| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹29.8 L+₹1.0 L (3.60%)Rejected-Finance | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹30.0 L+₹1.3 L (4.37%)Rejected-Finance | L3 | Rejected-Finance Being higher bidder | |
| 4 | L4₹31.2 L+₹2.4 L (8.46%)Rejected-Finance 29 7 KACHERI ROAD NEAR DISTRICT HOSPITAL PRATAPGARH PRATAPGARH UTTAR PRADESH 230001 | PRATAPGARH | UTTAR PRADESH | 230001 | L4 | Rejected-Finance Being higher bidder | |
| 5 | L5₹31.5 L+₹2.8 L (9.60%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance Being higher bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
15 Oct 2022, 6:00 pmClosed
GE AF Tech Area Agra
GE AF Tech Area Agra
REPAIR MAINT OF LT PANEL, FEEDER PILLAR BOXES JUNCTION BOXES TO BUILDING, LT DISTRIBUTION SYSTEM AND CONNECTED ITEM IN ZONE A TECH AREA INCL MAFI UNDER GE AF TECH AREA AGRA AT AF AGRA
2022_MES_552704_1
8200-1455/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Tech Area Agra
As per NIT
9 documents required · 9 mandatory
₹500
GE AF Tech Area Agra
₹80,000
Yes
14 Jan 2023
17 Sept 2022
17 Oct 2022
17 Sept 2022
15 Oct 2022
1 Oct 2022
17 Sept 2022 - 24 Sept 2022
Amount
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line and getting out complete all as specified and as directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed.
Removal of surplus excavated soil to a distance n. exc 50 m above the starting point complete all as specified and as directed.
Supply & laying of best locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and as directed.
Re-laying of old serviceable bricks as in cable protection cover, laid flat and dry in trenches over the cable length brick laid prependicular to the direction of cable complete all as specified and as directed. Note:- Old serviceable bricks obtained during excavation shall be used under this item.
M&L for sand coushioning with clean dry fine sand unwashed including gently punning around cable in trenches for cable protection complete and filling the sand in cable duct inside the sub station building complete all as specified and as directed. Note:- Punned thickness of sand shall be measured and paid for sand used in cushioning to cable.
Taking out of old XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 10 sqmm to 70 Sqmm 3.5/4 core from trenches or fixed on wall/floor/poles etc complete all as specified and as directed.
Taking out of old XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 95 sqmm to 400 Sqmm 3.5/4 core from trenches or fixed on wall/floor/poles etc complete all as specified and as directed.
Laying only old serviceable XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of following sizes laid in trenches or fixed on walls/floor/pole etc complete all as specified and as directed.
(a) 10 sqmm to 70 Sqmm 3.5/4 core
(b) 95 sqmm to 400 Sqmm 3.5/4 core
Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of the following sizes laid in trenches or fixed on wall/floor/poles complete all as specified and as directed :-
(a)10 Sq mm 4 core
(b)16 Sq mm 4 core
(c) 25 Sq mm 4 core
(d) 35 Sq mm 3.5 core
(e) 50 Sq mm 3.5 core
(f) 70 Sq mm 3.5 core
(g) 95 Sq mm 3.5 core
(h) 120 Sq mm 3.5 core
(i) 240 Sq mm 3.5 core
M&L for jointing kit suitable for LT 1100 volts cable (earthed) for out door straight through joint, heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-
(a) 25 to 50 Sqmm 3.5/4 core
(b) 70 to 120 Sqmm 3.5 core
(c) 150 to 240 Sqmm 3.5 core
M&L for End jointing kit suitable for LT 1100 volts cable (earthed) for out door , heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-
(a) 10 to 50 Sqmm 3.5 core
(b) 70 to 120 Sqmm 3.5 core
(c) 150 to 240 Sqmm 3.5 core
Supply, Fix & install MCCB with factory made sheet metal enclosure with provision of cable connection for incoming and outgoing complete all as specified and directed as mentioned below:- a) MCCB 160 Amps, 25KA , 4 pole with thermal magnetic release -01 No b) MCCB sheet steel enclosure 'A' Frame four pole - 01 No
Supply, Fix & install MCCB with factory made sheet metal enclosure with provision of cable connection for incoming and outgoing complete all as specified and directed as mentioned below:- a) MCCB 250 Amps, 25KA , 4 pole with thermal magnetic release -01 No b) MCCB sheet steel enclosure 'A' Frame four pole - 01 No
M&L for drilling suitable dia horizontal bore holes for insertion / laying of 50/100 mm bore GI tubing of any description below/under road surface/floors etc with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing surfaces after laying pipes complete all as specified and as directed.
Supply and fixing in repair GI tubing 'light grade' of 100 mm bore for cable protection fixed on pole/wall/floor/or laid in trenches and drain etc complete with necessary MS clamp, nut, bolts and washers and socket complete all as specified and directed.
Supply and fixing of GI tubing 'light grade' of 50 mm bore for cable protection fixed on pole/wall/floor/or laid in trenches and drain etc complete with necessary MS clamp, nut, bolts and washers and socket complete all as specified and directed.
Supply and fixing of GI tubing 'light grade' of 40 mm bore for cable protection fixed on pole/wall/floor/or laid in trenches and drain etc complete with necessary MS clamp, nut, bolts and washers and socket complete all as specified and directed.
Demolition of PCC/Black bitumin road of any description and in any position not otherwise specially provided , etc complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20 mm gradded stone aggregate for coping of poles, panel board including necessary form work etc complete all as specified and as directed.
M&L for rendering 10 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed.
Supply and fixing MCCB of the following sizes on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and as directed
(a) MCCB 4 pole , 630 amp rating of 36 KA,
(b) MCCB 4 pole , 400 amp rating of 36 KA
(c) MCCB 4 pole , 250 amp rating of 25 KA
(d) MCCB 4 pole , 200 amp rating of 25 KA
(e) MCCB 4 pole , 160 amp rating of 16 KA
(f) MCCB 4 pole , 125 amp rating of 16 KA
(g) MCCB 4 pole , 100 amp rating of 16 KA
(h) MCCB 4 pole , 63 amp rating of 16 KA
Design, supply, erection, testing and commissioning of outdoor type Change over panel box of overall size not less than 600mm width x 600mm Height x 400 mm depth (With Canopy & Base Channel) with, M.S. Channel Base Frame shall be mounted on the 3 side covered with brick, pedestal of height 600mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having on load Changeover switch of size 400 Amp . The panel box shall be duly fabricated in a approved / certified factory / fabrication house who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The panel box shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation etc complete all as directed and specified.
Design, supply, erection, testing and commissioning of outdoor type Change over panel box of overall size not less than 500mm width x 500mm Height x 400 mm Depth (With Canopy & Base Channel) M.S. Channel Base Frame shall be mounted on the 3 side covered with brick, pedestal of height 600mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having on load Changeover switch of size 200 Amp . The panel box shall be duly fabricated in a approved / certified factory / fabrication house who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The panel box shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation etc complete all as specified and directed.
Supply and fixing on load change over switch front handle operationin closed chamber and fixed in existing LT panel 4 pole 415 volts of capacity including taking down old unserviceable change over switch complete all as specified and as directed of the following sizes :-
(a) 63 amps
(b) 100/125 amps
(c) 200/250 amps
(d) 400/500 amps
M & L for detecting the fault of under ground LT cable by using fault locator machine including necessary excavation required for fault confirmation and opening of cable connection from panel and re connection after fault location using suitable materials etc complete all as specified and directed. Note : (i) The Fault locator machine shall be provided by the contractor as and when directed by engineer-in-charge. (ii) Joints shall be measured and paid separately under relevant items.
Supply and fixing PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor complete all as specified and directed of the following sizes:-
(a) 2 core, 4 Sqmm
(b) 2 core, 6 Sqmm
(c) 2 core, 10 Sqmm
M&L for Preparation of old painted surface of steel tubular poles of 9 mtr long including cross arms, cable protection pipe, bus bar box and painting of complete area with one coat of aluminium paint to a hight from 1.5 mtr above ground level to top of pole and making alternate strips/layers (30 cm wide) with white and blue synthetic enamel paint upto the 1.50 meter height from the ground level including writing the pole number in white letters on black background and cleaning/cutting the grass/bushes at a radius of 2 mtr surrounding the pole complete all as specified and directed.
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar Box of overall size not less than 1100mm width x 800mm Height x400 mm depth (With Canopy & Base Channel) M.S. Channel Base Frame shall be mounted on the 3 side covered with brick. pedestal of height 600mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 400 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication House who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 400 amps, . For all internal connections from main bus bars to MCCBS shall be carried out with heat shrink type PVC insulated aluminium flats of suitable size and from bus bars to MCBs with suitable size FRLS PVC insulated multi flexible type copper wires as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 35 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 250 Amps-01 Nos.
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar Box of overall size not less than 1000mm width x 800mm Height x 400mm Depth (With Canopy & Base Channel), M.S. Channel Base Frame mounted on the 3 side covered with brick,` pedestal of height 600mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 400 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication House who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 300 amps, . For all internal connections from main bus bars to MCCB shall be carried out with heat shrink type PVC insulated Gray aluminium flats of suitable size and from bus bars to MCBs with suitable size FRLS PVC insulated multi flexible type copper wires as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Grey Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 25 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 200 Amps-01 Nos.
OUTGOINGS :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA and thermal setting from 80% to 100% and of ratings :-63 Amps - 03 Nos (ii) 4 pole MCCB 40 Amps having breaking capacity 16 KA - 01 No (iii) MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 03 Nos. (iv) INSTRUMENTATION SYSTEM :- (a) LED Phase Indicating light, shrouded type, 22mm, with cluster LED suitable for 230 Volts AC - 01 set of 3 lamps (RED,YELLOW & BLUE) (b) Digital Multifunction meter - 01 N0 (c) C.T having Ratio 250/5, tape wound,BPL, rated burden 5 VA - 03 Nos. (d) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos
Design, supply, erection, testing and commissioning of indoor type LT Feeder Pillar Box of overall size not less than 1600mm width x 1200mm Height x 400mm Depth (With Canopy & Base Channel), M.S. Channel Base Frame shall be mounted on the 3 side covered with brick. pedestal of height 600mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 600 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication House who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 600 amps, . For all internal connections from main bus bars to MCCBS shall be carried out with heat shrink type PVC insulated aluminium flats of suitable size and from bus bars to MCBs with suitable size FRLS PVC insulated multi flexible type copper wires as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) 4 pole Changeover ( with panel mounted rotary handle ) having breaking capacity 35 KA, and of rating 400 Amps-01 Nos. (ii)4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 35 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 400 Amps-01 Nos.
OUTGOINGS :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA and thermal setting from 80% to 100% and of ratings :-100 Amps - 03 Nos (ii) 4 pole MCCB 63 Amps having breaking capacity 16 KA - 02 No (iii) MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 03 Nos. (iv) INSTRUMENTATION SYSTEM :- (a) LED Phase Indicating light, shrouded type, 22mm, with cluster LED suitable for 230 Volts AC - 01 set of 3 lamps (RED,YELLOW & BLUE) (b) Digital Multifunction meter - 01 N0 (c) C.T having Ratio 250/5, tape wound,BPL, rated burden 5 VA - 03 Nos. (d) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos
Design, supply, erection, testing and commissioning of indoor type LT Feeder Pillar Box of overall size not less than 900mm width x 800mm Height x 400mm Depth (With Canopy & Base Channel) , M.S. Channel Base Frame shall be mounted on the 3 side covered with brick, pedestal of height 600mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 250 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication House who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 250 amps, . For all internal connections from main bus bars to MCCBS shall be carried out with heat shrink type PVC insulated aluminium flats of suitable size and from bus bars to MCBs with suitable size FRLS PVC insulated multi flexible type copper wires as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Grey Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i)4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 160 Amps-01 Nos.
OUTGOINGS :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA and thermal setting from 80% to 100% and of ratings :-63 Amps - 02 Nos (ii) 4 pole MCCB 40 Amps having breaking capacity 16 KA - 01 No (iii) MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 03 Nos (iv) INSTRUMENTATION SYSTEM :- (a) LED Phase Indicating light, shrouded type, 22mm, with cluster LED suitable for 230 Volts AC - 01 set of 3 lamps (RED,YELLOW & BLUE) (b) Digital Multifunction meter - 01 N0 (c) C.T having Ratio 250/5, tape wound,BPL, rated burden 5 VA - 03 Nos. (d) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 1000mm width x 1000mm Height x 500mm Depth (With Canopy & Base Channel) , M.S. Channel Base Frame shall be mounted on the 3 side covered with brick, pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 400 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation.
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 750mm width x 750mm Height x 400mm Depth (With Canopy & Base Channel) , M.S. Channel Base Frame shall be mounted on the 3 side covered with brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 300 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation.
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 600mm width x 600mm Height x 400mm Depth (With Canopy & Base Channel) , M.S. Channel Base Frame shall be mounted on the 3 side covered with brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 200 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation.
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 500mm width x 500mm Height x 300mm Depth (With Canopy & Base Channel) , M.S. Channel Base Frame shall be mounted on the 3 side covered with brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 100 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation.
M&L for replacement of aluminium lugs for LT cable connection line suitable for system and fixed complete including taking down old unserviceable lugs and cables all as specified and directed of the following sizes :-
(a)16 to 35 Sq mm
(b) 50 to 120 Sq mm
(c) 240 to 400 Sq mm
M & L Painting to existing LT Panels, angle iron support bracings, clamps etc. with two coats of aluminium paint superior quality of approved make on external surfaces exposed to view external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
S&F in repair cable route indicator made out of MS sheet of size 30cmx20cm of 4mm thick with writing HT/LT cable with MS angle iron frame and two Nos legs of 1.2 m long of size 25x25x5mm fixed in ground with and including PCC (1:3:6) Type C-1 using 20mm graded aggregate of size15cmx15cm x15cm including painting with 02 coats of synthetic enamel paint of specified colour over one coat of red oxide primer complete all as specified and directed.
S&F in repairs 1.50 Mtr long house service bracket, made out of 40mm dia light grade GI pipe, bent to shape including MS hook & stay or guy and fixed to wall/ poles including all necessary nut/ bolts complete all as specified and directed.
S&F Weather Proof thermo plastic (Polysterene) Cable Junction box with 4 aluminium strip bar(25x3 mm) , having protection class IP-65 and of overall size 205mm x 255mm x 112mm having metric knockouts on the wall, having three phase cable connecter, duly fixed with the pole with clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps 4 Way cable connector and 1 No. 6 Amps SP MCB.
BHARADWAJ BROTHERS
Balaji Associates
M/S SINGH ELECTRIC CO
GUPTA ENGINEERING WORKS
SHRI HARI CONSTRUCTION
CHAHAR CONTRACTOR AND SUPPLIERS
MUKTA AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .