| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.8 L+₹2.7 L (9.88%)Rejected-Finance 6TH CROSS STREET KAMARAJ NAGAR PALAYAMKOTTAI | PALAYAMKOTTAI | TIRUNELVELI | TAMIL NADU | 627002 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹37.7 L+₹10.6 L (39.0%)Rejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L3 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | LAKSHMI ELECTRICAL ENTERPRISES L3 | EVEREST ENGINEERING WORKS L1 | M/S POTHIRAJ AND CO L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of silent diesel Engine driven generating set 415 volts, 3 phase 4 wire engine of capacity 40 KVA as per IS: 10001/10002 and Alternator as per IS: 13364 complete with standard control panel, meter and sound proof canopy as per CPCB Norms-IV and foundation for DG Set and AMF Panel etc relay panel and switch gears for automatic starting on main failure of 40 KVA made out of 3.15 mm thick CRCA sheet outdoor type with vermin proof powder coated painting all as specified and directed by Engr-in-Charge.
NOTE FOR DG :
A). DIESEL ENGINE :
Diesel Engine rated 1500 rpm. Radiator Cooled Engine with CRDi System four stroke and three cylinder conforming to BS 5514/ ISO 3046.
(i) Electrical starter motor 12V DC
(ii) Battery charging alternator
(iii) Electronic Governor
(iv) Spin-on fuel filter
(v) Spin-on full flow lube oil filter
(vi) Residential Silencer
(vii) Air Cleaner (paper element type)
(viii) Recovery bottle
(ix) Safety for LLOP/ HWT
(x) Flywheel & Flywheel housing
(xi) First Fill to lube oil and coolant | 1 | Each | 9,50,000 ₹9,50,000 | 9,90,000 ₹9,90,000 | 9,40,000 ₹9,40,000 Lowest |
| 1.01B). ALTERNATOR : Synchronous Alternator of 40 KVA of 'H' class insulation suitable for continuous operation at 1500 rpm 230/ 415 Volts 0.8 to 1 pf (lag), 50Hz 3 phase 4 wire system conforming to BS 5000/ IS 4722, Brushless type screen protected revolving field, self excited, self regulated, (+-) 1.0 % Voltage Regulation (Max) in static conditions, Permissible overload 10% for one hour in 12 hrs operations. C). CONTROLLER : The genset control panel is manufactured with 3.15mm CRCA sheet and powder coated for a weather proof, long last finish. Control panel consist of following parts:- (i) Microprocessor based Engine Instrumentation. (ii) Graphical LCD display (iii) Individual phase current (Amps) (iv) Phase voltage (V) (v) Frequency (Hz) (vi) Lube oil pressure (kPa) (vii) Working hours (viii) MCB of suitable rating (ix) LED indication for main failure (x) Suitable current transformers (xi) Integrable with AMF D). Lube oil change period 500 hrs E). Sound proof canopy as per CPCB Norms-IV with inbuilt silencer F). Base Frame in MS iron material | ||||||
| 1.02G). AUTO MAIN FAILURE PANEL : (i) Line Volage Monitoring - 01 No (ii) 100 Amps ATS Switch - 01 No (iii) 240V AC Control Contactor - 02 No (iv) 12V Battery Charger - 01 No (v) Auto/ Manual Switch - 01 No (vi) 12V Relay - 02 No (vii) 220V AC Indicating Lamp - 02 No (viii) 6 Amps IP MCB for DC Control - 01 No (ix) 25 Sqmm Power wire - 01 No (x) 100Amps 4 way terminal - 03 No H). Drawing for foundation as recommended by manufacturer of DG Set and Panel to be produced to Engr-in-charge | ||||||
| 2.00 | Supply and laying 70 SQMM 3.5 Core LT UG cable, 1100 volts grade, XLPE insulated and sheathed, armoured, multistranded, heavy duty electric cable with aluminium conductor laid in trenches, ducts, on poles, walls, through pipes etc including identification tags over on cable complete including cable glands on both side terminations where necessary complete all as specified and directed by Engr-in-Charge. | 95 | RM | 750 ₹71,250 | 641 ₹60,895 Lowest | 700 ₹66,500 |
| 3.00 | Excavation in trenches not exc. 1.5 m wide and not exc.1.5 m deep for laying of cable, pipe and for erecting of steel tubular swaged pole etc, and getting out in hard/dense soil complete all as directed by Engg-in-charge. | 18 | Cum | 350 ₹6,300 | 320 ₹5,760 Lowest | 400 ₹7,200 |
| 4.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as directed by Engg-in-charge. | 16 | Cum | 110 ₹1,760 | 45 ₹720 Lowest | 90 ₹1,440 |
| 5.00 | Removing excavated material not exc 50 meters and depositing where directed at a level not exceeding 1.5 mtr above the starting points in soil all as directed by Engineer-in-Charge. | 2 | Cum | 110 ₹220 | 75 ₹150 Lowest | 250 ₹500 |
| 6.00 | Supply and Laying of HDPE DWC Pipe medium grade of size 90mm outer Dia for protection of XLPE UG cable complete all as directed by Engg-in-charge. | 95 | RM | 300 ₹28,500 Lowest | 430 ₹40,850 | 320 ₹30,400 |
| 7.00 | Earthing with galvanised steel earth plate electrode 60cmX60cmX6mm thick, buried directly in Ground vertically at a depth not less than 2.25 METRE below Ground Level with the Top Edge of Earth Plate at a depth not less than 1.50 METRE below Ground Level connected to galvanised iron strip of size 32x6mm as Earthing Lead by means of Bolts, Nuts, Check Nuts and Washers of galvanised iron , Earth Plate Electrode surrounded by a packed thickness of Charcoal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, GI Strip protected with and including 40mm bore GI Light Grade Pipe up to 1.0 METRE above the Floor Level of the Building where Main Switch/DB situated including PCC Pit in Cement Concrete (1:3:6) type C1 (20mm Graded Stone Aggregate) and RCC Cover of size 450X450X50mm in RCC (1:2:4) type B1 (20mm Graded Stone Aggregate) reinforced with and including 8.0mm Dia TMT Bars @ 100mm centre to centre both ways, GI Wire Mesh, Funnel, 20mm bore Medium Grade GI Watering Pipe, necessary Excavation in Soft/Loose Soil, returning, filling in and removal of surplus Spoil up to a distance of 50.00 metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion as specified and directed by the Engineer-in-Charge. | 5 | Each job | 6,500 ₹32,500 Lowest | 7,000 ₹35,000 | 11,000 ₹55,000 |
| 8.00 | Removing/ shifting and refixing the main supply cable from existing LT feeder/ transformer to proposed AMF panel for unaltered power supply complete all as specified.
Note : Rate quoted is inclusive of tools, plants/ machinery used for the work. | 1 | Each Job | 9,500 ₹9,500 | 10,000 ₹10,000 | 5,000 ₹5,000 Lowest |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
20 May 2026, 6:00 pmClosed
GE TIRUNELVELI
Garrison Engineer Naval Post Base Vijayanarayanam Tirunelveli -627119
PROVISION OF STANDBY DG SET 40 KVA AND SPECIAL REPAIR FOR REPLACEMENT OF BER SUMMER APPLIANCES AND WATER SUPPLY EQUIPMENTS AT INS KATTABOMMAN UNDER GE TIRUNELVELI
2026_MES_762658_1
GE/TVL/8625/E8 of 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VIJAYANARAYANAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE TIRUNELVELI
₹59,000
Yes
16 Jul 2026
29 Apr 2026
22 May 2026
29 Apr 2026
20 May 2026
13 May 2026
30 Apr 2026 - 9 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of silent diesel Engine driven generating set 415 volts, 3 phase 4 wire engine of capacity 40 KVA as per IS: 10001/10002 and Alternator as per IS: 13364 complete with standard control panel, meter and sound proof canopy as per CPCB Norms-IV and foundation for DG Set and AMF Panel etc relay panel and switch gears for automatic starting on main failure of 40 KVA made out of 3.15 mm thick CRCA sheet outdoor type with vermin proof powder coated painting all as specified and directed by Engr-in-Charge.
NOTE FOR DG :
A). DIESEL ENGINE :
Diesel Engine rated 1500 rpm. Radiator Cooled Engine with CRDi System four stroke and three cylinder conforming to BS 5514/ ISO 3046.
(i) Electrical starter motor 12V DC
(ii) Battery charging alternator
(iii) Electronic Governor
(iv) Spin-on fuel filter
(v) Spin-on full flow lube oil filter
(vi) Residential Silencer
(vii) Air Cleaner (paper element type)
(viii) Recovery bottle
(ix) Safety for LLOP/ HWT
(x) Flywheel & Flywheel housing
(xi) First Fill to lube oil and coolant | 1 | Each | - | - |
| 1.01 | B). ALTERNATOR :
Synchronous Alternator of 40 KVA of 'H' class insulation suitable for continuous operation at 1500 rpm 230/ 415 Volts 0.8 to 1 pf (lag), 50Hz 3 phase 4 wire system conforming to BS 5000/ IS 4722, Brushless type screen protected revolving field, self excited, self regulated, (+-) 1.0 % Voltage Regulation (Max) in static conditions, Permissible overload 10% for one hour in 12 hrs operations.
C). CONTROLLER :
The genset control panel is manufactured with 3.15mm CRCA sheet and powder coated for a weather proof, long last finish. Control panel consist of following parts:-
(i) Microprocessor based Engine Instrumentation.
(ii) Graphical LCD display
(iii) Individual phase current (Amps)
(iv) Phase voltage (V)
(v) Frequency (Hz)
(vi) Lube oil pressure (kPa)
(vii) Working hours
(viii) MCB of suitable rating
(ix) LED indication for main failure
(x) Suitable current transformers
(xi) Integrable with AMF
D). Lube oil change period 500 hrs
E). Sound proof canopy as per CPCB Norms-IV with inbuilt silencer
F). Base Frame in MS iron material | - | - | - | - |
| 1.02 | G). AUTO MAIN FAILURE PANEL :
(i) Line Volage Monitoring - 01 No
(ii) 100 Amps ATS Switch - 01 No
(iii) 240V AC Control Contactor - 02 No
(iv) 12V Battery Charger - 01 No
(v) Auto/ Manual Switch - 01 No
(vi) 12V Relay - 02 No
(vii) 220V AC Indicating Lamp - 02 No
(viii) 6 Amps IP MCB for DC Control - 01 No
(ix) 25 Sqmm Power wire - 01 No
(x) 100Amps 4 way terminal - 03 No
H). Drawing for foundation as recommended by manufacturer of DG Set and Panel to be produced to Engr-in-charge | - | - | - | - |
| 2 | Supply and laying 70 SQMM 3.5 Core LT UG cable, 1100 volts grade, XLPE insulated and sheathed, armoured, multistranded, heavy duty electric cable with aluminium conductor laid in trenches, ducts, on poles, walls, through pipes etc including identification tags over on cable complete including cable glands on both side terminations where necessary complete all as specified and directed by Engr-in-Charge. | 95 | RM | - | - |
| 3 | Excavation in trenches not exc. 1.5 m wide and not exc.1.5 m deep for laying of cable, pipe and for erecting of steel tubular swaged pole etc, and getting out in hard/dense soil complete all as directed by Engg-in-charge. | 18 | Cum | - | - |
| 4 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as directed by Engg-in-charge. | 16 | Cum | - | - |
| 5 | Removing excavated material not exc 50 meters and depositing where directed at a level not exceeding 1.5 mtr above the starting points in soil all as directed by Engineer-in-Charge. | 2 | Cum | - | - |
| 6 | Supply and Laying of HDPE DWC Pipe medium grade of size 90mm outer Dia for protection of XLPE UG cable complete all as directed by Engg-in-charge. | 95 | RM | - | - |
| 7 | Earthing with galvanised steel earth plate electrode 60cmX60cmX6mm thick, buried directly in Ground vertically at a depth not less than 2.25 METRE below Ground Level with the Top Edge of Earth Plate at a depth not less than 1.50 METRE below Ground Level connected to galvanised iron strip of size 32x6mm as Earthing Lead by means of Bolts, Nuts, Check Nuts and Washers of galvanised iron , Earth Plate Electrode surrounded by a packed thickness of Charcoal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, GI Strip protected with and including 40mm bore GI Light Grade Pipe up to 1.0 METRE above the Floor Level of the Building where Main Switch/DB situated including PCC Pit in Cement Concrete (1:3:6) type C1 (20mm Graded Stone Aggregate) and RCC Cover of size 450X450X50mm in RCC (1:2:4) type B1 (20mm Graded Stone Aggregate) reinforced with and including 8.0mm Dia TMT Bars @ 100mm centre to centre both ways, GI Wire Mesh, Funnel, 20mm bore Medium Grade GI Watering Pipe, necessary Excavation in Soft/Loose Soil, returning, filling in and removal of surplus Spoil up to a distance of 50.00 metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion as specified and directed by the Engineer-in-Charge. | 5 | Each job | - | - |
| 8 | Removing/ shifting and refixing the main supply cable from existing LT feeder/ transformer to proposed AMF panel for unaltered power supply complete all as specified.
Note : Rate quoted is inclusive of tools, plants/ machinery used for the work. | 1 | Each Job | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
8625TENDERDOCS.pdf
Tender Documents • 0.78 MB
BOQ_854299.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .