12 zone to work on single phase AC supply 50 Hz fabricated out of CRCA sheet with standard size as per OEM recommendation duly painted including wiring with suitable copper conductor cable Form panel to floor level manual call point and upto smoke/ heat detector if required all as specified and directed by Engineer-in-Charge.
Taking down unserviceable Addressable type fire alarm control panel from existing position and supply, testing and install new Addressable type fire alarm control panel complying with BS EN 54, single loop, Panel of Capacity from 99 detector & 99 modules up to 200 to work on single phase 50 Hz fabricated out of CRCA sheet steel as per OEM Recommendation including connecting with suitable copper conductor cable Form panel to floor/ Roof level manual call point and upto smoke/ heat detector all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of control module for Addressable type fire alarm panel confirming to fire protection standard all as specified and directed by Engr -in- Charge.
Supply and fix in replacement of monitor module for Addressable type fire alarm panel confirming to fire protection standard all as specified and directed by Engr -in- Charge.
Nexus Infratech (BID ID -3262585)
DARSHAN CONSTRUCTION Co. (BID ID -3262195)
M.K Enterprises (BID ID -3262856)
R A Electric Co. (BID ID -3263107)
SREE HARITHA ASSOCIATES (BID ID -3263182)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .