Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.3 LAccepted-Finance 205 2ND FLOOR VARDHMAN CHAMBER LL 0 VIKASPURI WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | L1 | Accepted-Finance Responsive | |
| 2 | L2₹61.2 L+₹1.9 L (3.24%)Accepted-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L2 | Accepted-Finance Responsive |
Tender Value
₹65 L
EMD Value
₹1.2 L
Closing Date
22 Jan 2024, 1:00 pmClosed
Chief Executive Officer
Chief Executive Officer, Delhi Cantonment Board
Installation of bed elevator and passenger carrying lift at Cantonment General Hospital, Delhi Cantt
2023_DGDE_635072_1
DCB/8/EandM/C-7/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Delhi Cantt.
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Chief Executive Officer, Delhi Cantonment Board
₹1.2 L
29 Feb 2024
30 Dec 2023
23 Jan 2024
30 Dec 2023
22 Jan 2024
30 Dec 2023
30 Dec 2023 - 22 Jan 2024
Amount
Sub Head - I (Bed Elevator): Supplying, Installation, Testing and Commissioning of Bed Elevator (1360 kg) lifts having contract speed of 1.0 MPS serving different floors in the lift shaft as per detailed specification enclosed and as under:
Type of machine-Machine room less type & permanent magnet gearless motor. Type of lift Bed Elevator, MRL Load :1360 kgs Speed : 1.0 m/s Floors: 4 (G+3 Upper Floors) Travel : 12 metres (approx.) No of Floors : Ground +3 Upper Floors Stops & Openings: 4 Stops (0, 1, 2, 3) - 4 openings Controller - A.C. Variable voltage & Variable frequency (VVVF) Automatic rescue device with dry maintenance free battery of required capacity. Power 400/440 Volts, 3ph, 50 Hz, 4 wires system AC. Type of Doors:- Car: Power operated - Centre opening sliding doors made of Stainless steel: Moon rock Finish. Lift car shall have minimum entrance of 1100 mm. Lift car door shall have a fire resistance rating of 1 hr.
Landing Doors & door frame - power operated - Centre opening sliding doors & door frame shall be Stainless steel moon rock finish. Landing doors shall have a fire resistance of 2 hr. Lift car ceiling: It shall have a small circular LED-lights & Regular Fan. Ceiling shall be of Stainless Steel MoonRock/ HoneyComb/ InterLock/ hairline finish. Flooring:- 3mm thick PVC Flooring . Lift shall have all the features as per Accessible India Norms updated till date and shall be installed in compliance with the norms. 40 mm dia Stainless steel handrail not less than 600mm long at 900mm above floor level shall be fixed on all three sides of the lift car. Braile system push buttons of minimum dimensions of 20mm with height of the letter size 15mm including all facilities for physically challenged persons. Voice announcement system in the car to announce the position of the elevator in the hoistway as car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS:14665 and as amended upto date. Note:- 1) Voice announcement shall be operative during operation of ARD also. 2) During ARD operation lights/ emergency light and fan shall be in working condition. If required separate inverter should be provided for which nothing extra shall be paid.
GI boxes for control buttons shall be provided at height of 800 to 1000 mm from ground level in all landings. Call buttons shall be provided at height of 800 to 1000 mm from ground level in all landings. 2 Nos Car operating panels shall be provided - one on each side of the car door inside the lift.at a height of between 900 mm to 1100 mm from floor level Audio visual over load indicator Fireman switch at ground floor.2 way 3 station inter communication system / Telephone system. 5 mm thick, mirror 1000 mm x 800 mm. on rear panel inside the car LED fittings with necessary lux level as per NBC 2016 and noise free ventilation fan inside lift car Granite flooring inside Lift car Digital position indicators (in car and at all landings) RS 485 Module for BMS Integration Minor Building work, Scaffolding including lift shaft lighting and controls as per specifications. Automatic shut off fan to be provided battery operated Emergency light and alarm bell to be provided
Sub Head - II AMC for Bed Elevator: Comphrensive maintenance of Bed Elevator lift which include routine, preventive & breakdown maintennance for period of five years including repair/ replacement of worn out items with minimum down time and warranty and guarantee of repaired / replaced items after completion of one year guarantee period.
1st Year (4% of the amount quoted for Bed Elevator including GST)
2nd Year (4% of the amount quoted for Bed Elevator including GST)
3rd Year (5% of the amount quoted for Bed Elevator including GST)
4th Year (5% of the amount quoted for Bed Elevator including GST)
5th Year (6% of the amount quoted for Bed Elevator including GST)
Sub Head - III (8 Passenger Carrying Lift): Supplying, Installation, Testing and Commissioning of 8 Passenger Lift (554 kg) lifts having contract speed of 1.0 MPS serving different floors in the lift shaft as per detailed specification enclosed and as under:
Type of machine-Machine room less type & permanent magnet gearless motor. Type of lift 8 Passenger, MRL Load :544 kgs Speed : 1.0 m/s Floors: 4 (G+3 Upper Floors) Travel : 12 metres (approx.) No of Floors : Ground +3 Upper Floors Stops & Openings: 4 Stops (0, 1, 2, 3) - 4 openings Controller - A.C. Variable voltage & Variable frequency (VVVF) Automatic rescue device with dry maintenance free battery of required capacity. Power 400/440 Volts, 3ph, 50 Hz, 4 wires system AC. Type of Doors:- Car: Power operated - Centre opening sliding doors made of Stainless steel: Moon rock Finish. Lift car shall have minimum entrance of 900 mm. Lift car door shall have a fire resistance rating of 1 hr.
Landing Doors & door frame - power operated - Centre opening sliding doors & door frame shall be Stainless steel moon rock finish. Landing doors shall have a fire resistance of 2 hr. Lift car ceiling: It shall have a small circular LED-lights & Regular Fan. Ceiling shall be of Stainless Steel MoonRock/ HoneyComb/ InterLock/ hairline finish. Flooring:- 3mm thick PVC Flooring . Lift shall have all the features as per Accessible India Norms updated till date and shall be installed in compliance with the norms. 40 mm dia Stainless steel handrail not less than 600mm long at 900mm above floor level shall be fixed on all three sides of the lift car. Braile system push buttons of minimum dimensions of 20mm with height of the letter size 15mm including all facilities for physically challenged persons. Voice announcement system in the car to announce the position of the elevator in the hoistway as car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS:14665 and as amended upto date. Note:- 1) Voice announcement shall be operative during operation of ARD also. 2) During ARD operation lights/ emergency light and fan shall be in working condition. If required separate inverter should be provided for which nothing extra shall be paid.
GI boxes for control buttons shall be provided at height of 800 to 1000 mm from ground level in all landings. Call buttons shall be provided at height of 800 to 1000 mm from ground level in all landings. 2 Nos Car operating panels shall be provided - one on each side of the car door inside the lift.at a height of between 900 mm to 1100 mm from floor level Audio visual over load indicator Fireman switch at ground floor.2 way 3 station inter communication system / Telephone system. 5 mm thick, mirror 1000 mm x 800 mm. on rear panel inside the car LED fittings with necessary lux level as per NBC 2016 and noise free ventilation fan inside lift car Granite flooring inside Lift car Digital position indicators (in car and at all landings) RS 485 Module for BMS Integration Minor Building work, Scaffolding including lift shaft lighting and controls as per specifications. Automatic shut off fan to be provided battery operated Emergency light and alarm bell to be provided
Sub Head - IV AMC for 8 Passenger Lift: Comphrensive maintenance of 8 Passenger Lift which include routine, preventive & breakdown maintennance for period of five years including repair/ replacement of worn out items with minimum down time and warranty and guarantee of repaired / replaced items after completion of one year guarantee period.
1st Year (4% of the amount quoted for 8 Passenger lift including GST)
2nd Year (4% of the amount quoted for 8 Passenger lift including GST)
3rd Year (5% of the amount quoted for 8 Passenger lift including GST)
4th Year (5% of the amount quoted for 8 Passenger lift including GST)
5th Year (6% of the amount quoted for 8 Passenger lift including GST)
Sub Head V - Cabling & Earthing: Supply of XLPE insulated PVC outer sheathed aluminium conductor armoured UG cable of 1.1KV grade confirming to IS: 7098 (Part-I) 1988 as amended upto date of following sizes duly ISI marked as required.
4 x 25 Sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
Providing and fixing 25 mm x 5 mm GI strip in 40 mm dia GI pipe from earth electrode as required.
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc. as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
4 Way ( 4 + 12 ) , Double Door
Supplying and fixing following rating of 415 V, FP MCCB in the existing MCCB DB complete with connections, testing and commissioning etc. as required.
100 A 36 KA FP MCCB ( VTPN DB I/C )
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole (6-32 Amps)
Triple Pole (32 Amps)
M/s Dhapola Elevator and Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .