Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹5.6 L
EMD Value
₹11,203
Closing Date
16 Oct 2026, 11:30 am4d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer, Electrical Division, M.C., Chd
Executive Engineer, Electrical Division, M.C., Chd
Providing and fixing of new lights in place of old, missing, non led garden street light in sector 15,16,17 and 24 (Ward No.12) Chandigarh
2026_MCC_96033_1
201/E/MCC/2026
Open Tender
Electrical Works
Percentage
90 days
Providing and fixing of new lights in place of old
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹11,203
9 Oct 2026
9 Oct 2026
16 Oct 2026
9 Oct 2026
16 Oct 2026
9 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminium armoured cable loose in trench/pipe:-
Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminum conductor armoured cable (PVC Sheathed) of make Sunhome/ Finolex/ Cirtina/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1/2022 MV CB PIP-25 Part-II (External). The cable should be terminated existing/ new cc collar with proper thimbling. The job included all Connections, Commissioning and testing of phase supply Material Testing report to be submitted and material to be supplied at site after confirmation from Engineer-in-charge. The specification of the cable as below:-
i) Conductor – Aluminum
ii) Core – 4
iii) Working Voltage – 1100 V
iv) Nominal Cross Section – 16mm2 v) Minimum No. of Wire – 7/6
vi) Insulation Thickness – 1.0mm (Nominal)
vii) Inner Sheath Minimum Thickness – 0.3mm
viii) Outer Sheath Minimum Thickness – 1.40mm
ix) Nominal size of Armoured Wire/Strip – 4x0.8mm
x) Approximate O.D. – 22mm
Maximum d.c. Resistance at 20 Deg. C – 1.91 ohm/km
The work shall be executed to the entire satisfaction of Engineer-in-Charge. | 800 | Mtrs. | 238 | ₹1,90,400 |
| 2 | Supply & Laying of DWC pipe 51/63mm without hand bockey:- DSR 14.16.1 (75 cm below)
Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) Without Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930/ IS 16205 complete with fitting and cutting, jointing etc. direct in ground (depth as per the direction of Engineer in charge or upto 75 cm below ground/ road level by digging the ground or cutting the road/ paver blocks upto required level & laying of DWC pipe for laying L.T. upto 1.1 KV grade) cables etc. including excavation and refilling of digging including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work. | 350 | Mtrs. | 227 | ₹79,450 |
| 3 | Supply & Laying of DWC pipe 51/63mm with hand bockey:- DSR 14.15.1 (75 cm below) Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) With Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930/ IS 16205 complete with fitting and cutting, jointing etc.direct in ground (depth as per the direction of Engineer in charge or upto 75 cm below ground/ road level by digging the ground or cutting the road/ paver blocks upto required level & laying of DWC pipe for laying L.T. upto 1.1 KV grade) cables etc. including excavation and refilling the trench but including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work. | 100 | Mtrs. | 279 | ₹27,900 |
| 4 | Supply & Laying of flexible PVC insulated FR PVC sheathed 3 Core 1.5 mm2 Copper Cable conforming to IS - 694:2010 of make KEI/ Havell's/ Cirtina/ Finolex/ Lapp/ Polycab within the already erected 9 mtr Steel Tubular Pole and within bracket fitted on pole with the help of ladder/crane. The job include the cost of dismantling & re-erection fitting, bracket, managing traffic using proper precaution, making the required connection as started above and other petty material required to complete the job to the entire satisfaction of engineer-in-charge precautions of the work. | 450 | Mtrs. | 147 | ₹66,150 |
| 5 | S&E of Outdoor type both side with L-key lock arrangement openable M.S. Cubical Pedestal of size 1200mmx 900mm x350mm fabricated from 16 G.M.S. sheet welded on M.S. angle iron frame of size 50mmx 50mm x6mm with 4 Nos. legs of angle iron of same size each of length 600mm with M.S. sheet of size 100mm x 100mm x 6mm thick at the bottom of the legs. The front side and the back side of the pedestal should be openable with hinged door provided with Godrej type locking arrangements. A 'U' type support made from M.S. sheet of 16 G having width 75mmx 6mm be welded vertically in the inner side of the door to avoid entry of water. The door of the pedestal should be provided with rubber gasket to avoid entry of other insects etc. The top of the pedestal shall be covered with canopy made out of 16 G M.S. sheet projected outside to avoid entry of water. Four No. supporting members each of size 50mm x 6mm thick according to cubical size shall be welded for mounting switcher gear i.e. ICTPN, BBC, Timer and energy meter etc. The Pedestal shall be painted with two coats of P.O. red paint after applying one coat of red oxide. One No. The legs of the pedestal shall be embedded in the 1:2:4 C.C. mixture by digging 1' deep pit of 1' dia. The letter 'M.C.C.' in 4" size shall be written on the front door of the Pedestal. The job also included supply and erection one no. wooden plank/ board of size 1’-6’’ x 1’-6’’ and 25mm thick suitable for fixing energy mater including cost of screw, nuts and bolts in cubical pedestal complete in all respect. The pedestal will be housed on RCC foundation, Snowcem and platform of size 900mm deep (450mm underground and 450 mm above ground x 960 mm long x 410 mm wide including sufficient number of DWC pipe size of 51/63mm pieces to facility to entire the main cable and the circuit cable. The work shall be executed to the entire satisfaction of Engineer-in-Charge. | 1 | Nos. | 20,204 | ₹20,204 |
| 6 | Supply & Erection of Three Phase Aluminum Bus Bar
Supply & Erection of Three Phase Aluminum Bus Bar of size 300mmx 25mmx 5mm with L type fuse unit to be fixed on Porcelein insulators in the existing pedestal with required nuts, bolts & M.S. sheet. The fuse links should be equal to the number of outgoing circuits. The work shall be executed to the entire satisfaction of Engineer-in-Charge. | 1 | Nos. | 2,399 | ₹2,399 |
| 7 | Supply & Erection of Three Phase Automatic Timer and Contactor assembled in 22 gauge CRCA sheet enclosure duly powder coated with the following accessories (Three Phase) of Make Amsons/ L&T/ Schenider or equivalent as approved by the Engineer-in-Charge. It shall conform to latest relevant IS Code:-
1. It shall have 3 contactors of capacity 40 Amp. each of made BCH, Legrand, L&T or Siemons. The contractor should be of AC-3 duty 2 pole, 220/240 V coil Voltage.
2. It shall have Auto/Manual switch, light activated switching system with allied accessories as required. 3. It shall have kit-kat fuse unit of 40 Amp capacity. The fuse unit shall conform to latest relevant IS code for protection of timers, bakelite sheet & other components as per requirement as site. 4. It shall be housed in a powder coated 22 gauge M.S sheet cabinet for its protection. 5.The device shall be provided/fixed in the existing pedestal box in such a way so that it operates at correct time i.e. at rising/setting of Sun. The Sensor shall be included time watch to operate as required. The work shall be executed to the entire satisfaction of Engineer-in-charge. Warranty:- IT SHOULD STAND WARRANTY FOR ONE YEAR TOWARDS ANY MANUFACTURING DEFECTS. | 1 | Nos. | 16,487 | ₹16,487 |
| 8 | S&E of Mouled Case Circuit Breakers (MCCB) of rating 63 Amp with Breaking Cap 16 kA, 415 Volts.
Supply & Erection of 3 pole, 16 kA, 63 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge. | 1 | Nos. | 3,950 | ₹3,950 |
| 9 | G.I. Earth pipe electrode without salt/ Charcoal: DSR 5.2/2022 Supply and laying of earth electrode made out of ISI marked 'B' class earthing with G.I. earth pipe 3 mtr long, 40mm dia including accessories, G.I. pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom (without charcoal or coke and salt). The earth electrode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the Engineer-in-charge. | 5 | Nos. | 2,691 | ₹13,455 |
| 10 | P/F 6 SWG GI earth wire in pipe: DSR 5.12/2022 Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required. | 15 | Mtrs. | 273 | ₹4,095 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.52 MB
BOQ_118018.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .