Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC RANGIYA STATION ROAD WARD NO 2 PO RANGIYA DIST KAMRUP ASSAM PIN 781365 | BAKSA | ASSAM | 781365 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹15.9 L+₹42,276.26 (2.73%)Rejected-Finance | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹16.0 L+₹48,598 (3.14%)Rejected-Finance RANGIYA TINIALI POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹16.4 L+₹89,546 (5.78%)Rejected-Finance | L4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L5₹17.0 L+₹1.5 L (9.62%)Rejected-Finance C O DR UMASHANKAR SHARMA RANGIYA TINIALI NEAR RAIL GATE POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L5 | Rejected-Finance BEING L5 BIDDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 Feb 2021, 6:00 pmClosed
GE RANGIA
GE Rangia GE Rangia C/O 99 APO Rangia
SPECIAL REPAIR TO BUILDING NO. ET-225 AND OTHER SANCTIONED WORK AT HATTIGOR MILITARY STATION UNDER GE RANGIA
2021_MES_409739_1
8441/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
HATTIGOR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE RANGIA
₹40,000
Yes
20 Feb 2021
5 Jan 2021
3 Feb 2021
5 Jan 2021
1 Feb 2021
19 Jan 2021
Amount
Dismantling Unframed timber scantlings 40 Sqcm and over in section and in any position, complete all as specified and as directed by Engineer-in-charge.
M&L 2nd class hard wood in scantling wrought timber unframed and fixed, complete all as specified and as directed by Engineer-in-charge.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing, complete all as specified and as directed by Engineer-in-charge.
M&L for G I Wire netting 0.9 mm dia and 12 mm mesh lathing to wood or metal studding, joists, etc., in walls, ceilings, stanchions, beams, etc., including all laps, cutting and waste, complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge.
M&L for 15 mm thick rendering on fair faces of brick work or one side of lathing in cement mortar (1:4) and surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
M&L rendering 10mm thick on other than fair faces of brick work or on other side of lathing in cement mortar 1:6, surface to be finished fair & even without using extra cement, complete all as specified and as directed by Engineer-in-charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation,etc) or insulation board/Slabs/blankets of any thickness including cover fillets, complete all as specified and as directed by Engineer-in-charge.
S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600x600mm comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x30x0.70mm with 4mm dia GI wire as suspender and including 4mm thick non-asbestos cement building board including fixing arrangement and applying two coat of oil bound distemper over one coat of chalk whiting, complete all as specified and as directed by Engineer-in-charge.
M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in flooring/ hard standing/pavings/plinth protections, finished even and smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
Taking down shutters of any description not exc. 1 sqm each, complete all as specified and as directed by Engineer-in-charge.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each, complete all as per specified and as directed by Engineer-in-charge.
S&F 30 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. for windows and ventilators etc complete all as per specified and as directed by Engineer-in-charge.
S&F 35 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge.
S&F GI wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with tinned tacles or galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F 100 mm long extruded Aluminium alloy anodised butt hinges with galvanized mild steel hinge pin type C-21, complete all as per specified and as directed by Engineer-in-charge.
S&F 150 mm long extruded Aluminium alloy handles, fabricated type, anodised, complete all as per specified and as directed by Engineer-in-charge.
S&F aluminium alloy 300 mm anodised sliding door bolts with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast - aluminium alloy, complete all as specified and as directed by Engineer-in-charge.
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of oil bound distemper on walls including one coat of chalk whiting primer, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing old distempared surfaces including washing, rubbing down and stopping and applying one coat of oil bound distemper on walls, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of cement based paint on walls over a coat of alkali resistant primer, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing old painted surfaces including washing, rubbing down and stopping and applying one coat of cement based paint on walls, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing surfaces of wood and wood based materials, new or old of any description and girth, not otherwise described and treated with two coats of cresote oil, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old painted surfaces of wood and wood based materials of any description, not otherwise described and applying one coat of synthetic enamel paint over 10 cm width or girth, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated wood or wood based surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as per specified and as directed by Engineer-in-charge.
S&F coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:4 complete all as per specified and as directed by Engineer-in-charge.
M&L for Coloured Glazed ceramic tiles 300 x 200 x 6 or 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 10 mm thick screed in CM (1:4) complete all as per specified and as directed by Engineer-in-charge.
Demolition of unreinforced cement concrete in ground floors and pavings not exc. 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificied provided for, complete all as per specified and as directed by Engineer-in-charge.
M&L for reinforced cement concrete type B-1 (1:1.5:3) M-20 nominal mix (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
M&L for for precast cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work built in any cement mortar complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
M&L for brick work with sub-class `B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:4), mixing with water proofing compound @ 3% by weight of cement consumed and surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. Note: WPC shall be measured and paid separately.
Supply only integral water proofing compound confirming to IS complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D2 ( using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge.
M&L for 50 mm thick cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in floors, finished even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
Dismentling and breaking up 150 mm bore drain pipes (salt glazed ware) set in cement mortar bedding and hauching including necessary earth work as required complete all as per specified and as directed by Engineer-in-charge.
M&L for concrete bed to 150mm dia drain pipes including packing under & haunching against the sides of pipes with concrete after they are laid & tested in PCC (1:4:8) type D2 (using 40 mm graded crushed stone aggregate) complete all as per specified and as directed by Engineer-in-charge.
M&L of Reinforced concrete pipes of size 150mm, class NP2, laid and jointed complete with collars complete all as specified and directed by Engineer in Charge.
M&L for PCC (1:2:4) type B-1 ( using 20 mm grade crushed stone aggregate) as in benching, copping including weathering, slightly rounded or chamfered angles including necessary form work as required complete all as specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 6 to 8 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends complete all as specified and as directed by Engineer-in-charge.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for pipe of internal dia. 150mm, complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully aluminum/copper point wiring (light fan, socket or power) complete incl fittings and fixtures such as switches, sockets, light fittings, ceiling rose, pendants, lamp holders, shade conical, regulators etc and removing unserviceable fittings and fixtures with wiring cable, battens, wooden boards etc from site and making good disturbed surfaces of walls, floors, ceiling etc all complete all as specified and directed complete all as per specified and as directed by Engineer-in-charge.
Taking down carefully unserviceable main switches and DB’s including wooden boards, MCBs and removing from site including making good disturbed surfaces of walls complete all as per specified and as directed by Engineer-in-charge.
Dismantling of house service brackets of any size and type and making good the distrubed wall surfaces complete all as per specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends . elbow crosses etc with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings etc like switches sockets and fan regulator incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly complete all as specified and as directed for one light point controlled by one switch, complete all as per specified and as directed by Engineer-in-Charge.
All as per Serial item No. 55 above but for one fan point controlled by one switch complete all as per specified and as directed by Engineer-in-Charge.
All as per Serial item No. 55 above but for one 3 pin socket outlet 5 AMPs on independent board complete all as per specified and as directed by Engineer-in-Charge.
All as per Serial item No. 55 above but for one 3 pin socket outlet 5 AMPs on same board complete all as per specified and as directed by Engineer-in-Charge.
All as per serial item no. 55 above but with 4 sqmm (nominal area) cable with 4.00 sq mm size copper earth continuity conductor of green colour for 15 A socket outlet on independent boards.
S&F switch piano, flush type, single pole, one way, 5 Amps, 230 volts complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 230 volts, flush type, 3 pin 5 Amp flush type piano universal type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 05/6 Amp 3 pin flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 05/16 Amp 6 pin flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling fan regulator electronic stepping type, rotary step, SP 230 Volt including necessary electric connection, complete all as specified and as directed by Engineer-in-charge.
Supply and fix lamp holder, PVC/Polycarbonate type with back plate including 10 watt LED bulb complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED tube light fittings with regal batten for LED, wall mounted, extruded head dissipation with crystal gladd LED tube light (double side connection) 18 W LED 4', 230 V complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to tube light fitting complete all as specified and as directed by Engineer-in-charge.
S&F PVC rectangular block for mounting, DBs, etc. with 3mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm deep complete all as specified and as directed by Engineer-in-charge.
S&F sheet metal enclosure for double door SPN 12 Ways DB when MCBs to be used single pole neutral 240 Volts with 200 A bus bar, complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SPN 240 Volts 40 Amp breaking capacity 10 KA rating complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SP 240 Volts 6 to 32 Amp breaking capacity 10 KA rating complete all as specified and as directed by Engineer-in-charge.
S&F 1100 volts grade heavy duty 16 sqmm cable PVC insulated stranded aluminum conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connection twin core cable flat or circular including taking down old unserciveable cable, complete all as specified and as directed by Engineer-in-charge.
Taking down old ceiling/exhaust fans of any sweep by disconnecting electric connection, and removing fan to MES STORE YARD OF AGE E/M RANGIA for Check-ing and cleaning including refixing it to its original position after proper testing, complete all as specified and as directed by Engineer-in-charge.
S&F security light fittings 1x 15 Watt LED New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP openning seperate driver compartment with IP65 protection and impact resistance of IK07 and including connection up with twine core twisted flexible copper conductor cable with 1.5 M long suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F House service bracket (Hook type) complete with 40 mm dia GI pipe 3.00 m long, medium grade, two Nos. of 90 degree bends, M.S hook and stay or guy complete all as per specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
S&F in repair street light bracket made out of GI tubing 25 mm bore medium grade 1.20 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 40mm x 5mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S SITAL BUILDERS
M/S Bhaskar Construction
G.K. TRADERS
M/S S.S. Construction
M/S Rajkamal Enterprise
SYED ATAUR RAHMAN
M/S KIRAN ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .