Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹85,050 Per unit ₹1,134 · 75 Nos. | ₹85,050 Per unit ₹1,134 · 75 Nos. |
Tender Value
Refer Docs
Closing Date
10 Aug 2026, 1:30 pmClosed
Single Packet
Normal Tender
No
Not Applicable
Itemwise/Consigneewise
Lowest to Highest
CONSIGNEE
90 days
Expenditure
General
22
2 conditions · 2 needing a document upload
i) Procurement will be made only from the manufacturer/Authorised dealer who are registered with PCMD/Eastern Railway. In case of Authorised Dealer , Firm should upload the valid authorization certificate of the OEM, failing which their offer will be summarily rejected. OEM s should comply with sub clause 19 of the amended GTC. ii) ii) This item is reserved to be procured through class 1/class 2 local supplier as per clause 28.0 of Eastern Railway GTC.
All bidder should upload pack shot, brochure and catalogue for the tendered item. Otherwise their offer is liable to be rejected.
29 conditions
The bidder agrees to supply the tendered stores at the rates quoted by him in accordance with the IRS conditions of contracts and ( or ) specials conditions and (or) other conditions specified / attached with the Tender.
The bidder has gone through the Tender Documents consisting of Instructions to Tenderers , General Tender Conditions and IRS conditions of contracts before participating in the tender.
The offer must be kept valid for 90 days from tender opening date.
Firm has submitted documents in compliance with the "Applicable Terms and Conditions specific to Procurement of Medicines and Medical Consumables of Eastern Railway " as incorporated with Tender Document under clause 32.0 of General Tender Conditions of Eastern Railway .
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1 condition
Validity of Offer: No deviation from the offer validity period stipulated in the tender is permitted.
1 location across West Bengal · 75 Numbers total
Triple Lumen Catheter for Haemodialysis (Curved) (7f/14Gx13.5 cm). Spec: 1. Size: 12.5 F. 2. Material: Thermosensitive polyurethane material. 3. No of lumen: 3 (three). Third lumen must be usable for drug delivery, CVP monitoring, transfusions. Third lumen must be of 19G diameter. All the lumens must be marked with priming flow rate preferrable laser etched. Common hub must be reinforced to reduce kinking of lumens. Catheter shaft must be marked with depth markings for ease of insertion. Lumen must be of modified Double-D design for consistence flow even during low arterial pressure. Main shaft must have laser cut side slot. Tip must be symmetrically designed. 4. Guidewire: J tipped nitinol core kink free guide wire with thumb advancer 5. Needle: 18G introducer needle/18G safety introducer needle. 6. Dilator: 2 in number, 10 F and 12 F. 7. Package: Sterile Pack must contain the followings: beside catheter, needle, dilators, guidewire. a) 5/6 ml luer lock syringe. b) Retractable safety scalpel. c) Fenestrated drape ? large. d) 2.0/1.0 nylon suture with cutting needle. e) Antiseptic applicator wand. f) Island dressing 2 in number/or transparent wound dressing. g) 6-8 sterile gauze sponges. h) 3 sealing caps. Desirable inclusion in the Pack: A pair of gloves. Dressing gown.( Item Code No.:S58108 ,AI 26-27)
22265605
22265605
Limited - Indigenous
Goods
West Bengal
₹0
Exempted
18 Aug 2026
15 Jul 2026
1 item · 75 Numbers total
Triple Lumen Catheter for Haemodialysis (Curved) (7f/14Gx13.5 cm). Spec: 1. Size: 12.5 F. 2. Material: Thermosensitive polyurethane material. 3. No of lumen: 3 (three). Third lumen must be usable for drug delivery, CVP monitoring, transfusions. Third lumen must be of 19G diameter. All the lumens must be marked with priming flow rate preferrable laser etched. Common hub must be reinforced to reduce kinking of lumens. Catheter shaft must be marked with depth markings for ease of insertion. Lumen must be of mo dified Double-D design for consistence flow even during low arterial pressure. Main shaft must have laser c ut side slot. Tip must be symmetrically designed. 4. Guidewire: J tipped nitinol core kink free guide wire wit h thumb advancer 5. Needle: 18G introducer needle/18G safety introducer needle. 6. Dilator: 2 in number, 10 F and 12 F. 7. Package: Sterile Pack must contain the followings: beside catheter, needle, dilators, guide wire. a) 5/6 ml luer lock syringe. b) Retractable safety scalpel. c) Fenestrated drape ? large. d) 2.0/1.0 nylo n suture with cutting needle. e) Antiseptic applicator wand. f) Island dressing 2 in number/or transparent w ound dressing. g) 6-8 sterile gauze sponges. h) 3 sealing caps. Desirable inclusion in the Pack: A pair of glov es. Dressing gown.( Item Code No.:S58108 ,AI 26-27) [ Warranty Period: 30 Months after the date of deliv ery ] ]
| Delivery Location | State | Quantity |
|---|---|---|
| MD/BRSH/SEALDAH, ER | West Bengal | 75.00 Numbers |
| Total | 75 Numbers | |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .