Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹22.8 L+₹37,391.80 (1.67%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹24.8 L+₹2.4 L (10.5%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹25.4 L+₹3.0 L (13.5%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹26.7 L+₹4.3 L (19.0%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹35.0 L
EMD Value
₹69,940
Closing Date
24 Nov 2021, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIRS AND MAINTENANCE TO SEWAGE LINE COMPOUND WALL FENCE AND MISC REPAIR AT TB II UNDER AGE BR P IN GE C KIRKEE
2021_MES_484704_1
8532/E8 OF 2021-2022
Open Tender
Civil Works
Item Rate
270 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹69,940
11 Dec 2021
28 Oct 2021
27 Nov 2021
28 Oct 2021
24 Nov 2021
12 Nov 2021
28 Oct 2021 - 11 Nov 2021
Amount
Cleaning of existing septic tank of 500 users capacity by using Mechanical Pumping Machine to removing water, sludge, stones, solid particles etc complete from the septic tank at any location and at distance from road and removing the same from the campus and buried complete all as specified and as directed as below: (i) The sludge/burried soil etc taken out shall be stacked alongwith the septic tank, sump well etc. After 48 hours of the sludge taken out, measurement shall be taken as of the solid contents for the purpose of payment. The tenderer are advised to keep this aspect in mind while quotating the rates. After taking the measurements, the solid contents shall be disposed off outside the Md land/area. (ii) Necessary precautions as well as safety measures shall be taken by the contractor without any extra cost, for working in the foul conditions. (iii) The contractor shall be entirely responsible for the lapse, mishappening to any of the manpower deployed and/or to other equipment/machinary/material at the site of work during the execution.
All as specified in item No 1 above but septic tank for 200 users.
All as specified in item No 1 above but filter bed for 500 users.
Excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for sewage line foundation etc or for manholes, laying pipes etc and getting out in any type of soil.
Excavating in trenches exc. 1.5 m depth and n. exc. 3.0 m in depth; for Ssewage line foundation etc or for manholes, laying pipes etc and getting out in any type of soil.
M&L for reinforced concrete pipes, 150 mm bore, class NP-2, laid and jointed complete with collars including demolition and breaking up existing unserviceable drain pipes ( salt glazed ware AC/RCC) set in cement mortar, dia of pipe 150mm complete all as specified and as directed.
All as per item No. 6 here-in-before but dia of pipe 200mm complete all as specified and as directed.
Demolition of cement concrete unreinforced in ground floors and pavings n. exc. 15cm thickness in any position complete all as specified and as directed.
Demolition Brickwork or stone/boulder masonry, built in lime mortar or cement mortar including all quoins, arches, pillars, etc, including ashlar facings, dressed stonework and precast concrete articles as in manhole including PCC coping complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded coarse aggregate in bed to drain pipes including packing under, and hanching against the side after they are laid and tested for pipes of 150 mm bore complete all as specified and as directed.
All as per item No. 10 here-in-before but for drain pipes of 200 mm complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded coarse aggregate in foundation filling and mass conerete complete all as specified and as directed.
M&L for reinforced concrete pipes, 300 mm bore, class NP-2, laid and jointed complete with collars including demolition and breaking up existing unserviceable drain pipes ( salt glazed ware AC/RCC) set in cement mortar, dia of pipe 300mm complete all as specified and as directed.
M&L for precast cement concrete block masonry of grade C-5 having density not less than 1800 kg/cum and 28 days average minimum compressive strength of block should be 5 N/sqmm as in walling set in cement mortar 1:6 complete all as specified and as directed.
M&L for PCC 1:3:6 Type C-1 using 20 mm graded coarse aggregate in coping including necessary formwork complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1:4 on concrete block masonry surfaces mixed with WPC @ 3% by wt of cement and finished even and smooth without using extra cement complete all as specified and as directed. (Note : WPC shall be measured and paid separately)
Supply only integral water proofing compound.
Returning, filling in soil spreading, levelling, watering and well ramming in layers n. exc. 25 cm. complete all as specified and as directed.
Removing excavated soil n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and as directed.
M & L for precast reinforced cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in manhole covers, septic tank slab, drain cover etc set in CM 1:6 including demolition of existing RCC manhole covers including RCC slab set in cement mortar complete all as specified and as direcetd by Engineer-in-charge.
M & L for mild steel TMT bar 10mm dia and over cut to length,bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as direcetd by Engineer-in-charge.
Ditto all as per item No 21 but 6mm to 8mm dia TMT bar complete all as specified and as direcetd by Engineer-in-charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as direcetd by Engineer-in-charge.
M & L for cleaning of all blockage of sewerage of any type sewerage line, branch line main sewer line, etc of any section and that any situation by way of cleaning/desludging by using mechanically or pumping out sewage from block manholes where required and directed by Engineer-in-charge and keeping sewer line functional. Day-to-day complaints of chocked up manholes, sewage lines etc. Cleaning the trap WC, soil waste, vent pipe, gully traps, upto final drop outlet, inlet of septic tank working in foul condition with taking precautionary measures, equipments and required power/cable Pertaining to TB-II OTM Accn and MD Accn are to be received daily from the Complaint Cell situated in the premises of office of the AGE B/R (P) Kirkee and entire complaints are to be attended for cleaning on the same day. Minimum number of labourers with specialised experience will not be less than 03 Nos safaiwals from 0830 hrs to 1700 hrs. Note : (i) The payment towards the subject items shall only be made as per the total number of days, contractor had cleaned and cleared the blockages of sewage line. (ii) In case urgent nature of complaints, contractor has to attend the complaints even on Sundays and holidays also (iii) Contractor shall maintain a register including details of day of cleaning of sewage line, duly signed by contractor and Engineer-in-Charge. If the contractor will not able to provide the man power, the recovery of Rs. 629/- per person pe day will be deducted. ( For day to day cleaning contractor have to procure mechanically oparated equipments like KAMBORE NM, KAMBORE CC, KAMROD, KAMBORE 1075, KAMBORE ST 300-700, KAMBOBE TM-CNR-GD or equivalant equipment to attend daily complaints no extra cost paid to contractor for procuring equipments )
S&F in repair plastic seat for water closet , white/black closet pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as direcetd by Engineer-in-charge.
S&F in repair vitreous china wash down water closet pan (Padestal pattern) white excluding flushing cistern & flush pipe including connection to out going pipe and flushing pipe complete all as specified and as direcetd by Engineer-in-charge.
S&F in repair water closet vitreous China (Orrisa pattern) size 580mm x 440mm white with complete with foor rest including connection WC pan to trap and to flushing pipe, anti syphonage pipe etc complete including making good to floor complete all as specified and as direcetd by Engineer-in-charge.
S & F in repair PVC High/Low level flushing cistern 10 litres capacity including all fittings i.e float valve, syphon, flush pipe, brackets complete all as specified and as direcetd by Engineer-in-charge.
S & F in repair vitreous china wash hand basin white flat back size 550 x 400 mm excluding taps waste chain and plug and porcelain stopper but including necessary brackets, brass CP wastes and other fittings complete all as specified and as direcetd by Engineer-in-charge.
S&F in repair PVC (SWR) Bends (any radius ), diminishing pieces or tapers, bore of pipe 75mm, complete all as spcified.
S&F in repair PVC (SWR) Bends (any radius ), diminishing pieces or tapers, bore of pipe 100mm, complete all as spcified.
S&F in repair PVC (SWR) Branch pieces, double (double Y )equal or unequal of pipe 75mm bore complete all as spcified.
S&F in repair PVC (SWR) Branch pieces, double (double Y )equal or unequal of pipe 110mm bore complete all as spcified.
S&F in repair PVC (SWR) pipes, single socketed, in any length, with rubber rings 75mm dia laid in trenches or floor or fixed to wall complete all as spcified.
S&F in repair PVC (SWR) pipes, single socketed, in any length, with rubber rings 100mm dia laid in trenches or floor or fixed to wall complete all as spcified.
M & L Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 15mm thick screed bed in CM (1:6) including Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and as directed by Engr-in-Charge.
M & L for Non skid coloured Ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile excieeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 15mm thick screed bed in CM (1:6) including Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and as directed by Engr-in-Charge.
M & L for Glazed coloured Ceramic tiles (300x200mm) or (350x250) or 450x350) x 7 mm thick in Dado/Skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 10 mm thick backing coat in CM (1:4) including Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and as directed by Engr-in-Charge.
S&F in repair vitreous China bowl urinal flat back size 465mm x 355mm x 265mm white with grating and union for discharge pipe including providing and fixing pligs bedding urinal against wall in cm 1:2 securing urinal with plug all as specified.
S&F in repair Low density polyethylene pipes (LDPE) 40mm bore of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. to urinal pot as waste pipe all as specified and as directed by Engr-in-Charge.
S&F in repair angular / stop valves cast copper alloy CP fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for pipe or union fixed for 15mm bore complete all as specified and as directed by Engr-in-Charge.
S&F in repair 15mm bore bib tap cast copper alloy fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by Engr-in-Charge.
S& F in repair 15mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed by Engr-in-Charge.
S&F steel tubing medium grade 15mm bore galvanised with all fittings fixed including taking up or down unserviceable GI tubing of 15mm bore fixed to walls and ceilings or laid in floors complete all as specified and as directed by Engr-in-Charge.
S&F steel tubing medium grade 20mm bore galvanised with all fittings fixed including taking up or down unserviceable GI tubing of 20mm bore fixed to walls and ceilings or laid in floors complete all as specified and as directed by Engr-in-Charge.
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) complete all as specified and as directed by Engr-in-Charge.
S&F in repair 32/40 mm bore PVC flxible waste pipe suitable for WHB, Urinals etc complete all as specificed and as directed.
S&F in repair High density polyethylene pipes (HDPE) 32mm bore of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. as a flush pipe to flushing cistern complete all as specified and as directed by Engr-in-Charge.
S&F in repair Cast iron Nahani trap, with grating 100mm including jointing to wast pipe fixed in cement concrete type B1 (1:2:4), including water leak proof treatment complete all as specified and as directed.
S&F in repair Cast iron floor trap, with grating 75mm including jointing to wast pipe fixed in cement concrete type B1 (1:2:4), including water leak proof treatment complete all as specified and as directed.
S&F in repair gun metal globe or gate valves 25mm bore of pipe, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S&F CI pipe 75mm dia in any length with or without ears with cement joints and fixed on walls Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out from walls, if required 75mm bore complete all as specified and as directed.
-Ditto- all as item above but 100mm dia complete all as specified and as directed.
S&F in repair CI bend 75mm dia (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and as directed.
S&F in repair CI bend 100mm dia (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and as directed.
Dismantling of RCC posts or struts (wood, steel or R.C.C.) of any section including taking out embedded portion and making good of disturbed ground (posts embedded in Concrete, brick work, masonry, etc.) etc complete all as specified and as directed.
Dismantling chain link fencing, wire mesh of any type fixed in any situation including flat iron MS round bars, nuts & bolts etc complete all as specified and as directed.
Excavation in post holes each n.exc. 0.50 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm watering and removing surplus soil to a distance n. exc 50m and making good surface in hard/dense soil etc complete all as specified and as directed.
M&L for providing reinforced cement concrete type B-1, 1:2:4 (20mm graded aggregate in precast posts for fencing, average sectional area exc 100 sqcm and n.exc. 250 sqcm, with or witlhout chamfered angles and flat splayed rounded or mitred tops complete all as specified and as directed.
S&F in repair, galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, incl securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and as directed. ( each line wire to be measured).
S&F mild steel nuts and bolts of 12mm dia 150mm long machine made with hexagonal or sqare heads at one end and screwed the other and fitted with one washer and one haxagonal nut etc complete all as specified and as directed.
S&F mild steel flats 40x6mm including cutting and drilling for securing chain link to fencing posts etc complete all as specified and as directed.
Supply only galvanised chain link fencing of size 100mm x100mm mesh made out of 10 gauge mild steel ganvanised wire complete all as specified and as directed.
Fixing only chain link fencing including line wires any mesh size and type to any type of standards rails, straining bolts, etc including provision of binding wire etc complete all as specified and as directed.
M&L 10mm dia mild steel round bars as straining bars to secure chain link fencing with fencing posts incl running welding to the ends of bars with overlapping not less than 10cm etc conforming to Fe-410-W(Gde E-250 quality A) complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coat synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L 5 mm thick rendering in CM 1:3 on concrete surfaces as on ceiling/chajjas at any height and finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
M&L applying two coats of white wash including preparation of new plastered surfaces of ceiling complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement based paint (any tint) over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of Exterior emulsion paint Apex (any tint) over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coat oil bound distemper over a coat of chalk whiting primer complete all as specified and as directed.
S & F 6mm thick corrugated or semicorrugated asbestos cement sheets fixed with "L" type or "J" type hooks in roofs, walls and ridge of any description and at any height Including dismantling of Asbestos cement (Corrugated , Semi corrugated etc ) sheet in roof covering complete all as specified and as directed.
S&F prepainted galvalume sheets having pitch 190mm, depth 29mm and thickness not less than 0.50mm (Galvalume base-PPGL trapezoidal profile sheets) fixed with aluminium self stapping screws of size 50/75mm and aluminium washer of suitable size in roof covering including ridge all as specified.(Over lap shall be as specified by manufacturer) including dismantling of Asbestos cement (Corrugated , Semi corrugated etc ) sheet or any other in roof covering complete all as specified and as directed.
M&L for preparation of old undecorated surfaces of walls by complete removal of existing treatment and applying two coats of oil bound distemper over a coat of chalk whiting primer complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint any tint complete all as specified and as directed.
M & L preparation of old decorated surfaces of walls by complete removal of existing treatement and applying two coats of cement based paint (any tint) over a coat of chalk whiting primer complete all as specified and directed.
M&L preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint any tint complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks of capacity 500 litres (cylindrical vertical with closed top) hoisted and fixed in position including Dismantling water tanks old unserviceable water tank of cap 500 litres complete all as specified in SSR Part I and as directed.
Taking down shutter exc. 1.00 Sqm but n.exc. 2.00 Sqm each and removing from site complete all as directed by Engineer-in-Charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitabe PVC sheet beading, and joined together with solvent cement, supplying & fixinig in the frame at site as per specifiction & drawing.
S&F butt hinges medium weight cold rolled mild steel 100mm long complete all as directed by Engineer-in-Charge.
S&F aluminium anodised barrel tower bolts of extruded section 100mm long complete all as directed by Engineer-in-Charge.
S&F aluminium alloy anodised handle, cast type 100mm long complete all as directed by Engineer-in-Charge.
S.R.M.K Enterprises
MANIYA CONSTRUCTION CO.
MAHESH DADAJI BACHHAV
Shri Sant Cosntruction
M/S JAYCONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .