Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹31.1 L+₹1.1 L (3.77%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
₹31.3 L
EMD Value
₹62,600
Closing Date
28 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Faridkot
Garrison Engineer, Faridkot-151203 Punjab 01639-264982
Provn of Certain Revenue and Minor Works under AGE E/M at Faridkot Mil Stn
2021_MES_464152_1
GE FRD-41/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Faridkot Mil Stn
Class D Category b i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹62,600
Yes
10 Sept 2021
31 Jul 2021
30 Aug 2021
31 Jul 2021
28 Aug 2021
14 Aug 2021
60 days
Amount
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid concealed conduit of suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 2.8mm thick plastic laminate Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primer including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated, stranded (Green colour) connected to common earth point dolly for for one light point/fan point/call bell point, 230 volts controlled by one switch complete all as specified and directed .
All as per Ser item No 01 here-in-before but for switch socket combination 5 Amp 5 Pin socket outlet 230 volts on independent board complete all as specified and directed .
All as per Srl item No. 01 here-in-before for Switch socket combination (multi purpose) 6 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5Sqmm FRLS PVC unsheathed copper conductor and FRLS cable 2.5 Sqmm PVC insulated earth wire on independent board.complete all as specified and directed
S&F switch piano, flush type, single pole, one way, 5 /6 Amp,230 V,AC supply complete all as specified and directed .
S&F socket outlet, two in one, 5 Pin 5 Amps, 230 Volt, AC supply, complete all as specified and directed .
S&F ceiling rose, three terminals, PVC polycarbonate, isolated body with bakalite 20mm back plate complete all as specified and directed .
Supply, installation, testing and commissioning of desert cooler electric driven (single phase) having nominal air flow capacity of 6000 CuM Per hour (or nearest size) in steel body made out of hot dip galvanised steel plain sheet thickness 1mm body and 1mm thick removable sides and back panels, single phase 230 volts of exhaust fan size 450mm sweep with submersible pump of suitable size / capacity (ISI marked) (maximum power consumption 250 Volts), PVC grills, conecting copper cable with three pin top, length not less than 2.0 m, PVC connecting pipe of suitable length, BEE approved, conforming to trade pattern including 15mm bore float valve & PVC connection, leakage proof joints complete all as specified and directred
Supply and laying mild steel water tubing, medium grade, galvanised ,of size 15mm bore with all fittings and laid in trenches/ under floor/ road or on wall complete all as specified and directed .
S&F Stop valve, cast copper alloy, chromium plated,screwed down for high pressure with crutch or butter fly handle, screwed both ends for iron pipe of 15mm bore complete all as specified and directed .
Supply and laying mild steel water tubing, medium grade, galvanised ,of size 25mm bore with all fittings and laid in trenches/ under floor/ road or on wall complete all as specified and directed .
S&F Stop valve, cast copper alloy, chromium plated,screwed down for high pressure with crutch or butter fly handle, screwed both ends for iron pipe of 25mm bore complete all as specified and directed .
Supply and laying mild steel water tubing, light grade, galvanised ,of size 40mm bore with all fittings and laid in trenches/ under floor/ road or on wall complete all as specified and directed .
Supplying and fixing mild steel framed work for desert cooler stand (to be fixed in multistory buildings) made out of angle iron of size 40x40x5mm cross bracings, stiffeners, supports, clamps and back plates, clamps, fabricated from structural steel sections including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed
S&F Gun Metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed 25mm dia of pipe complete all as specified and directed .
S & F exhaust fan 300mm sweep, steel body 1380 RPM (Trans air 3 blade) 70 watt, with louver shutter suitable for operation on 220/230 volts, single phase, AC all fixing arrangements like wall hole etc and complete all as specified & directed
S&F Sub main wiring with two runs of single core PVC FRLS sheathed, insulated, copper cable of 4Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 4Sqmm for continous earth wire drawn into and including concealed conduit of suitable size complete all as specified and directed . Note :- Two runs of 4 Sqmm copper cable and one run of 4 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
Supply, fixing & hanging Energy efficient Ceiling fan (white colour) 1400mm sweep BEE approved 5 star rating, AC single phase, 230V, including canopies, three Nos. blades, down rod, double ball bearing with capacitor 2.5 mfd and making connection with and including PVC insulated PVC sheathed copper conductor flexible cable 3 core of suitable size from ceiling rose or connector to fan complete all as specified and directed
Supply, install and commissioning of hi wall-split type AC Heating and Cooling type indoor, outdoor type with cord less remote control unit and with in built air ioniser and plasma filter for better indoor air quality,digital inverter twin rotary 2.0 TR capacity with single evaporator unit wall mounted condenser unit and with compressor non ductable corded type suitable for operation on 230 V, 50 Hz single phase electric supply including set of bracket for fixing of outdoor unit and fixing the evaporator inside the bldg with suitable insulation including provn of copper refg piping of suitable length from condensing to cooling coil & vice versa duly overlapped by nitrile insulation & suitable drain pipe for dropping out the water outside from evaporator duly elect connection with 3 core copper cable of suitablesize making good to disturbed surface complete all as specified and directed .
S&F voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 volt with accurcy of + 2.5% and of capacity 5 KVA with wall mounting bracket complete all as specified and directed .
Writing MES Nos (Black, Roman, Italic or indian) n.exc 30cm height complete all as specified and directed
S&F Sub main wiring with two runs of single core PVC FRLS sheathed, insulated, copper cable of 6Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 6Sqmm for continous earth wire drawn into and including concealed conduit of suitable size complete all as specified and directed . Note :- Two runs of 6 Sqmm copper cable and one run of 6 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
S&F Sheet Metal Enclosures Plug metal clad SP & N with a 2 pin earth plug and socket with MCB SP 20 Amps suitable for working on 230 volts AC complete all as specified & directed.
S&F MCB SP&N, 240 volt 10 KA, 'C' Curve, 32 Amp complete all as specified and directed .
Supply, install and commissioning of hi wall-split type AC Heating and Cooling type indoor, outdoor type with cord less remote control unit and with in built air ioniser and plasma filter for better indoor air quality,digital inverter twin rotary 1.5 TR capacity with single evaporator unit wall mounted condenser unit and with compressor non ductable corded type suitable for operation on 230 V, 50 Hz single phase electric supply including set of bracket for fixing of outdoor unit and fixing the evaporator inside the bldg with suitable insulation including provn of copper refg piping of suitable length from condensing to cooling coil & vice versa duly overlapped by nitrile insulation & suitable drain pipe for dropping out the water outside from evaporator duly elect connection with 3 core copper cable of suitablesize making good to disturbed surface complete all as specified and directed .
Supply, installation, commissioning and testing battery,12 Volts capacity, 65AH Power safe, sealed battery for UPS, Solar complete with terminal both side for connection and copper cable of suitable size for making electric connections complete all as specified and directed.
Supply, installation, commissioning and testing water storage heater (geyser) vertical type of 25 ltr capacity, ultathick stainless steel superior 304 Gde PUF insulation thermostate, thermal cut off, 1PX4 multifunctional safety valve technology, feroglas dry powder coating finish, suitable for to operate / function on AC 220 V, single phase having heating element of 2 KW capacity and high thermal cut-out, energy saving BEE 5 star rating including fixed along walls including grouting fastening & fixing (04 Nos) 16mm dia 150mm long GI bolts & nuts, washers and connecting up inlet/ outlet with cold water PVC connection pipes and electric connections cable cord min 1.50m length with copper conductor cable 3 core and 3 pin plug 15/16 Amp, including making good the disturbed surfaces matching with existing complete all as specified and directed
S&F of air termination rod ,12 mm dia, single pointed 300 mm long along with base plate welded at bottom of termination rod,of size 10 cm long fabricated out 25x3 mm thick aluminium strip along with making 9 mm dia for fixing in fastners (wooden block) complete all as specified and directed
M&L for aluminium strip 25mmx3.15mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed
Material & labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6mm galvanised iron strip complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of galvanised iron strip 3mmx6mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 40mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 1500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions.
M&L for test points terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos, 8mm dia, 25 mm long hexagonal screw complete all as specified and directed .
Supply and fix porcelain insulator 11000 volts grade, of size 150mm height and 150mm dia for isolation of conductor from the building wall by provviding 15cm long fastner at every 16cm distance in the wall complete all as specified and directed .
M & L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in Block of size 25 cm x 25cm and height 30cm, providing 02 Nos. MS fastner at the top of the block by using 8/9mm dia 20cm long bolts with T junction of 10cm & embeded in the PCC block, keeping 7 cm portion of the bolt above the upper surface of PCC block alongwith 02 Nos washers and nuts etc complete all as specified and directed
S&F wooden block of locally available 2nd class hard wood of size 25 x 10 x 5cm for mounted on top of PCC block for errection of air termination alongwith bolts and nuts and run the roof conductor complete all as specified and directed.
M/S BSS AND SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .