Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹32.0 L+₹1.6 L (5.10%)Rejected-AOC | L2 | Rejected-AOC Bidder quoted L2 rates |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
28 Nov 2019, 6:00 pmClosed
GE SOUTH PUNE
No 1 General Bhagat Marg Pune 411040
8818 PROVN OF CERTAIN LOW BUDGETED WORKS, REVENUE WORK, MINOR WORK AND SPECIAL REPAIRS TO EMERGENCY ROOM IN BLDG No. NP-94 AT MHCTC UNDER AGE BR I SOUTH PUNE
2019_MES_290469_1
8818 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
123 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹58,000
Yes
1 Jan 2020
17 Oct 2019
29 Nov 2019
17 Oct 2019
28 Nov 2019
4 Nov 2019
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises as directed.
Demolition of brick work or stone/boulders masonry built in Cement Mortar complete all as specified and as directed.
M & L for 25 mm thick PCC (1:2:4) type B0) (12.5mm graded stone aggregate) as in leveling course of floor tiles etc complete all as specified and directed by Engineer-in-Charge.
M&L Vetrified ceramic tiles degital printed 10mm thick light shade 1200x600mm in floor set an jointed in neat cement slurry and pointed in white or coloured cement to match including laid over 20 mm thick screed bed in CM (1:6).
M&Lglazed coloured digital printed ceramic tiles of size 600mmx300mmx7mm thick in vertical surfaceses etc set qnd jointed in neat cement slurry and pointed in coloured cement to match with colour tiles including 10mm thick backing coat in CM (1:4) and filleting at top etc complete.
Material and labour for complete removal of existing old plastered surfaces of walls and applying two coats of OBD over a coat of alkali resistant priming coat & smooth surface with internal 1mm thick wall care putty. Make : Nerolac/Jenson & Nicholson/Asian Paints
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified & directed by Engr-in-Charge.
M&L for coloured ceramic tiles 7 to 8 mm thick 600 x 600mm size of approved colour, set, jointed in cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 20 mm thick screed bed in CM 1:6 etc complete as in flooring all as specified and directed.
M&Lglazed coloured digital printed ceramic tiles of size 300mmx450mmx7mm thick in vertical surfaceses etc set qnd jointed in neat cement slurry and pointed in coloured cement to match with colour tiles including 10mm thick backing coat in CM (1:4) and filleting at top etc complete.
M&L for 12mm thick rendering on PCC / concrete block wall surfaces in CM 1:6 finished with sagol finish to plastered surface etc. complete all as specified and as directed.
M&L for providing and fixing CP toilet fitting in repairs as specified and as directed by the Engr -in-Charge for the following:-.
Bib Cock CAT No. CON- 037KN
Soap dish CAT No. ACN-1131 N
Towel ring square CAT No. ACN 1121 N
Coat hook CAT No. ACN 1191 N
Single Towel rail 600mm long CAT No. ACN 1111 NM
Angular stop cock conforming to CAT No. 053 KN of "Jaquar" or of equivalent make specified here-in-after.
CP 15mm bore concealed stop cock regular body conforming to CAT No. CON-083KN of "Jaquar" or of Equivalent make specified here in after
Wall mixer 3-in-1 including shower for 15mm bore of pipe conforming to CAT No. CON-7267KN of "Jaquar" or of Equivalent make specified here in after
S&F 2 way bib cock with wall flange complete all as specified and as directed.
M&L for gun metal globe valve with iron wheel fixed for 20mm bore pipe complete all as specified and as directed.
M&L for ball valve brass with polythelene float and fly nut fixed complete for 20 mm bore of pipe complete all as specified and as directed.
S&F oval shaped coloured vitreous china WHB of overall 600mm size including 32mm CP waste coupling, PVC waste pipe etc complete including Pillar cock long neck with aerator CAT No CON -021KN (Make - Jquar) directed by Engr-in-Charge.
M&L for PVC connection 15 mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S & F in repairs, vitreous china wash down water closet pan (pedestal pattern), white, 'P' or 'S' type, inc. 10 litres, PVC flushing cistern, L L, white, with inlet,ball valve, float & brackets, inc. flush pipe, PVC tube 32mm dia. & inc. plastic water closet seat, black, closed pattern with flat bottem, & cover & M S CP or aluminium hinging device complete all as specified and as directed.
M&L for PVC floor trap 100mm including jointing with CM 1:4 75mm dia complete all as specified and as directed.
M&L for Grating doom 100mm dia PTMT complete all as specified and as directed.
S&F PVC door frame of size 50x47mm made out of 5mm thick prelaminated PVC sheet reinforced with mild steel sq tube complete all as specified and as directed.
S & F Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and as directed.
S & F factory solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face supplying & fixing in frame at site as per specification & drawing complete given on Sl Page No. 161 of SSR Part-II 2010 as specified and directed by Engr-in-Charge.
M&L for mild steel electroplated butt hinges 100mm medium weight complete all as specified and as directed.
S&F 300mm long MS sliding door bolts, plate type stove enamelled black, with bright bolt not less than 12mm dia with & including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate.
M&L for mild steel tower bolts 150mm long complete all as specified and as directed.
M&L for mild steel powder coated handles 150mm complete all as specified and as directed.
M&L for preparation of wall/ ceiling surfaces and applying two coats of oil bound distemper over a coat of alkali resistance primer incl preparation of surface complete all as specified and as directed.
M & L for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top )hoisted and fixed in position with all fittings and fixture all as specified in SSR Part 1 capacity 1000 litres incl PTMT float valve with PVC ball 20mm bore of pipe complete all as specified and as directed.
M & L for PCC 1;3;6, type C2 75mm thick fair finished surfaces .as in plinth protection/ foot path complete all as specified and as directed.
S & F fixed glass ventilators using 5mm thick plain glass and following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make and rubber beading etc all as directed :- (a) SP 20048 (b) Glazing clips 19352
S&F MS framed work such as grills with ends of bars shouldered or riveted, or forged into spikes, framed guard bars or similar work using steel section conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed.
M&L for preparation of surfaces with Two coat of cement based paint over a coat of cement based primer complete all as specified and as directed.
S & F GI tubing and connections complete fixed to walls for the following sizes :-
15mm bore
20 mm bore
S&F PVC (SWR) pipes single socketed in any length 110 mm dia complete all as specified and as directed>
S&F PVC (SWR) pipes single socketed in any length 75mm dia complete all as specified and as directed.
S&F PVC (SWR) bend/L bow 110 mm dia complete all as specified and as directed.
S&F PVC (SWR) bend/L bow 75mm dia complete all as specified and as directed.
S&F PVC SWR branch piece, (Double 'Y') equal or unequal of 110 mm bore complete all as specified and directed
S&F PVC (SWR) vent cowl 75 mm dia complete all as specified and as directed.
Preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for 18 to 20mm thick Granite slab of approved colour work laying in design pattern using approved colour granite slab strips all as directed by Engr-in-Charge, laid bedded & jointed in neat cement slurry and pointed in white/coloured cement to match the shade of slab, laid over and including 20mm thick screed bed in CM ( 1:6) including rubbing and polishing complete in floors all as spcecified and directed.
Labour only for full round moulding to 18 to 20mm thick granite slab all as directed by Engineer-in-Charge.
S & F Machine cut cuddappa stone slab 20 to 25 mm thick for making cooking platform etc. complete all as spcecified and directed.
S&F three track sliding window with two or more shutter with 4mm thick tinted glass one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge. (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
M & L for Water proofing treatment to RCC roof slab shall be carried out as specified below and as directed by Engineer-in-Charge .(a) M&L for 10mm thick screed bed in cement mortar 1:3 on concrete surfaces of roof slab and parapets mixed with WPC @ 3% by weight of cement finished even and smooth without using extra cement (b) The roof surface shall be thoroughly wire brushed, cleaned to eleminate all sharp projection washed dried up and cleaned of all foreign matter and dust to receive premier.(c) Laying APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.5 Kg/Sqm with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of GE.(d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified & as directed by Engr in Charge.(e) The overlap while Torching shall be 100 mm on length side and 100 mm on width side of membrane.(f) The treatment shall be carried as per manufacturer instructions.Note:- The contractor shall furnish the following :- I) Quality confirmation from the manufacturer of the product alongwith quantity supplied.ii) Manufacturer test certificate.iii) The result if tested any of the independent laboratory, the testing charges shall however be borne by the Contractor.
S&F aluminium powder coated double leaf door on pivots alongwith hydraulic door closer, door lock, handles, 10mm thick glass fixed with rubber beading and glazing clips and using following sections of `Jindal Aluminum Ltd ' or equivalent in Ajit India Pvt Ltd or Crystal Bombay, as approved all as directed by Engineer-in-Charge a) Rectangular tube 14005 b) Shutter vertical 19501 c) Shutter top rail 19503 d) Shutter Middle rail 20060 e) Shutter Bottom rail 19511 f) Glazing clips 19352
S&F aluminium powder coated partition using following sections of `Jindal Aluminum Ltd ' or equivalent in Ajit India Pvt Ltd or Crystal Bombay, as approved with 12 mm thick both side prelaminated particle board interior grade of approved colour in bottom panel and 5mm thick plain glass in top panel fixed with aluminium clips, beads, rubber gaskets etc., centre to centre distance of vertical member shall not exceeding 1mtr and horizontal member shall not exceeding 1.10 mtr using following aluminum section as specified in Jindal Catalogue complete as directed fixing to stone masonary walls with & including Ist class teak wood plugs of size 20mmX20mm at an interval of 0.5m alround the track including drilling holes. (a) SP – 20048 (b) DP - 20047 (c) Glazing clips - 19352
Surface excavation not exc 30 cm deep and averaging 15 cm and getting out hard dense soil complete all as specified and as directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation in hard /dense soil complete all as specified and as directed
Excavation over areas n.exc. 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation over areas n.exc. 1.5 m deep and getting out in hard rock complete all as specified and as directed.
Excavation over areas exc. 1.5 m but n.exc. 3.00 mtr deep and getting out in hard rock complete all as specified and as directed.
M&L for PCC in foundation in 1:4:8 type D2 (40mm garded agg) in foundation filling and mass concrete complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removal of excavated material not exc 50M and deposited where directed at a level n.exc 1.5M above from starting point complete all as specified and as directed.
Removing excavated surplus rock not exceeding 50mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed by Engr-in-Charge.
Filling under floor with moorum laid in layers n.exc 15 cm thick spread ,levelled and rammed , watering and compacted complete all as specified and as directed.
M&L for RCC (1:1.5:3) type A1 ( using 20mm graded stone aggregate ) as in foundation and plinth beams complete all as specified and as directed.
M&L for RCC (1:1.5:3) type A1 ( using 20mm graded stone aggregate ) as in columns complete all as specified and as directed.
M&L for RCC (1:1.5:3) type A1 ( using 20mm graded stone aggregate ) as in beams complete all as specified and as directed.
M&L for RCC (1:1.5:3) type A1 ( using 20mm graded stone aggregate ) as in slabs complete all as specified and as directed.
M&L for RCC (1:1.5:3) type A1 ( using 20mm graded stone aggregate ) as fins, facias etc complete all as specified and as directed.
M&L for use and waste of form work to sides of foundation, footing & plinth beams rough finished surfaces complete all as specified and as directed.
M&L for use and waste of form work to sides of columns fair finished surfaces complete all as specified and as directed.
M&L for use and waste of form work to sides and soffits of beams rough finished surfaces complete all as specified and as directed.
M&L for use and waste of form work to soffits of slab n.exc 200 mm thick rough finished surfaces complete all as specified and as directed.
M&L for use and waste of form work to edges of concrete flat n.exc 20 cm wide rough finished surfaces complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over in reinforcement including cutting bending and binding with mild steel wire annealed not less than 0.9 mm dia complete all as specified and as directed.
M&L for mild steel TMT bars 6 to 8 mm dia and over in reinforcement including cutting bending and binding with mild steel wire annealed not less than 0.9 mm dia complete all as specified.
M&L for mild steel TMT bars 5mm dia and over upto and incl 10mm dia in stirrups/spacers, including cutting bending and binding with mild steel wire annealed not less than 0.9 mm dia complete all as specified
M&L for Rendering 5mm thick in cement mortar (1:4), with using WPC, over and including 10mm thick dubbing coat on fair faces of brick work in cement plaster (1:4) (external wall) complete all as specified.
M&L for Rendering 10 mm thick in cement mortar (1:4) on concrete surfaces with WPC, over roof slabs & chajjas top complete all as specified and as directed. (Note:- WPC will be measured and paid for seperately)
M&L cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) 75 mm thick as in sub base floor complete all as specified and as directed.
M&L joint free non skid ceramic coloured tiles mat finish (600x600mm)x7mm thick in floors etc incl 15 mm thick cement screed in cm 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed.
M&L for preparation of surfaces and applying two coats of weather proof exterior emulsion complete all as specified and as directed.
S&F in repairs vitreous china, squatting pan, 'Orissa' pattern, size 580 x 440mm white, with integral foot rest, including concrete bedding and PVC flushing cistern 10 Ltr capacity including all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed.
S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs,hinges,lock strike plate etc complete, supplied and fixed ,size 125x60. (Ref Anant industries) complete all as specified and as directed.
S&F 35mm thick flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed
S&F Factoy made skeleton shutters of 35mm thick prepared to receive glass/gauge etc. with sash bars edges of frameing plain, chamered or rounded, fitted with cut and mitred beads for securing glass etc. complete all as specified and as directed.
M&L for Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and averaging width of aperture 1.00 mm complete all as specified and as directed.
M & L for 1 mm thick wall care putty incl preparation of surface complete all as specified and as directed.
Preparing newly surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
M&L preparation of wood surfaces and applying 2 coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for hardcore filling ,not exc 63 mm, spread levelled blinded and consolidated complete all as specified and as directed.
S & F brass powder coated golden matt finished curtain rod 25mm bore, fancy type all specified & directed by Engineer-in-Charge.
S & F curtain rod bracket brass powder coated with goldern matt finished decorative type suitable for 25mm bore pipe all as specified & directed by Engr-in-Charge.
M&L for precast coloured, chequered cement concrete tiles, glossy finish of size 305 x 305mm x 25mm thick, conforming to IS-1237 (2006) set jointed and pointed in neat cement slurry in floor laid over and including 20mm thick screed bed in CM (1:6) complete all as specified and as directed.
Rendering 10mm thick in CM 1:6, on brick/ PCC block walling, finished even & smooth with a thin layer of sagol finish complete all as specified and as directed.
M&L for vitrified coloured ceramic tiles 7 to 8 mm thick 600 x 600 mm size of approved colour, set, jointed in cement slurry & pointed in white or colour cement to match the shade of tiles, laid over & including 20mm thick screed bed in CM 1:6 etc complete as in flooring all as specified and as directed by Engr-in-Charge.
S&F unplasticised PVC pipe 20mm dia with fittings & all connections complete fixed to walls, ceilings etc. complete all as specified and as directed.
S&F unplasticised PVC pipe 25mm dia with fittings & all connections complete fixed to walls, ceilings etc. complete all as specified and as directed.
M&L RCC pipes class NP-2 with socketed ends laid and jointed complete of 150mm bore complete all as specified and as directed
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate as in bed to drain pipes including forming cradles for 250mm RCC hume pipe complete all as specified and as directed.
M & L for precast cement concrete 1:2:4 type B-1 using 20 mm graded stone agg for cover slab of manholes set in cement mortar 1:4 complete all as specified and as directed.
M & L for PCC 1:2:4, type B-1 using 20 mm graded stone agg as in benching of manholes complete all as specified and as directed.
Extra for forming fair finished drain or channels 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred / stopped ends etc in manholes (inner girth only measured)
Rendering 15mm thick in cement mortar 1:4 on brick/concrete surfaces using water proofing compound as per manufacturers instructions surface finished with sponge finish. (Note : WPC shall be measured and paid separately)
Supply only integral water proofing compound.
M&L for Point wiring any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed stranded cable 1100 volts grade, (FR) ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes with earth dolly duly concealed in wall, painted with two coats of anti corrosive paint over a coat of red oxide primer, internally, covered with plastic laminated sheet suitable for switches, including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly, complete all as specified for the following:-
One light/fan point controlled by one switch and regulator
Socket outlet, three pin, 5 Amp, independent
Socket outlet, three pin 5 Amps on the same board
Bell/Buzzer points controlled by one bell push.
All as per Item No 99.00 above but ,with stranded copper conductor 2.5 Sq. mm (nominal area), including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed.
M&L for Point wiring any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed stranded cable 1100 volts grade, (FR) ISI-694 marked in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes with earth dolly duly concealed in wall, painted with two coats of anti corrosive paint over a coat of red oxide primer, internally, covered with plastic laminated sheet suitable for switches, including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly, complete all as specified for the following:-
One light/fan point controlled by one switch and regulator
Socket outlet, three pin, 5 Amp, independent
Socket outlet, three pin 5 Amps on the same board
Bell/Buzzer points controlled by one bell push.
S&F Ceiling rose, surface Bakelite suitable for 3 pin 230 volt 50 Hz AC supply complete all as specified and as directed.
S&F Switch piano; flush type, single pole, one way, and 6 Amp, 230 volt complete all as specified and as directed.
S&F Switch piano; flush type, single pole, one way, and 15 Amp, 230 volt complete all as specified and as directed.
S&F Bell push 6 amp 230 volt 50 HZ AC supply complete all as specified and as directed.
S&F Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type complete all as specified and as directed
S&F socket outlet multipurpose having provision for 3 pin, 15 Amp and 3 pin, 5 Amp, piano flush type complete all as specified and as directed.
Supply and fix step fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
Supply and fix bell electric Ding dong suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
Supply and fix surface wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver for LED tube complete with retrofit LED energy saving recess/surface mounted luminaries, high efficiency diffuser for soft glare fee light of capacity 20 watt suitabe of operation on 230 volt 50 Hz AC supply conforming to Cat Part No ENDURALINEARNEOBS20WLED865SPCWH of Havells or equivalent model in Wipro/HPL/Philips complete all as specified and as directed by Engineer-in-charge.
Supply and fix lamp holder PVC insulated body with back plate suitable for batten complete for 230 volt 50 Hz AC supply complete all as specified and as directed.
Supply and fix Street light LED fittings Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP 65 Proptection and necessary fixing arrengements i.e pipe mounting GI bracket bent in shape not exceeding 1.5 mtr in length made out of 40 mm dia GI pipe conforming to Cat Part No. of Havells ENDURACITYLITEPLATSL20WLED757SASYBOPC or same type in all respect of Wipro/Bajajcomplete all as specified and directed by Engineer-in-charge.
Supply and fix Ceiling fan 1200 mm sweep, 5 star rated and ISI marked suitable for operatrion on 230 volt 50 Hz AC supply complete with electronic type fan regulator and accessories complete all as specified and as directed
Supply and fix exhaust fan AC single phase 230/ 240 volts heavy duty of size 300 mm sweep, 1400 rpm, with louvers and all fixing arrangements such as plywood 18mm thick of suitable size complete all as specified and directed.
Excavation in trenches n.exc 1.5mtr wide and n.exc. 1.5m in depth for foundation and getting out in soft/loose soil complete all as specified and as directed
M&L for Reinforced concrete pipes,class NP2 with one collar per lengh of pipe of dia 150 mm ,half round (02 Nos for top & bottom) as specified by Engr-in-charge.
Supply, lay, test connecting and commissioning underground stranded aluminium conductor cable LT 1100 volt grade heavy duty XLPE insulated armoured complete laid in trenches/fixed to poles /drawn through pipes with suitable size cable glands crimping type cable lugs etc all as specified and directed of size 16 Sqmm 2 core including takind down old unserviceable cable complete all as specified and as directed.
S&F sheet metal enclosures for DB's when MCB,s to be used double door 8 way 240 volts complete all as specified and as directed.
Supply and fixing of MCB Single pole and neutral rated capacity 32 A, 240 V breaking capacity 9KA 'C' series complete all as specified and as directed.
Supply and fixing of MCB Single pole rated capacity 5 to 32 A, 240 V breaking capacity 9KA 'C' series complete all as specified and as directed.
M&L for earthing complete with galvanized steel plate electrode 60 cm x 60 cm x 6 mm surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25 meter below ground level with top edge of the earth plate at a depth of not less than 1.50 meter below ground level connected to galvanized iron or steel earth wire, 4 mm dia (No. 8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron, earth wire protected by galvanized steel pipe 15 mm dia (Light grade) & connected to main switch or main control board all as shown in electrical plate No. 3 of SSR-2009 Part I & including necessary excavation and earth work. The rate also include charcoal and salt in alternate layers 20 mm dia pipe (Light grade) for watering, protection pipe, funnel, wire mesh, PCC chamber in cement concrete (1:3:6) type C-I, 40 mm thick RCC (1:2:4) type B-1 cover and CI frame etc.
Supply & lay, Galvanized steel water tubing, 40mm bore medium grade, including provision of specials such as bends, elbows, tees, unions etc laid in trenches complete all as specified and directed.
Supply and fix in repairs gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 40 mm bore complete all as specified and as directed.
Cutting existing steel tubing size 80mm bore for insertion of tee 80x80x40 mm including necessary joints for branch connection complete all as specified and as directed.
Taking down carefully aluminium point wiring (light, fan, socket or power), complete, (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor to match with existing surface etc.
Taking down ceiling fan of any size/sweep after disconnecting the wire from existing ceiling rose and refixing the same after cleaning dust, oiling greasing etc including providing flexible three core from ceiling rose to connector of fan
S & F Sheet metal, 20 amp Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps, 10 KA breaking capacity,'C' series, 240 V complete all as specified and as directed.
M&L for sub main wiring with approved colour coding as per IS with two single core PVC insulated cable with stranded copper conductor of size 6 Sqmm nominal area and drawing , in PVC conduit including PVC insulated 4 Sqmm (nominal area) stranded copper conductor earth wire complete all as specified and as directe. (NOTE: - Two runs of 6 sqmm cable, one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit)
M&L for taking down existing FTL rod 36/40 watt and supply and fix surface wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver for LED tube complete with retrofit LED energy saving recess/surface mounted luminaries, high efficiency diffuser for soft glare fee light of capacity 20 watt suitabe of operation on 230 volt 50 Hz AC supply conforming to Cat Part No ENDURALINEARNEOBS20WLED865SPCWH of Havells or equivalent model in Wipro/HPL/Philips complete all as specified and as directed by Engineer-in-charge.
S&F vertical 4 way TPN double door,recess mounted/wall mounted,MCCBs as incomer is 3 pole V-Tec of 100A rating & 16KA breaking capacity,MCCB is pre-fitted at factory & including price of MCCB,all as directed and specified by Engineer in charge.
Supply and fixing DB 12 way SPN with 200 amps rated bus bar, double door complete all as specified and as directed.
Supply and fix MCB DB 240 volt, 4 way SPN suitable for 230 volt 50 HZ AC supply complete all as specified and as directed.
Supply and fix decorative box type fittings with colour end caps and prewired for LED tube complete with retrofit LED energy saving recess/surface mounted luminaries, high efficiency PMMA diffuser for soft glare free light of capacity 24 watt suitable for operation on 230 volt 50 Hz AC supply complete all as specified and as directed by Engineer-in-charge. (Make- Crompton Cat Nos - DMLN1LT8-16 AND LED LTT8-20 or same type in Wipro/Philips)
M&L for point wiring with stranded copper conductor 2.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed stranded cable 1100 Volt grade (FR) ISI-694 marked for 3 pin, 15 Amp socket outlet, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed.
M&L for sub main wiring complete with two single core 4 sqmm 1100 volt grade PVC insulated, unsheathed multistranded copper conductor (FRLS) cable including PVC casing & caping and accessories, including continuous PVC insulated copper earth conductor 2.5 sqmm complete all as directed. (Note : 2 runs of 4 sqmm cable and 1 run of 2.5 sqmm earth wire and 1 run of PVC casing caping shall be measured as one length.)
M&L for cutting and making hole into or through cement concrete or stone masonry wall of thickness upto 45cm and in girth n.exc. 45cm for fixing exhaust fan of size 300mm sweep & providing fastners grouted in wall four nos inside for fixing of Exhaust fan and four nos outside for louvers and redressing the surface and making smooth with cement plaster 1:4 to match existing surface incl lime white wash all as specified and directed.
Aishwarya Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .