Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹63.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST REASONABLE BIDDER | |
| 2 | L2₹74.7 L+₹8.4 L (12.6%)Rejected-Finance MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹77.7 L+₹11.3 L (17.1%)Rejected-Finance DIWANBADA MANEGAON POST OFFICE KHAMARIA JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹81.7 L+₹15.3 L (23.1%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | RAVINDRA ELECTRICAL L2 | C L BHATIA L3 | New Era Engineers L4 | KISHOR KALAMKAR L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fixing in replacement of day to day complaint switch piano flush button single pole one way, 6 Amps, 240 V complete. | 950 | Each | 45 ₹42,750 | 22 ₹20,900 Lowest | 25 ₹23,750 | 22 ₹20,900 Lowest |
| 2.00 | Supply and fixing in replacement of day to day complaint bell push piano flush type 6 amps , 240 V complete. | 200 | Each | 45 ₹9,000 | 34 ₹6,800 | 45 ₹9,000 | 25 ₹5,000 Lowest |
| 3.00 | Supply and fixing in replacement of day to day complaint buzzer door bell, AC 230 volts Single Phase complete. | 200 | Each | 240 ₹48,000 | 180 ₹36,000 | 400 ₹80,000 | 50 ₹10,000 Lowest |
| 4.00 | Supply and fixing in replacement of day to day complaint socket outlet 2-in-1 3 pin, 6 Amps flush type complete all as specified and as directed. | 500 | Each | 43 ₹21,500 | 40 ₹20,000 | 48 ₹24,000 | 35 ₹17,500 Lowest |
| 5.00 | Supply and fixing in replacement of day to day complaint Switch socket combination 2-in-1 3 pin 6 Amps flush type complete all as specified and as directed. | 540 | Each | 58 ₹31,320 Lowest | 70 ₹37,800 | 175 ₹94,500 | 85 ₹45,900 |
| 6.00 | Supply and fixing in replacement of day to day complaint Switch piano flush button single pole one way, 16 Amps, 230/240 V complete. | 450 | Each | 60 ₹27,000 Lowest | 65 ₹29,250 | 110 ₹49,500 | 80 ₹36,000 |
| 7.00 | Supply and fixing in replacement of day to day complaint Socket outlet 2-in-1 3 pin, 6 & 16 Amps flush type complete all as specified and as directed. | 400 | Each | 140 ₹56,000 | 80 ₹32,000 Lowest | 125 ₹50,000 | 80 ₹32,000 Lowest |
| 8.00 | Supply and fixing in replacement of day to day complaint Switch socket combination 3 pin , 6A and 16 Amps flush type universal controlled by one switch complete. | 450 | Each | 150 ₹67,500 Lowest | 150 ₹67,500 Lowest | 220 ₹99,000 | 160 ₹72,000 |
| 9.00 | Supply and fixing in replacement of day to day complaint Fan regulator socket type stepped type (electronic ) for 1200/1400mm sweep AC ceiling fan complete. | 350 | Each | 230 ₹80,500 Lowest | 345 ₹1,20,750 | 325 ₹1,13,750 | 350 ₹1,22,500 |
| 10.00 | Supply and fixing in replacement of day to day complaint modular type switch, one way 6 Amps , 1 module complete all as specified and directed. | 250 | Each | 35 ₹8,750 | 45 ₹11,250 | 40 ₹10,000 | 25 ₹6,250 Lowest |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
1 Dec 2025, 6:00 pmClosed
CWE JABALPUR
HQ COMMANDER WORKS ENGINEER, SUPPLY MARG, P B NO. 54, JABALPUR
COMPREHENSIVE DAY TO DAY MAINTENANCE/REPAIR/REWIRING AS APPLICABLE FOR INTERNAL ELECTRIFICATION AND WINTER APPLICANCES SUCH AS INTERNAL LIGHT FITTINGS AND FIXTURES, POINT WIRING SUBMAIN WIRING WITH REPLACEMENT OF MCBS, DBS ETC UNDER GE (E) JABALPUR
2025_MES_738108_1
82735/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
JABALPUR
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (EAST) JABALPUR
₹2.0 L
Yes
7 Feb 2026
1 Nov 2025
8 Dec 2025
1 Nov 2025
1 Dec 2025
24 Nov 2025
1 Nov 2025 - 22 Nov 2025
Amount
Supply and fixing in replacement of day to day complaint switch piano flush button single pole one way, 6 Amps, 240 V complete.
Supply and fixing in replacement of day to day complaint bell push piano flush type 6 amps , 240 V complete.
Supply and fixing in replacement of day to day complaint buzzer door bell, AC 230 volts Single Phase complete.
Supply and fixing in replacement of day to day complaint socket outlet 2-in-1 3 pin, 6 Amps flush type complete all as specified and as directed.
Supply and fixing in replacement of day to day complaint Switch socket combination 2-in-1 3 pin 6 Amps flush type complete all as specified and as directed.
Supply and fixing in replacement of day to day complaint Switch piano flush button single pole one way, 16 Amps, 230/240 V complete.
Supply and fixing in replacement of day to day complaint Socket outlet 2-in-1 3 pin, 6 & 16 Amps flush type complete all as specified and as directed.
Supply and fixing in replacement of day to day complaint Switch socket combination 3 pin , 6A and 16 Amps flush type universal controlled by one switch complete.
Supply and fixing in replacement of day to day complaint Fan regulator socket type stepped type (electronic ) for 1200/1400mm sweep AC ceiling fan complete.
Supply and fixing in replacement of day to day complaint modular type switch, one way 6 Amps , 1 module complete all as specified and directed.
Supply and fixing in replacement of day to day complaint modular type socket 3 pin, 6 Amps combined 2 module complete all as specified and directed.
Supply and fixing in replacement of day to day complaint modular type socket 3 pin, 6 /16 Amps combined 2 module complete all as specified and directed.
Supply and fixing in replacement of day to day complaint modular type switch, one way 16 Amps, 1 module complete all as specified and directed.
Supply and fixing in replacement of day to day complaint PVC plug top 3 pin with easy grip white matte finish tested as per IS 1293, 6 Amp capacity ISI marked all as specifed and directed.
Supply and fixing in replacement of day to day complaint PVC plug top 3 pin with easy grip white matte finish tested as per IS 1293, 16 Amp capacity ISI marked all as specifed and directed.
Supply and fixing in replacement of day to day complaint metalic plug top 3 pin with easy grip white matte finish tested as per IS 1293, 15/16 Amp capacity ISI marked all as specifed and directed.
Supply and fixing in replacement of day to day complaint fan capacitor 2.15 mfd to 2.5 mfd all as specifed and directed.
Material and labour in replacement of day to day complaint modular sheet cover plate with frame of size 08 module including necessary electrical connection as per existing point wiring all as specifed and directed.
Material and labour in replacement of day to day complaint modular sheet cover plate with frame of size 6 module including necessary electrical connection as per existing point wiring all as specifed and directed.
Material and labour in replacement of day to day complaint modular sheet cover plate with frame of size 3 module including necessary electrical connection as per existing point wiring all as specifed and directed.
Material and labour in replacement of day to day complaint GI/pressed steel terminal switch board of size 8 module including necessary electrical connection as per existing point wiring all as specifed and directed.
Material and labour in replacement of day to day complaint GI/pressed steel terminal switch board of size 4 module including necessary electrical connection as per existing point wiring all as specifed and directed.
Material and labour in replacement of day to day complaint GI/pressed steel terminal switch board of size 3 module including necessary electrical connection as per existing point wiring all as specifed and directed.
Taking down carefully aluminium conductor point wiring (light, fan, light socket, power socket) complete fitting such as swithes, sockets, lamp holder, utility light fitting, fan regulator etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed.
M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FRLSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FRLSH (ISI marked) as earth continuity conductor connected to common earth dolly, including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles. Note:- Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for One light point controlled by one switch 5/6 Amps.
One light / fan point controlled by one, one way switch 6 Amp complete.
Ditto but one 3 pin modular socket outlet 6 amp independent board.
Ditto but one 3 pin modular socket outlet 6 amp on same board.
Ditto but one 3 pin 6 Amps modular socket outlet independent but below the switch board of light points in the same vertical plane.
One bell/ buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 sqmm size complete all as specified and directed.
Ditto all as per srl item No 25 above but for one 3 pin modular socket outlet 15/16 Amps independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire.
M & L point wiring complete with 1.5 Sqmm single core multi stranded copper conductor FRLSH insulated and unsheathed medium duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLSH insulated drawn in existing concealed / surface PVC/Steel conduit and including terminated into suitable module Modular Metal flush Boxes including white cover plate with frame as per relevant IS for mounting switches, sockets, fan regulators etc complete all as specified and as directed for One light point controlled by one 6 Amps one way switch.
All as per above item No-27 but One ceiling Fan, Exhaust Fan point controlled by one 6 Amps switch.
All as per above item No-27 but One bell/buzzer point controlled by one bell push button on independent.
All as per above item No-27 but One light point controlled by 2 Nos ,6 amps Two way switch.
All as per above item No-27 but One 3 pin socket out let 6 Amp point on independent board
All as per above item No-27 but One 3 Pin socket out let 6 Amp point on the same board with other switch.
All as per above item No-27 but with 2.5 Sqmm cable for 16 Amps switch sockets out let point on independent board including 2.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor.
S&F switch modular one way 06 Amp,1 module all as specified and directed.
S&F switch modular one way 16 Amp,1 module all as specified and directed.
S&F Modular socket 6A-3 Pin 2 module 230V AC all as specified and directed.
S&F Modular socket 6A/16A-3 Pin 2 module 230V AC all as specified and directed.
S&F modular bell push type one way 6 Amp 1 module all as specified and directed.
S&F modular type fan regulator 2 Module all as specified and directed.
S&F 1 module dummy plate all as specifed and directed.
M&L point wiring with 1.5 Sqmm single core multi stranded copper conductor FRLSH insulated and sheathed medium duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm multistranded copper conductor FRLSH insulated drawn in exisitng concealed/surface conduit terminated into GI/pressed steel terminal boxes including 3 mm thick hylam sheet cover to mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :-
One light/fan point controlled by one, one way switch 6 Amp complete.
Ditto but one 3 pin socket outlet 6 amp independent board.
Ditto but one 3 pin socket outlet 6 amp on same board.
Ditto but one 3 pin 6 Amps socket outlet independent but below the switch board of light points in the same vertical plane.
One bell/ buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 sqmm size complete all as specified and directed.
Ditto all as per srl item No 41 above but for one 3 pin socket outlet 15/16 Amps independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire.
S&F switch piano flush button polycarbonate single pole one way 6 Amps, 240 V complete all as specified and directed.
S & F switch piano flush button polycarbonate single pole one way 16 Amps, 240 V complete all as specified and directed.
S & F bell push piano flush type polycarbonate 6 amps, 240 V complete all as specified and directed.
Supply and fixing bell Ding Dong AC 230 volts Single Phase complete all as specified and directed.
Supply and fixing of socket outlet 3 pin, 6 Amps flush type polycarbonate complete all as specified and directed.
Supply and fixing of socket outlet 3 pin, 15/16 Amps flush type polycarbonate complete all as specified and directed.
Supply and fixing of Fan regulator socket type stepped type (electronic) polycarbonate for AC ceiling fan complete all as specified and directed.
Supply and fixing of ceiling rose surface, backelite, three terminal, 240 volts complete all as specified and directed.
Supply and fixing of lamp holder, Polycarbonate type with back plate suitable for batten fittings all as specified and as directed.
Supply and fixing in replacement of LED lamp suitable for B22 holder of capacity 7 Watt complete all as specified and directed.
Supply and fixing of LED lights fitting 1 x 18 W, 220 V, AC decorative box type with driver, holder, including LED Tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing in replacement of LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal complete all as specified and directed management in multiple optics complete with IP 65/66 protection.
Supply and fixing in replacement of LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing in replacement of LED luminaire 600 mm X 600 mm 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing in replacement of round shape 12 watt 220 Volts AC recessed type with high efficiency PMMA diffuser sift glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing in replacement of Fancy type LED fitting 7 watts , 230 volts Brass made bracket with 115 mm dia round base , Brass Arm Length 57 mm provided with 78 mm length x 76 mm breadth gallary, inside 2 pin brass holder frosted glass shade 170 mm lenghth (conical shape) Finish black nickel & gold plated complete all as specified and directed.
Supply and fixing in replacement of Vertical Distribution Board (VTP&N) 4 way double door suitable for MCCB 4 pole of cap upto 250 Amp as incomer and out going MCBs SP and should be IP 54 protected with Copper Bus Bars, Neutral Links, Earthing bar all as specified and directed.
Supply and fixing in replacement of MCCB four pole 100 Amp, 16 KA, 415 volts with adjustable thermal settings all as spcified and ditected. Note: TPN DB and MCCB should be of same make.
Supply & fix in replacement of Distribution Board MCB TPN 4 way double door, 415 V suitable for MCB four pole as incomer and out going MCBs and should be IP 43 protected with Copper BusBars, Neutral Links, Earthing bar all as specified and directed. including taking down old UNSV DB/MCB any type. Note:- (i). MCBs shall be measured and paid separately. (iii) TPN DB and MCB should be of same make.
Supply & fix in replacement of sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification.
All as per item No 63 but 8 Way double door complete all as specified and directed.
All as per item No 63 but 4 Way double door complete all as specified and directed.
Supply & fix in replacement of MCB Four pole 415 volt 40-100 Amps 415V 10KA 'C' curve miniature circuit breaker for inductive load connected through cable lugs of suitable size complete all as directed and specified.
Supply & fix in replacement of MCB Single pole and neutral 240 volt 32 Amp for inductive load connected through cable lugs of suitable size complete all as directed and specified.
Supply & fix in replacement of MCB single pole (SP) 240 volt 06-32 amp for inductive load connected through cable lugs of suitable size complete all as directed and specified.
Supply and fixing in replacement of rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm and 50 mm deep complete all as specified and directed.
Supply and fixing in replacement of rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 175 mm x 100mm and 50 mm deep complete all as specified and directed.
Supply and fixing in replacement of MCB Single pole and neutral 240 volt 40-63 Amp for inductive load connected through cable lugs of suitable size complete all as directed and specified.
Supply and fixing in replacement of sub main wiring with single core cable 2 x 10 sq mm FRLSH insulated unsheathed stranded copper conductor cable 1100 Volts grade in rigid PVC conduit (Concealed) medium grade alongwith 1x10 Sq mm FRLSH insulated unheathed stranded copper conductor cable as earth wire connected with main earth dolly including chiseling, cutting & making good to match with the existing surface incl taking down complete all as specified and directed.
All as per item No 72 above but 2x6 sq mm and 1x6 sq mm as earth wire. NOTE : Two runs of 4 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables with MCBs or bus bar shall be done through appropriate size brass/ copper thimbles.
All as per item No 72 above but 2x4 sq mm and 1x4 sq mm as earth wire.
All as per item No 72 above but 2x2.5 sq mm and 1x2.5 sq mm as earth wire
S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire one twin core cable flat or circular of size 10 Sqmm incl taking down old service connection and removing from the side complete all as specified and as directed.
All as per ser item No 75 above but 16 sqmm twin core service wire.
Taking down carefully ceiling fan/exhaust fan any type, size or make with cable and all accessoreis remove from site to store for repair/overhaulling complete all as directed.
Overhauling of Ceiling fan 1200/1400 mm sweep by opening and cleaning rotor, bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and coonecting on its existing position and testing on completion all as specified and as directed. (Note : Items required to be replaced & rewinding of fan motor if required will be measured and paid separately in relevent items )
Dismantling of Ceiling fan 1200/1400 mm sweep along with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding, ball bearing, gun metal bush etc complete to carry out the folling repairs :- (a) Removing of burnt out fan winding and rewinding it with suitable size of Copper enamelled wire (weight of copper coil shall be same as per dismantled fan), heating and varnishing as per manufactures design & direction. (b) Re-assembling the ceiling fan by fixing only serviceable spare parts complete to give designed air delivery including greasing, oiling etc, reconnecting / hanging in original position, reconnecting the electric cables and testing complete, all as directed.
M & L for painting of ceiling fans (1200 mm/ 1400 mm) complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts including writing of MES Nos in black paint all as specified and as directed.
Overhauling of exhaust fan 200 mm to 450 mm sweep (steel body/pvc body) after opening and cleaning rotor, bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and coonecting on its existing position and testing on completion all as specified and as directed. (Note : Items required to be replaced & rewinding of fan motor if required will be measured and paid separately in relevent items )
Dismantling of exhaust fan (steel body) 250 to 450 mm sweep, unscrewing the body parts, taking out starter, rotor winding, ball bearing, gun metal bush etc.,removing of burnt out fan winding and rewinrng it with suitable size of Copper enamelled wire (weight of copper coil shall be same as per dismantled fan), heating and varnishing as per manufactures design & direction, re-assembling the fan by fixing only serviceable spare parts complete to give designed air delivery including greasing, oiling etc, refixing the same in original position, reconnecting the electric cables and testing complete, all as directed.
M & L for painting of Exhaust fans (steel) of size 300 mm to 450 mm sweep complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts all as specified and as directed.
Supply and fixing in replacement of louvers shutters any type complete with nuts, bolts and washers suitable for exhaust fans of size above 250 mm and up to 450 mm sweep complete all as specified and directed.
Supply & fixing in replacement of ball bearing suitable for exhaust fans 300/450mm dia sweep.
Supply & fixing in replacement of Capacitor 2.5 mfd for ceiling fans.
Supply & fixing in replacement of Capacitor 4 mfd for exhaust fans complete all as specified and directed. .
Supply & fixing in replacement of gun metal bush suitable for ceiling fans of 1200/1400 mm sweep complete all as specified and directed.
Supply & fixing in replacement of gun metal bush suitable for exhaust fans of 300/450 mm sweep complete all as specified and directed. .
Supply & fixing in replacement of three core flexible wire 1 Sqmm for connecting up ceiling fans , exhaust fans/wall mounting fan etc complete all as specified and directed. .
Supply & fixing in replacement of the wheel type rubber bush with nut,bolt,washers,locking clip etc. suitable for hanging the ceiling fans complete all as specified and directed.
Supply & fixing in replacement of the mounting clamps with nut, bolt, washers, locking clip etc complete suitable for fixing at the top of down rod suitable for fixing the ceiling fan complete all as specified and directed. .
Supply & fix in replacement of ceiling fan down rod of MS pipe 15mm bore 1.2/1.5 Mtr length including cutting/threading making tide for fixing providing check nuts wachers and clamp with rubber bush etc complete.
Supply & fix in replacement of Casing Caping of size 20 mm, ISI marked complete all as specified.
M &L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in coping of pole ect including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed.
Supply & fixing in replacement of electronic LED driver 36 Watt for panel type fitting of suitable size as per existing model complete all as specified.
M & L in replacing of LED driver 9/10/11W/15W/20W fitting of suitable size as per existing model complete.
M & L for galvanised steel earthing complete with 60 cm x 60 cm x 6 mm thick galvanised steel earth electrode and 04 mm dia galvanised earth lead wire burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to earth lead 4.0 mm dia GI wire protected by 15 mm bore light grade galvanised iron pipe and other and connected to test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron wire mesh, charcoal and common salt in alternater of 15 cm complete thickness all around the GI plate electrode complete with earth pit PCC 1:3:6 type CI and RCC cover and necesary excavation and earth work in hard/dense soil and disposal of spoil to a distance not exc 50 mtr and necessary testing complete all as shown in electorical plate No 03 connected to earthing test point including following elements/works all as specified.
Taking down the existing conduit and copper wire before Supplied & fixed in replacement of Rigid non-metallic PVC conduit of size 20mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, after fixing of conduit inserting the existing copper wire and connection as per existing complete all as specified and directed etc.
Taking down carefully storage type water heaters (Geyser) of any type and make of capacity upto 50 ltrs for servicing after disconnecting their electrical and water connections. De-scaling the inner container, heating element, base assembly using diluted hydrochloric acid and cleaning thoroughly. Filling the inner container with water and detecting leakage including brazing as required to stop the leakage, if any, reassembling the geysers after replacing the u/s spare parts, filling water and testing the geysers by applying pressure by means of hand/foot operated pump, to ensure leak proof. Refixing geyser in the same original position/location and making the electrical/water supply connections incl testing on completion complete all as specified and directed. (Note for sr item no 122 & 123 : (i) Items required to be replaced will be measured and paid separately under relevent items of the Schedule (ii) The rate for fixing of new spare parts are deemed to be included in quoted unit rate of above items)
S & F in repairs geyser elements 1.5 KW as per existing pattern fitted in the geyser all as specified and directed.
Description all as per item No 102 above but 2.0 KW complete all as specified.
S & F In repairs Thermostat suitable for any make & type of Geyser 25/35/50 ltr capacity complete all as specified and directed.
S & F In repairs indicating lamp for geysers red/green all as per site requirement and specified.
S & F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm as inlet for cold water including taking down the old unserviceable PVC connection pipe complete all as specified and as directed.
Supply & fixing in repairs PVC connection 15 mm size, spirally reinforced with stainless steel wire inside the pipe for outlet hot water pipe connection, with brass nuts at both ends of length 450 mm including taking down the old unserviceable PVC pipe all as specified and as directed by EIC.
Supply & fixing in repairs of inner tank of 25 ltr capacity of tinned/ copper of approved make all as specified and directed as per site requirement.
Supply & fixing in replacement of glass wool/mineral wool same as (Thermal insulation) for geyser of any type, capacity all as directed.
Supply & fixing in repairs pressure release valve suitable for 25/50 ltrs capacity geyser of approved make and type all as site requirement.
Supply & fixing in repairs brass ferrul of 15 mm size complete all as specified and directed.
Supply and fix in replacement of 3 core multi strand copper conductor PVC insulated cable 2.5 Sqmm1100 volts grade complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs of geyser assembly 6/9 holes for 25/50 Ltr cap geysers including synthetic rubber gasket of suitable size matching with existing holes and tightening all as directed by Engr-in-Charge.
Supply and fix in replacement of 3 core multi strand copper conductor PVC insulated cable 2.5 Sqmm1100 volts grade complete all as specified and directed by Engr-in-Charge.
S & F In repairs MS Anti Suicide Fan Rod (smart Fan rod) of standard size (12/18 inch) and grade ISI marked, having bearable weight 20-22 Kg, heavy duty, 15mm dia complete required for hanging of ceiling fan all as directed by Eng-in-charge.
S & F In repairs 'U' shape shackle clamp assembly incl. checknut, bolts, screws, washer, lock nut, rubber reel etc.and connecting complete all as directed.
S & F In repairs fan hook made out of steel bar as per sample.
S & F In repairs of Unserviceable fan blade suitable for ceiling fan of any type / size as per sample complete all as directed.
Taking down old corroded and u/s Flame proof light fittings of heavy duty single and dual/twin type any capacity from existing positions complete all as specified and directed. Note:- Quoted rate is deemed to be included the charges of tools and plants etc.as per site requirement and MS work complete all as specified and directed.
S&F In repairs LED light fitting 1 x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc including hose pipe complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Taking down of existing flame proof tube light fittings from wall & refixing the same flame proof fitting at the same/other location including replacement of necessary polycarbonate LED Tube rod 4 feet, 18/20 watt complete all as specified and directed.
Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 30W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and Fixing in repair Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified.
Supply and Fixing in repair Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified.
Supply and Fixing in repair Flame proof and weather proof fan regulator for flame proof ceiling fans of size 48" suitable for hazardous locations of zone 1 & 2 with relevant IS complete all as specified.
Supply and Fixing in repair flexible steel conduit suitable for Flame proof wiring, not less than 20 mm dia complete all as specified.
Material & labour for following flameproof submain wiring alongwith earth wire in and including the suitable size of stove enamelled rigid ERW steel conduit incl FRLSH PVC insulated copper conductor, two run single core cable for phase & neutral and single run as earth wire in surface,recessed as required and directed by Eng-in-charge. Note:- Quoted rate is deemed to be included the charges of tools and plants etc.as per site requirement and MS work complete all as specified and directed.
All as per item no.139 here-in-before but 2x4 Sqmm for phase & neutral and 1x4 Sqmm as earth wire.
All as per item no. 139 here-in-before but 2x6 Sqmm for phase & neutral and 1x6 Sqmm as earth wire.
All as per item no.139 here-in-before but 4x6 Sqmm for phase & neutral and 1x6 Sqmm as earth wire.
S&F in replacement of PVC insulated, unsheathed twin twisted copper conductor wire of nominal size 23/0.0076, 1100 volt grade, ISI marked, complete all as specified and directed.
S&F In repairs LED Mirror light fitting 2 ft tubelight 10 watt aluminum housing and integrated electronic driver THD max 10 % ,CRI min 80 % complete with fixing arrangements on wall all as specified and directed.
Supply and Fixing in repairs for LED luminaire cool day light/warm white as required of size 1'x4' square LED panel 35/36 watts, 220V recessed type with high efficieny PMMA diffuser soft glare free light complete with drovers, holders, LED lamp suitable for roof ceilling, including connecting up with driver three core flexible copperr conductor cases of suitable size complete all as specefied and directed.
M & L for loop type insulator vitrous porcelien white, borwn or green large size with dimensions 90 mm x 140m m, clearance of hole 25.5mm etc complete all as specified and directed.
M & L for Single pointed air termination aluminium rod, 12 mm dia, 300 mm longer etc complete all as specified and directed.
M & L for aluminium strip 25 mm x 3 mm complete with saddles and fixing screws as roof conductor etc complete all as specified and directed.
M & L for GI strip 32 mm x 6 mm buried in ground complete etc complete all as specified and directed.
M & L for Test point terminal block made of gun or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex. Head screw including removal old extg UNSV one complete all as specified and directed.
Supply and fix of Tubes light grade galvanized of size 40 mm dia with all fittings and fixed complete for suporting the air termination rod and protection of GI strip complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection of GI strip to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR par - I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal. Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
Supply & fix in replacement of sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 2 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC stranded sheathed 3 core, 6 sq mm nominal cross section in service connections
The contractor shall attend to the office of Engr-in-Charge daily in persion or through his authorised representative with necessary T&P and collect the day to day complaint with respect to the area of contract against Item No. 3 to 25, 55-96.
NOTE: (i) The contractor shall maintain a regular sufficient manpower to attend all the complaints provided by JE/Engr-in-Charge on day-to-day basis. The non adherence to this condition shall lead to recovery of Rs. 500/- per day for each complaint pending for more than 24 Hrs. (ii) Rate of Other items like screws, nuts, insulation tape, copper wire of diferent size upto 01 mtr length etc are covered under Item No. 3 to 25, 55-96
Schedule of credit amount of Rs 2,79,744.00 to be deducted during AOC
RAVINDRA ELECTRICAL (BID ID -3490818)
C L BHATIA (BID ID -3492226)
New Era Engineers (BID ID -3492519)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
TENDER1.pdf
Tender Documents • 2.15 MB
BOQ_826492.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .