Loading…
Loading…
Tender Value
₹57.8 L
EMD Value
₹1.2 L
Closing Date
30 Jan 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Deposit Work
TENDER
15 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderer shall ubmit requisite information as per Annexure-VIB of GCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from hartered Accountant duly supported by Audited Balance Sheet.
a. The tenderer must have successfully completed any of the following during last 07 [seven] years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Signal and Telecommunication: - Similar single work means carrying out "Execution of any Indoor or Outdoor signaling work (PI/RRI/EI/Automatic block signaling/IBS/IBH/BPAC/LC gate interlocking)".
NOTE:- For the following equipment's after award of the contract and before supply of equipment "MoU with RDSO approved firm (if available) or in case not available, MoU with OEM who meets the RDSO 1.1.1 specification" covering supply. installation, testing and commissioning of system shall be submitted including after sales support required during the warranty period.
38 conditions · 8 needing a document upload
Submit your bank details i.e. Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number.
As per Correction slip "The tenderers shall submit a copy of certificate stating that all their statements/documents submitted along with bid are true and factual. Standard format of certificate to be submitted by the bidder is enclosed as Annexure-V. In addition to Annexurc-V, in case of other than Company/Proprietor firm. Annexure -V(A) shall also be submitted by the each member of a Partnership Firm / Joint Venture (JV) / Hindu Undivided Family (HUH / Limited Liability Partnership (LLP) etc., as the case may be. Non submission of above certificate(s) by the bidder shall result in summarily rejection of his/their bid.It shall be mandatorily incumbent upon the tenderer to identify,state and ubmit the supporting documents duly selfattested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document. [Format available in correction slip}
In case the Tenderer is a Partnership Firm: [i] A notarized copy Partnership deed. [ii] A notarized or registered Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered).
In case the Tender is a HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF and (iii) All other documents in terms of explanatory notes in clause 10 of IRGCC April 2022.
In case the Tender is a Sole Proprietorship Firm: (i) All other documents in terms of explanatory notes in clause 10 of IRGCC April 2022.
In case the Tenderer is a Company registered under Companies Act-2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company. (ii) A copy of Certificate of Incorporation. (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. and (iv) Copy of PAN number of the Company
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation. (iii) a copy of Power of Attorney/Authorisation issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. and (iv) copy of PAN number of the LLP Firm.
In case the Tenderer is a Registered Society & Registered Trust: (i) A copy of the Certificate of Registration. (ii) Deed of Formation. (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
If the mandatory documents asked for in the E-Tender Document are not submitted along with the tender, the tender submitted otherwise will be treated as incomplete and will not be considered.
The quantities shown in above Schedule are approximate and are as a guide to give the tenderer(s) an idea of quantum of work involved. The Railway reserves the right to increase/ decrease and/or delete or include any of the quantities given above and no extra rate will be allowed on this account.
All rates quoted in the tender shall be deemed to be inclusive of all Taxes royalties payable by the contractor s to the Government or public body or local authority and no additional amount will be paid or claim entertained on this account by the Railway.
It is responsibility of the tenderer that they ensure to see any Corrigendum of the tender to check the corrigendum on the website from time to time.
The works are required to be completed within a period of 6 months as mentioned.
The Tenderer(s) shall keep the offer open for a minimum period of 45 days from the date of opening of the Tender. It is understood that the tender documents have been sold/issued to the Tenderer(s) and the Tenderer(s), is / are permitted to tender in consideration of the stipulation on his / their part that after submitting his / their tender subject to the period being extended further, if required by mutual agreement from time to time, he will not resale from his offer or modify the terms and conditions thereof in a manner not acceptable to the DRM/S&T/Divisional Engineer of SW Railway, Should the tenderer fail to observe or comply with the foregoing stipulation, the amount deposited as Earnest Money for the due performance of the above.
If the tender is accepted, the amount of Earnest Money will be retained and adjusted as Security Deposit for the due and faithful fulfillment of the contract. This amount of Security Deposit shall be forfeited, if the Tenderer(s)/Contractor(s) fail to execute the Agreement Bond within 7 days after receipt of notice issued by Railway that such documents are ready or to commence the work within 15 days after receipt of the order.
Rights of the Railway to Deal with Tender: The authority for the acceptance of the tender will rest with the Railway. It shall not be obligatory on the said authority to accept the lowest tender or any other tender and no Tenderer's(s) shall demand neither any explanation for the cause of rejection of his /their tender nor the Railway to assign reasons for declining to consider or
If the tenderer(s) expires after the submission of his / their tender or after the acceptance of his their tender, the Railway shall deem such tender cancelled. If a partner of a firm expires after the submission of their tender or after the acceptance of their tender, the Railway shall deem such tender as cancelled, unless the firm retains its character
No post tender correspondence will be permitted, and the tender shall be decided based on the documents uploaded with the offer only.
The Tenderer's shall not add any conditions on their own in the tender documents while submitting their offer. Any such conditions if stated and if tender conditions are in violation of the Railway s, may lead to summary rejection of the offer. Railway reserves the right to reject such tenders summarily without assigning any reasons whatsoever.
The responsibility of uploading the correct documents lies with the Tenderer's. In case, the documents uploaded are found manipulated/forged, the offers of such Tenderer's will not be considered and such Tenderer's are liable to be debarred to participate for future works duly forfeiting their Earnest Money and the tenderer/contractor shall have no claims whatsoever in this regard. Railway reserves the right to determine/rescind the contract entered into in case of such false certificates/documents at any stage of the contract treating it as default of the contractor.
Tender Opening will be done any time after the tender closing time. Tenderers are not required to be present during the opening. Railway reserves right to open the tender any time after the time of closing of tender.
Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all-inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion.
Railways, being principal employer are required to ensure that the contractors are complying with the provisions of the contract labour (R&A) Act, 1970 and Minimum wages Act, 1948 strictly and arranging prescribed minimum wages to the contractor labourers vide Railway Board letter No. 2016/E(LL)/AT/MW/1Dt. 05.06.2017.
The Tenderer(s) shall quote his / their rates as a percentage above or below the Schedule of Rates of South Western Railway as applicable to Mysore Division except where he/they are required to quote item rates and must tender for all the items shown in the Schedule of approximate quantities attached. The quantities shown in the attached Schedule are given as a guide and are approximate only and are subject to variation according to the needs of the Railway. The Railway does not guarantee work under each item of the Schedule.
Tender cost is not transferable and the amount once paid is non- refundable.
Signal and Telecommunication work in connection with construction of RUB by NHAI for traffic LC-No.162 @ HLK Yard & Interlocked LC-No.20 @ CTA Yard. [Allocation:008445-21]
21-SNT-MYS-2025-01~SWR
21-SNT-MYS-2025-01
Open
Works - General
6 Months
Dharwad, Karnataka
₹0
₹1.2 L
30 Jan 2026
8 Jan 2026
16 Jan 2026
75 items across 4 schedules · ₹26,04,783.01 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. Laying of cables is not included in this schedule. | Metre | 2000.00 | 34.65 | 69,300 |
| 2 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth of 0.6m to accommodate the additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. Laying of cables is not included in this schedule. [Cement, river sand and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre | 50.00 | 169.95 | 8,497.5 |
| 3 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, laying of DWC/ RCC pipes with collar/coupling, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site. During excavation of trench it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying of cables is not included in this schedule.(Supply of DWC/RCC pipes with couplers/ collars is not included in this schedule). | Metre | 20.00 | 208.35 | 4,167 |
| 4 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule.(Supply of DWC/RCC pipes with couplers/ collars is not included in this schedule). | Metre | 20.00 | 270.83 | 5,416.6 |
| 5 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule.)[Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre | 12.00 | 181.95 | 2,183.4 |
| 6 | Provision of GI pipes-(50/100mm dia) for cable laying with offset at both ends and with couplings over girder bridges by fixing on suitable MS Clamps at an interval of 2 Mtrs. The ends of the pipes shall be closed with brick masonry work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. Supply of GI pipes with couplings and laying of cables is not included in this schedule.[MS angles, flats, bolts and nuts for manufacturing fixing clamps, bricks, river sand , cement and all other miscellaneous required for the work shall be supplied by the Contractor]. | Metre | 42.00 | 215.25 | 9,040.5 |
| 7 | Provision of GI pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. Supply of GI pipes with couplings and laying of cables is not included in this schedule.[Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre | 42.00 | 168.08 | 7,059.36 |
| 8 | Laying of signaling/power/telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply of cables is not included in this schedule). | Metre 13000.00 | — | 9.83 | 1,27,790 |
| 9 | Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and leveling. | Metre | 2000.00 | 8.33 | 16,660 |
| 10 | Supply of RCC cable markers as per drawing No.CSTE/CN/OFC/1. The lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site. | Numbers | 100.00 | 166.29 | 16,629 |
| 11 | Digging of pit to a depth of 800mm of size 300mmX300mm, casting of concrete foundation of size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road/crossing. | Numbers | 100.00 | 121.43 | 12,143 |
| 12 | Excavation of cable coil pit to a size of 1.5mx1.5m and depth as instructed Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables, and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and leveling.[Country bricks of size 220mmx100mmx60mm (app) shall be supplied by the Contractor]. | cum | 10.00 | 513 | 5,130 |
| 13 | Supply of Double walled corrugated pipe - 103.5mm inner dia & 120mm outer dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as specified in Vol.II of the Tender document. | Metre | 240.00 | 263.2 | 63,168 |
| 14 | Supply of GI pipes - 50mm dia -3.65mm thick as specified in Vol.II of the Tender document. | Metre | 36.00 | 343.2 | 12,355.2 |
| 15 | Excavation of pit, casting concrete foundation and erection of apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, river sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor.] | Numbers | 2.00 | 9,875.3 | 19,750.6 |
| 16 | Excavation of pit, casting concrete foundation and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, river sand, stone jelly of size 20/25mm, 37mm hard wood planks, latching arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor] | Numbers | 2.00 | 6,966.6 | 13,933.2 |
| 17 | Excavation of pit in and around the existing l o c a t i o n boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signaling system, releasing the cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re- connected.[All materials required for the work shall be supplied by the Contractor]. a. Shifting of apparatus case (full) | Numbers | 2.00 | 2,895 | 5,790 |
| 18 | Excavation of pit in and around the existing l o c a t i o n boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signaling system, releasing the cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re- connected.[All materials required for the work shall be supplied by the Contractor]. b. Shifting of apparatus case (half) | Numbers | 2.00 | 1,916.25 | 3,832.5 |
| 19 | Excavation of pit in and around the existing l o c a t i o n boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signaling system, releasing the cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re- connected.[All materials required for the work shall be supplied by the Contractor]. c. Shifting of apparatus case (Quarter) | Numbers | 2.00 | 1,583.25 | 3,166.5 |
| 20 | Termination of new main/tail cables on the existing terminals/ fuse blocks in apparatus cases/ battery boxes/ CT boxes/ cable termination racks as per approved circuit diagram. The terminal particulars are to be repainted /corrected on the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created for entry of new cables in the apparatus cases with masonry brick work and sealing the bottom of the apparatus cases/ cable termination racks with cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, river sand and all other required miscellaneous materials shall be supplied by the contractor]. | Numbers | 700.00 | 39.78 | 27,846 |
| 21 | Termination of main, tail, Signaling and power cables and internal wiring on terminal/ fuse blocks in new apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay r o o m . The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. a. Termination on 25/60mm PBT terminals (new location) (Phynolic sheet) | Numbers | 100.00 | 93.16 | 9,316 |
| 22 | Termination of main, tail, Signaling and power cables and internal wiring on terminal/ fuse blocks in new apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay r o o m . The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. a. Termination on 25/60mm PBT terminals (new location) (Phynolic sheet) b. Termination on PBT fuse block (new location) (Phynolic sheet) | Numbers | 20.00 | 113.56 | 2,271.2 |
| 23 | Termination of main, tail, Signaling and power cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. a. Termination of cables on 25/60mm PBT terminals (existing location) | Numbers | 20.00 | 81.68 | 1,633.6 |
| 24 | Termination of main, tail, Signaling and power cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. b. Termination of cables on PBT fuse block (existing location) | Numbers | 20.00 | 102.08 | 2,041.6 |
| 25 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.(Supply of all types of relays, plug boards, connectors and retaining clips is not covered in this schedule). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. c. Wiring of Signal/ Point/ LC control circuit (up to 12 relays) | Set | 1.00 | 6,137.85 | 6,137.85 |
| 26 | . Alterations to painted termination/ wiring particulars of functions in the existing apparatus cases, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor]. a. Alteration to painting particulars (apparatus case - Full size) | Numbers | 55.00 | 884.85 | 48,666.75 |
| 27 | Alterations to painted termination/ wiring particulars of functions in the existing apparatus cases, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the C o n t r a c t o r ] . b. Alteration to painting particulars (apparatus case - half size) | Numbers | 20.00 | 464.1 | 9,282 |
| 28 | Alterations to painted termination/ wiring particulars of functions in the existing apparatus cases, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the C o n t r a c t o r ] . c. Alteration to painting particulars (apparatus case-quarter size/ CT box) | Numbers | 10.00 | 337.45 | 3,374.5 |
| 29 | Excavation of pit, casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects.[Foundation bolts, cement, river sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 5.00 | 5,008.2 | 25,041 |
| 30 | Erection of surface base, signal pole, mounting of colour light signal up to 4 aspects complete on Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole lamp holder, filament switching units, CLS transformer, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, lens guard, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, LED aspects, current regulators, lamp holders, lamps, filament switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Collar Rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor]. | Numbers | 3.00 | 5,501.2 | 16,503.6 |
| 31 | Removal of existing CLS units, fixing of new CLS units with LED aspects/ lamps, holders etc., up to four aspects, directly or using off set brackets duly drilling holes on the signal poles, provision of EWS locks wherever necessary, termination of tail cables and wiring using wire PVC3/0.75mm copper and painting of aspect. The new tail cables shall be taken through the signal poles and the unwanted cables duly released.(Supply of CLS unit with LED aspects/ lamps holders, CLS transformers is not included in this schedule.) [EWS locks, Wire PVC 3/0.75mm copper lenses guard, wire netting arrangements, paints and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 1.00 | 5,999.25 | 5,999.25 |
| 32 | Provision of earth electrodes as per drawing No.SG/SN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closure by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. Supply of 19C cable is not covered in the scope of this schedule.[MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, river sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 20.00 | 1,799 | 35,980 |
| 33 | Supply and provision of earth electrodes as per RDSO specification No.RDSO/SPN/TC/75/2008 with copper base of size 1000mm X 1000 X 3mm, for sophisticated signaling equipments. The work involves digging of pit to a depth of 2.5m and placing of the copper plate and connecting it to the signaling equipments through copper strips 25mm X 3mm (2 No's) by welding and taking it through to the wall of the equipment room where it shall be connected to a copper bus bar fixed on the wall. The work also involves providing a perforated up to 2m HDPE pipe 75mm OD - 4mm thick, 2600mm long vertically at the centre of the copper plate which shall be used for watering. The work also involves back filling the pit by a mixture of app 200kg of charcoal/ graphite and soil free from sand, gravel and stone in the ratio of 6:1. The pit shall be covered using an RCC slab 100mm thick supported by an MS angle 50mmx50mmx3mm and MS rods 6mm dia. The HDPE pipe shall be covered using concrete enclosure with GI cover and handle. [Copper earth plate, copper strips, HDPE pipe, charcoal, RCC slabs, MS angles and rods, and all other miscellaneous materialsrequired for the work shall be supplied by the Contractor]. | Numbers | 4.00 | 31,118 | 1,24,472 |
| 34 | Supply of Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as per specification/ drawing/ description enclosed in this document. b. Supply of colour light Signal pole (3.6m) | Numbers | 3.00 | 2,974 | 8,922 |
| 35 | Supply of surface base to suit CLS Signal pole 140mm dia with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 5.00 | 4,118 | 20,590 |
| 36 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection as per specification/ drawing/ description enclosed in this document. b. Supply of ladder with platform and shoes for 3.6m CLS pole | Numbers | 5.00 | 3,089 | 15,445 |
| 37 | Supply of Colour Light Signal Multi Unit type - complete for 4/ 3/ 2 aspect with mounting socket, with necessary inspection as per specification/ drawing/ description enclosed in this document. c. Supply of colour light Signal unit - 2 aspect | Numbers | 3.00 | 8,580 | 25,740 |
| 38 | Supply of PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection as per specification/ drawing/ description enclosed in this document. a. Supply of PBT terminal - 25mm centre | Numbers | 1000.00 | 44 | 44,000 |
| 39 | Supply of PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection as per specification/ drawing/ description enclosed in this document. b. Supply of PBT terminal - 60mm centre | Numbers | 200.00 | 60 | 12,000 |
| 40 | Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection as per specification/ drawing/ description enclosed in this document: a. Supply of apparatus case - Full size | Numbers | 2.00 | 12,012 | 24,024 |
| 41 | Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection as per specification/ drawing/ description enclosed in this document: a. Supply of apparatus case - Full size b. Supply of apparatus case - Half size | Numbers | 2.00 | 8,580 | 17,160 |
| 42 | Supply of Electric key transmitter - rotary type of required ward Nos. with keys, with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 3.00 | 4,279 | 12,837 |
| 43 | Fixing of additional plug boards, 50 ways terminal blocks and wiring of additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall be provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board.(Supply of relays, plug boards, connectors and retaining clips and 50 way terminal boards is not covered in this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 25mm thick for fixing resistors and condensers, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and all other miscellaneous materials required for the work shall be supplied by the Contractor | Per Relay | 2.00 | 392.7 | 785.4 |
| 44 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. The work includes releasing the unwanted wires carefully without disturbing the existing wiring.[Wire PVC 16/0.2mm copper, soldering materials, bunching threads, condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per Relay | 35.00 | 376.04 | 13,161.4 |
| 45 | Installation of illuminated Diagram Board above the SM's control Instrument at Level Crossing gates, wiring the same including interconnections and painting. (Supply of Illuminated Diagram board is not included in this schedule). [Wire PVC 16/0.2mm copper, soldering materials, LEDs, resistances and all other required miscellaneous materials shall be supplied by the Contractor.]. | Numbers | 1.00 | 3,437.4 | 3,437.4 |
| 46 | Excavation of pit, concreting 'A' type foundation and fixing ground lever frames single/double as per Drg.No.SG/CN/02/11 complete with ground connection. The work includes concreting of 'A' type foundations and fixing of HP lock and connecting the ground lever frame with the HP lock using MS rod as instructed by Railway representative at site. (Supply of ground lever frames, hand plunger locks and 'A' type foundations is not covered in this schedule). [Cement, river sand, stone jelly of size 20/25mm, fixing bolts and nuts with washers and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 2.00 | 4,531.35 | 9,062.7 |
| 47 | Interlocking of level crossing gate with Lifting Barrier: This work consists cutting of notches on the drum of the winch, , fixing and levelling of trestles, rod roller assembly, levelling and concreting of 'A' type foundations, fixing of rod diversion cranks, vertical cranks, running of rods (app. 30mtrs.) and connecting them to lever tail at one end and boom locking arrangement at the other end, and painting as per standard practice. The work also includes fixing of wiring of one limit switch for each boom as per the instructions of Railway representative at site. (Supply of HP locks, rods, 'A' type foundations, trestles, segments, rod roller assembly complete and cranks is not covered in this schedule). [cement, river sand, stone jelly of size 20/25mm dia, coal bengal, paints, all types of bolts & nuts and all other miscellaneous materials shall be suuplied by the Contractor]. | Numbers | 2.00 | 12,370.05 | 24,740.1 |
| 48 | Fixing and wiring of Two Nos. of Electronic Gate Warning equipment for each level crossing gate, one on each road warning signal, amplifier in the apparatus case with wire PVC 3/0.75mm and 16/0.2mm copper, and painting. (Electronic Gate Warning Equipment and amplifier will be supplied by Railways). [All wiring, fixing and painting materials shall be supplied by Contractor]. | Set | 3.00 | 2,427.75 | 7,283.25 |
| 49 | Design, fabrication and supply of Gate Indication Panel of 16 SWG, powder coated MS sheet of size 450mm x 300mm x 100mm approximately consisting of different colour LEDs with holders suitable to work on 24VDC supply. Indications on the front panel shall be as per typical diagram supplied by Railways. All descriptions on the front panel have to be neatly painted. The Panel shall then be wired using wire PVC 16/0.2mm copper as per the approved circuit diagram and installed in the gate lodge as instructed by Railway representative at site. [All materials required for the work shall be supplied by the Contractor]. | Numbers | 1.00 | 7,843.5 | 7,843.5 |
| 50 | Fixing of EKT instrument with (or) without crank handle or on suitable fixtures at station/apparatus case, provision of economiser push switch with locking facility, wiring with wire PVC 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting. (Supply of electric key transmitter and crank handles is not covered in this schedule). [wire PVC 16/0.2mm copper, wire wound resistance, decolum covered terminal box with locking facility by using 25mm thick teakwood, bolts and nuts, paints, push switches, padlocks a n d other miscellaneous materials required for this work shall be supplied by the contractor]. | Numbers | 5.00 | 2,943.75 | 14,718.75 |
| 51 | Submission of all relevent final 'Asmades' of circuit diagrams, contact analysis charts, termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film' The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and Railways. On approval 8 copies shall be made for Asmade Circuit diagrams also as mentioned above. (The Rate is for per Sheet) | Sheet | 50.00 | 206.55 | 10,327.5 |
| 52 | Supply and provision of E type lock with key for fixing the same in LC/HP/FP Locks/SM slides and painting as per standard practice and instructions of Railway representative at site. (Supply of E type Locks, Keys, Paints, all types of screws, bolts & Nuts and all other miscellaneous materials shall be supplied by the Contractor). | Numbers | 5.00 | 1,266 | 6,330 |
| 53 | Releasing of existing apparatus cases (Full/ Half/ Quarter size) without damage after releasing t h e shelf planks, Terminal blocks, Fu s e Blocks, Terminal Boards, Relays of all types EKTs, Secondary Cells, power equipments, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked at a place as instructed by Railway representative at site. | Numbers | 8.00 | 1,625.25 | 13,002 |
| 54 | DISmantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling. Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Ro u t e Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The w o r k includes breaking the concrete foundation, closing the resultant p i t and resurfacing it by ramming and levelling. Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Ro u t e Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The w o r k includes breaking the concrete foundation, closing t h e resultant pit and resurfacing it by ramming and levelling. Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt sign | Numbers | 9.00 | 1,666.5 | 14,998.5 |
| 55 | Dismantling and releasing of ground lever frame along with all connected gadgets like lever locks, 'E' type locks, HP locks, etc., accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also involves breaking and removal of concrete foundation and the resultant pit shall be filled and consolidated by ramming and levelling. | Set | 2.00 | 3,000 | 6,000 |
| 56 | Releasing of point rods with rod roller trestles, complete assembly. This includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits are to be covered with earth and consolidated by ramming and levelling. a. Releasing of tressles 1/2 way | Numbers | 40.00 | 46.65 | 1,866 |
| 57 | Releasing of point rods with rod roller trestles, complete assembly. This includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits are to be covered with earth and consolidated by ramming and levelling. b. Releasing of tressles 3/4 way | Numbers | 40.00 | 63.3 | 2,532 |
| 58 | Releasing of point rods with rod roller trestles, complete assembly. This includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits are to be covered with earth and consolidated by ramming and levelling. c. Releasing of point roddings (The rate is for per Rod/Metre) | Metre | 120.00 | 7.95 | 954 |
| 59 | Releasing of point rods with rod roller trestles, complete assembly. This includes releasing of all cranks, compensators and 'A' type concrete foundation on the rod run. The resultant pits are to be covered with earth and consolidated by ramming and levelling. d. Releasing of 'A' type foundations | Numbers | 4.00 | 341.7 | 1,366.8 |
| 60 | Releasing of all the S & T gadgets at LC gates like SM slide instruments, illuminated diagram board, block counter, termination box, telephones, emergency key box, etc and concerned wiring, accounting and stacking them neatly at a place as instructed by Railway representative at site. After releasing any holes on the walls/ floor are to be filled with cement mortar and plastered. | Set | 2.00 | 5,166 | 10,332 |
| 61 | Transportation of Signalling materials by road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. a. Transportation upto 100 Kms. | MT-Km | 4500.00 | 12.3 | 55,350 |
| 62 | Transportation of Signalling materials by road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. b. Transportation more than 100 Kms. | MT-Km 13000.00 | — | 7.52 | 97,760 |
| Schedule total | ₹12,07,147.01 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .