| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | ₹32.6 L Quoted ₹33.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹35.3 L+₹1.5 L (4.56%)Rejected-AOC | ₹35.3 L+₹1.5 L (4.56%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹41.0 L+₹7.2 L (21.4%)Rejected-AOC | ₹41.0 L+₹7.2 L (21.4%) | L3 | Rejected-AOC Rejected |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
19 Mar 2022, 6:00 pmClosed
GE (AF) Srianagar
Garrison Engineer (AF) Srinagar Air Force Station Srinagar-190007
REPAIR / REPLACEMENT / MAINTENANCE OF VARIOUS CAPACITY LT SWITCHGEAR I.E. MCCBS, ACBS, CONTACTOR, APFC PANEL, EARTHING PITS, LIGHTING ARRESTER, ETC AND OTHER MISC CONNECTED WORK UNDER GE(AF) SRINAGAR.
2022_MES_509288_1
GE(AF)SGR- 26 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SRINAGAR
All as per Tender Documents
9 documents required · 9 mandatory
₹500
Yes
GE (AF) SRINAGAR
₹90,000
Yes
28 Jun 2022
19 Feb 2022
21 Mar 2022
19 Feb 2022
19 Mar 2022
5 Mar 2022
Amount
Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, Feeder pillar board kiosk type, confirming to IS 5039 with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply, mounted on and including MS angle section 40 x 40 x 5 mm frame with front openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated, including taking down old Feeder pillar board complete all as specified and directed & Consisting of the following switchgear:-
Solid aluminium bus bar 300 Amp for 3 phase , 150 Amp for neutral - 01 set
MCCB 4 Pole, 200 Amps, rupturing capacity 25 kA, 440 Volts, adjustable type - 01 Nos as incoming
MCCB 3 Pole , 63 Amps, rupturing capacity 16 kA, 440 Volts, adjustable type - 02 Nos as outgoing
MCCB 3 Pole , 25 Amps, rupturing capacity 10 kA, 440 Volts, adjustable type - 02 Nos as outgoing
MCB SPN 10 A mps, rupturing capacity 10 KA, 240 Volts - 05 Nos as outgoing
Indicator Lamp 22.5 mm dia LED type 240 Volts AC to show three phase availability- 01 set
Note :- Quoted rates shall be deemed to include for grouting / fixing of feeder pillar board over & including brick masonry platform of hight 450 mm above GL, with old size brick set in CM 1:4, PCC 1:4:8 type D2 in foundation, 15 mm rendering in CM 1:6 on exposed surfaces, 100 mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting legs of panel.
Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, Feeder pillar board kiosk type, confirming to IS 5039 with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply, mounted on and including MS angle section 40 x 40 x 5 mm frame with front openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated, including taking down old Feeder pillar board complete all as specified and directed & Consisting of the following switchgear:-
Solid aluminium bus bar 300 Amp for 3 phase , 150 Amp for neutral - 01 set
MCCB 4 Pole, 200 Amps, rupturing capacity 25 kA, 440 Volts, adjustable type - 01 Nos as incoming
MCCB 3 Pole, 63 Amps, rupturing capacity 16 kA, 440 Volts, adjustable type - 01 No as outgoing
MCCB 3 Pole , 40 Amps, rupturing capacity 16 kA, 440 Volts, adjustable type - 02 No as outgoing
MCCB 3 Pole, 25 Amps, rupturing capacity 16 kA, 440 Volts, adjustable type - 01 No as outgoing
Indicator Lamp 22.5 mm dia LED type 240 Volts AC to show three phase availability- 01 set
Note :- Quoted rates shall be deemed to include for grouting / fixing of feeder pillar board over & including brick masonry platform of hight 450 mm above GL, with old size brick set in CM 1:4, PCC 1:4:8 type D2 in foundation, 15 mm rendering in CM 1:6 on exposed surfaces, 100 mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting legs of panel.
Supply and installation, testing, commissioning, factory made, bus bar chamber of size 1000 mm x 900 mm x 600 mm size, CPRI approved, outdoor type, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet, 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 50 x 50 x 5 mm frame with front and back openable, with provision of locking arrangement dust & vermin proof , gasket, TPN busbar of size 400 amps for phase, 200 amps for neutral, insulated with colour coated heat shrinkable sleeves, mounted on proper insulator, provision for 08 Nos LT connection, with gland, welding hinges, dust & vermin proof, overall powder coated, including taking down old busbar chamber complete all as specified and directed.
Note :- Quoted rates shall be deemed to include for grouting / fixing of feeder pillar board over & including brick masonry platform of hight 450 mm GL, with old size brick set in CM 1:4, with PCC 1:4:8 type D2 in foundation, 15 mm rendering in CM 1:6 on exposed surfaces, 100 mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting legs of panel.
Supply and installation, testing, commissioning, factory made, bus bar chamber of size 900 mm x 750 mm x 600 mm size, CPRI approved, outdoor type, confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet, 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 50 x 50 x 5 mm frame with front and back openable, with provision of locking arrangement dust & vermin proof , gasket, TPN busbar of size 200 amps for phase, 100 amps for neutral, insulated with colour coated heat shrinkable sleeves, mounted on proper insulator, provision for 08 Nos LT connection, with gland, welding hinges, dust & vermin proof, overall powder coated, including taking down old busbar chamber complete all as specified and directed.
Note :- Quoted rates shall be deemed to include for grouting / fixing of feeder pillar board over & including brick masonry platform of hight 450 mm GL, with old size brick set in CM 1:4, with PCC 1:4:8 type D2 in foundation, 15 mm rendering in CM 1:6 on exposed surfaces, 100 mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in padding on top and grouting legs of panel.
S&F in repair MCCB 4 pole, 63 amps with breaking capacity 16 KA, 415 volts, fixed in existing panel & connecting complete all as specified and directed.
S&F in repair MCCB 4 pole, 100 amps with breaking capacity 16 KA, 415 volts, fixed in existing panel & connecting complete all as specified and directed.
S&F in repair MCCB 4 pole, 160 amps with breaking capacity 25 KA, 415 volts, microprocessor release type, fixed in existing panel & connecting complete all as specified and directed.
S&F in repair MCCB 4 pole, 200 amps with breaking capacity 25 KA, 415 volts, microprocessor release type, fixed in existing panel & connecting complete all as specified and directed.
S&F in repair MCCB 4 pole, 250 amps with breaking capacity 25 KA, 415 volts, microprocessor release type, fixed in existing panel & connecting complete all as specified and directed.
S&F in repair MCCB 4 pole, 400 amps with breaking capacity 25 KA, 415 volts, microprocessor release type, fixed in existing panel & connecting complete all as specified and directed.
Supply and installation, connecting, testing & commissioning Air Circuit Breaker (ACB) 4 pole, 630 amps, 415 volts, manual drawout type, microprocessor release type, fixed in existing panel & connecting complete all as specified and directed.
Supply and installation, connecting, testing & commissioning Air Circuit Breaker (ACB) 4 pole, 800 amps, 415 volts, manual drawout type, microprocessor release type, fixed in existing panel & connecting complete all as specified and directed.
S&F in repair 4 Pole Power Contactor Range: 40 A Conforms to IS / IEC 60947-4-1 Snap fit construction Completely Shield for dusty atmosphere Low VA burden Coils complete all as specified and directed by Engineer in Charge. Make:- Havells cat Part No : IHPHC040100 or equivalent cat No of make mention in Appx A.
S&F in repair 4 Pole Power Contactor Range: 60 A Conforms to IS / IEC 60947-4-1 Snap fit construction Completely Shield for dusty atmosphere Low VA burden Coils complete all as specified and directed by Engineer in Charge. Make:- Havells cat Part No : IHPHC060200 or equivalent cat No of make mention in Appx A.
S&F in repair 3 Pole Power Contactor AC-1 Duty Rating at 415 V, 50 Hz, 160 A, Conforms to IS / IEC 60947-4-1 Snap fit construction completely Shield for dusty atmosphere Low VA burden Coils complete all as specified and directed by Engineer in Charge. Make:- Havells cat Part No : IHPHA115500* or equivalent cat No of make mention in Appx A.
S&F in repair 3 Pole Power Contactor AC-1 Duty Rating at 415 V, 50 Hz, 210 A, Conforms to IS / IEC 60947-4-1 Snap fit construction completely Shield for dusty atmosphere Low VA burden Coils complete all as specified and directed by Engineer in Charge. Make:- Havells cat Part No : IHPHA150500* or equivalent cat No of make mention in Appx A.
S&F in repair 3 Pole Power Contactor AC-1 Duty Rating at 415 V, 50 Hz, 315 A, Conforms to IS / IEC 60947-4-1 Snap fit construction completely Shield for dusty atmosphere Low VA burden Coils complete all as specified and directed by Engineer in Charge. Make:- Havells cat Part No : IHPHA225600* or equivalent cat No of make mention in Appx A.
S&F in repair 3 Pole Power Contactor AC-1 Duty Rating at 415 V, 50 Hz, 400 A, Conforms to IS / IEC 60947-4-1 Snap fit construction completely Shield for dusty atmosphere Low VA burden Coils complete all as specified and directed by Engineer in Charge. Make:- Havells cat Part No : IHPHA300700* or equivalent cat No of make mention in Appx A.
M&L for repairing of APFC Panel of capacity 125 kVAR by opening , dismantling and taking out from existing position after the disconnection of power supply, carried out following repair work (a) Replacement of 5-stage of APFC system and wiring (b) Re-control wiring for capacitor panel 1.5 Sqmm PVC copper cable complete (c) Replacement of capacitor as fixed in existing capacity-06 Nos (d) Replacement of auxiliary contractor as fixed in existing capacity-03 nos (e) Replacement of 440 volt meter of 0 to 500 volt , 3 phase voltmeter as fixed in existing capacity
(f) Replacement of Amp meter of 0 to 500 Amps , 3 phase as fixed in existing capacity (g) Replacement of GI strip for earthing as fixed in existing size-10 RM (h) Replacement of copper wire 6.0 Sqmm for earthing and interconnection to system strip will be protected by PVC sleeves complete (j) Replacement of main control switch as fixed in existing capacity-01 Nos (k) Replacement of relay fixed in existing capacity-06 nos (l) Replacement of main control digital meter as fixed in existing capacity. After the completion of repair works assembling of panel, fixed in position, reconnecting at site with electric supply, testing and commissioning of APFC panel all as specified and directed by Engr-in-charge.
M&L for repairing of APFC Panel of capacity 150 kVAR by opening , dismantling and taking out from existing position after the disconnection of power supply, carried out following repair work (a) Replacement of 7 stage of APFC system and wiring (b) Re-control wiring for capacitor panel 1.5 Sqmm PVC copper cable complete (c) Replacement of capacitor as fixed in existing capacity-06 Nos (d) Replacement of auxiliary contractor as fixed in existing capacity-03 nos (e) Replacement of 440 volt meter of 0 to 500 volt , 3 phase voltmeter as fixed in existing capacity
(f) Replacement of Amp meter of 0 to 500 Amps , 3 phase as fixed in existing capacity (g) Replacement of GI strip for earthing as fixed in existing size-10 RM (h) Replacement of copper wire 6.0 Sqmm for earthing and interconnection to system strip will be protected by PVC sleeves complete (j) Replacement of main control switch as fixed in existing capacity-01 Nos (k) Replacement of relay fixed in existing capacity-06 nos (l) Replacement of main control digital meter as fixed in existing capacity. After the completion of repair works assembling of panel, fixed in position, reconnecting at site with electric supply, testing and commissioning of APFC panel all as specified and directed by Engr-in-charge.
M&L for repairing of APFC Panel of capacity 250 kVAR, by opening , dismantling and taking out from existing position after the disconnection of power supply, carried out following repair work (a) Replacement of 7 stage of APFC system and wiring (b) Re-control wiring for capacitor panel 1.5 Sqmm PVC copper cable complete (c) Replacement of capacitor as fixed in existing capacity-06 Nos (d) Replacement of auxiliary contractor as fixed in existing capacity-03 nos (e) Replacement of 440 volt meter of 0 to 500 volt , 3 phase voltmeter as fixed in existing capacity
(f) Replacement of Amp meter of 0 to 500 Amps , 3 phase as fixed in existing capacity (g) Replacement of GI strip for earthing as fixed in existing size-10 RM (h) Replacement of copper wire 6.0 Sqmm for earthing and interconnection to system strip will be protected by PVC sleeves complete (j) Replacement of main control switch as fixed in existing capacity-01 Nos (k) Replacement of relay fixed in existing capacity-06 nos (l) Replacement of main control digital meter as fixed in existing capacity. After the completion of repair works assembling of panel, fixed in position, reconnecting at site with electric supply, testing and commissioning of APFC panel all as specified and directed by Engr-in-charge.
S&F in repair Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and all as directed.
S&F in repair cable jointing kit for 11 KV (Earthed) grade cable for indoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and all as directed.
S&F in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and all as directed.
S&F in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and all as directed.
S&F in repair cable jointing kit for 11 KV (Earthed) grade cable for straight through, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and all as directed.
S&F in repair cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and all as directed.
M&L for cleaning of surrounding area of E&M installation around the bldg , transformer, GOD LT panel by grass cutting manually or mechanically (Bush cutter) as per requirement basis and trimming as directed by Engr-in-Charge, including taking out all shrubs, saplings with bushes and any type of vegetation and removing from site, complete all as specified and directed.
Supply, installation and testing Lightening Arrestor expulsion type for outdoor use complete with all fittings transmission class discharge capacity 65 kilo Amps suitable for 11000 V including bracket, clamps, nuts and washers and connecting to earth wire and taking down old Lightening Arrestor complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches in any type of soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for foundation poles, stays, laying of cables etc for shaft, wells, cesspits, manholes, peir holes, etc or not exc. 10 Sqm on plan and getting out, complete all as specified and directed by Engr-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick, using excavated soil complete all as specified and directed by Engr-in-Charge.
Removing excavated soil to a distance not exc. 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
Supply and Laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks complete all as specified and directed by Engineer-in-Charge.
Laying Only of bricks retrieved from items No. 39 to 43 here-in-before, laid flat for cable protection width equal to the length of bricks complete all as specified and directed by Engineer-in-Charge.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engr-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
M&L for cutting of existing road surfaces up 100 mm deep & 300 mm wide and making good disturbed portion with 100 mm thick plain cement concrete 1:2:4 type B-1 (using 40mm graded crushed stone aggregate) complete all as specified and directed by Engineer-in-Charge.
S&F in repair 50 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable complete all as directed.
S&F in repair 80 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable complete all as directed.
Taking out carefully unserviceable LT under ground cable of size 10 Sqmm to 16 Sqmm, any core from trenches / Pipes including taking out bricks cover, complete all as specified and as directed by Engineer-in-Charge. Note:- Serviceable Bricks obtained shall be cleaned and stacked properly for reuse
All as per Item No 39 above but cable of size 25 Sqmm to 35 Sqmm, 3.5 core.
All as per Item No 39 above but cable of size 50 Sqmm to 70 Sqmm, 3.5 core.
All as per Item No 39 above but cable of size 95 Sqmm 3.5 core.
All as per Item No 39 above but cable of size 120 Sqmm to 150, 3.5 core.
Laying only XLPE insulated, PVC inner sheathed, armored, LT underground cable of size 10 Sqmm to 16 Sqmm of any core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed. Note:- (i) Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule. (ii) LT cable will Be issued under Sch B free for laying.
All as per Item No 44 above but cable of size 25 Sqmm to 35 Sqmm, 3.5 core.
All as per Item No 44 above but cable of size 50 Sqmm to 70 Sqmm, 3.5 core.
All as per Item No 44 above but cable of size 95 Sqmm 3.5 core.
All as per Item No 44 above but cable of size 120 Sqmm to 150, 3.5 core.
Taking down unserviceable LED light fitting of capacity 30 / 45 Watt from Pole / wall or any other location, any height, any situation, and replacement of electronic driver with new driver of same capacity, tightening the loose connection and made item functional, re-fixing / re-hanging the fitting in existing location or other location (as directed) and testing complete all as specified and directed by Engineer-in-Charge. Note:- Necessary T & P like ladder / Boom Vehicle, tools etc as required for taking down & fixing of light shall be provided by contractor without any extra cost of department.
All as per item No 49 above but replacement of electronic driver suitable for LED light fitting of 50 / 60 Watt.
All as per item No 49 above but replacement of electronic driver suitable for LED light fitting of 100 Watt.
All as per item No 49 above but replacement of electronic driver suitable for LED light fitting of 150 Watt.
S&F in repairs LED street Light fitting 100 Watt, system efficiency not less than 110 lumen / watt, IP66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete.
S&F in repairs LED flood Light fitting 100 Watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete.
S&F in repairs LED flood Light fitting 150 Watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, complete.
M&L for preparation of old painted steel surface of LT feeder pillar Box, 440 Volts, 3 phase of any size / location and applying two coats of synthetic enamel paint complete all as specified and directed Engineer-in-Charge.
M&L for Sub main wiring for connecting street light fitting from junction box with two single core, PVC insulated, (ISI marked) , unsheathed, 1100 volts grade, 2.5 Sqmm multistranded copper conductor cable drawn into and including suitable size PVC conduit 20 mm dia ISI marked medium grade with all accessories and including one single core, 2.5 Sqmm PVC insulated multistranded unsheathed 1100 volts grade copper conductor cable as earth wire including taking down old pipe & cable complete all as directed & specified. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment.
Supply, installation testing & commissioning street light control box, factory made, weather and vermin proof having size 200 x 250 x 80 mm made out of 2.00 mm thick CRCA sheet, comprising of MCB SP 10A, C curve 10 KA breaking capacity 01 No's, 16 Amp 230 volt rated aluminium bus bar with mounting rail fixed on porcelain insulator, making holes on strips for connecting cables and fixing of bus bar chamber on street light pole with and including MS clamp of size 25 x 5 mm including nut, bolts washers duly painted with 2 coats of enamel paint over a coat of red oxide primer including taking down old box , all as specified and directed.
Supply and fix in repair LED, post top lantern, 40 Watt, 230 volts AC, out door type, with decorative post 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp fixed over existing pole complete Make;- Crompton Cat No LPTO-40-CDL or equivalent cat No of make mention in Appx A.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Note:- Quoted rates shall be deemed to include for earth wire with protection pipe up to 7.5 M length.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip of size 25 x 4 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Note:- Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length.
Material and labour for renewal of earthing complete with copper earth plate electrode of size 60mm x 600mm x 3mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to copper earth strip of size 20 x 3 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Note:- Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length.
M&L for preparation of old painted surface of steel tubular poles height approximately 7 to 7.5 meter above GL including cross arms and bracings and applying two coat aluminium paint and rewriting pole number with synthetic enamel paint complete all as specified and directed.
Deployment of manpower / tools / machinery / plant for Dehydration / filtration of transformer oil of transformers, etc of various capacities installed at different locations by disconnecting plants electrically for recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength not less than 50 KV when measured at 2.5 mm gap for one minute complete all as specified and as directed by Engr-in-Charge.
Note- Quoted rates shall be deem to include for following :- (i) Oil for each transformer shall be tested after filtration and test result will be recorded before & after filtration of oil and signed by Engineer-in-Charge & contractor. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete. (iii) New transformer oil as required shall be measured and paid separately under respective item.
Supply & filling Power Transformer Oil for toping up the level of oil having dielectric strength 50 KV at 4 mm gap confirming to IS-335 complete all as specified and directed by Engineer-in-Charge.
Note:- Transformer oil shall be supplied in sealed Containers. Make :- M&I MATERIAL (MIDEL) POWER LINK, POWER OIL, SAVITA
Supply and fix in repair stay assembly for LT pole complete with accessories as shown in Electrical Plate No 1 (Dia of stay rod 16 mm) complete all as specified and directed by Engr-in-charge.
M&L for plain cement concrete 1:4:8, type D- 2, (using 40 mm graded stone aggregate) as in foundation complete all as specified and directed by Engineer-in-Charge
S&F in repair street light control panel, for 3 phase supply, frame size -1, max load-6 kw, comprising digital 24 hours timer, contactor three pole 32 A , MCB three pole with neutral 40 A, fixed in position, including testing & commissioning complete all as specified and directed by Engineer-in-Charge. Make:- Havells cat Part No : IHXTS03060 or equivalent cat No of make mention in Appx A
S&F in repair street light control panel, for 3 phase supply, frame size -2, max load-12 kw, comprising digital 24 hours timer, contactor three pole 65 A , MCB three pole with neutral 63 A, fixed in position, including testing & commissioning complete all as specified and directed by Engineer-in-Charge. Make:- Havells cat Part No :IHXTS09120 or equivalent cat No of make mention in Appx A
Supply and fixing in repair GI Bracket made of 40 mm dia GI pipe medium grade 1.5 metre long, bend to shape for street light for steel / RCC pole as per site requirement including MS clamp with nut, bolt, washers complete all as specified and directed by Engineer-in-Charge
S&F in repair PVC separator suitable for 1100 V, ACSR Conductor over head line complete all as specified and directed by Engineer-in-Charge.
Deployment of manpower / tools etc for maintenance of gang operated air break isolators switch out door type 9 / 12 insulators double stack, triple pole, rotating type double break per pole for 11000 volts, 3 phase, 50 Hz, AC supply system having 200 / 400 Amps capacity by oiling, greasing, adjustment of lever and making the same smooth functional complete all as specified. complete all as specified and directed
Supply and fix in replacement male contact / moving contact for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supply and fix in replacement female contact / fixed contact jaw for gang operated air break device 11 KV complete all as directed at site by Engr-in-charge.
Supply & fix in repair Air break gang operated switch with 12 No's insulators outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement, consisting of MS Channel, HT post type insulator copper alloy, high pressure, assembly drop out fuses, operating rod 25 mm dia GI pipe, medium grade for operating from 1.2 m above GL complete including drop out fuses conforming to IS rated voltage 11 KV and for current rating 200 Amp all as specified including taking down old Air break gang operated switch .
Surface dressing n exc 15 cm deep in any type of soil, including trimming of ground, to remove vegetation and / or small inequalities complete.
Material and labour for spreading of clean & dry stone aggregate of nominal size not more than 20 mm (free from organic impurities) laid around 4 / 6 pole HT structure / surrounding area of outdoor RMU, manually without damaging any equipments, cable or parts, spreading & leveling of finished gravel uniformly in layers n. exc 150 mm thick, complete all as specified and directed. Note:- Preparation of ground level for laying of aggregate will be measured and paid separately vide BOQ item No 76
S&F in repair HT Danger notice plate of size 250 mm x 200 mm x 1.6 mm thick of mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed to pole with MS clamps, bolts and nuts of approved size complete all as specified and directed by Engr-in-Charge.
M&L in repair of Cable jointing kit for suitable for 1100 Volt LT grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 25 Sqmm complete all as specified and all as directed.
S&F Cable jointing kit for suitable for 1100 Volt LT grade cable for straight through, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 35 Sqmm complete all as specified and all as directed.
S&F Cable jointing kit for suitable for 1100 Volt LT grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 50 Sqmm complete all as specified and all as directed.
S&F Cable jointing kit for suitable for 1100 Volt LT grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 70 Sqmm complete all as specified and all as directed.
S&F Cable jointing kit for suitable for 1100 Volt LT grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 95 Sqmm complete all as specified and all as directed.
S&F Cable jointing kit for suitable for 1100 Volt LT grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 120 Sqmm complete all as specified and all as directed.
S&F Cable jointing kit for suitable for 1100 Volt LT grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 150 Sqmm complete all as specified and all as directed.
S&F Cable jointing kit for suitable for 1100 Volt LT grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 185 Sqmm complete all as specified and all as directed.
S&F in repair earth continuity conductor or main earthing strip of galvanised iron of size 25 X 4 mm complete fixed to wall / chases or buried in ground or drawn through conduit in any position or any other situation for loop earthing etc with and including epoxy insulators with necessary fixture complete all as specified and directed by Engr -in - Charge
S&F in repair earth continuity conductor or main earthing strip of Copper strip of size 20 X 3 mm complete fixed to wall / chases or buried in ground or drawn through conduit in any position or any other situation for loop earthing etc with and including epoxy insulators with necessary fixture complete all as specified and directed by Engr -in - Charge
S&F in repair earth continuity conductor or main earthing wire of galvanised steel of 4 mm dia complete fixed to wall / chases or buried in ground or drawn through conduit in any position or any other situation for loop earthing etc complete all as specified and directed by Engr -in - Charge
Material & Labour for watering with water & salt solution (5:1 ie 5 liters water and 1 kg salt) in existing earthing (approximate quantity 20 to 25 litter solution in each earthing), including testing of earth resistance for earthing with suitable earth resistance tester after pouring of solution. Note- (i) Test result shall be prepared on separate register and sign by user, mes rep & Contractor (ii) Item will be executed in every six month or before as required by user / GE (iii) Quoted rate shall be deem to include for cleaning the surrounding earth pits approx 1.0 meter radius.
M&L for Brazing of GI strip joint using brazing torch suitable at temp and using brazing rod all as specified and directed by Engr-in-charge.
M&L for Brazing of copper strip joint using brazing torch at suitable temp and using brazing rod all as specified and directed by Engr-in-charge.
M&L for Brazing of aluminium strip joint using brazing torch at suitable temp and using brazing rod all as specified and directed by Engr-in-charge.
Supply and fix in repair 25 mm size epoxy type insulator suitable for fixing earthing strip including screw etc all as directed by Engr-in-charge
S&F in repair Air termination, single pointed aluminium rod 12 mm dia and 300mm long lightning arrester, screwed for easy fitment and fixing with base plate with 10 mm holes on four corners for necessary fixing arrangement on top of PCC block (15cmx15cmx20cm) complete all as specified and as directed by Engr-in-Charge.
S&F in repair Air termination, single pointed copper rod 12 mm dia and 300mm long lightning arrester, screwed for easy fitment and fixing with base plate with 10 mm holes on four corners for necessary fixing arrangement on top of PCC block (15cmx15cmx20cm) complete all as specified and as directed by Engr-in-Charge.
M&L for PCC earthing pit in PCC 1:2:4 type B-1 of internal size 300 mm x 300 mm x 300 mm with 120 mm thick wall and 700 mm x 700 mm x 150 mm thick bed concrete and 50 mm thick precast chamber cover of RCC 1:2:4, type B1 for, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), complete all as shown in the electrical plate No 3 of SSR part –I including demolition of old pit complete.
Deployment of manpower, instrument, tools, and all connected accessories for testing of earth resistance of existing earthing at provided earth test point for each earth set by competent calibrated digital earth test meter electronic type along with accessories (earth rod set with Cu wire with clips) and recording the result dully signed with date by MES representative and contractor all as specified & as directed by Engr-in - Charge. NOTE:- Testing of each earthing shall be carried out in presence of MES and Air Force representative at the interval directed by Engineer-in- Charge and measurement shall be carried each time separately and test result shall be maintained dully signed with date by MES representative and contractor.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor of size 10 Sqmm, 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm dia galvanised iron suspension wire
Supply and fix in repair Test point terminal block made of gun metal or phosphorus bronze size of 75 mm x 75 mm x 25 mm drilled and screwed with 3 Nos 8 mm dia 25 mm long screw, fixed in position and connecting complete all as specified and as directed.
M/S NEW FAROOQ TRADERS
M/S ZAHOOR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .