Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹38.7 L+₹2.4 L (6.57%)Rejected-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L2 | Rejected-AOC L2 | |
| 3 | L3₹40.5 L+₹4.2 L (11.6%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in Cat C (i) |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Nov 2020, 6:00 pmClosed
CWE Jammu
HQ CWE Jammu Pin- 900172 C/o 56 APO
REPAIR AND MAINT OF CENTRAL AC PLANT AND PACKAGE TYPE AC PLANTS UNDER GE SATWARI
2020_MES_381566_1
CWE/JP-42/2020-21
Open Tender
Support/Maintenance Service
Item Rate
180 days
AOR GE Satwari
Class D, Cat c(i)
9 documents required · 9 mandatory
₹500
G E Satwari
₹90,000
Yes
30 Dec 2020
28 Sept 2020
11 Nov 2020
28 Sept 2020
4 Nov 2020
19 Oct 2020
Amount
Material and labour for servicing of AHU Floor mounted of different capacities including washing of coils with descaling chemicals and pressure pump including cleaning of drain pipe, dusting of all filters as well as cleaning of the outer filters and inner filters with proper cleaning of the AHU body with all necessary equipment and apparatus, complete all specified and directed. NOTE : The work shall be carried out by the authorized OEM.
Material and labour for servicing of AHU ceiling mounted of different capacities including washing of coils with descaling chemicals and pressure pump including cleaning of drain pipe, dusting of all filters as well as cleaning of the outer filters and inner filters with proper cleaning of the AHU body with all necessary equipment and apparatus, complete all specified and directed. NOTE : The work shall be carried out by the authorized OEM.
Supply & fixing in replacement of V Belt No. A-42 for AHU, complete all specified and directed. Make : Fenner / Unigrip / Navyug / Escon / Mitsubishi / Dunlup.
Supply & fixing in replacement of V Belt No. A-40 for AHU, complete all specified and directed. Make : Fenner / Unigrip / Navyug / Escon / Mitsubishi / Dunlup.
Supply & fixing in replacement of V Belt No. A-44 for AHU, complete all specified and directed. Make : Fenner / Unigrip / Navyug / Escon / Mitsubishi / Dunlup.
Supply & fixing in replacement of V Belt No. A-26 for AHU, complete all specified and directed. Make : Fenner / Unigrip / Navyug / Escon / Mitsubishi / Dunlup.
Supply & fixing in replacement of V Belt No. A-32 for AHU, complete all specified and directed. Make : Fenner / Unigrip / Navyug / Escon / Mitsubishi / Dunlup.
Supply & fixing in replacement of V Belt No. A-30 for AHU, complete all specified and directed. Make : Fenner / Unigrip / Navyug / Escon / Mitsubishi / Dunlup.
Supply & fixing in replacement of V Belt No. A-61 for AHU, complete all specified and directed. Make : Fenner / Unigrip / Navyug / Escon / Mitsubishi / Dunlup.
Supply & fixing in replacement of V Belt No. A-35 for AHU, complete all specified and directed. Make : Fenner / Unigrip / Navyug / Escon / Mitsubishi / Dunlup.
Supply and fixing in replacement of HEPA filter microfibre material for ducts of size 610mm x 610mm x 305mm (clear upto 0.3 micron) box type complete for 20000 CFM capacity AHU, complete all specified and directed. Make : Athlete/Thermodyne/Indfoss/John fowlers/ Denfoss.
Supply and fixing in replacement HEPA filter microfibre material, box type of size 600X600x305mm suitable to be installed in existing AHU 13000 CFM of 90 TR AC plant, complete all specified and directed. Make :Athlete/Thermodyne/Indfoss/John fowlers/ Denfoss
Supply and fixing in replacement microvee pre filter microfibre material, 10 micron, box type of size 610x610x50mm suitable for AHU of central AC plant, complete all specified and directed. Make - Athlete/Thermodyne/Indfoss/John fowlers/ Denfoss
Supply and fixing in replacement microvee pre filter, 10 micron, box type of size 520x470x50mm suitable for AHU of central AC plant, complete all specified and directed. Make - Athlete/Thermodyne/Indfoss/John fowlers/ Denfoss
Supply and fixing in replacement microvee pre filter of microfibre material , 10 micron, box type of size 500x470x25mm suitable for AHU of central AC plant, complete all specified and directed. Make -Athlete/Thermodyne/Indfoss/John fowlers/ Denfoss
Supply and fixing in replacement microvee pre filter of microfibre material, 10 micron, box type of size 500x480x50mm suitable for AHU of central AC plant, complete all specified and directed. Make - Athlete/Thermodyne/Indfoss/John fowlers/ Denfoss
Supply and fixing in replacement microvee pre filter of microfibre material, 10 micron, box type of size 610x305x50mm suitable for AHU of central AC plant all as specified and directed. Make - Athlete/Thermodyne/Indfoss/John fowlers/ Denfoss
Supply and fixing in replacement microvee pre filter of microfibre material, 10 micron, box type of size 590x430x25mm suitable for AHU of central AC plant, complete all specified and directed. Make - Athlete/Thermodyne/Indfoss/John fowlers/ Denfoss
Supply and fixing in replacement microvee pre filter of microfibre material, 10 micron, box type of size 500x250x50mm suitable for AHU of central AC plant, complete all specified and directed. Make - Athlete/Thermodyne/Indfoss/John fowlers/ Denfoss
Note:- For Srl item No 11 to 19 Size of pre filter and Hepa filter may vary from 5 to 10 % in length and width. Contractor is advice to visit the site before quoting their rates.
Servicing of AHU of 2 x 26 TR central AC Plant including washing and cleaning of coils with chemical and pressure pump including dusting of all filters with proper cleaning of AHU body with all necessary arrangement including cleaning of drain pipe all as specified and directed.
Servicing of AHU including washing and cleaning of coils with chemical and pressure pump of capacity 20000 CFM including dusting of all filters with proper cleaning of AHU body with all necessary arrangement including cleaning of drain pipe all as specified and directed.
Servicing of AHU including washing and cleaning of coils with chemical and pressure pump of capacity 13000 CFM including dusting of all filterswith proper cleaning of AHU body with all necessary arrangement including cleaning of drain pipe all as specified and directed.
Material and labour for trouble shooting/fault detection in case of major break down of the AC plant 3 X190 TR from the authorized person/company representative of the Carrier company for the smooth functioning and servicing of the plant as well as for un interrupted running. The job includes step by step check up of the plant with proper diagram and replacing of the burnt or unserviceable parts if any like resistors or counters or timers or repair to electronic circuit board etc.
Material and labour for opening and dismantling both sides covers of condenser and descaling of condenser unit (set of Two) for AC plant of 2 X 95 TR by pumping descaling chemicals with descaling pump, brushing with rods, cleaning/ oiling of tubes, replacement of gasket and reassembling it after descaling complete all as directed. Note :- The descaling of the condensers of the plant will be carried out by the authorised service representative of the OEM.
Dismantling and taking out old unserviceable compressor of capacity 95TR Make carrier from chiller unit of capacity 190 TR by removing & recovery of Refrigerant gas in the cylinder, recovery of compressor oil, unscrewing and carried out at civil work shop for overhauling including freight charges up and down and refixing the same after repair in original position complete all as specified and directed. Note :- 1. Any repair/overhauling in compressor unit shall be measured and paid under relevent item. 2. If any damage to compressor during poor handling/hoisting/lifting, the same will be rectified by contractor without any extra cost to the deptt.
Material and Labour for overhauling of compressor 95 TR capacity by carrying out extensive electrical and mechanical repairs incl repair replacement of fwg items: a) Replacement of all existing bearings. b) Cleaning and Refitting of existing stater into body shell c) Cleaning of pores with pressure jet d) Testing of winding e) Pressure testing before and after assembling. and necessary connection and testing on complition complete all as specified and directed. Note :- Any minor items like nut bolt or replacement of other unserviceable minor part required while overhauling of compressor are included in quoted rate by the contractor.
Material and Labour for replacement of unserviceable internal oil filter and external oil filter suitable for screw compressor of chiller unit 190 TR, complete all as specified and directed. Make: carrier model: 30HXC190A
Material and labour for replacement of compressor oil approved by OEM suitable for carrier/Voltas Make compressor, complete all as specified and directed.
Material and labour for repair of chiller/condensor of chiller unit 190 TR make: Carrier Model: 30HXC190A detecting leakage in the system and rectify the leakage in the chiller/condensor of system, flushing the system of any rust and dirt with antirust chemicals, nitrogen pressure testing of chiller & condensor and assembling the system and testing complete, complete all as specified and directed.
Material and labour for replacement of nozzle set of sprinkler for existing cooling tower cap 200 TR and testing all as specified and directed.
Material and labour for replacement of suction pressure transducer in suction pipe of compressor of central AC plant of 190 TR capacity, complete all as specified and directed. Note: The work shall be carried out by the authorized representative of OEM.
Material and labour for replacement of discharge pressure transducer in discharge line of compressor of central AC plant 190 TR capacity, complete all as specified and directed. Note: The work shall be carried out by the representative of OEM.
Material and labour for replacement of high pressure switch of central AC plant 190 TR capacity, complete all as specified and directed. Note: The work shall be carried out by the representative of OEM.
Material and labour for replacement of flow switch of central AC plant 190 TR capacity completion, complete all as specified and directed. Note: The work shall be carried out by the representative of OEM.
Material and labour for trouble shooting/fault detection in case of major break down of the AC plant 3X90 TR from the authorized person/company representative of the Voltas for the smooth functioning and servicing of the plant as well as for un interrupted running. The job includes step by step check up of the plant with proper diagram and replacing of the burnt or unserviceable parts if any like resistors or counters or timers or repair to electronic circuit board etc.
Material and labour for opening and dismantling both sides covers of condenser and descaling of condenser unit (set of Two) for AC plant of 90 TR by pumping descaling chemicals with descaling pump, brushing with rods, cleaning/ oiling of tubes, replacement of gasket and reassembling it after descaling, complete all as specified and directed. Note : The descaling of the condensers of the plant will be carried out by the authorised service representative of the OEM.
Material and labour for replacement of suction pressure transducer in suction pipe of compressor of central AC plant 90 TR capacity by pumping down/recovering of refrigerant gas from the compressor, fixing of HP switch charging recovered refrigerant gas and testing on completion, complete all as specified and directed. Note: The work shall be carried out by the authorized representative of OEM.
Material and labour for replacement of discharge pressure transducer in suction pipe of compressor of central AC plant 90 TR capacity by pumping down/recovering of refrigerant gas from the compressor, fixing of HP switch charging recovered refrigerant gas and testing on completion, complete all as specified and directed. Note: The work shall be carried out by the authorized representative of OEM.
Material and labour for replacement of high pressure switch in discharge pipe of compressor of central AC plant of 90 TR capacity by pumping down/recovering of refrigerant gas from the compressor and testing on completion all as specified and directed. Note: The work shall be carried out by the representative of OEM.
Material and labour for replacement of temperature sensor of central AC plant of 90 TR capacity by pumping down/recovering of refrigerant gas from the compressor and testing on completion all as specified and directed. Note: The work shall be carried out by the representative of OEM.
Dismantling and taking out compressor of capacity 90 TR Make: Voltas and transport for taking out upto civil work shop for overhauling including freights charges up and down, complete all as specified and directed. Note: 1. Any repair/overhauling in compressor unit shall be measured and paid under relevent item. 2. If any damage to compressor during poor handling/hoisting/lifting, the same will be rectified by contractor without any extra cost to deptt.
Material and labour for overhauling of compressor 90 TR capacity by carrying out extensive electrical and mechanical repairs incl repair replacement of fwg items: a) Replacement of all existing bearings. b) Cleaning and Refitting of existing stater into body shell c) Cleaning of pores with pressure jet d) Testing of winding e) Pressure testing before and after assembling. and necessary connection and testing on complition, complete all as specified and directed. Note: Any minor items like nut volt or replacement of other unsv minor part required while overhauling of compressor are included in quoted rate.
Material and labour for refixing and testing of compressor 90 TR Make: Voltas after overhauling, complete all as specified and directed.
Material and labour for leakage testing and gas charging including checking of leakage in both low and high side of the system by feeding dry nitrogen to maintain adequate pressure in the system, restoring the leakages including replacement of teflon sealings of all refrigerant link valves liquid lines, suction line, dicharge line of compressors, gland packages of all angle valves flaring of all connections etc for 90 TR compressor, complete all as specified and directed.
Supply and Fixed in replacement of internal and external oil filters for capacity 90 TR compresoor, complete all as specified and directed. Make: Voltas all as specified and directed.
Material and labour for replacement of flow switch of central AC plant 90 TR capacity, complete all as specified and directed. Note: The work shall be carried out by the representative of OEM.
Material and labour for charging refrigerant gas R 134 A in the compressor system after detecting any leakage, rectifying the leakage in the system, proper evacuation and pressure testing with Nitrogen gas for the desired pressure and testing on completion all as specified and directed. Note : The work shall be carried out by the representative of OEM
Material and labour for trouble shooting/fault detection in case of major break down of the AC plant 2X26 TR from the authorized person/company representative of the Blue star for the smooth functioning and servicing of the plant as well as for un interrupted running. The job includes step by step check up of the plant with proper diagram and replacing of the burnt or unserviceable parts if any like resistors or counters or timers or repair to electronic circuit board etc.
Material and labour for opening and dismantling both sides covers of condenser and descaling of condenser unit (set of Two) for AC plant of 26 TR by pumping descaling chemicals with descaling pump, brushing with rods, cleaning/ oiling of tubes, replacement of gasket and reassembling it after descaling, complete all as specified and directed. Note: The descaling of the condensers of the plant will be carried out by the authorised service representative of the OEM.
Material and labour for charging refrigerant gas R 407 A in the compressor system after detecting any leakage, rectifying the leakage in the system, proper evacuation and pressure testing with Nitrogen gas for the desired pressure and testing on completion, complete all as specified and directed. Note : The work shall be carried out by the representative of OEM
Opening and taking out the front cover of hot water boiler of cap 225 KW and taking out the existing heating element from the boiler drum and refixing the same in old position after descaling the heating element and hot water boiler with suitable chemical and testing on completion, complete all as specified and directed.
S&F in replacement of heating element 25 KW of existing model suitable for hot water boiler of make: Rapid Cool for heating system in 3 X 190 TR central AC Plant, complete all as specified and directed.
Opening ang taking out the front cover of hot water boiler of cap 55 KW and taking out the existing heating element from the boiler drum and refixing the same in old position after descaling the heating element and hot water boiler with suitable chemical and testing on completion all as directed by Engr-in-Charge.
S&F in replacement of heating element of existing wattage and model suitable for hot water boiler of make: Rapid Cool for heating system in 2 X 26 TR central AC Plant complete all as specified and directed.
Supply and fixing in replacement Heating strip 3 KW, 3 feet long as per existing. Make : DASPASS /HOT WELL/AIREX
Supply and fixing in replacement Heating strip 2 KW 2 feetlong as per existing, Make : DASPASS /HOT WELL/AIREX
Servicing of 5 TR Package type AC Plant including oiling, greasing of Blower fan motor and outer unit fan motor, cooling coil, checking of electric circuit and checking of refrigerent Gas as per requriment for smooth functioning of package type AC, complete all as specified and directed. (replacement of unserviceable burnt spare parts of machine shall be measured and paid for separately under respective items).
Material & labour for replacement of Fan Blade of outer unit of 3 x 5 TR package type AC plant or 5 TR cold storage Make: Blue star of size 450 mm sweep complete all as specified and directed.
Material & labour for replacement of Fan Motor of outer unit of 3 x 5 TR package type AC plant or 5 TR cold storage Make: Blue star of size 450 mm sweep complete all as specified and directed.
Supply and fixing new compressor of cap 5 TR suitable for 3 phase power supply. Make of Plants : Bluestar, Make of compressors : Carrier/Blue star/Kirloskar/Techmshaw
Supply and charging the refrigerant gas R-22 in 5 TR AC plant or 5 TR cold storage including detecting leakage and rectifying the defect and testing complete all as specified and directed.
Supply and fix in replacement of Walk-in-cooler (Chiller Room Refrigeration unit) having refrigeration capacity: 10000 BTU/Hr @ +2 degree celsius Room temerature and 45 degree celsius ambient temperature, Compressor: CR-30 Emersion three phase (Hermetic type) cubical Wall/ Slim Roof mounted Evaporator-SS(304) body high CFM evaporator Refrigerant: R-22, Condensing medium: Air cooled, along with elctrical control panel AC single phase 230 volts complete all as specified & directed. Make :- Blue star / Shri Ram / Sidhwal
Supply, errection, testing and commissioning of water softening plant of flow Rate 3 Cum/Hr with following specification: New generation softener -NGS-3B, along with MPV (Multi port Valve) , Resin with Ejector Assly incl Frontal piping, one FRP pressure vessel fitted with plastic internal fittings, One No. multiport valve with hand operated leaver, One no. combined salt tank of LLDPE/FRP with fittings and brine filtering media, Two No. pressure gauge one each at inlet and outlet, One No. rate of flow indicator all as specified and directed. Make: ION Exchange / Kent / Zero-B / Livpure / Aquaguard.
Supply & fixing in replacement contactor MNX 25 Amps, 3 Pole, with Coil Voltage, 220 Volt and NO NC block MNX A1 and making electric connections all as specified and directed. Make : L & T / ABB /Indoasian
Supply & fixing in replacement contactor MNX 25 Amps, 3 Pole, with Coil Voltage, 220 Volt and NO NC block MNX A2 and making electric connections all as specified and directed. Make : L & T/ABB/Indoasian
Material and labour for Maintenance of centrifugal/ monoblock pump set 20 HP capacity by means greasing, oiling, replacement of gland of suitable size to stop water leakage from pump set, replacement of nuts, bolts etc as directed at site.
Material and labour for disconnecting the electric connections of the electric motor, dismantling the pump and motor from the foundation, taking out the old unserviceable winding wire, cleaning the slots for rewinding, rewinding the electric motor Make Siemens 3 Ph, 415 volts 20 HP with suitable size of super enamelled copper binding wire including replacement of suitable size bearings, including allied materials like cotton tapes, glass sleeves, varnishing and assembling the motor and coupling with pump and fixing on foudation complete and testing, complete all as specified and directed.
Material and labour for disconnecting the electric connections of the electric motor, dismantling from the pump foundation of AHU or from cooling tower and taking out the old unserviceable winding wire, cleaning the slots, rewinding the electric motor 3 Ph, 415 volts 7.5 HP with suitable size of super enamelled copper binding wire including replacement of suitable size bearings, including allied materials like cotton tapes, glass sleeves, varnishing and assembling the motor and coupling with pump and fixing on foudation or with AHU complete and testing all as specified.
Material and labour for disconnecting the electric connections of the electric motor, dismantling from the pump foundation of AHU or from cooling tower and taking out the old unserviceable winding wire, cleaning the slots, rewinding the electric motor 3 Ph, 415 volts 3.7 KW with suitable size of super enamelled copper binding wire including replacement of suitable size bearings, including allied materials like cotton tapes, glass sleeves, varnishing and assembling the motor and coupling with pump and fixing on foudation or with AHU complete and testing all as specified.
Supply and fixed in replacement of coupling of motor-pump of different capacity 7.5 HP to 20 HP and its allingnment of its shaft in proper position for smoothly working all as specified and directed.
Dismantiling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. Contd to Srl item No 72.01
(iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (using 40 mm graded crushed stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing). (a) 01 set of 600 Amps TPN aluminium bus bar of suitable length and of cross section as per design with colour coding. Bus bar shall be designed to with stand a fault level of 25 KA at 415 volts. (b) MCCB 4 pole 400 Amp, 36 KA with thermal and magnetic release with Ics=100% Icu conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and overload protection:12 IN Contd to Srl item No 72.02
Material and labour for complete repair and restoring of humidity control system with replacement of burnt out pump along with motor and GI pipe of various size (15 to 40 mm) with replacement of humidity stat control switch making it functional with repair of heavy duty water tank and all necessary connection as required for smooth functioning of moisture and humidity control function all as specified and directed.
Material and labour for replacement of single phase preventer for central AC Plant main control panel as per exisiting Make and complete all as specified and directed.
Supply and Fixed in replacement of butterfly valves 80 mm dia all as specified and directed.
Supply and Fixed in replacement of butterfly valves 100 mm dia all as specified and directed.
Supply and Fixed in replacement of butterfly valves 150 mm dia all as specified and directed.
Material and labour for duct insulation with resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 50mm as specified including the following: (a) M&L for cleaning the duct surface (to be insulated) by scraping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign care so that all ducts joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50mm wide, to make the insulation leakproof. (d) M&L for securing the insulation with and including mechanical fastened nylon/steel straps of size 12 mm/50mm at maximum intervals of 1.2 mtrs.
Supply and laying MS pipe light grade 40 mm bore in oulet of AHU of different capacity on floor or wall as required, complete all as specified and directed.
Supply and fix in replacement of motherboard card with software for carrier Make water cooled screw chiller 30HXC, complete all as specified and directed.
Supply and fix in replacement of EXV card of carrier Make water cooled screw chiller 30HXC, complete all as specified and directed.
SATISH AND CO
BMMJ TRADERS AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .