| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.0 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L-1 | Accepted-AOC lowest bidder for the work. | |
| 2 | L-2₹9.5 L+₹32,196.50 (3.51%)Rejected-Finance | L-2 | Rejected-Finance other than the lowest bidder | |
| 3 | L-3₹9.6 L+₹39,358.20 (4.29%)Rejected-Finance | L-3 | Rejected-Finance other than the lowest bidder |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
13 Jan 2025, 6:00 pmClosed
Col Pawan Kumar CWE Bhopal
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
MAINT AND REPAIR OF HT DISTRIBUTION SYSTEM, TRANSFORMER, DEHYDRATION OF TRANSFORMER OIL AND CERTAIN OTHER ASSOCIATED WORKS AT DSCC AYODHYA NAGAR UNDER GE DRONACHAL
2024_MES_686963_1
83968/E8
Open Tender
Civil Works
Item Rate
180 days
DRONACHAL
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
GE Dronachal
₹26,000
Yes
1 Feb 2025
4 Dec 2024
15 Jan 2025
4 Dec 2024
13 Jan 2025
23 Dec 2024
4 Dec 2024 - 23 Dec 2024
Amount
Excavation in trenches/ foundation in hard/dense soil not exc. 1.5 metre wide and n'exc. 1.50m deep for poles, laying of cables, etc. and getting out complete all as specified and directed.
Returning filling including spreading leveling watering and well ramming in layers not exc 25 Cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed.
S/F in dry coarse sand in cable trenches before and after the cables are laid in sand cushioning to cables complete all as specified and directed.
S&F graded crushed stone coarse aggregate 40 mm and relaying the same after cleaning in yard and around transformer plinth and two pole structures/33 KV Main Receiving Station complete all as specified and directed.
M&L Cement Concrete (1:4:8) type D-2 (40mm Graded Stone Aggregate) as Lean Concrete, Bed Concrete in Foundation of Poles, etc., including Formwork (as required), complete all as specified and directed.
M&L Cement Concrete (1:3:6) type C-2 (40mm Graded Stone Aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as required), complete all as specified and directed.
M&L Cement Concrete (1:2:4) type B-1(20mm Graded Stone Aggregate) as in Coping of Poles, etc. including Formwork (as required), complete all as specified and directed.
Dismantling insulators any type, any size complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m complete all as specified and directed.
Dismantling/takng down UNSV GOD and DO fuse of any capacity complete all as specified and directed.
Dismantling of ACSR conductors complete all as specified and directed.
Dismantling/taking down lightening arrester of any description complete all as specified and directed.
Dismantling/taking down HT UG cable of any description complete all as specified and directed.
Dismantling/taking down old unserviceable GI pipe of any description complete all as specified and directed.
Dismantling/taking down HT cable joint of any description complete all as specified and directed.
Supply , Laying , jointing and testing of HT XLPE insulated PVC sheathed armoured heavy duty electric cables with aluminium conductor for working voltage upto and including 33000 volts of cross sectional area 240 Sqmm 1 core complete all as specified and directed.
Supply , Laying , jointing and testing of HT XLPE insulated PVC sheathed armoured heavy duty electric cables with aluminium conductor for working voltage upto and including 33000 volts of cross sectional area 185 Sqmm 3 core complete all as specified and directed.
S&F Galvanised Iron Pipe 100 mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed.
M & L for Supplying and laying un-reinforced precast concrete cable cover, class EHV, type 2 with peak, size 450mm x 180mm x 40mm complete all as specified and directed.
Supply & Replacement of cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified and directed.
S & F polymer pin insulator, Type B, Nominal System voltage 33 kV, highest system voltage 36 kV, visible discharge test voltage 33 kV, wet power frequency withstand voltage 35 kV, power frequency puncture withheld voltage 105 kV, minimum total creepage distance 900 mm, minimum failing load 10 kN, of suitable size with galvanised steel insulator pin, nut, washers complete all as specified and as directed.
S & F polymeric composite disc insulator, ball and socket type, Type B, Nominal System voltage 33 kV, highest system voltage 36 kV, visible discharge test voltage 33 kV, wet power frequency withstand voltage 45 kV, minimum total creepage distance 900 mm, minimum failing load 90 kN, of suitable size with galvanised steel stud pin, nut, washers complete all as specified and as directed.
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Re-fixing only Cross-Arms, Bracings, Supports, Clamps and Back Plates including applying One Coat of Aluminium over old painted surfaces including preparation of surfaces complete all as specified and as directed.
Disconnecting all electrical connection from Air Break Switch (GOD) vertical/Horizontal Type / DO fuse of 33KV capacity, cleaning all parts and greasing all moving parts for smooth functioning and replacement of fix contacts, flexible copper rod, GI nut, bolt etc complete all as specified and as directed.
S&F Aluminium Conductor Steel Reinforced (ACSR) Panther (sizes as ordered) and fixing on Electric Poles with binding to Insulators with Aluminium Binding Wire PVC insulated R, Y, B and Neutral black as in OH Conductors including Stringing, Tightening, complete all as specified and as directed. (NOTE : Cost of Binding Wire shall deem to be included in the QUOTED UNIT RATE).
S & F gang operated air break switch, three poles, outdoor type, nominal system voltage 33 kV, rated voltage 36 kV, rated normal current 400 Amps, rated frequency 50 Hz, rated one minute power frequency withstand voltage between (i) earth & poles 70 kV (rms) (ii) across the isolating distance 80 kV (rms), rated lightning impulse withstand voltage (i) to earth and between poles 170 kV (Peak) (ii) across the isolating distance 195 kV (Peak), Rated short-time withstand current 20 kA for 3 seconds, rated peak withstand current 50 kA for climatic conditions at the site, mechanically operated mounted on polymer insulator and steel frame with operating mechanism worked from ground level for current complete all as specified and as directed.
Supply and replace for DO fuse assembly, triple pole mounted on polymer HT insulator 6 Nos and MS galvanised steel frame rating upto 200 Amp, 33000 Volt complete with expulsion type fiber glass fuse carrier barrel type and including DO fuze and electrical connections, jumpering by ACSR conductor and connectors complete all as specified and directed.
S&F of D. O. fuse element for 33 KV line, 15 A with fire resistant ferrule complete all as specified and directed.
S&F of D. O. fuse barrel for 33 KV line, 15 A with fire resistant tube and joint with ferrule complete all as specified and directed.
Supply and fix metal oxide surge arrester without gap for AC system as per IEC 60099-4: 2014, outdoor type, polymer housing, single column and single phase construction, station class, low duty, nominal discharge current 10 kA, switching impulse discharge current 0.5 kA, repetitive charge transfer rating (Qrs) more than 1.0 C, thermal energy rating (Wth) more than 4 kJ/kV, nominal system voltage 33 kV, highest system voltage 36 kV, rated voltage of arrester 27 kV, continuous operating voltage 21.6 kV, temporary overvoltage (30.45 kV for 1 s, 28.50 kV for 10 s, 26.35 kV for 100 s), rated short circuit current 20 kA, low short circuit current 600 A, insulation withstand level (lightning impulse voltage 1.2/ 50 µs) 170 kV, lightning impulse residual voltage (8/20 µs) at nominal discharge current maximum 72 kV, switching impulse residual voltage (30/60 µs) at switching impulse discharge current maximum 56 kV, high current impulse withstand capability (4/10 µs) 100 kA, minimum creepage distance 900 mm complete all as specified and as directed.
Disconnecting HV/LV Connections of Transformer, testing their serviceability (Open and Closed circuit test) with the help of composite unit of Transformer 1000 KVA,33000/433V complete all as specified and as directed.
Dismantling of U/S bushing,gasket,brass spindle with nut,washers carefully without any damage to existing parts and labour for fixing new bushing complete to match with nut, washers etc., replacement of brass spindle for terminal on EHV side threaded complete and sealing the same with sealing material gasket/cork sheet of existing transformer 33/0.433 KV, 1000 KVA capacity complete all as specified and directed.
Dismantling of U/S bushing,gasket,brass spindle with nut,washers carefully without damage to existing parts and labour for fixing new bushing complete to match with nut, washers etc., replacement of brass spindle for terminal on LV side threaded complete and sealing the same with sealing material of existing transformer 33/0.433 KV, 1000 KVA capacity complete, all as specified and directed.
M&L for servicing/minor repairs / painting of 33 KV grid station made out of steels poles, channels, cross arms latice structure for 33/0.433 KV, transformer of capacity 1000KVA (02 Nos) having one feeder each complete and connected CT/PT, incl greasing for all moving parts, replacement of rusted / unserviceable nuts, bolts, washers, jumpers, PG clamps, T connector, clamps etc complete all as specified and directed. Note: (i)Contrator shall visit site before quoting rates for this item. (ii) Contractor shall apply for shut down of not more than three hours per day at least 7 days in advance. (iii) Painting shall be with two coats of aluminium paint on cross arms/ lattice structure/poles and with two coats of syntheticenamel paint for transformer after cleaning/scraching the surface thoroghly.
M&L for dehydration of transformer oil of transformer of capacity 1000 KVA 33 KV/0.433KV ,oil capacity-1400 Litre by means of Centrifugal Filtration Plant to acheive minimum turnover of 3 cycle or till die electric strength to achieved upto 50 KV at 4 mm gap and testing complete including all arrangement of T&P and electrical equipment and transport etc in presence of Engr-in-Charge complete all as specified and directed.
Supply and filling of new insulating transformer oil for make up of transformer of cap 33/0.433 KV during dehydration, confirming to IS 335/1993 and having dielectric strength of 50 KV at 4 mm gap complete all as specified and directed.
Supply & fix in repairs Breather Assembly filled with Silica Gel as approved and suitable for Transformer 01 MVA complete all as specified and as directed
Inspection/Servicing to outdoor VCB 33 KV 630 Amps of AREVA make with full functionality by doing following jobs including testing and commissioning to the entire satisfaction of Engineer-in-charge complete all as specified and directed. (a) Cleaning the external surface of bushing with CTC or liquid ammonia to remove the accumulation of dirt or any other deposits. Inspection of bushings and make sure that vibration due to break operation have not caused the bushings to move resulting misalignment of contacts. (b) Checking the vacuum interrupter assembly and contact Checking the alignment of contacts and setting the contact surfaces to bare firm and uniform pressure and adjust the gap as per manufacture tolerance. Badly potted contact needs to be replaced. (c) Checking of operating voltage watt mechanism terminals tripping arrangement for positive tripping. Contacts to be examined for their condition and operation. Dress the pitted contacts. (d) Inspecting all bolts, nuts pins and collar pins for tight and opened properly (e) Inspection cleaning and relubrication of circuit breaker (f) calibration of outdoor VCB 33 KV 630 Amps along with primary current injection test of 33 KV current Transformers (CTs) & Potential Transformer (PTs) and checking the electrical circuit for fault condition and proper functioning for testing of L&T relay MC61AnX at MRS 33/0.433 KV DSCC powerhouse including calibration of relay indoor control panel complete all as specified and as directed.
Supply and spread of lime (chunna) powder for the two pole structures / 33 KV Main Receiving Station yard complete all as specified and directed.
Supply & Repalcement of synthetic Rubber insulated mats 3.0 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
M & L for painting of chain link fencing arround the substation and steel angle poles, with two coat of silver paint after cleaning/scrapping the surface throughly incl main gate complete, and writing on main gate with font and size complete all as specified and directed.
M & L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT, 250 mm X 200 mm complete all as specified and as directed.
M &L for cleaning of sub station premises switch yard area for Cutting wild grass, bushes, unwanted vegetation removal of shrubs,debries, grass and vegetation upto required standard of inspection point of view complete all as specified and directed. Note: Cleaning the complete substation will be considered as one job
M&L for Chemical earthing as per 'ASHLOK" make model T-39 zinc coated safe earthing electrode (SEE) of 3 mtr length with inner pipe of 40 mm dia with min 80-100 micron coating filled with black fill compound mixed with soil and high specific gravity crystalline conductive mixture (CCM) of grade 'B' filled inside the earth electrode incl drilling of hole of 200 mm dia bore with boring machine up to 15 mtrs depth in hard rock and filling the bore hole with black cotton soil up to 17 mtrs level i.e. below the electrode bottom level, incl PCC earth pit and GI earth strip of 32x6 mm with GI tubing light grade for protection up to 7.5 mtrs complete all as specified and directed.
Material and labour for Earth continuity conductor or main earthing strip of 32x6mm galvanised iron fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as specified and directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron strip 32 x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviceable earthing set complete all as specified and directed. Notes: (i) main earthing strip from earth plate electrode to rest pont upto length of 7.5 meters length shall be deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if desired resistance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Supply installation and commissioning of DC chargeable battery bank of 48 VRLA(2V x 24) 100 AH. Batteries shall be made of closed type lead acid cells with VRLA type(48V) plates manufactured to confirmed to IS : 1652-1991 complete all as specified and directed.The capacity of batteries shall be- (i) Voltage - 36V (ii) Output at 27 degree- 100Ah at 10hrs discharge rate Note :- (i) MS angle iron frame to be deemed included in the quoted rate. (ii) Batteries connection in parallel will be done by contractor.
PRADEEP SISODIYA (BID ID -3210461)
PRADEEP TIWARI CONTRACTOR (BID ID -3206158)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .