Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.7 L+₹49,625 (9.59%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹5.9 L+₹67,995 (13.1%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹6.2 L+₹1.1 L (20.6%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹6.4 L+₹1.2 L (23.3%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹10.0 L
Closing Date
21 Jan 2021, 2:00 pmClosed
Executive Engineer
EandM Division, APWD, Prothrapur, Port Blair
Renovation of IEI to Male Ward Female Ward and Mortuary Room of PHC at Hut Bay Little Andaman
2021_APWD_1896_1
45/EE/EandM/20-21 2nd Call
Open Tender
Electrical Works
Item Rate
30 days
Little Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
19 Feb 2021
8 Jan 2021
22 Jan 2021
8 Jan 2021
21 Jan 2021
12 Jan 2021
9 Jan 2021 - 11 Jan 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required a) Group C i) Female Ward = 127 ii) Male Ward = 50 iii) Mortuary Room = 9 Total = 186 Point
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying of A.C Ceiling fan (1200 mm) sweep (Colour: White, Brown & Ivory) 5 Star rated without regulator i/c wiring down rod of standard length (upto 30 cm) with all accessories etc as required. Similar to make Havells Code No. ES-50 5 Star & ISI Marked or its equivalent.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying of Heavy Duty Exhaust Fan 450 mm Sweep 900 RPM (Metal Type) with accessories etc., as required similar to Havells- Model- Turbo Force SP or its equivalent
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. a) Upto 450 mm sweep
Supplying and Fixing of PVC Batten Holder as required similar to Havells Cat No. AHEMXW000 or its equivalent
Supplying and Fixing of MCB Protected Socket with 20 A MCB in Sheet Steel Enclosure i/c Connections similar to Havells Cat No. 20A MCB DBOXX COMBO or its equivalent.
Supplying of following sizes of XLPE insulated Heavy Duty armoured Aluminium Conductor UG Cable of 1.1 KV Grade Conforming to IS: 7098 (Part-I) and IS No. 1554 (Part-I) 1988 as applicable Make: CCI/Gloster / Havells/ Polycab/ Finolex a) 50 Sq.mm x 3.5 Core
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. A) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supplying of following and Laying of One Number Double Walled Corrugated High Density Poly thylene Pipe having Corrugation on the outer wall and Plain surface inner wall conforming to IS: No. 14930 Part-I & II complete with necessary HDPE filling for protection of 1.1 KV grade directly in ground at the depth of 50 cm i/c excavation and refilling the trench etc., as required. a) 50 mm outer dia & 38 mm inner dia
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. A) Above 35 sq. mm and upto 95 sq. mm
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 4 way (4 + 12), Double Door (TPN)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 6 way, Double Door (SPN)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required a) Single Pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required a) 40 A
Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2000mm, outer dia 50 mm, inner dia 25 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok)
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
M/s Sai Electrical Works
M K ENGINEERING
M/s G K Construction
V SURESH
POWER ENGINEERING CO
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .