Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.3 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹74.2 L+₹2.0 L (2.71%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹77.0 L+₹4.7 L (6.51%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹77.1 L+₹4.9 L (6.75%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹78.2 L+₹5.9 L (8.18%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
22 Mar 2021, 6:00 pmClosed
CHIEF ENGINEER R AND D, PICKET, SECUNDERABAD-50000
CHIEF ENGINEER R AND D, PICKET, SECUNDERABAD-500003
SPECIAL REPAIRS TO D TYPE AND J TYPE QUARTERS IN ALISDA RESIDENTIAL AREA, BENGALURU
2021_MES_414929_1
CA NO.CERD/BAN/TOKEN/20 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
Bangalore
As per NIT
7 documents required · 7 mandatory
₹1,000
GE I R AND D WEST BANGALORE
₹1.3 L
Yes
19 May 2021
21 Jan 2021
29 Mar 2021
21 Jan 2021
22 Mar 2021
8 Mar 2021
Amount
Taking down shutters of any description exceeding 1.0sq.m but not exceeding 2.0sq.m and removing from site, complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5sq.m each (without taking off shutters from the frames), complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5sq.m not exceeding 4sq.m each (without taking off shutters from the frames), complete all as specified and directed.
Second class hard wood plain, framed, panelled shutters (two number of panels), 35mm thick, factory made, with lock rail and panels of 9mm thick BWP commerical ply or 12mm thick veneered particle board medium density with commercial veneering on both faces : supplied and fitted to chowkats; The size of rail and styles shall be all as per IS : 1003 (Part - I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
Second class hard wood Glazed and skeleton shutters, 35mm thick, factory made, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification, complete all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification, complete all as specified and directed.
Taking down, easing, adjusting and refixing builders hardware as required including renewal of unserviceable screws etc., and refixing in the same opening after laying of tiles, shutters of any description exceeding 1.0 sq.m but not exceeding 2.0 sq.m each, complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, fixed in repairs, complete all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section and fixed, 150mm long, complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, 300mm long, complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, 250mm long, complete all as specified and directed.
Butt hinges, medium weight, 100mm long, cold rolled mild steel, and fixed, complete all as specified and directed.
Aluminium handles, cast type, anodised, oval shaped, 150mm long, complete all as specified and directed.
Mild steel, 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete fixed to steel/wooden shutters with FI 40mm x 3mm and 300mm long with necessary bolts, fixed in repairs, complete all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate shall be 140mm long, complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails, complete all as specified and directed.
Plywood, 12mm thick, grade BWR, type BB, fixed with screws to timber frame work, as in cupboards / shelves, complete all as specified and directed.
Decorative laminate type 1, 0.90mm thick, of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions, complete all as specified and directed.
External teak wood lipping, 6mm thick, fixed to 12mm thick plywood, fixed with nails, complete all as specified and directed.
Aluminium handles, cast type, anodised, 75mm long, complete all as specified and directed.
Magnetic kitchen cabinet door catch, complete all as specified and directed.
Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) shall be 40mm, complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n exc 15 em thickness (below or above ground level), complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Taking down cement plaster (backing coat) any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc., to receive plaster, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar,complete all as specified and directed.
Plain cement concrete (1:2:4) type B0 (using12.50mm graded stone aggregate) 25mm thick as in sub base for laying floor finishes, complete all as specified and directed.
Non-skid ceramic coloured joint free tiles of size 600 x 600 x 10 mm thick (Minimum), as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including provision of screed bed 15mm thick in CM (1:4), complete all as specified and directed.
Non-skid ceramic coloured joint free tiles of size 600 x 600 x 10 mm thick (Minimum), as in vertical surfaces like skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including provision of backing coat 10mm thick in CM (1:3), complete all as specified and directed.
Non-skid ceramic coloured joint free tiles of size 400 x 400 x 8 to 9 mm thick (Minimum), as in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including provision of screed bed 15mm thick in CM (1:4), complete all as specified and directed.
Non-skid ceramic coloured joint free tiles of size 400 x 400 x 8 to 9 mm thick (Minimum), as in vertical surfaces like skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including provision of backing coat 10mm thick in CM (1:3), complete all as specified and directed.
Glazed ceramic tiles in vertical surfaces such as skirtings / dado etc., 450 mm x 300 mm x 7 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including provision of backing coat 10mm thick in CM (1:4), complete all as specified and directed.
Machine cut kota stone slab of size 550 x 550 x 22-25mm thick as in flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, laid over and including provision of screed bed 15mm thick in CM (1:4), complete all as specified and directed.
Machine cut kota stone slab of 22-25mm thick as in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, laid over and including provision of backing coat 10mm thick in CM (1:3), complete all as specified and directed.
Granite (of any type) work (table rubbed and polished), 20mm thick as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including provision of screed bed 15mm thick in CM (1:4), complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations, complete all as specified and directed.
Powder coated aluminium (thickness of powder coating shall not be less than 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified, complete all as specified and directed.
Powder coated aluminium (thickness of powder coating shall not be less than 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.), complete all as specified
Sheet glass, 4.0mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sq. m in each pane, complete with neoprene lining, complete all as specified and directed.
Sheet glass, frosted, 5.0mm thick, ordinary quality and glazing with oil putty in square, exceeding 0.5 sq. m in each pane, complete with neoprene lining, complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins / spring clips and providing and fixing new ones, complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, including ashlar facings, dressed stonework and precast concrete articles, PCC solid block masonry etc., with and including removal of debris outside MD land, approximately to a distance upto 5Km, complete all as specified and directed.
Pre-cast cement concrete block masonry with grade 'C' solid blocks, exceeding 10cm in width, having minium compressive strength of 50kg / sq.cm as per IS 2185 (Part-I) 2005 and setting in cement mortar (1:6), complete all as specified and directed.
Plate rack, made of stainless steel of grade 304, 0.63mm thick, of size 800mm x 600mm, fixed in repairs, complete all as specified and directed.
Vitreous China wash hand basin, flat back, size 560mm x 430mm white, excluding taps, waste pipe, chain and plug and porcelain stopper but including brackets, including cutting for and pinning in ends of brackets or erecting stand fixed in repairs, complete all as specified and directed.
Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc., with and including provision of seat cover black closed pattern with flat bottom with mild steel CP hinging device, with and including removal of debris outside MD land, approximately to a distance upto 5Km, complete all as specified and directed.
PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets, 32mm dia flush pipe and connections to pipes and fixing of chain and pull, or lever, if any, fixed in repairs, complete all as specified and directed.
Stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, 15mm bore, fixed in repairs, complete all as specified and directed.
Stop valves, cast copper alloy, fancy type, chromium plated, with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, 15mm bore, fixed in repairs, complete all as specified and directed.
Bib taps, cast copper alloy, fancy type, chromium plated, with long shank, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs, 15mm bore, complete all as specified and directed.
PVC mirror cabinet of size 350mm x 450mm, fixed in repairs, complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Rolled mild steel framed work, using sections conforming to Fe 410-W (Gde E-250) quality-A, as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, complete all as specified and directed.
Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc., complete all as specified and directed.
Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, 15mm bore, complete all as specified and directed.
UPVC (SWR) 'P’ trap, 110mm bore, complete all as specified and directed.
UPVC (SWR) 'S’ trap, 110mm bore, complete all as specified and directed.
UPVC (SWR) floor trap, plain with grating including jointing with solvent cement, 75mm dia, complete all as specified and directed.
UPVC (SWR) multi-floor trap, plain with grating including jointing with solvent cement, 75mm dia, complete all as specified and directed.
Chromium plated brass soap dish, fancy type, with wall hook, complete all as specified and directed.
UPVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed.
UPVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floors, 75mm bore, complete all as specified and directed.
UPVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floors, 110mm bore, complete all as specified and directed.
UPVC (SWR) bends any radius, 75mm bore, complete all as specified and directed.
UPVC (SWR) bends any radius, 110mm bore, complete all as specified and directed.
UPVC (SWR) vent cowl, 75mm bore, complete all as specified and directed.
UPVC (SWR) vent cowl, 110mm bore, complete all as specified and directed.
UPVC (SWR) branch piece, single (single Y) equal or unequal, 75mm bore, complete all as specified and directed.
UPVC (SWR) branch piece, single (single Y) equal or unequal, 110mm bore, complete all as specified and directed.
UPVC (SWR) junction single, (single T) equal or unequal, 75mm bore, complete all as specified and directed.
UPVC (SWR) junction single, (single T) equal or unequal, 110mm bore, complete all as specified and directed.
UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with and including provision of suitable size of PVC clamps, 160mm bore, complete all as specified and directed.
Taking up or down steel tubing and connections, 15mm bore, including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down steel tubing and connections, 20mm bore, including cleaning for refixing or removal to store, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 15mm bore of pipe, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, ffixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 20mm bore of pipe, complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (Walls. ceiling, floors, etc.) 20mm bore, complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (Walls. ceiling, floors, etc.) 15mm bore, complete all as specified and directed.
Waste coupling, of PTMT (half or full threaded), 32mm bore dia of discharge pipe, (Minimum weight for 32mm bore shall be 45grams), complete all as specified and directed.
Waste coupling, of PTMT (half or full threaded), 40mm bore dia of discharge pipe, (Minimum weight for 40mm bore shall be 60grams), complete all as specified and directed.
PVC connections 15mm size with PTMT nuts of length 450 mm, complete all as specified and directed.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed.
Toilet paper holder, fixed to walls with chromium plated brass screws, fixed in repairs, complete all as specified and directed.
Brass chromium plated shower rose with arms, 125mm dia, fixed in repairs, complete all as specified and directed.
Health faucet, chromium plated, fancy type, brass body with 1.0metre length stainless steel braided rubber hose pipe and wall hook, fixed in position to wall, complete all as specified and directed.
Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden / plastic cleats (Minimum weight 190gms), complete all as specified and directed.
Harrison rails, anodised aluminium alloy, chromium plated, with fixing brackets, stops, rollers etc., complete all as specified and directed.
Rendering 15mm thick in CM (1:4) in two layers (10mm thick and 5mm thick mixed with water proofing compound) on fair faces of brick work or concrete surfaces and finishing the surface even and smooth with out using exta cement, complete all as specified and directed. NOTE:- Water proofing compound shall be measured and paid separately under respective item of this Schedule.
Rendering 10mm thick in CM (1:6) on surfaces on fair faces of brickwork or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
Complete removal of existing treatment from surfaces of walls (internal and external) , complete all as specified and directed.
Applying two coats of acrylic emulsion distemper on wall surfaces over a coat of primer over and including 2.0mm thick internal grade wall care putty, finished even and smooth, complete all as specified and directed.
Preparation of old plastered surfaces of ceilings and applying one coat of white wash, complete all as specified and directed.
Preparation of old painted steel and iron surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Preparation of new or previously untreated steel and iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
Preparation of new or previously untreated surfaces wood and wood based materials, of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Preparation of old painted surfaces wood and wood based materials, of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Demolition of cement concrete (reinforced) in any position not otherwise specifically provided for including cutting of reinforcement as required to facilitate demolition, complete all as specified and directed.
Plain cement concrete (1:3:6), type C1 (using 20mm graded stone aggregate), 75mm thick, as in plinth protection, finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for (as in sunken floors, floor top etc.), complete all as specified and directed.
Plain cement concrete (1:5:10), type E2 (using 40mm graded stone aggregate), as in sunken floors, complete all as specified and directed.
Providing 1.0mm thick Brushbond RFX (which is a two component acrylic polymer modified cementitious coating which shall consists of Brushbond RFX powder and Nitobond BBX acrylic emulsion), grey in colour, of M/s FOSROC, applied using stiff brush, roller or trowel to obtain the desired thickness all as per manufacturers instructions, complete all as specified and directed.
Disconnecting existing water connections and taking down carefully from the roof of buildings of storage water tanks of capacity exceeding 250 litre but not exceeding 500 litre, complete all as specified and directed.
Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top), 500 litre capacity (ISI embossed), hoisted and fixed in position all as specified in SSR Part I, complete all as specified and directed.
PTMT high pressure ball valve (minimum weight shall be 210 grams), 20mm dia with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe, complete all as specified and directed.
Nipple, suitable 20mm bore of pipe, for PTMT ball valve of HDPE water tank (Minimum weight of 20mm-45grams), complete all as specified and directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, 20mm bore of pipe, fixed in repairs, complete all as specified and directed.
Sinks with drainage board made of stainless steel 1.00mm thick kitchen with plugs, washers and wastes; including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, fixed in repairs, complete all as specified and directed.
Post construction anti-termite treatment to soil under existing floors using chemical emulsion (Chlorophyriphos 20 EC conforming to IS 8944 or Imidacloprid 30.50 SC conforming to IS 16131 (Refer Table 1 on Sl. Page No. 2 of IS 6313 (Part 2):2013)) @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors, complete all as specified and directed.
Treating at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) (Chlorophyriphos 20 EC conforming to IS 8944 or Imidacloprid 30.50 SC conforming to IS 16131 (Refer Table 1 on Sl. Page No. 2 of IS 6313 (Part 2) : 2013)) @ 0.5 litre / hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same, complete all as specified and directed.
Treating soil along the external wall below concrete or masonry apron using chemical emulsion (Chlorophyriphos 20 EC conforming to IS 8944 or Imidacloprid 30.50 SC conforming to IS 16131 (Refer Table 1 on Sl. Page No. 2 of IS 6313 (Part 2) : 2013)) @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed.
Brushing neat cement slurry with 3.0kg of cement per sq. m, complete all as specified and directed.
Plain cement concrete (1:2:4), type B0 (using 12.50mm graded stone aggregate), 30mm thick as in levelling course over slabs, complete all as specified and directed.
Rendering 10 mm thick in CM (1:4) mixed with water proofing liquid as per manufacurer instructions over cleaned roof surface, finished fair and even, complete all as specified and directed. Note:- Water proofing liquid shall be measured and paid separately under respective item of this Schedule.
APP based polymeric membrane minimum weighing 3.5 kg / sq.m and minimum 3.5mm thick reinforced with polyester non woven fabric (weight not less than 160 gms / sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 litre/sq.m by forced application, complete all as specified and directed. The complete roof treatement shall be consisting of as under :- (i) Applying one coat of bituminous primer conforming to IS-3384 @ 0.3 litre / sq.m (ii) Laying of APP based membrane of specified thickness and weight. (iii) Applying one coat of bitumen of grade 85/25@ 1.2 Kg / sq.m (iv) Applying two coat of aluminium paint @ 100 ml / sq.m
Supply only integral water proofing compound
Disconnecting existing tanks, exceeding 500 litres and not exceeding 1000 litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and directed. Note :- Cleaning repairing, etc., included in unit rate qouted.
Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, light shade, premium quality, double charged of approved quality, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including provision of 15mm thick screed bed in CM (1:4), complete all as specified and directed.
Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, light shade, premium quality, double charged of approved quality, area of each tiles not exceeding 0.36 sqm, in skirtings, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including provision of backing coat of 10mm thick in CM (1:3), complete all as specified and directed.
Applying two coats of weather-proof antifungal exterior emulsion paint, first quality, over a coat of primer all as per manufactureres instructions, complete all as specified and directed.
Plain cement concrete (1:3:6), type C2 (using 40mm graded stone aggregate), 75mm thick, as in hard standing, floors, finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, with grey cement and no pigment, complete all as specified and directed. MAKE:- As approved by GE
Chequered colourd cement concrete tiles 30cm x 30cm x 25mm thick, as in floors with grey cement and pigment laid over and including15mm thick screed bed in CM (1:4), set, jointed and pointed in neat cement slurry, complete all as specified and directed.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes with modular frame plate and white cover of required modules for housing switches, sockets, regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. (i) One light point controlled by one, one way modular switch. NOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
All as per Sl. Item No. 128 here-in-before, but for one fan point controlled by one, one way, complete all as specified and directed.
All as per Sl. Item No. 128 here-in-before, but for one light point controlled by two, two way switches, complete all as specified and directed.
All as per Sl. Item No. 128 here-in-before, but for one bell point controlled by one, bell push, complete all as specified and directed.
All as per Sl. Item No. 128 here-in-before, but for one 3 pin, 6 Amps switch socket outlet point on independent board, complete all as specified and directed.
Point wiring complete with 4.0 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes with modular metal frame plate and white cover for housing switches, sockets, regulators etc., including 2.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one 3 pin,16 Amps switch socket combination, complete all as specified and directed. NOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
Modular switch one way, 6 Amp, one module, (ISI marked), complete all as specified and directed.
Modular switch two way, 6 Amp, one module, (ISI marked), complete all as specified and directed.
Modular switch one way, 16 Amp, one module, (ISI marked), complete all as specified and directed.
Modular socket, 6A - 2/3 pin combined 2 module, (ISI marked), complete all as specified and directed.
Modular Socket 6A/16A - 2/3 pin combined 2 module, (ISI marked), complete all as specified and directed.
Ceiling rose, 3 terminal / PVC / polycarbonate, isolated body, complete all as specified and directed.
Modular Bell push 6A 1 module (ISIS marked), complete all as specified and directed.
Buzzer, Ding Dong AC. 230 volts, single pole, complete all as specified and directed.
Stepped type electronic fan regulator modular type, 120W, two module, fixed as required, complete all as specified and directed.
Surface / ceiling mounted 20 Watt LED flat panel batten fitting luminaire with extruded polycorbonate environmental friendly with better aesthetic finish, for soft light and glare free symmetrical illumination, duly wired up to terminal block, complete all as specified and directed. Make:- Cat No. LUMILINEBS 20W 865 SPCWH of Havells or techno commercially equivalent Model in BAJAJ/PHILIPS/CG
High efficient LED batten surface / wall mounted, 9 Watt mirror light, specially designed extruded thermal polycorbonate housing, duly wired up to terminal block, complete all as specified and directed. Make:- Cat No. LUMILINEBS 9W 865 SPCWH of Havells or techno commercially equivalent Model in BAJAJ/PHILIPS/CG
Distribution board TPN 4-way with 200 Amps rated bus bar, double door, suitable for 415 Volts, fixed in repairs, including one MCB 100 Amps, TPN 415 Volts, 10 KA breaking capacity alongwith all necessary electrical connections with copper lugs, complete all as specified and directed.
Distribution board SPN 12-way with 200 Amps rated bus bar, double door, suitable for 240 Volts, fixed in repairs, complete all as specified and directed.
MCB SP 6 to 40 Amps, 240 Volt, 50Hz, 'C' curve type, 10KA breaking capacity, complete all as specified and directed.
MCB SPN 6 to 40 Amps, 240 Volt, 50Hz, 'C' curve type, 10KA breaking capacity, complete all as specified and directed.
Sub main wiring complete with 2 runs of 6.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 25mm dia and its accessories and connecting terminal ends to DB's including providing 1 run of 6.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down existing unserviceable sub main wiring, complete all as specified and directed. NOTE:- (i) Two runs of 6.0 sq.mm copper conductor, one run of 6.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with 2 runs of 10 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 25mm dia and its accessories and connecting terminal ends to DB's including providing 1 run of 10 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down existing unserviceable sub main wiring, complete all as specified and directed. NOTE:- (i) Two runs of 10 sq.mm copper conductor, one run of 10 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Taking down ceiling fans, removing blades and refixing after cleaning, servicing, greasing, painting with one coat of synthetic enamel paint by sprayer with and including filling of cavities with filler and replacement of connecting cable with copper conductor flexible cable of suitable size, complete all as specified and directed.
Taking down exhaust fans, removing blades and refixing after cleaning, servicing, greasing, painting with one coat of synthetic enamel paint by sprayer with and including filling of cavities with filler and replacement of connecting cable with copper conductor flexible cable of suitable size, complete all as specified and directed.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI wire of 4mm dia by means of bolts, nuts, washers etc., GI wire shall be protected by 20mm dia GI pipe 'light grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:12:4) type B-1 earth chamber with 40mm x 40mm x 6mm MS angle iron frame, 40mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc., with plastering 15mm thick in CM 1:6 internally and upto 150mm below GL externally, PGI funnel with wire mesh, complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre.
M/s SRINIVASA CONSTRUCTION COMPANY
shashi shekar construction
SREE BUILDERS
C R R CONSTRUCTIONS
Lucky Enterprises
Gnani Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .