| Sl No | Description | Qty | Unit | SUPER MOTOR WINDING & REFRIGERATION WORK L1 |
|---|---|---|---|---|
| 1.00Supplying and laying of one number ISI marked PVC Insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size on surface as required. complete as directed by the Engineer-in-charge. | ||||
| 1.01 | 3x6 sq.mm | 130 | metre | 300 ₹39,000 |
| 2.00 | Providing and fixing Junction Box Fiber Reinforced Plastic material IP-65 Waterproof Electrical perfect for exiting pole /wall outdoor electrical installations. Complete as required. | 16 | each | 1,050 ₹16,800 |
| 3.00 | Providing and fixing Mounting Arm Solidly-built Steel housing, excellent corrosion resistant pipe bracket for Street light. including 150mm dia Stainless Steel U-bolt clamp10 mm thick. etc. complete as required. | 16 | each | 1,000 ₹16,000 |
| 4.00Supplying,Installation,Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).(Product shall be got approved by E-in-charge before supply that it fulfils the specification).warranty certificate shall be submitted. | ||||
| 4.10 | 50 watt | 5 | each | 2,400 ₹12,000 |
| 5.00Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).(Product shall be got approved by E-in-charge before supply that it fulfils the specification).warranty certificate shall be submitted. | ||||
| 5.10 | 30 watt | 16 | each | 2,830 ₹45,280 |
Updated dates
Tender Value
₹1.6 L
EMD Value
₹3,215
Closing Date
1 Jan 2026, 3:00 pmClosed
Executive Engineer
Assistant Executive Engineer (in-charge AC Division), Works Department, AC Division, IIT Delhi, Hauz Khas, New Delhi 110016
Providing and fixing of LED lights inside the shade area of Ramp in SATHI Building and backside of ITEC, Sonipat Campus
2025_IIT_890425_1
IITD/SNP//WORKS (SP- 5207)/2025
Open Tender
Electrical Works
15 days
IIT Delhi Hauz Khas
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹3,215
3 Feb 2026
18 Dec 2025
2 Jan 2026
18 Dec 2025
1 Jan 2026
18 Dec 2025
Supplying and laying of one number ISI marked PVC Insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size on surface as required. complete as directed by the Engineer-in-charge.
3x6 sq.mm
Providing and fixing Mounting Arm Solidly-built Steel housing, excellent corrosion resistant pipe bracket for Street light. including 150mm dia Stainless Steel U-bolt clamp10 mm thick. etc. complete as required.
Supplying,Installation,Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).(Product shall be got approved by E-in-charge before supply that it fulfils the specification).warranty certificate shall be submitted.
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).(Product shall be got approved by E-in-charge before supply that it fulfils the specification).warranty certificate shall be submitted.