Supply and Installation of two nos. 1.5 Ton Split Air Conditioners at the Chamber of the Honble MoS, Hemanta Bhavan 1st Floor, 12, B.B.D. Bag. (2nd Call)
2026_MSMET_1039291_2
NIET 14 (Elec.) of 2026-27
Open Tender
Electrical Work/ Equipment
Item Rate
15 days
Kolkata
Please refer Tender documents.
6 documents required · 6 mandatory
₹236
₹2,377
24 Aug 2026
24 Aug 2026
7 Sept 2026
25 Aug 2026
3 Sept 2026
25 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC.
Cooling Capacity- 5.2 kW (Minimum) , Air Flow Rate:600 CFM (Minimum)
Minimum ISEER - 5.0, BEE level - 4-Star(min) (1.5 ton) (Make: Carrier or as appd by EIC) | 2 | Each | 48,215.46 | ₹96,430.92 |
| 2Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | |||||
| 2.1 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 11 | Mtr. | 265.77 | ₹2,923.47 |
| 2.2 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 11 | Mtr. | 604.24 | ₹6,646.64 |
| 3 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. | 2 | Each | 153.74 | ₹307.48 |
| 4 | Supply & fixing MS powder coated stand suitable for 1.5 ton outdoor type of Cassette AC. All as per pre-approved by EIC. | 20 | Kg | 104.88 | ₹2,097.6 |
| 5 | Deployment of Air-conditioning Mistry for dismantling of existing A.C machine. | 2 | Each | 643.69 | ₹1,287.38 |
| 6 | Deployment of Helper for Air-conditioning Mistry for dismantling of existing A.C machine. | 3 | Each | 586.01 | ₹1,758.03 |
| 7 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. | 15 | Mtr. | 73.89 | ₹1,108.35 |
| 8 | Supply & Fixing 1.1 KV grade 3 core 2.5 sq.mm power cable of PVC insulated, Round Flexible Copper conductor between cooling unit & condensing unit. (Make: Polycab/ KEI/ Havells or equ as approved by EIC) | 20 | Mtr. | 314.64 | ₹6,292.8 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.01 MB
Tendernotice_2.pdf
PDF • 0.10 MB
Tendernotice_3.pdf
PDF • 5.95 MB
Tendernotice_4.pdf
PDF • 0.19 MB
Tendernotice_5.pdf
PDF • 1.05 MB
BOQ_2552452.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].