| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC OLD DAILY MARKET DIMAPUR 797 112 NAGALAND | PEREN | NAGALAND | 797112 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹9.5 L+₹86,530 (9.99%)Rejected-Finance | L2 | Rejected-Finance Other Than Lowest Bidder |
| Sl No | Description | Qty | Unit | M/S MUNGA LAL PRASAD L1 | Shri Lakhinder Praasd L2 |
|---|---|---|---|---|---|
| 1.00 | S&F suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid, complete all as specified and as directed. | 49 | Sqm | 1,200 ₹58,800 Lowest | 1,220 ₹59,780 |
| 2.00 | M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FR-LSH cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed. | 42 | Per Point | 1,220 ₹51,240 | 1,210 ₹50,820 Lowest |
| 3.00 | All as per item serial No 2 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable and earth continuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board. | 5 | Per Point | 1,400 ₹7,000 Lowest | 1,600 ₹8,000 |
| 4.00 | S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed. | 42 | Each | 80 ₹3,360 Lowest | 90 ₹3,780 |
| 5.00 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB,20Amp, 240V, complete all as specified and as directed. | 5 | Each | 2,300 ₹11,500 Lowest | 2,500 ₹12,500 |
| 6.00 | S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece, 15mm bore GI pipe (medium grade) upto 2.5m long alongwith necessary fittings, 15mm bore PTMT stop cock(02Nos),15mm bore PTMT bib tap(02Nos), including cutting, threading and joining etc., with all conncections, complete all as specified and as directed. | 5 | Each | 34,000 ₹1,70,000 Lowest | 38,000 ₹1,90,000 |
| 7.00 | S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed. | 12 | Each | 70 ₹840 Lowest | 90 ₹1,080 |
| 8.00 | S & F LED tube fittings1x20W, 220V, with necessary fittings and fixtures including LED tube light and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed. | 5 | Each | 500 ₹2,500 | 410 ₹2,050 Lowest |
| 9.00 | S&F LED luminaire of size 600mmx600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roo ceiling including connecting up with driver three core flexible copper conductor of suitable size, complete all as specified and as directed. | 30 | Each | 3,000 ₹90,000 Lowest | 3,050 ₹91,500 |
| 10.00 | S & F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and as directed. | 7 | Each | 2,700 ₹18,900 Lowest | 4,590 ₹32,130 |
Tender Value
₹8.4 L
EMD Value
₹16,900
Closing Date
3 Sept 2025, 6:55 pmClosed
AGE (I) Zakhama
C/o 792 FPO PIN-900792 C/O 99 APO
PROVN OF FALSE CEILING IN BLDG NO T-739 INCLUDING INTERNAL ELECTRIFICATION,PROVN OF ELECTRIC CONNECTION NEAR BLDG NO. T-377 AND PROVN OF ELECTRIC METERS OF VARIOUS LOCATION AT ZAKHAMA MILITARY STATION UNDER AGE (I) ZAKHAMA
2025_MES_710050_4
8462/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Zakhama
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Zakhama
₹16,900
16 Sept 2025
9 Aug 2025
6 Sept 2025
9 Aug 2025
3 Sept 2025
16 Aug 2025
Amount
S&F suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid, complete all as specified and as directed.
M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FR-LSH cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item serial No 2 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable and earth continuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB,20Amp, 240V, complete all as specified and as directed.
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece, 15mm bore GI pipe (medium grade) upto 2.5m long alongwith necessary fittings, 15mm bore PTMT stop cock(02Nos),15mm bore PTMT bib tap(02Nos), including cutting, threading and joining etc., with all conncections, complete all as specified and as directed.
S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
S & F LED tube fittings1x20W, 220V, with necessary fittings and fixtures including LED tube light and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.
S&F LED luminaire of size 600mmx600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roo ceiling including connecting up with driver three core flexible copper conductor of suitable size, complete all as specified and as directed.
S & F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and as directed.
S & F single pole & neutral DBs 2 Ways, single door, suitable for mounting MCB, complete all as specified and as directed.
S & F single pole & neutral DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed.
S&F MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
S&F MCBs, SPN/DP 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
M&L for Sub main wiring with 2 runs of 2.5 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion and type of conduit complete all as specified and directed. (Note :For payment purposes, 2 runs of main cable (each of 1RM) 1 run of earth continuity cable (1RM) and one run of conduit (1RM) all together shall be considered as "1RM".
S&F 1100 volts grade heavy duty flat cable of size 16 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire complete all as specified and as directed.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I, complete all as specified and directed.
S&F electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH, incl PVC mounting box, necessary connections etc compete all as specified and directed. Make- L&T/HPL/BENLO/Secure or as approved by Engr-in-Charge.
S&F electronic meters temper proof LCD display with polycarbonate cover THREE PHASE 415 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH,incl PVC mounting box necessary connections etc compete all as specified and directed. Make- L&T/HPL/BENLO/Secure or as approved by Engr-in-Charge.
S&F pvc 10 sqmm insulated industrial single core unsheathed industrial multistrand cables with FRL-SH properties, with flexible bright annealed bare copper conductor for voltage grade upto 1100 v conforming to is-694:2010 / is 17048 in surface drawn in and including flexible pipe with fixtures complete all as specified and directed by engr-in-charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying cables, foundation for pole, etc and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming of soil in layers n. exc 25cm thick complete all as specified and as directed.
Removing excavated soil to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed.
Supplying, laying, jointing and testing XLPE insulated, screened, PVC bedded, galvanized steel strip, heavy duty, wire armoured electric LT power cable with stranded aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm x 4 core in trenches /along poles/on wall etc, complete all as specified and as directed Notes : - (i) Excavation and earth work, sand cushioning, protection covers shall be measured and paid for separately. (ii) Unless otherwise directed by the GE, the cable shall be procured by the contractor in single length (as manufactured) to meet the actual length of cable as required at site. However, for payment purpose, the length actually ordered & laid shall be measured and paid for.
Supply and fixing GI tubing, light grade, 50mm bore for protection of cable under road crossing, across drain, along electric pole or floor /wall etc, complete all as specified and directed.
Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid)
Supply and laying well burnt sub class ‘B’ bricks locally available best quality laid dry in trenches for protection of underground cable all as specified and directed
S & F Onload change over switch with SS Enclosure of capacity 63A, 415volts,4pole with necessary connections alongwith all required necessary accessories, complete all as specified and as directed. Note: Phase Barriers and Handle with door interlock kit is integral part of the Changeover Switch. Make: Havells, Cat No IHCNFE0063 or equvalent Can No of make L&T/Legrand as approved by AGE(I).
S & F single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar complete all as specified and as directed.
S&F MCBs, TPN, 40 to 100 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
M&L for plate earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and connected to 20x3mm copper strip as earthing lead by means of clamps, bolts, nuts and washer made of galvanised iron or steel and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I, complete all as specified and directed.
Shri Lakhinder Praasd (BID ID -3401013)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .