Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC | ₹2.3 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹2.3 Cr+₹4.6 L (2.02%)Rejected-Finance H NO 411 SECTOR 4 CHANNI HIMMAT JAMMU 180015 J K | JAMMU | JAMMU | J K | 180015 | ₹2.3 Cr+₹4.6 L (2.02%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹2.4 Cr+₹7.7 L (3.38%)Rejected-Finance | ₹2.4 Cr+₹7.7 L (3.38%) | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
18 Apr 2022, 6:00 pmClosed
CE UDHAMPUR ZONE
HQ CE UDHAMPUR ZONE PIN-900386 C/O 56 APO
PROVN OF ADM BLOCK FOR NCCIU UNDER GE (P) UDHAMPUR
2021_MES_490154_2
87870-A/E8
Open Tender
Civil Works
Lump-sum
510 days
UDHAMPUR
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE (P) UDHAMPUR
₹2.6 L
Yes
11 Aug 2022
19 Mar 2022
21 Apr 2022
19 Mar 2022
18 Apr 2022
4 Apr 2022
Amount
Total Amount of Sch 'A' Part - I (Building Work)
Total Amount of Sch 'A' Part - II (Site Clearance)
Total Amount of Sch 'A' Part - III (Internal Electrification)
Total Amount of Sch 'A' Part - IV (Internal Water Supply)
Total Amount of Sch 'A' Part - V (Plumbing Work)
Total Amount of Sch 'A' Part - VI (Sewage Disposal)
Total Amount of Sch 'A' Part - VII (Area Drainage)
Total Amount of Sch 'A' Part - VIII (Protective Work)
Total Amount of Sch 'A' Part - IX (Hard Standing)
Total Amount of Sch 'A' Part - X (Compound wall and gate)
Total Amount of Sch 'A' Part - XI (External Electric Supply)
Total Amount of Sch 'A' Part - XII (External Water Supply)
Total Amount of Sch 'A' Part - XIII (Air Conditioning & Refrigeration)
Sch 'A' Part - XIV (Misc Items work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
RCC NP3 150mm diameter pipes laid on 150 mm thick bed with excavation in any type of soil. Including manholes/drop manhole of standard size made of brick masonry/RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional, average depth 0.7m - 1.65m
RCC Septic tank 100 users capacity Conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 User.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chambeer made of Brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 M dia X 4.5 m effective depth
Blank
Voltage stablizer for automatic operation, single phase naturally cooled, indoor type and designed for input variation between 170 V to 250 V with output voltage stablized at 230 V with accuracy of +2.5% and capacity 2.00 KVA
Voltage stablizer for automatic operation, single phase naturally cooled, indoor type and designed for input variation between 170 V to 250 V with output voltage stablized at 230 V with accuracy of +2.5% and capacity 1.00 KVA
Voltage stablizer for automatic operation, single phase naturally cooled, indoor type and designed for input variation between 170 V to 250 V with output voltage stablized at 230 V with accuracy of +2.5% and capacity 4.00 KVA
Supply,installation,commissioning and testing of Refrigarator(5 star rating and frost free) comprising compressor,eletric driven (single phase) thermostat,refrigrant R-134a in pipe/coil as cooling fluid,condensor unit,capacity 195 ltrs,Single door and automatic power off as the cooling reached at peak point as per set all as specified & directed.
LED lamp 10 watts complete all as specified and directed by the Engr in Charge
Brick Masonry valve pit of size 105cm x 105cm x 105cm (internal dimensions) including excavation and earthwork in any type of soil, plastering all wall surfaces internally and flush pointing to brickwork externally as the work proceeds, complete including angle iron 40x40x5mm frame, MS sheet cover 3.15mm thick with 12mm dia handle, locking arrangement and painting with two coats of synthetic enamel paint over a coat of red oxide, Complete all as specified and directed.
Cutting existing water line connection 150mm and making suitable size for joining 50/40mm dia pipe including insert tee, welding, bending and necessary fitting etc
Blank
Blank
Blank
MCB Single pole 6 Amp- 32Amp, C curve
MCB Single pole and neutral, 240 volts 6 Amp- 32Amp, C curve
MCB Triple pole and neutral, 240 volts 6 Amp- 32Amp, C curve
LED tubelight 18/20/21W 4feet with LED tube rod integrated type 1P20, lumen output >95 lum/w, color temp 5700-6500K, CRI>80, THD <20%, PF>0.9, operating voltage 140-270V, extruded aluminium housing in poly carbonate cover body with all accessories prewired and connecting electrically to ceiling rose including using PVC insulated and overall sheathed, flexible copper conductor cable of suitable size, complete all as specified and directed.
LED tubelight 9/10W 2feet with LED tube rod integrated type 1P20, lumen output >95 lum/w, color temp 5700-6500K, CRI>80, THD <20%, PF>0.9, operating voltage 140-270V, extruded aluminium housing in poly carbonate cover body with all accessories prewired and connecting electrically to ceiling rose including using PVC insulated and overall sheathed, flexible copper conductor cable of suitable size, complete all as specified and directed.
Supplying, assembling, hanging and connecting ceiling fan 1200mm sweep, 5star rating of appropved make, with three blades, canop[y, downrod, and connecting up to regulator and switch including provision of flexible copper conductor cable 3core 23/0.0076 size from ceiling rose to ceiling fan and testing, complete all as specified and directed
Exhaust Fan of size 300mm, heavy duty plastic body, complete with louver speed 1300RPM, 230volts AC electrical operated 50HZ, complete all as specified and directed
45Watt, 1P66 LED Street light luminaries on GI bracket comprising of die cast aluminium housing with weather proof gasket of lamp and driver compartment with 120 degrees view angle, lumen output >100 lum/watt, lumen maintenance > 70%, THD <15%, PF>0.95 and LM 80 test compliance. The driver must be integrated with APFC short circuit protection, reverse polarity protection against 5KV high surges and comply with IEC 60598-1, IEC-61000-3-2, IEC 61547. The luminaire must have secondary optics with perfectly matched lens for better light control including making electrical connections with twin core twisted copper conductor, flexible copper wire of suitable size from street light to junction and including suitable size GI Bracket for fixing, Complete all as specified and directed.
Deduct Schedule of tree cutting and credit of Rs. (-) 2,55,745 (minus) as listed in schedule 'A' Part - XV. Lumpsum Contract Sum shall be arrived at after deducting the credit schedule amount. NOTE :- Tenderers will not quote against this item, being a firm amount
Mehar Enterprises
M/S VED PARKASH GUPTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .