₹20 L
EMD Value
₹20,000
Closing Date
30 Nov 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer/ PEDC/ Pudukkottai
O/o Superintending Engineer/ PEDC/ Pudukkottai, Near Old Bus Stand, TANGEDCO, Pudukkottai
Running contract for a period of one year for Gandarvakottai sub division
2022_EB_264476_1
Enq No 0446105/2022-23
Open Tender
Electrical Works
Works
30 days
GANDARVAKOTTAI SUB DIVISION
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹20,000
Yes
3 Dec 2022
16 Nov 2022
1 Dec 2022
16 Nov 2022
30 Nov 2022
16 Nov 2022
16 Nov 2022 - 30 Nov 2022
GANDARVAKOTTAI SUB-DIVISION RUNNING CONTRACT
Excavation of pole pit For pole upto 8.00m length by using JCB/Manual
Excavation of pole pit For pole above 8.00m length by using JCB/Manual
Excavation of pole pit In Hard Soil (common to all size of poles)
In rocky area (common to all size of poles) by blasting / Manual
Excavation of Stay pit of 4.5 ' to 5 ' depth using JCB / Manual
Excavation of Stay pit in Hard rock soil
Erection of RCC, REC, PSC poles upto 8.00m length by using Crane / Manual
Erection of RCC, REC, PSC poles above 8.00m length by using Crane / Manual
Erection of metal supports above 9m / RSJ / Rail Pole/Tubular Poles
Erection of stay set complete with fixing up stay wire Eye, Bow, Guy Shackle, Binding etc.
Erection of additional Stay in the same stay rod, excluding excavation of stay pit and burial of stay rod.
Erection of stay set complete in the rock area by blasting
Fixing of V cross arm 3.5 feet
Fixing of V cross arm 4.5 feet
Fixing of V cross arm 5.0 feet
Fixing of LT S phase cross arm
Fixing of LT 3 phase cross arm
Fixing of HT / LT Ti fitting
Fixing of HT PIN insulator with Pin 11 kv
Fixing of HT PIN insulator with Pin 22 kv
Fixing of HT PIN insulator with Pin 33 kv
Fixing of LT PIN insulator
Fixing of HT strain disc 11 KV
Fixing of HT strain disc 22 KV
Fixing of HT strain disc 33 KV
Fixing of Two Tapping cross arm per cut point upto 33 KV line including fixing of Discs,insulators and Jumpering etc..
Set right of all sizes of leaning poles
Fixing of shackle
Fixing of Aluminium knob
Fixing of HT LAS (3 Nos.)
Fixing of LT LAS (3 Nos.)
Fixing of Tapping Channel X Arm
Paving and stringing of conductors of sizes upto 7/2.59 mm ACSR or other equivalent conductor
Paving and stringing of conductors of above 7/2.59 mm ACSR or other equivalent conductor upto 7/3.35mm ACSR or other equivalent conductor
Paving and stringing of conductors of one run of PVC cable line of all sizes with GI wire and reel insulator.
Paving and stringing of conductors of 7/4.09mm ACSR or other equivalent conductor
Paving and stringing of conductors of 7/4.72 mm Dog Conductor or other equivalent conductor
Releasing and reerection (resagging) of one run of all sizes of conductor
Erection of Distribution Transformer structure complete as per TNEB standard including painting, feeders arrangrment, colour washing of RCC poles etc.. Fixing of poles type to be unit HT / LT LAS and jumpering 3 Nos Earth pits with earth trough except erection of Distribution Transformer.
Erection of Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa.(i) Upto 25 KVA Distribution transformer / Metering set.
Erection of Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa.(ii) Above 25 KVA to 100 KVA
Erection of Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa.(iii) Above 100 KVA to 250 KVA
Erection of Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa.(iv) 500 KVA and above
Erection of Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa.(V) Failed DT replacement below 100 KVA
Erection of Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa.(vi) Failed DT replacement 100 KVA and above
Erection of 11 KV single pole Structure including erection of DT complete without centre support
Erection of 11 KV Single Pole structure including erection of DT complete with centre support
(i) With 11 KV AB switch using all types of poles of size 9.14 m and above length
(i) With 22 / 33 KV AB switch using all types of poles of size 9.14 m and above length
Erection of single pole DP with complete and with single earth
Concreting with 1:4:8 mix using 40 mm Jelly including curing(Material + labour) (i) Mass concreting of poles
Concreting with 1:4:8 mix using 40 mm Jelly including curing(Material + labour) (ii) Sleeve concreting
Concreting with 1:4:8 mix using 40 mm Jelly including curing(Material + labour) (iii) Stay concreting
(i) Earthing of poles with GI wires 4 or 6 SWG by coil earthing
(ii) Provision of spike including earthing arrangement
(iii) Pipie earthing including excavation of earth pit and fixing earth pipe 3 m length
(iv) Replacing the corroded earth pipes of transformer structure and replacing the earth wire completely with aluminium lugs for termination
(v) Replacement of corroded earth pipe
Loading or unloading of Distribution Transformer (i) Upto 100 KVA
Loading or unloading of Distribution Transformer (ii) Above 100 KVA and upto 500 KVA
Loading or unloading of Distribution Transformer (iii) Metering set of all ratios
Loading or unloading of various sizes of poles (i) REC, RCC, PSC pole upto 8.00 m length
Loading or unloading of various sizes of poles (ii) All REC, RCC pole above 8.00 m length
Loading or unloading of various sizes of poles (iii) Metal poles all sizes
Loading of Conductor
Unloading of Conductor
Loading / Unloading of Iron & Steel
Loading / Unloading of Oil
Loading / Unloading of line materials
Loading / Unloading of 11 KV strain disc
Loading / Unloading of LT Pin insulator shackle, guy shackle, LT Pin, Metal parts, HT pin etc.,
Loading / Unloading of meters (i) Single Phase Meter
Loading / Unloading of meters (ii) Three Phase Meter
Provision of guarding with two numbers earth pits excluding stay set erection -Provision of guarding with two numbers earth pits excluding stay set erection (i) Flat guarding with earth pit
Provision of guarding with two numbers earth pits excluding stay set erection- Provision of guarding with two numbers earth pits excluding stay set erection (ii) Split neutral
Transportation of all types and sizes of poles and other associated materials from Road side to pole pit and vice versa upto 0.50 KM
Transportation of all type of poles by bullock cart or other vehicle (for all sizes of poles including loading and unloading)
(i) For a lead upto 5 KM
(ii) Above 5 KM of lead of every KM
Transport of Metal pole of all sizes by head loads in hill areas from road side to pole pit location
(i) Upto 1 KM
(ii) Above 1 KM per each KM
Transporting of conductors of all sizes from road side to pit locations upto one KM of Conductor
(i) Transporting of Distribution Transformer / Line materials from stores to office / site upto 10 KM distance by engaging 1 Ton capacity Minidor (Lorry)
(ii) Above 10 KM
Dismantling of RCC, REC, PSC & metal pole of all sizes including the closing of the pit
For breaking the mass concrete of all supports
Dismantling of stay set complete
Dismantling of stay set complete (i) including stay rod
Dismantling of stay set complete (ii) Without stay rod
Dismantling of conductor of upto 7/3.35 including transporting the conductors to the nearest road side and stocking in coils
Dismantling of conductor of above 7/3.35 including transporting the conductors to the nearest road side and stocking in coils
Dismantling of Transformer structure materials complete set and transporting the same from the location to the road side
Dismantling of Cross arm clamps TI fitting hardwares, insulators etc.,
Painting of distribution transformer of all capacities (paint to be supplied by the Board) including cleaning of DT
Numbering of poles including base painting and with cost of paint
Painting of iron poles up to 36 ft length with double coats including cost of paint
Painting of iron poles up to 40 ft 200/100 length with double coats including cost of paint
Painting of Cement poles by Distember coating including cost of distember
Painting of structure materials distribution transformers with aluminium paint of structure poles and writing of transformer details (Items 1 to 6 brush to be owned by the contractor)(Paint to be supplied by Department)
Service Connection Details painting
Hut service connection works (All labour charges except making connection to the over head line)
Fixing of one set of street light fixture with clamp and fitting of all sizes including cable jumpering and including transportation
Dismantling of one set of street light fixture with clamp and fitting of all types
Erection of MV/Sodium Vapour Lamps including wiring and fixing at street light location including transportation
Replacing the worn out service connection cables
Manufacturing / Altering of Clamps
Drilling of holes in the structure materials clamps etc.,
AB switch or open type side arm stud, cutting and drilling holes
Manufacturing of earth pipe clamps for structure including of drilling holes and welding and clamp with earth pipe
Numbering of Poles including cost of paint
Painting of RCC poles
Removing weed in substation yard / office premises
Bush Clearance out side substation yard / office premises (light)
Jungle clearance such as kattu karuvai in the various area without uprooting
Jungle clearance such as kattu karuvai in the various area with uprooting
Clearing of tree braches of coconut trees
Clearing of tree braches of Neem, Tamarin, Country etc
Leveling of Ground using Bul Dozer
Clearing of Branches / Trees with JCB
Fencing of Distribution Transformer Structure at Road side- Fabrication and Erection.(including all materials)
Cleaning of 110 KV Breakers including C.Ts and allied maintenance work
Cleaning of 110 KV LAS
Cleaning of 110 KV A.B.Switch and applied petrolium gelly (including Consumables and Petrolium gelly)
Cleaning of 33/22/11 KV Breakers and C.Ts and allied maintenance works
Cleaning and checking of 110 KV Bus Insulators
Cleaning and checking of 11/ 22 / 33 KV Bus Insulators
Cleaning and checking of 11/22/33 KV A.B. Switches including tightining of bolt & nuts and applied petrolium gelly and rectifying defects (excluding consumables Bolt and Nuts and Petrolium gelly)
Replacement of clamps in substation including jumpering
Tightening of clamps in all 110 / 33 / 22 /11 KV Buses
Checking of earth pit and tightening, Replacing of Bolts and Nuts
Cleaning of Cable Duct
Excavation of cable trench 0.6 meters width and 1.2 meters depth including cost of providing sign boards, danger lights, indication arrangements lead, lift, labour and tools and plants etc., - Normal Road
Excavation of cable trench 0.6 meters width and 1.2 meters depth including cost of providing sign boards, danger lights, indication arrangements lead, lift, labour and tools and plants etc., - Tar Road
Excavation of cable trench 0.6 meters width and 1.2 meters depth including cost of providing sign boards, danger lights, indication arrangements lead, lift, labour and tools and plants etc.,-Concrete Road
Loading and unloading of HT Cable including coiling and recoiling
Transporting of 11 KV HT cable from departmental stores to work spot by engaging private vehicle upto 5 Km
Transporting of 11 KV HT cable from departmental stores to work spot by engaging private vehicle above 5 Km
Laying of 11KV 3 X 300 sq mm XLPE cable
Laying of 11KV 3 X 120 sq mm XLPE cable
Covering HT cable by cement "V" trough after covering the cable with good loose earth including loading, unloading and transport from stores to site and letter painting of feeding details & Cable size on the trough
Refilling with excavated earth layers well consolidated as per std specification including all materials, lead, lift etc., complete.
Transport back any balance cable, empty drums and other materials if any by engaging private vehicle including recoiling, coiling and loading and unloading at both sides from workspot to departmental stores (minimum 2 drums) upto 5 Km
Transport back any balance cable, empty drums and other materials if any by engaging private vehicle including recoiling, coiling and loading and unloading at both sides from workspot to departmental stores (minimum 2 drums) above 5 Km
Laying of HT UG cable using Trenchless Method with Pipes
Laying of HT UG cable using Trenchless Method without Pipes
Loading and unloading of LT Cable including coiling and recoiling
Transporting of 11 KV LT cable from departmental stores to work spot by engaging private vehicle upto 5 Km
Transporting of 11 KV LT cable from departmental stores to work spot by engaging private vehicle above 5 Km
Excavation of cable trench size 0.45m x0.75 m including cost of providing sign boards, danger lights, indication arrangements, lead, lift, labour and T&P etc. - Normal Road
Excavation of cable trench size 0.45m x0.75 m including cost of providing sign boards, danger lights, indication arrangements, lead, lift, labour and T&P etc. -Tar Road
Excavation of cable trench size 0.45m x0.75 m including cost of providing sign boards, danger lights, indication arrangements, lead, lift, labour and T&P etc. -Concrete Road
Laying of LT 4 x 240 sq.mm cable
Laying of LT 4 X 120 sq.mm cable
Laying of LT 4 X 25 sq.mm cable
Laying of LT 2 X 16 sq.mm cable
Refilling with excavated earth layers as per std specification including all materials, lead, lift etc., complete.
Erection of 4 / 6 Way pillar box - 3 Feet Height using concrete only - including excavation of foundation pits as per standard specification 2 Nos pillar concrete walls, coping and earthing including cost of all materials, el. works, transportation, lead, lift etc.,
Erection of Mini pillar box - 3 Feet Height using concrete only - including excavation of foundation pits as per standard specification 2 Nos pillar concrete walls, coping and earthing including cost of all materials, el. works, transportation, lead, lift etc.,
Cleaning&painting with Aluminium paint 2 coats & numbering with fdr details with materials - 8 Way Pillar Box
Cleaning&painting with Aluminium paint 2 coats & numbering with fdr details without materials - 8 Way Pillar Box
Cleaning&painting with Aluminium paint 2 coats & numbering with fdr details with materials - 6 Way Pillar Box
Cleaning&painting with Aluminium paint 2 coats & numbering with fdr details without materials - 6 Way Pillar Box
Cleaning&painting with Aluminium paint 2 coats & numbering with fdr details with materials - 4 Way Pillar Box
Cleaning&painting with Aluminium paint 2 coats & numbering with fdr details without materials - 4 Way Pillar Box
Cleaning&painting with Aluminium paint 2 coats & numbering with fdr details with materials - Mini Pillar Box
Cleaning&painting with Aluminium paint 2 coats & numbering with fdr details without materials - Mini Pillar Box
Dismantling of old 5 / 6 / 8 Way pillar box including associated accessories, loading on the vehicle, transporting, unloading at stores and stacking.
Dismantling of old Mini pillar box including associated accessories, loading on the vehicle, transporting, unloading at stores and stacking.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .