Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | ₹1.3 Cr | L1 | Accepted-AOC Being as lowest tender |
| 2 | L2₹1.3 Cr+₹32,028 (0.24%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | ₹1.3 Cr+₹32,028 (0.24%) | L2 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
| 3 | L3₹1.4 Cr+₹2.3 L (1.75%)Rejected-Finance 1 206 SHOP NO 71 MANDIR MARKET SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | ₹1.4 Cr+₹2.3 L (1.75%) | L3 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
| 4 | L4₹1.6 Cr+₹28.4 L (21.3%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹1.6 Cr+₹28.4 L (21.3%) | L4 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
| 5 | L5₹1.8 Cr+₹43.6 L (32.7%)Rejected-Finance 08 PINK ENCLAVE MAHESH NAGAR BALAJI VIHAR GOPALPURA JAIPUR RAJASTHAN 302015 INDIA | JAIPUR | RAJASTHAN | 302015 | ₹1.8 Cr+₹43.6 L (32.7%) | L5 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
31 Jan 2022, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE Delhi Cantt-10
MISC REPAIR MAINT OF B R WORKS AT CPG MAIL ROAD CERTAIN UNITS AND MD ACCN AREA IN THE AOR OF AGE BR III UNDER GE EAST DELHI CANTT 10
2021_MES_497775_1
CWE/D-43/2021-22
Open Tender
Civil Works
Item Rate
180 days
Delhi Cantt
As per NIT
7 documents required · 7 mandatory
₹1,000
GE EAST DELHI CANTT
₹2.2 L
Yes
15 Feb 2022
28 Dec 2021
1 Feb 2022
28 Dec 2021
31 Jan 2022
18 Jan 2022
Amount
Taking down cement or cement lime plaster , any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and directed.
M & L 10-12mm thick polymer modified readymix cement based plaster Make : Ultratech (Brand name Readiplast) complying to IS-1661-1972, IS-2250-1965, IS-2402-1963) or equivalent as approved by GE, applied in ratio 1:4 as per manufacturer's instructions, on fair faces of brick masonry or concrete surfaces finished even and smooth, including taking down of existing cement or cmenet lime plaster of any thickness and any description on brick or stone walls including raking out joints, hacking for key and scrubbing down woith water, complete all as specified and as directed.
M & L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern (groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using aluminum battens, nailed to the under layer including removal of aluminum battens, repair to the edges of panels and finishing the groove) complete including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified.
demolition of existing brick/block masonry built in cement mortar complete all as directed.
M & L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 and complete all as specified and directed.
All as per item No. 07 above but except bricks complete all as specified and as directed.
Demolition or cement concrete (unreinforced) of any description and in any position
Cleaning of the existing drain including remove the drain cover safely and fixing again same position , any type and size & depth all in working/running conditions involving removal of blockage of any kind inclusive of soils, solids,silt,waste etc if any & water and prepared for repair / working condition complete all as specified and directed .
M&L for Plain cement concrete (1:3:6), type C-1 ( using 20 mm graded stone aggregate) as in drains /surface channel complete all as specified and directed .
M&L for Plain cement concrete 1:3:6 type C - 2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M & L for PCC (1:2:4) type B-0 using 12.50 mm graded stone aggregate as in brenching for manholes, drains, bands, coping, bed plate etc with slightly chamfered or rounded angles including necessary from work, if any, and finishing exposed surface even and smooth without using extra cement complete all as specified & directed.
Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete using extra cement including forms moulds mitred stopped ends etc complete all as specified and directed.
Excavation in trenches n.exc 1.5 M wide and n.exc 1.5 M in depth for foundations etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed
Excavation in trenches n.exc 1.5 M wide and exc 1.5 M but n.exc 3.00 M in depth for foundations etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning & filling including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removal of excavated material n.exc 50 mtr and depositing where directed at level not exc 1.5 M above the starting point complete all as specified and directed by Engr-in-Charge.
Demolition and breaking up 150 mm dia drain pipes (SGSW/ AC/RCC) including hunching and benching set in cement mortar and removal of debris from site and deposited where directed at a distance not exc 1KM from site complete all as specified and as directed.
Demolition and breaking up, 200 mm dia drain pipes (SGSW/ AC/RCC) including hunching and benching set in cement mortar and removal of debris from site and deposited where directed at a distance not exc 1KM from site complete all as specified and as directed.
Demolition and breaking up, 300 mm /600 mm dia drain pipes (SGSW/ AC/RCC) including hunching and benching set in cement mortar and removal of debris from site and deposited where directed at a distance not exc 1KM from site complete all as specified and as directed.
M & L for 150 mm dia (internal dia) RCC hume pipe class NP2 laid and and jointed complete with colleres and laid in trenches with laying pipes level and tested complete all as specified and as directed.
M & L for 200 mm dia (internal dia) RCC hume pipe class NP2 laid and and jointed complete with colleres and laid in trenches with laying pipes level and tested complete all as specified and as directed.
M & L for 300 mm dia (internal dia) RCC hume pipe class NP2 laid and and jointed complete with colleres and laid in trenches with laying pipes level and tested complete all as specified and as directed.
M & L for 600 mm dia (internal dia) RCC hume pipe class NP2 laid and and jointed complete with colleres and laid in trenches with laying pipes level and tested complete all as specified and as directed.
M& L for PCC 1:3:6 type C2 (using 40 mm grade stone aggregate) as in bed to drain pipe 150 mm bore including forming cradles complte all as specified and directed.
M& L for PCC 1:3:6 type C2 (using 40 mm grade stone aggregate) as in bed to drain pipe 200 mm bore including forming cradles complete all as specified and directed.
Cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 150 mm bore drain pipe complete all as specified and as directed.
Cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 200 mm bore drain pipe complete all as specified and as directed.
S & F Framed work such as in grills, gratings , mainhole cover ,water tank etc and similar work conforming to Fe-290 Gde -E-165 complete all as specified.
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for etc complete.
M&L for pre-cast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in manholes cover, drain cover and set in cement mortar (1:4) including necessary form work complete all as specified & directed.
M & L for RCC 1:2:4 (Nominal) Type B 1 (20 mm graded aggregate) as in slabs supported on walls, beams and columns in floors , roofs, landings , balconies, canopies, deck slabs and shelves etc complete all as specified and directed.
M & L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips etc complete all as specified and directed.
M & L for form work to sides and soffits of suspended slabs such as roof slabs , landings and similar work not exc 200 mm thick (horizontal or sloopping) for flat rough finished surfaces complete all as specified and directed.
M & L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and no pigment confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade, set in floors laid over 50mm thick sand cushioning layer and including dismantling old interlocking tiles etc complete all as specified and as directed.
M & L for 80 mm thickness, M-40 Grade, Pre-polished glossy finish precast concrete interlocking paver block (any shape , size & colour as approved by GE) confirming to IS 15658-2006 , set in floors laid over 50mm thick sand cushioning including dismantling old interlocking tiles etc complete all as specified and as directed.
M & L for 60 mm thickness, M-35 Grade, Pre-polished finish precast concrete interlocking paver block (any shape , size & colour as approved by GE) confirming to IS 15658-2006 , set in floors laid over 50 mm thick sand cushioning including dismantling old interlocking tiles etc complete all as specified and as directed.
M & L for Pre-polished, glossy finish, coloured chequered cement concrete tiles, factory made, Premium quality 300mm x 300mm x 25mm thick, set & jointed in neat cement slurry and pointed flush with grey cement and pigments to match colour of tiles in floors over 20 mm thick screed bed or bedding layer in cement mortar 1:6, including dismantling of exisiting chequred Concrete tiles of any type with bedding layer, complete all as specified and as directed.
M & L for factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required (Size and pattern as approved by GE) and including dismantling of old existing kerb stone of any type and size etc complete all as specified and as directed.
M & L for 18/20 mm thick granite (of any type) work( table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab including 10 mm thick screed bed in CM 1:4 complete including demolition of existing granite of any type all as specified and as directed.
M & L for Pre-polished, glossy finish, coloured , concrete cobble stone block 60 mm thick size 100mm x 100 mm up to 300 x 300 mm set in floors laid over 50mm thick sand cushioning complete all as specified and as directed.
M & L Heavy duty vitrified external designer floor tiles, parking tiles etc any colour, shape and size not less than 300 x 300 x 8 -10 mm thick , set & jointed in neat cement slurry and pointed flush with grey cement and pigments to match colour of tiles in floors over 15 mm thick screed bed or bedding layer in cement mortar 1:4, including dismantling of exisiting tiles of any type with bedding layer, complete all as specified and as directed.
M & L for plain cement concrete 1:2:4 ( type B-2 using 20 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges etc including necessary form work complete all as specified and directed.
M & L for 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing completed all as specified and directed.
75mm thick plain Cement Concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) finished even and fair at top without using extra cement and providing joints 40mm deep and 12 mm wide in plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, including demolition of PCC in ground floors and pavings not exceeding 15cm thickness, complete all as specified and as directed.
S & F in repair precast cement concrete type B0 1:2:4 (12.5 mm graded aggregates) louvres and jallies, 50 mm thick set in CM (1:4) (measured solid), including all mouldings but excluding frame (Pre cast frame shall be measured and paid seperately) complete all as specified and directed.
S & F precast RCC coping/post of size 600x100x50 mm suitable for fixing of RCC Jallies in vertically & horizontally including necessary moulds and grooves as required in shape and size complete all as specified and directed.
Dismantling old posts or struts ( wood, steel or RCC) any section, including taking out embedded portion and making good and excavation & prepration of post holes removal of surplus excavated material completed all as specified and directed
M & L for mild steel angle , flat iron as in post & strut including cutting tops to shape as directed drilling holes, notching for wire and similar work conforming to Fe 290 Gde 165 including erection in ground complete all as specified and directed.
S & F Chain link MS galvanisd fencing any size or type ( approved by GE) including line wires, any mesh, size and type to any of standards , rails , staining bolts, etc including provision of bindings wire complete all as specified and directed.
Dismantling mild steel work of any description not otherwise provided for.
S & F framed work such as in door frame, door shuters / gate of angel or other section with gusset plates, rails, braces, etc complete , drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hings or steel hanging door fittings, including hings hold fast of Fe 410-W (Gde E-250 quality) etc complete all as specified.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to IS 1161-1979 grade St-240 complete all as specified and directed
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws with bent to a curve (of any radius as per required) and including dismantling of plain or corrugated sheeting any gauge thickness including Nainital or similar pattern as in roof covering, complete all as specified and as directed.
S & F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour as in ridges hips, vally gutter, drip and straight flashing (length and girth as fixed) fixed with self tapping screws and welded or soldered joints are provided and including dismantling of plain or corrugated sheeting any gauge thickness including Nainital or similar pattern as in roof covering, complete all as specified and as directed. complete all as specified
S & F 2mm thick fiber glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc and including dismantling of plain or corrugated sheeting any gauge thickness including Nainital or similar pattern as in roof covering, complete all as specified and as directed. complete all as specified
M & L for application of 2 coats of damp block 2K on brick/conc/plastered surfaces duly preparation to existing surface complete.
Material and labour for Application of Professional wall putty 1.5mm thick with mixing vitalia water proofing compound. (Make : Asian Paint or equivalent) after Scrapping of the old surface including brooming down all old spots and algai etc to the complete satisfaction of GE all as specified and as directed.
Material and labour for application of Smart care damp proof of Asian Paint product or equivalent as follows:- (i) 1st Coat- Application of Self priming coat damp proof with 33% water . (ii) 2nd coat- Neat coat of damp proof after 4-6hrs drying of self priming coat or saturated surface drying condition. (iii) Third coat- Neat coat after 4-6 hrs after first neat coat or saturated surface drying Condition.
Material and labour for 2 coats of Asian paint apex ultima protek (coverage area 5-6 Sqm/Ltr) or equivalent including preparation of surface complete all as specified and as directed.
M & L for preparation of new plaster external wall and ceiling surfaces of upto 4 storey buildings, boundary walls and applying a layer of 1mm thick wall care putty, again sand papering thus making surface smooth and applying Two coats of weather proofing exterior acrylic emulsion paint premium quality on wall surfaces complete all as specified and directed. Allow 6-8hrs to dry the surface for painting of subsequent quotes complete all as specified and as directed by Engr- in-charge.
M & L for preparation of Old external wall and ceiling surface by complete removal of existing treatment of walls for upto 4 storey buildings and boundary walls by mechanised sander of Berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying a layer of 1mm thick wall care putty, again sand papering thus making surface smooth and applying Two coats of weather proofing exterior acrylic emulsion paint premium quality on wall surfaces complete all as specified and directed.
Material and labour for preparation of new surface decorated brick/concrete plastered or unplastered surfaces of walls, pillars, cornices by brooming down etc and applying two coat of cement base paint over a coat of cement primer etc complete all as specified and directed by Engr -in Charge.
M&L one coat of synthetic enamel paint (finishing coat) to old painted steel surfaces of any description as trusses , purlin ,rafters , ventilators etc over 10 cm width or girth incl prepration of surfaces complete all as specified.
M&L two coat of synthetic enamel paint (finishing coat) over one coat of primer to new steel surfaces of any description over 10 cm width or girth incl prepration of surfaces complete all as specified.
M & L for preparation of New and old stone, concrete surfaces of any description over 10 CM width or grith and applying two coat of plastic emulsion paint (colour and patren as per approved by GE ) complete all as specified and directed.
M & L Wall cladding tiles using tiles of size as per sample approved by GE set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in cement mortar 1:4 and including dismantling of old tiles with backing, complete all as specified and as directed
S & F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or as in spout, complete all as specified and as directed.
S & F in Stack clamps out of 50 mmx 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for bore of pipe 100mm complete.
S & F in repairs 110mm PVC (SWR) vent cowl complete.
R. S. Associates
A R construction
imran construction company
Simran construction Company
G and G Infratech Private Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .