Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹79.7 CrAccepted-AOC | ₹79.7 Cr Quoted ₹49.8 Cr | 1 | Accepted-AOC L-1 |
| 2 | 2₹50.3 CrRejected-Finance HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | ₹50.3 Cr | 2 | Rejected-Finance h |
| 3 | 3₹50.5 CrRejected-Finance | ₹50.5 Cr | 3 | Rejected-Finance h |
| 4 | Rejected-Technical | - | - | Rejected-Technical all techincal document are Not clae |
Tender Value
₹47.5 Cr
EMD Value
₹23.8 L
Closing Date
4 Jan 2024, 6:00 pmClosed
Executive Engineer Public Works Division Sangamner
Office of the Executive Engineer Public Works Division Sangamner
Construction of Mahasul Bhavan Building and Staff Quarters At. Shirdi Tal.Rahata Dist.Ahmednagar
2023_PWR_972067_2
PWD SGM/ Notice No.34 for 2023-2024-
Open Tender
Civil Works - Buildings
720 days
Tal.Rahata
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,540
₹23.8 L
Chief Engineer P.W.Region Nashik
20 May 2024
20 Dec 2023
8 Jan 2024
20 Dec 2023
4 Jan 2024
20 Dec 2023
29 Dec 2023
Amount
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metres. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre.) By Mechanical Means
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift from 1.5 metre to 3.0 metre) By Mechanical Means
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra. complete. (Lift from 1.5 to 3.0 metre) By Mechanical Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting excetra complete. (Lift from 1.5 metre To 3.0 metre.) By Mechanical Means
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, excetra. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming excetra complete. (Lift upto 1.5 metre). By Mechanical Means
Filling in plinth and floors with approved excavated material in 15 centimetre. to 20 centimetre Layers including watering and compacting excetra complete.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction excetra complete.
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting excetra complete.
Providing preconstructional antitermite treatment as per Indian Standards 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standards6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing excetra complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concretecolumns and steel stanchions excetra. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) excetra. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing excetra. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Crushed sand VSI Grade)
First Floor
Second Floor
Third Floor
Fourt Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concretebeams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing excetra complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Crushed sand VSI Grade)
First Floor
Second Floor
Third Floor
Fourt Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing excetra. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Crushed sand VSI Grade)
First Floor
Second Floor
Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Crushed sand VSI Grade)
First Floor
Second Floor
Third Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concretechajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Crushed sand VSI Grade)
First Floor
Second Floor
Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for Reinforced Cement ConcreteWaist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with Cement Mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing excetra complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Crushed sand VSI Grade)
First Floor
Second Floor
Third Floor
Providing and fixing in position Thermo Mechanical Treatment - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches excetra. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
First Floor
Second Floor
Third Floor
Providing second class Burnt Brick masonry with conventional/ Indian Standards type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering excetra complete.
Providing second class Burnt Brick masonry with conventional/ Indian Standards type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding excetra. Complete
First Floor
Second Floor
Third Floor
Providing second class Burnt Brick masonry with conventional/ Indian Standards type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering excetra complete.
First Floor
Second Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /Brick Bat masonry and or tying by binding wire excetra complete.
First Floor
Second Floor
Third Floor
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing excetra complete.
First Floor
Second Floor
Third Floor
fourt Floor
Providing internal cement plaster 20 milimetre thick in a single coat using Ready to use wall plaster to concrete, brick surfaces in all positions including scaffolding and curing. Providing groove at joint of Brick Bat.Masonry and concrete members complete.b) cement mortar 1:4 With Prior Approval of Concerned Superintending Engineer
First Floor
Second Floor
Third Floor
Fourt Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding excetra.complete.
First Floor
Second Floor
Third Floor
Fourt Floor
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 milimetre thickness or as required, in all position including preparing the surface, scaffolding excetra complete.
First Floor
Second Floor
Third Floor
Fourt Floor
Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding excetra.complete.
First Floor
Second Floor
Third Floor
fourt Floor
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 milimetre thick Mild Steel sheet fan hook box of size 180x100 milimetre with required depth with holes or notches as required, bottom and top sides of 1.6 mm Mild Steel sheet fixed with 3.5 milimetre diametre round headed screws together with 12 milimetre diametre Mild Steel bar bent to shape with hooked ends for fan hook and painting to exposed surface
First Floor
Second Floor
Providing flush grooved pointing with cement mortar 1:3 for brick work including scaffolding and curing excetra complete.
First Floor
Second Floor
Third Floor
Providing vee pointing with cement mortar 1:3 for stone / Brick masonry including scaffolding and curing excetra. complete
First Floor
Second Floor
Third Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in Cement Mortar1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with Cement Mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test excetra complete.
Second Floor
Providing water proof bedding for flooring of Bath and water closet 25 milimetre thick in Cement Mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test excetra complete.
First Floor
Second Floor
Providing waterproof plaster in water closet and bath 12 milimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing excetra complete. (Excluding Tiles) (As directed by Engineer in Charge)
First Floor
Second Floor
Providing waterproofing in water closet and bath including brick bat coba in all position including providing and laying 12 milimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cement mortar 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20 milimetre thick brick bedding in cement mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing excetra complete.
First Floor
Second Floor
Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre confirming to corresponding Indian Standards for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing excetra complete.
First Floor
Second Floor
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing excetra complete.
First Floor
Second Floor
Providing and laying vitrified rustic matt stone finish tiles having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to Indian Standards. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning excetra complete.
First Floor
Second Floor
Third Floor
Providing and laying vitrified stone effect finish tiles having size 590 to 605 milimetre x 590 to 605 milimetre of 8 to 10 milimetre thickness and confirming to Indian Standrads 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including required position laid on a bed of 1:4 cement mortarincluding neat cement float, filling joints, curign and cleaning excetra complete.
First Floor
Second Floor
Third Floor
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to Indian Standrad 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning excetra complete.
First Floor
Second Floor
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing excetra complete.
First Floor
Second Floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to Indian Standrads 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing excetra. complete
First Floor
Second Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar1:3 curing and cleaning excetra complete.(Including leather finished polishing to Granite Stone slab by continuous grinding in 4 coats)
First Floor
Second Floor
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning excetra complete.
First Floor
Second Floor
Third Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing excetra complete.
First Floor
Second Floor
Providing and fixing machine cut mirror polished 18 milimetre to 20 milimetre thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges excetra. complete . Both side polish
First Floor
Second Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite excetra complete. (Platform top size 5.00 metre x 0.60 metre and height is 0.75 metre)
First Floor
Second Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 milimetre thick for door frame/ dado/ window boxing excetra. On Cement Mortar1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, excetra complete.
First Floor
Second Floor
Third Floor
Providing patti/ band 100 milimetre wide on plastered surface 12 milimetre to 15 milimetre thick in Cement Mortar1:3 line and level including neat finishing scaffolding curing excetra complete.
First Floor
Second Floor
Providing patti/ band 150 milimetre wide on plastered surface 12 milimetre to 15 milimetre thick in Cement Mortar1:3 line and level including neat finishing scaffolding curing excetra complete.
Second Floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre x 40 milimetre x 5 milimetre with oil painting, excetra. complete
First Floor
Providing and fixing Country cut teak wood double or single leaf second class fully panelled door shutter with 35 milimetre thick style and rail with 25 milimetre thick panels with openable fan light as per detailed drawings. Excluding the door frame 60 milimetre x 100 milimetre stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats. (Excluding the door frame)
First Floor
Providing and fixing Country cut teak wood single leaf panelled door shutter without fanlight and 25 milimetre thick as per drawing consisting of Teak Wood top rail size 100 milimetre x 25 milimetre and bottom lock rail 200 milimetre x 25 milimetre insert pannel 12 milimetre thick commercial ply faced Teak Wood particle board with phenol formaldehyde synthetic resin (Generally confirming to Indian Standards InstitutionI 3097) excluding frame, including stainless steel fixture and fastening and Teak Wood beading to junctions of panelled inserts and as instructed by the Engineer in charge including 3 coats of oil painting excetra complete.
Providing and fixing Single leaf shutter of 35 milimetre thick, for solid core flush door, decorative type of exterior grade as per detailed drawings or as approved Laminates (Formica) on both faces venetians, all necessary beads, moulding and lipping, brass oxidized / aluminum with power coating fixture and fastenings ___ chromium plated handles on both sides and finishing excetra complete. (without frame)
First Floor
Second Floor
Third Floor
Providing and fixing 30 milimetre thick Poly Vinyl Chloride FLUSH L DOOR SHUTTER consisting of panel of hollow Poly Vinyl Chloride profile of 20 milimetre thickness consisting frame made out of Mild Steel tubes of 19 gauge thickness and size of 19 milimetre x 19 milimetre inserted inside the hollow section of stiles rails top and bottom rails and two 19 x 19 milimetre Mild Steel tubes inserted horizontally inside the hollow profile section using 4/5 milimetre sheet using screws hollow profile shall be lipped with 10 milimetre (5milimetre x2) thick x 20 milimetre width on stiles and rails using solvent cement. The inner panel shall be laminated with 5 milimetre thick termite proof waterproof plain /prelam Poly Vinyl Chloride sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening excetra. Complete as per direction of Engineer incharge, manufacturers specification and drawing.
First Floor
Second Floor
Providing and fixing of Casement fixed window of approved make with DGU. The extruded aluminium sections of Alloy 6063 tolerances confirming to DIN standard from approved raw material V2 / V4 as directed by Engineer in charge.
First Floor
Second Floor
Third Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 milimetre at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts excetra. complete. With colour Anodising without box
First Floor
Second Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 milimetre x 1.22 milimetre box type, 5 milimetre thick sheet glass louvers, of approved quality excetra complete.
First Floor
Second Floor
Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 milimetre stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 Kilogramload bearing capacity of trolley made out of 20 milimetre PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 milimetre stainless steel decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)
First Floor
Second Floor
Providing and fixing Mild Steel grill door 24 Kilogram/ One Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting excetra. First Floor
Second Floor
Third Floor
Providing and fixing mild steel grill work for windows, ventilators excetra. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
First Floor
Second Floor
Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres
Second Floor
Providing and fixing on walls/ ceiling/ floor 15 milimetre diametre chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed excetra complete.
First Floor
Second Floor
Third Floor
Providing and fixing on walls/ceiling/floor 20 milimetre diametre chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department or as directed excetra complete.
First Floor
Second Floor
Third Floor
Providing and fixing on walls/ ceiling/ floor 25 milimetre diametre . chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department or as directed excetra complete.
First Floor
Second Floor
Third Floor
Providing and fixing on walls/ ceiling/ floor 32 milimetre diametre chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department or as directed excetra complete.
First Floor
Second Floor
Third Floor
Providing and fixing on walls /ceiling/ floor 40 milimetre diametre chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department or as directed excetra complete.
Second Floor
Providing and fixing on walls/ ceiling/ floor 50 milimetre diametre chlorinated polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion excetra complete.
First Floor
Second Floor
Third Floor
Providing and fixing on walls/ ceiling/ floor 15 milimetre diametre unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department or as directed excetra complete.
First Floor
Second Floor
Third Floor
Providing and fixing on walls/ceiling/floor 20 milimetre diametre unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department or as directed excetra complete.
First Floor
Second Floor
Third Floor
Providing and fixing on walls/ ceiling/ floor 25 milimetre diametre unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department or as directed excetra complete.
First Floor
Second Floor
Third Floor
Providing and fixing on walls/ ceiling/ floor 32 milimetre diametre unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department or as directed excetra complete.
First Floor
Second Floor
Third Floor
Providing and fixing on walls /ceiling/ floor 40 milimetre diametre unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department or as directed excetra complete.
Second Floor
Providing and fixing on walls/ ceiling/ floor 50 milimetre diametre unplasticized polyvinyl chloride pipe with necessary fittings, remaking good the demolished portion excetra complete.
First Floor
Second Floor
Third Floor
Providing and fixing Poly vinyl chloride Rain water pipes of 110 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standards 13592-1992 including proper rainwater receiving recess with Poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40 milimetre from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge excetra complete.
First Floor
Second Floor
Third Floor
Providing and fixing in position unplasticized polyvinyl chloride ultra violet stabilized 110 milimetre outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement excetra. complete
Providing and fixing white Opal series European type wall-hung, of size 400 milimetre x 370 milimetre x 575 milimetre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 milimetre diametre Cast Iron. plug bend inlet pipe all fittings, cutting and making good walls, floors etc as directed by Engineer in charge.
First Floor
Second Floor
Providing and fixing 1st class white glazed earthenware Orissa Type water closet Pan 580 milimetre diametre including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 milimetre thick, 10 liter Poly vinyl chloride flushing cistern with all necessary pipe connection excetra complete.
First Floor
Second Floor
Providing and fixing white glazed earthenware Wash Hand Basin of 63centimetre x 45centimetre size including Bib cock stop tap brass heavy 15milimetre, brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including Poly vinyl chloride waste pipe and trap up to the outside face of the wall.
First Floor
Second Floor
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, excetra. Complete as directed by Engineer in charge.
First Floor
Second Floor
Providing and fixing White Glazed Earthenware full stall type Urinal with Poly vinyl chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diametre. poly vinyl chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall
First Floor
Second Floor
Providing and fixing 10 centimetre Poly Vinyl Chloride nahani trap with grating excetra complete.
First Floor
Second Floor
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut excetra complete.
First Floor
Second Floor
Providing and fixing C.P. wall mixer with provision for overhead shower with 115 milimetre long bend pipe and wall flange of approved make including necessary sockets/union nut excetra.complete.
First Floor
Second Floor
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut excetra complete.
First Floor
Second Floor
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut excetra complete."
First Floor
Second Floor
Providing and fixing 450 milimetre x 550 milimetre size superior type Belgium mirror with 16 milimetre diametre nickel plated towel rod excetra complete.
First Floor
Second Floor
Providing and fixing chromium plated towel rod 16 milimetre diametre and 75 centimetre. in length including all accessories complete.
First Floor
Second Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO and HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC and Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge.
First Floor
Second Floor
Third Floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, excetra.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.
First Floor
Second Floor
Third Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 milimetre diametre and vertical pipe of 38 milimetre diametre at 0.60 metre centre to centre or as required and horizontal pipes of 25 milimetre diametre in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diametre above newel post of 75 milimetre diameter excetra. complete (Prior approval of sample and brand by Executive Engineer is necessary before use)
First Floor
Second Floor
Third Floor
Providing and fixing 900 milimetre high Stainless steel 304 Grade Stainless steel railing with 40 milimetre diameter and 1.5 milimetre thick at top, 40 milimetre diameter and 1.5 milimetre thick vertical supports spaced at 1.5 metre center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe excetra. complete
First Floor
Second Floor
Third Floor
Glass fibre-reinforced concrete Cladding - Providing and fixing Glass Reinforced Concrete (G.R.C) n accordance to the dimensions mentioned in drawings of proved maked equivalent. While Portland Cement manufactured by 'JK Cement' or equivalent, Quartz, Fine Silica Sand, Allkali Resistant Glass Fiber manufactured by 'Saint Gobain' or equivalent, super Plasticisers manufactured by BASF or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by 'BAYFERROX'(Germany) or equivalent. The material casting should take place in synthetic Rubbe/FRP Mould manufactured by 'reckli' or equivalen. The fixing of jali should be 'Dry fixing' i.e to be done with stainless.
First Floor
Second Floor
Third Floor
Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. Reinforced Cement Concrete pardi/ Wall and all type of Interior, Exterior Compound wall and Gate excetra. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 milimetre/ 25 milimetre including scaffolding, fixing of screw, excetra. (As directed by Engineer in Charge)
First Floor
Second Floor
Third Floor
Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 milimetre x 40 milimetre weighing 0.39 Kilogram/m. at 60 centimetres centre to centre and fixed with ( 15 x 15 milimetre ) flanges weighing 0.119 Kilogram/m suspended on 6 milimetre diametre. mild steel rod weighing 0.22 Kilogram/m fixed on wall and beams including rounding of the edges with aluminium T of 50 milimetre x 40 milimetre weighing 0.39 Kilogram/m excetra. including all labour excetra complete.
First Floor
Second Floor
Providing and fixing false ceiling of 10 to 12 milimetre thick decorative boards of fibrous plaster of paris including scaffolding if necessary all architectural work like mouldings, cornices, coves, domes, cups as per detailed drawings and three coats of spray painting to boards excetra complete. (excluding frame work, runners and mild steel suspenders).
First Floor
Second Floor
Providing and fixing 15 milimetre thick eco-friendly densified edge calcium silicate false ceiling of approved texture of size 595 milimetre x 595mmilimetre in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gram/squaremetre including both sides) consisting of main T runner suitably spaced at joints to get required length and size 24X38 milimetre. made from 0.33 milimetre thick(minimum ) sheet, spaced 1200 milimetre center to center and cross T of size 24X28 milimetre made of 0.33 milimetre thick(minimum ) sheet to be interlocked at the middle of the 1200x600 milimetre panel to form the grid of size 600x600 milimetre resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 milimetre thick (minimum) sheet with the help of all plugs at 450 milimetre and laying 15 milimetre thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings , fixtures , smoke detectors excetra., wherever required. Main T runners suspended from ceiling with using Galvanized Iron slotted cleats of size 25x35x1.6 milimetre fixed to ceiling using 12.5 milimetre diametre And 50 milimetre long dash fasteners, 4 milimetre Galvanized Iron adjustable rods with galvanized steel levels clips of size 85x30x0.8 milimetre, spaced at 1200 milimetre center to center along main T bottom exposed with 24 milimetre of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings excetra complete.(currently this item should be used only for VIP cabins)
First Floor
Second Floor
Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 milimetre thick Aluminium Composite Panel sheet material consisting of 3 milimetre thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws,nuts,bolts, washers, cleats, weather silicon sealent,backer rods etc .overall weight of the Aluminium Composite Panel shall not be less than 7.5 Kilogram/ One Square Metre)
First Floor
Second Floor
Providing and fixing 100 milimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangements and lock. [Without chamber].
Providing and fixing 15 centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed stoneware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement ConcreteCover medium duty 140 Kilogramwith frame excetra complete.
Providing and constructing Brick Masonry inspection Chamber 90 centimetre x 45 centimetre including 1:4:8 Cement Concrete foundation, 1:2:4 Cement Concrete channels /half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, with Cast Iron lead cover of 75 Kilogramwith frame fixed in cement concrete.
Providing and laying machine cut machine Polished Kota stone flooring 25 milimetre to 30 milimetre thick and required width in plain/ diamond pattern on bed of 1:6 Cement Mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning excetra complete.
First Floor
Second Floor
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees excetra. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces excetra. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade excetra complete.
Third Floor
Providing and fixing Galvanized Iron Pre coated trapezoidal Metallic coloured sheets of 0.50 milimetre thickness (26 B.W.G.) of approved make for roofing without wind ties including fastening with galvanised iron screws and bolts and lead and bitumen washers as per drawing complete. Spec. – As directed by Engineer-in-charge.
Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 milimetre thick of 900 milimetre (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility and strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on Mild Steel structure (will be paid Separately) with 3 One Numbers self-drilling screws and trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing and direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12mm thick panels shall be used for a roofing height of upto 15 mtrs. Second Floor
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
Providing earth work in embankment with approved materials obtained from departmental land upto lead of 50m. including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness breaking clods, dressing to the required lines, curves, grades and section, watering and compaction with vibratory roller to achieve not less than 97 % of standard proctor density excetra. complete ( Material obtained from departmental Land)
Supplying hard murum/ kankar at the road site, including conveying and stacking complete.
Spreading hard murum/ soft murrum/ gravel or kankar for side width complete
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering excetra complete.
Providing and laying in situ / ready mix M30 Reinforced Cement Concrete of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete work of ballast walls, kerbs and box returns including scaffolding, compaction, formwork finishing and curing excetra complete. (excluding reinforcement, with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer with fine agreegates of required specifications ( VSI sand finely washed etc ) Reinforced Cement Concrete work of Ballast walls and Kerb
Providing, cutting, bending, hooking, tying and laying in position TMT FE 500 steel bars for reinforcement for all Reinforced Cement Concrete works as per detailed drawings excetra complete.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) milimetre Aggregate)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 milimetre) Aggregate)
Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 milimetre thickness of having a strength of 300 Kilogram/Square centimetre. of approved quality and shape on a bed of crushed sand of 25 to 30 milimetre thick including skirting joints and cleaning excetra. complete
Providing and laying in situ cement concrete M30 with tremix treatment for 200 milimetre thickness for flooring with groove cutting of 4milimetre wide and 20 milimetre deep with necessary refilling with bitumen excetra complete.
Conveying materials obtained from road cutting including all lifts, laying in layers of 20 centimetre to 30 centimetre breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard proctor density for a lead of 300 metre. to 500 metre. inclusive, from the site of excavation to the site of deposition as directed.
Providing and laying concrete pipes of I.S.NP. class of 300 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450 milimetre diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing excetra complete.
Providing and fixing 90 centimetre x 60 centimetre Granite plate engraving 10 centimetre Height letter, figures including painting the lefters/figures with approved colour and shade complete
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 milimetre thick including 1.5 Refractive index reflectorizing glass beads @ 250 gram/squaremetre .Thickness of 2.5 milimetre is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL and QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).
Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 milimetre and height of 10 milimetre Ramp provided to give width of 145 milimetre, width of ribs to be 55 milimetre laid at centre to centre distance of 35milimetre, with reflective glass beads @ 350 gram / One Square Metre. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials excetra complete.
Boring/drilling bore well of 300 milimetre diametre for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire and running charges of all equipments, tools, plants and machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized Poly Vinyl Chloride medium well-casing pipe of 150 milimetre diametre, conforming to IS:12818, including required hire and labour charges, fittings and accessories excetra. all complete, for all depths, as per the direction of Engineer in charge.
Providing expansion joints in Reinforced Cement Concrete framed structure (interior column) with plain premoulded filler 25 milimetre thick including fixing Teak Wood battens on both faces and finishing as directed excetra complete.
First Floor
Second Floor
Providing and fixing self supporting steel roofing system for a Godown or alike made up of structural grade steel sheet of 912 millimeter width ( tolerance + / - 2 millimeter ), moulded at site using mechanical press dies to the desired curve and shape to form 605 millimeter wide interlocking panels . The interlocking panels shall be pressed to close the seam forming water tight joints for a span of 28.75 meter having arch rise as 5.75 meter, arch length 33.92 meter. The base material made up of imported galvalume steel complying to ASTM A792 having base metal thickness of 1.40 millimeter ( tolerace + / - 0.02 millimeter ) with alloy coating AZ 150 and paint coating of regular modified polyster , top coat 25 micron and bottom coat 12 micron as perapproved colour , including fixing hangers , clamps excetra.as may be necessary of Proflex standard, including fixing sky light of 2 millimeter thick polycarbonate sheet of size 2' x 14' and turbo ventilator of 24'' diameter to be installed at every 30 feet along the length of roof including finishing , testing and cleaning excetra complete.
Providing and fixing lightening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 milimetre diametre 1.2 milimetre thick with multiple points head 1.2 metre. long ( Heavy Duty) welded or clamped to Galvanized Iron. pipe pole B grade 50 milimetre diametre of requiired length with Mild Steel round base plate 25 Centimetre diametre and 10 milimetre thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 centimetre diametre x 45 centimetre Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 centimetre with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 Kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanized Iron pipe 40 milimetre diametre 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.
Providing and fixing copper strip 25 milimetre wide and 3 milimetre thick for lightening conductor including fixing with screws required scaffolding excetra.complete Note- Lightening conductor and earthinf pits is not considered in this item
Design, supply, fabrication and erection of approved structural glazing using specially designed Vertical Mullion and HorizontalTransoms of Required size and as per architect's approved Grid work with aluminium rectangular sections to be fixed in masonary at interval of each floor on concrete slabwith 80 milimetre X 100 milimetre X 5 milimetre thick galvanized M and L angle fixed on wall side with raw bolt size of 10 milimetre X 90milimetre with necessary bolts and washer / nuts for plumb the line levels. the glass using Dow corning 995 strural sealant and GE silicon ( SSG - 4000) sub frame is visible from outside and grooves between the glass panes shall be filled with weather sealant of Dow corning 789 / GE Sil proof to made it air tight, waterproof and duatfree thus giving it a flush look outside. Glass will be 6 milimetre thick Glaverbel reflective type with heat strenghthened toughened. First Floor
Second Floor
Providing and Fixing in position, Acoustical Panelling made from 12 milimetre waterproofing Ply wood and 1milimetre laminate on, 50 x 50 milimetre Sal-wood frame of 600 x 600 centre to centre having wooden supports from wall of required length, in front of 1000 Gsm FR grade synthetic wool 50 milimetre thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint and Scaffolding, as per Architectural and Acoustical Design and Instructions and Complete in all aspects as directed by the engineer in charge. (Proscenium vertical stage border facing and Side wall columns)
Providing and Fixing in position Acoustical Doors along with 150 x 75 mm teak wood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm FR grade synthetic wool 50mm thick and 3mm Tecsound from both sides, 6mm promate fire board, 12mm waterproof ply and 1 mm laminate from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.) 4 no each leaf, with Door-closer (Dorma / Geze or eq.) including cost of required Cut-Outs, decorative mouldings / finishing-items / melamine polish and Scaffolding as per Architectural and Acoustical Design and Instructions and Complete in all aspects as directed by the engineer in charge (Door should match 1 Hr fire rating)
Providing and Fixing in position, Acoustical Ceiling made from seamless Saint Gobain Rigitone 8/18 or Knauf Solopanel 8/18 (big panels) on approved heavy duty Galvanized Iron frame, ceiling channels at 300 centre to centre, and intermediate channels not more than 1200 centre to centre, suspended with Hangers from Roof, in front of 1000 Gsm FR grade synthetic wool 50 milimetre thick, with Paint, including cost of required Cut-Outs, decorative mouldings / finishing-items and Scaffolding, as per Architectural and Acoustical Design and Instructions and Complete in all aspects as directed by the engineer in charge. (Part of auditorium ceiling)
Providing and fixing in position Stage flooring Made from 18 milimetre plywood 1200 x 2400 and 18 milimetre Teakwood planks 100 x 800 having tongue and grove on Sal-wood frame of 50 x 100 at 600 milimetre centre to centre on stage surface including cost of required Cut-Outs, decorative mouldings / finishing-items / polish excetra., as per Architectural and Acoustical Design and Instructions and Complete in all aspects as directed by the engineer in charge.
Providing and Fixing in position, 1000 milimetre wide Auto-glow Aluminium extruded strips on auditorium steps as per Design and Instructions and Complete in all aspects as directed by the engineer in charge. Make Prolit or Eq
Providing and Fixing in position, Under Deck insulation for metal deck using 1000 Gsm synthetic wool with fixed to deck using adhesive and chicken mesh. (Auditorium, Lobby for AC duct and green rooms)
Providing and Fixing in position, Table made from 12 milimetre waterproofing plywood, laminate from out side and polish inside as per given drawing and Instructions, Complete in all aspects as directed by the engineer in charge.
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fixing mild steel grill gate with angle iron frame 65 millimetre x 65 millimetre x 10 millimetre with iron bars at 150 millimetre Center to Centre and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram per Squaremetre.
Providing and fixing bituminous pad 25 millimetre thick for expansion joints in retaining wall, compound wall excetra complete.
Providing and erecting Y type barbed wire fencing with seven rows of wire with 2.45 millimetre diametre Galvanised Iron pipe ( Rezan/ concentina ire 0.75 millimetre diametre ) with hot dip and Galvanised Iron coated hooks as per drawing supported on Mild Steel angle 50 x 50 x 6 millimetre at 2.5 Metre centre to centre including fixing and fastening with wire, painting Mild Steel angles with one coat of red lead primer and two coat of oil paint excetra complete.
Providing and erecting chain link fencing 1.6 Metre height with Galvanzied Iron chain link of size 50 x 50 milimetre, 8 gauge thick and fixed 75 milimetre above ground level on vertical Mild Steel Angles of 40 x 40 x 6 milimetre size, includind excavating pits for foundation and embedded in Cement Concrete block of 1:4:8 mix of size 450 x 450 x 670 milimetre at 1.75 Metre centre to centre with iron bar 16 mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal Mild Steel Angles at top and bottom of 25 x 25 x 5 milimetre size and vertical Mild Steel flat 35 x 5 milimetre and 25 x 5 milimetre horizontal including cross support of 40 x 40 x 6 milimetre angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 milimetre including 3 coats of oil painting excetra complete.
Providing and constructing 75 milimetre. thick Modified Penetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 milimetre. stone metal layers 30% crusher broken metal + 70% Hand broken (by breaking rubble obtained by blasting) heating and spraying the bitumen of specified grade @ 2 Kilogram/squaremetre, spreading 12 milimetre.size chips compacting with three wheel static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 excetra complete. Including picking of existing Water Bound Macadam surface. (VG-30 bulk bitumen rates are considered to arrive at rates)
Open Graded Premix Surfacing- Providing and Laying OGC 20 milimetrethickness composed of 13.2 milimetre to 5.6 milimetre aggregates premixed with bituminous binder transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant with SCADA, Paver and Vibratory roller ( Over Modified Penetration Macadam Surface) (VG-30 bulk bitumen rates are considered to arrive at rates)
Providing bituminous Type A liquid seal coat on bituminous surface including supplying all materials and bitumen of specified grade preparing existing road surface, heating and applying bitumen @ 0.98 KgSqm. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT. excetra complete. (VG-30 bulk bitumen rates are considered to arrive at rates)
GARDEN SOIL : Supplying on site garden soil well sieved 90% to pass through I.S.sieve of 10mm size free from stones rubbish like dried grass roots and other such materials. The soil should be fresh from quarry. The colour of the soil generally be red.The soil will be measured by measuring box. (Farma). Item includes royalty charges. Transporting loading and unloading excetra. (lead charges per 20 k.m considered)
Preparing Instant Lawn: - Excavating the ground to a required depth of 20cms, removing and conveying unwanted stuff to a required distance as directed. Filling fresh garden soil / silt and manure in excavated area in 3:1 proportion to a height of 20cms. Mixing garden soil and manure thoroughly well, leveling, with required slope light watering on previous night. Planting required variety of lawn grass as directed and maintaining till well established by watering, weeding, clipping, rolling excetra complete.
Planting small and medium size ornamental / Flowering Plants - Digging pit with size 0.6 metre x 0.6 metre x 0.6 metre removing and conveying unwanted stuff to a required distance as directed. Filling the pit with fresh garden soil and Farm Yard manure upto a height of 0.60 Metre in 3:1 proportion. Mixing soil and manure thoroughly well, levelling, watering previous night, planting one to two year old healthy plant saplings as per specifications. Maintaining till well established by watering, stirring of soil and manure, replacing of casualties excetra complete.
Planting large flowering/Shady trees. (Height to 2 Metre.)- Digging pit with size 0.9 metre x 0.9 metre x 0.9 metre removing and conveying unwanted stuff to a required distance as directed Filling the pit with approval excavated material uplo a height of 0.30 metre and remaining height of 0.60 metre. with fresh garden soil and manure in 3:1 proportion. Mining soil and manure thoroughly well, levelling, as directed, watering previous night, planting two to three year old minimum 2.0 metre.height, healthy trees sapling as per specifications. Maintaining till well established by watering, weeding, stirring of soil sinking replacing of casualties excetra complete.
Preparing flower Bed :- Excavating the ground to the required depth of 30 centimetres, Removing and conveying unwanted stuff to a required distance as directed, Filling fresh garden. soil and manure in excavated area in 3:1 proportion to a required height of 30 centimetres Mixing garden soil and manure thoroughly well, levelling, watering on previous night. Planting seedlings of required annuals 25 centimetres. apart apart as maintaining till well established by watering, weeding, stirring replacing of casualities excetra complete.
Preparing Edging or Border :- Excavating the ground to a required depth of 20 centimetres. in the required area, removing and conveying unwanted stuff, rubbish to the required distance as directed. Filling the excavated part with the fresh soil and manure in 3:1 proportion to a required height to 20 centimetres Mixing, levelling, watering the same. Planting rooted edging/border plants at distance of 20 centimetres. apart watering, weeding, stirring of soil replacing casulties pruning if necessary excetra complete.
Preparing Shrubbery:- Excavating the ground to a required depth of 30 centimetres Removing mbbish and conveying unwanted stuff to a required distance as directed. Filling fresh garden soil and manure in excavated area in3:1 proportion to a height of 30 centimetres.‘ Mixing garden soil and manure thoroughly well, leveling, watering on previous night. Plaiiting well, levelling, watering on previous night. Planting well developed shrubs plants, 0.50 metre height, 0.45 metres, apart as dircted and maintaining till well I established by watering, seedings, Stirring replacing, replacing casualatie excetra.complete. (R.A. No. 8)
Providing and fixing table in SDM/ADC of hight 0.77 metre with 6 drawers and 1 shutter compartment made up of frame work of 12mm thick I.S.710 grade marine plywood confirming to I.S.I.710 and 18 milimetre thick thick I.S.710 grade marine plywood confirming to I.S.I.710 and all exposed surfaces of 6 milimetre thick thick I.S.710 grademarine plywood confirming to I.S.I.710, Inner and outer exposed surface covered with laminate of approved colour, Teak wood for key board drawer hand rest, both side drawers and shelves with shuuter including necessary hardware like cable manager, stailess steel Handles, magnet catchers, drawer Chanels, Locks labour excetra. complete as directed by Engineer in charge.Sample available at the site. 1st FLOOR
2nd Floor
Providing and fixing Side drawer of hight 0.77 metre with 1 drawers and 2 shelves made up of frame work of 18 milimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 and all exposed surfaces of 6 milimetre thick I.S.710 grademarine plywood confirming to I.S.I.710, Inner and outer exposed surface covered with laminate of approved colour, including necessary hardware like 100 milimetre long stailess steel Handles, magnet catchers, Locks , labour excetra. complete as directed by Engineer in charge.Sample available at the site. 1st FLOOR
2nd Floor
Providing and fixing Back runner table of hight 0.77 metre with shutters made up of frame work of 12 milimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 to 18 milimetre thick I.S.710 grade marine plywood confirming to I.S.I.710, Inner and outer exposed surface covered with 1 milimetre thick laminate of approved colour, including necessary hardware like 100 milimetre long stailess steel Handles, magnet catchers, Locks , labour excetra. complete as directed by Engineer in charge. Sample available at the site. 1st FLOOR
2nd Floor
Providing and fixing Executive Table for Judge / Tahasildar of Hight 0.88 metre with 5 drawers and one shutter compatment made up of frame work with 12 millimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 to 18 milimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 and 6 milimetre thick I.S.710 grademarine plywood confirming to I.S.I.710 all exposed surfaces covered with 1 milimetre laminate of approved colour and top provided with 12 milimetre thick clear glass over red velvet cloth bordered with Teak wood moulding 100 x 12 milimetre melamine polish and melamine to all exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour excetra. complete as as directed by Engineer in charge.as per Sample available at the site. 1st FLOOR
2nd Floor
Providing and fixing single table in of Hight 0.77 metre with single drawer and single shutter compartment made up of frame work with 18 milimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 and 6 milimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 all exposed surfaces covered with laminate of approved colour, primer and oil painting to all exposed surfaces, melamine to all exposed lipping patti including surface termite treatment to all plywood, necessary hardware, labour excetra. complete as per Engineer in charge.as per Sample available at the site 1st FLOOR
2nd Floor
Providing and fixing storage of top width 0.40 metre with shelves and shutters made up of frame work with 18 milimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 with laminate of approved colour, and 12 milimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 for shelves,all exposed surfaces covered with 1 milimetre laminate of approved colour, including surface termite treatment to all plywood, necessary hardware, labour excetra. complete as directed by Engineer in charge.as per Sample available at the site 1st FLOOR
2nd Floor
Providing and fixing in position Meeting hall table of hight 0.77 metre in video conference room made up of 3 millimetre to 18 millimetre thick thick I.S.710 grade marine plywood confirming to I.S.I.710 make (Century, Comillimetreander, Biz, excetra. ) for sides and table top and internal surfaces finished with Formica approved make as directed by the Engineer in Charge including decorative moulding in required position drawer slider ( telescopic channel make of Solo, Polo and such other company ) knob, handles required multipurpose lock complete as per detailed drawings and as directed. 1st FLOOR
2nd Floor
Providing and fixing table in Court Hall for advocate of hight 0.77 metre made up of 18 millimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 1 millimetre laminate of approved colour fitted on exterior surfaces and fitting with decorative Teak Wood blusters in the front corners including surface termite treatment to all plywood, necessary hardware, labour excetra. complete as per directed by Engineer in charge. as per Sample available at the site. 1st FLOOR
2nd Floor
Providing and fixing Wardrobe 0.72 in width, made up of 18 millimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 with laminate with shelves, Mirror, towel rod, including book shelf shutter with 10 kologramme hydraulic pipe with approved quality with necessary fittings nails, screws, handle excetra. complete as per directed by Engineer in Charge.as per Sample available at the site 1st FLOOR
2nd Floor
Providing and fixing in position partition for corporate cabins in court office made up of Bracing of 19 millimetre 3 piece I.S.710 grademarine plywood confirming to I.S.I.710 0.25*0.25 metre Partition and laying 9 millimetre thick I.S.710 grademarine plywood confirming to I.S.I.710 make ( Century, Commander, Biz, excetra.) on Bracing and exposed parts are covered with formica finished and top with 12 millimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 excetra. complete as directed by engineer in charge as per Sample available at the site 1st FLOOR
2nd Floor
Providing and fixing acoustic panelling to wall in Glass wool / Racron and perforated Acostic board with 10 millimetre foam with Fabric panels for Acoustic treatment purpose excetra complete. ( Sample to be got approved from Exe. Engineer before use ) Spec. No. As directed by Engineer in charge. 1st FLOOR
2nd Floor
Providing and fixing 12 millimetre glass in position with all necessary hard wears , excetra complete as per detailed drawing and design attached including cost of all materials, lead , labours, necessary fidtures and fastening,Painting excetra. complete as directed by Engineer in charge..as per Sample available at the site 1st FLOOR
2nd Floor
Providing and fixing wall panelling in court hall with door (without accesories) made up of 6, 12, 18 milimetre thick I.S.710 grademarine plywood confirming to I.S.I.710 covered with 1 milimetre with laminate of approved colour including necessary hardware, labour excetra. complete as per directed by Engineer in charge. as per Sample available at the site 1st FLOOR
2nd Floor
Tea Table 900mm X 750mm X 450mm for Mild Steel ante chamber Providing And Fixing Of Tea Table 900mmX 750mmX 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick I.S.710 grademarine plywood confirming to I.S.I.710. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica excetra. 1st FLOOR
2nd Floor
Providing and fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (centimetres) Breadth (centimetres): 100 (centimetres)Height (centimetres): 100 (centimetres) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat 1st FLOOR
2nd Floor
Providing Executive Chair GODREJ KAREENA MID BACK CHAIR 9PO2A/EXECUTIVE/ WORKSTATION /LEATHERITE /REVOLVING OFFICE GODREJ INTERIO) (GODREJ INTERIO KAREENA MID BACK CHAIR 9PO2A) for Judicial Officer and Senior staff with pedastale base Aluminium Die Cast Chrome Finish With Nylon Twin Caster Wheels Minimum Of 50-70 milimetre Diameter, arm rest material of pu foam bonded chrome coted, Seat material of PU Foam Covered With pure leatherite, hieght adjustable back type, knee tilt synchronic type chair, with one year Warrantee period as approved by Engineer in Charge. 1st FLOOR
2nd Floor
Providing Executive Chair Godrej Ace Visitor Chairs-Office (GODREJ INTERIO) (Godrej Ace Visitor Chairs-Office), for Judicial Officerand Senior staff having Seat made of padded with polyurethane foam and Backrest made of Mesh with support of -injection moulded polypropylene, Frame Material ot chrome on Ms antilever frame type, Foam Used in Seat with Plastic Net cover, with one year Warrantee period as approved by Engineer in Charge. 1st FLOOR
2nd Floor
Providing Executive Chair GODREJ INTERIO REVOLVING CHAIR With ARM central tilt (GODREJ INTERIO) (Godrej Thrive Chair) having Pedastale base of Glass Fibre Nylon with ABS NylonTwin Caster Wheels Minimum 5 NUMbers of 50 milimetre Size with Proypylene material arm rest, chair shall be with PU foam covered with mesh fabric, push back type with one year Warrantee period as approved by Engineer in Charge 1st FLOOR
2nd Floor
Providing and Fixing Nil Kamal Shell Chairs has U pholstered seat insert, Pneumatic seat height swivel Back features, designed-in lumbar support, Polymer seat and back shell with padded upholstered seat, 7/16-inch solid steel rod fixed arms, and frame as directed by Engineer in Charge 1st FLOOR
2nd Floor
Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. 1st FLOOR
2nd Floor
Providing and fixing Wall Paper including adhesive to stick As directed by Engineer in charge 1st FLOOR
2nd Floor
providing and Fixing Rollar Blinds AMI Make or approved make and shade of 38 centimetres round Aluminium channel with Black out fabric and telting with chain(Ball) system with all necessary fixtures and fitting etc .complete. (Sample to be final by Engineer In-charge prior execution of work) 1st FLOOR
2nd Floor
Providing and Fixing Steel Letters with 1" thick, height 300 to 500 millimetre on wall including scafolding, screwing and buffing if necessary excetra. complete as per directed by Engineer in Charge 1st FLOOR
2nd Floor
Double Faced Mobile Unit for Compactor 2150 milimetre H x 2745milimetreW x 900milimetreD Providing and fixing Double Faced Mobile Unit for Compactor 2150milimetreH x 2745milimetreW x 900milimetreD - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 milimetre thick Mild Steel Sheet Size of Channel 25milimetre x 100milimetre x 45milimetre. GUIDE RAILS : The guide rails shall be made out of 28milimetre Bright bar placed on 1.2 milimetre thick Mild Steel Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition excetra. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 Kilograms. VERTICAL PANEL : Vertical panel consists of the front, Centre and rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel and designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor and does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth and effortless movement. Entire mechanism or gear and sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm. DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque and free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification and retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns). 1st FLOOR
Single Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 457mmD Providing and fixing Single Faced Mobile Unit for Compactor 2150mmH x 2745mmW x 457mmD - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 mm thick MS Sheet Size of Channel 25mm x 100mm x 45mm. GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 mm thick Mild Steel Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition excetra. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 Kilograms. VERTICAL PANEL : Vertical panel consists of the front, Centre and rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel and designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor and does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth and effortless movement. Entire mechanism or gear and sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm. DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque and free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification and retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns). 1st FLOOR
Single Faced Fixed Unit for Compactor 2150milimetreH x 2745milimetreW x 457milimetreD Providing and fixing Single Faced Fixed Unit for Compactor 2150milimetreH x 2745milimetreW x 457milimetreD - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 milimetre thick Mild Steel Sheet Size of Channel 25milimetre x 100milimetrex 45milimetre. GUIDE RAILS : The guide rails shall be made out of 28milimetre Bright bar placed on 1.2 milimetre thick Mild Steel Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition excetra. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 Kilograms. VERTICAL PANEL : Vertical panel consists of the front, Centre and rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel and designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brought together, central lock when operated gets locked with the floor and does not allow access to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth and effortless movement. Entire mechanism or gear and sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000mm x 200mm x 60mm. DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque and free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification and retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns). 1st FLOOR
Providing and Fixing Storge Rack of size 1.50 X 0.45 X 2.44 metre with verticle support members in mild steel angle 40 X 40 X4 milimetre and shelves in 16 Gauge CR sheets fitted to supports in nuts and bolts and verticle supports and shelves powdered coated of approved colour a as approve by Engineer in charge. 2nd Floor
Book Case with Glass Shutter @ 825Lx300Dx1650HT Providing and Fixing of Book Case with Glass Shutter @ 825L x300D x1650HT : To be made out of complete body and in 0.7 mm thick CRCA and Shutter in 1.2 mm thick CRCA with glass pannel in Powder coating finish as per drawing 1st FLOOR
2nd Floor
Providing and Fixing Godrej Storewel Plain 4sh, made from prime quality CRCA Steel With anti termite treatment. Size:- 1742 x 914 x 320 millimetre ( H X W X D ) As directed by Engineer in charge. As per SSR wording 1st FLOOR
2nd Floor
Providing and fixing Judges Chair at of overall size 1.15 x 0.60 x 0.50.metre at Bottom Burma Teak wood Support of 80 x 80 millimetre hand rest is to provided, Cushioned back rest and seat in 50 millimetrethick high density foam with Melamine polish and All as per directed by Architect's Drawing and Instructions of Engineer in Charge. 1st FLOOR
2nd Floor
Providing and fixing Stool made out of mild steel Pipe Powder Coating Finished 18 millimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 Finished with Laminated 1.5 millimetre thk size of Stool 0.45 X 0.45 as per directed by Engineer in charge. 1st FLOOR
2nd Floor
Providing and fixing Writing Desk work of 6,12,18 millimetre thick I.S.710 grade marine plywood confirming to I.S.I.710 all exposed surface shall be covered with 1 millimetre laminate including necessary hardware, labour excetra. complete as per directed by Engineer in charge. 1st FLOOR
2nd Floor
Providing and fixing Dining table in Ante Judge's Chamer of size 0.77 x 0.80 x 0.76 = 1 No. of 18 millimetre. thick I.S.710 grademarine plywood confirming to I.S.I.710 and 12 millimetre thick I.S.710 grademarine plywood confirming to I.S.I.710 with 1millimetre. laminate fitted on exterior surfaces as per directed by Engineer in charge. 1st FLOOR
2nd Floor
Providing and fixing foot rest work of 6,12,18 millimetre thk thick I.S.710 grademarine plywood confirming to I.S.I.710 all exposed surface shall be covered with 1 millimetre laminate including necessary hardware, labour excetra. complete as per directed by Engineer in charge. 1st FLOOR
2nd Floor
Providing and fixing Notice Board outside of Court Hall of size 1.22 x 1.22 x 0.20 with 1 milimetre laminate on external surfaces and 5 milimetre plain glass with handles and lock, soft board and blazer cloth fixed on the inside back excetra. complete as directed by engineer in charge 1st FLOOR
2nd Floor
Providing and Fixing in position, Carpet more than 800+ gsm, made with100% stain proof fibres of approved make along with 5mm underlay as per Architectural and Acoustical Design and Instructions and Complete in all aspects including all materials labour,finishing excetra complete
1st FLOOR
2nd Floor
Providing low back chair in mild steel pipe frame with powder coating at seat and back in powder coated and seat and back powder coated perforated mild steel sheet with P.U. arm rest as directed by Engineer in charge. 1st FLOOR
Providing and fixing running table of size 2.89 X 0.60 metre and heiglht of 0.77 metre with side compartmnts (drawer and shelve with shutter) made up of frame work of 12 to 18 milimetre thick I.S.710 grademarine plywood confirming to I.S.I.710. outer exposed surface covered with Iamilimetre thick laminate of approved colour, primer and oil painting to all exposed surfaces. inc luding necessary hardware like 100 milimetre long stailess steel 1Handles. magnet catchers, Locks, labour elc. complete as directed by Engineer in charge. 1st FLOOR
2nd Floor
Providing and Fixing in position 150milimetre in height Box Platform with frame of 31.5milimetre thk Plywood Plank at short span and 19mm thk Plywood Plank at long Span at 150milimetre centre to centre on both sides and top surface of it, made with 3 milimetre to 19 milimetre Waterproof plywood approved quality make (Like Greenply,Asean,\Century, Commander, Biz,excetra.) and exposed faces are finished with Laminate of approved shade sticked with approved quality glue of Fevicol make and abrotape including decorative moulding and approved quality nails, screws,complete as per detailed drawings and as directed by Engineer in Charge 1st FLOOR
2nd Floor
Providing and fixing Judge's partation with side gates in court hall of size 4.20 X1.65 of 18milimetre. Thk Gurjan ply and 12 milimetre thk commercial Gurjan ply with 1 mm laminate fitted on exterior surfaces and teak wood balusters and Teak Wood ball for decoration, Teak Wood balusters 0.07 X 0.07 X 0.60 and moulding on railing top polished in mirror finish melamine polish including surface termite treatment to all plywood, necessary hardware, labour excetra. complete as per design and drawing as directed Architect's drawing and instuction of Engineer in charge. 1st FLOOR
2nd Floor
Providing and fixing 3 to 5 milimetre thick polyvenyl venyl chloride flooring including leveling the base with white cement including pasting with appropriate material cleaning the surface excetra. Complete 1st FLOOR
2nd Floor
Providing and fixing computer keyboard tray with all fixtures of approved make excetra complete as directed by Engineer Incharge. 1st FLOOR
2nd Floor
Providing and fixing Furniture in 18 milimetre thick I.S.710 grademarine plywood confirming to I.S.I.710 1st FLOOR
2nd Floor
Providing and fixing Furniture in 12 milimetre thick I.S.710 grademarine plywood confirming to I.S.I.710 1st FLOOR
2nd Floor
Providing and laying and Pasting for Furniture 1.5 milimetre Thick Formica 1st FLOOR
2nd Floor
Providing Internal Elecrification For The Proposed ( P + 2 FLOORS) Central Admin Building At- New Mahsul Bhavan Building Shirdi,Tal-Rahta,Dist-Ahmednagar ( Part A - Sub Work No. 01 ) Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-10]
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-12]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting mains with 4x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]
Supplying and erecting green colour earthing with 1x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-33]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-17]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-21]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2]
Supplying and erecting modular type D.P. switch 32A with indicator duly erected on provided plate and box with wiring connections complete. [1-6-8]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11]
Supplying and erecting modular type buzzer 220 / 250V duly erected on provided plate and box with wiring connections complete. [1-6-19]
Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-35]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-36]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-39]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-40]
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-5]
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-6]
Point wiring for independent plug in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E ) FRLSH grade copper wire modular type switch earthing and required accessories as per specification No WG-PW/SW [1-7-14]
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW [1-7-15]
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW [1-7-16]
Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26]
Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 770 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-2]
Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 1500 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-4]
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing polystyrene diffuser having system lumens output of Min. 3600 Lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-7]
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W. [2-1-13]
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface. [2-1-14]
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-16]
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18]
Supplying and erecting inverter LED batten 20W tube light fitting with polycarbonate housing heat sink integrated HF electronic driver Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt CRI>80 CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. [2-1-22]
Supplying and erecting Electronic type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply. [2-3-15]
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-14]
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21]
Supplying and fixing anchor type fastener fan hook with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. [2-11-2]
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. [2-11-5]
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. [2-11-6]
Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC [3-3-10]
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) [3-5-1]
Supplying, installing, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS (30 Min.) [3-7-3]
Supplying, installing, testing and commissioning of 2kVA capacity online pure sine wave with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS (30 Min.) [3-7-2]
Supplying and erecting 12V/17Ah -18Ah SMF battery with battery terminal wire duly charged with 12 months warranty complete ( For 3 KVA ) [3-8-8]
Supplying and erecting 12V/26Ah SMF battery with battery terminal wire duly charged with 24 months warranty complete (For 2 KVA) [3-8-9]
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-1]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 8 ways / phase (24 poles) with door 1.2mm thickness surface/ flush mounted IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-2]
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8]
Supplying and erecting triple pole and neutral distribution board (TPNDB) 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) with door 1.2mm thickness surface/flush mounted on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 [5-4-16]
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-9]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Providing and erecting 4 Pole MCCB 415V 200A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-2]
Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1]
Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-13]
Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12]
Supplying, erecting and marking DPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-6]
Supplying, Erecting and Commissioning of 2 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-1]
Supplying, Erecting and Commissioning of 4 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-4]
Supplying, Erecting and Commissioning of 4 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-5]
Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10]
Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11]
Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9]
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. [7-11-6]
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-2]
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. [9-2-5]
Supplying and erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. [9-3-1]
Supplying and erecting 75 kVAr 440 V 3 phase 50 Hz. Contactor Logic & Intelligent Relay micro APFC passive filter panel consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC [6-7-4]
Supplying, erecting and marking SPMCB 0.5A to 5A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-1]
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2]
Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green 230 / 250V on provided box / panel with necessary material wiring & connections etc. [6-5-5]
Supplying and erecting LED type indicating pilot lamp with LED colour blue 230 / 250 V on provided box / panel with necessary material wiring & connections etc. [6-5-6]
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display external CT operated calibrated for suitable to operate on 500V 0 to 1000A having accuracy class of 0.5 AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. [6-3-7]
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. [6-3-8]
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1]
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB [6-2-11]
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB. [5-11-14]
Supplying and erecting 20m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. [1-8-25]
Supplying installing testing and commissioning of Supply Installation Testing and Commissioning of LCD of projector of specification brightness 5000 Lumens LCD panel Size 0.64 I nch (16 10 aspect ratio) Resolution 1920*1200 pixels (WUXGA Full HD) Lens 1.6x Manual zoom (Throw Rato 1.09-1.77.1) Manual focus F1.6.2.12 Screen Size Diagonal 30-300 inch Optical Axis Shift 0 to +44% from centre of screen (Manual) Keystone Correction Range Vertical Maximum +/-25 degree Horizontal +/-30 degree contrast ratio 16000 1 Input port 2xHDMI 2XVGA 1XAUDIO IN 1X AUDIO OUT LAN and 2x USB Built in speaker 10 Watt (Non CSR ) [21-3-1]
Supplying installing testing and commissioning of Supplying and erecting Universal Ceiling Mount Bracket for Projector (Non CSR )[Non CSR]
Supplying installing testing and commissioning of Motorized Screen of Size 120 inch Diagonalwith Remote (Non CSR )[Non CSR]
Providing Transformer System For For The Proposed ( P + 2 FLOORS) Central Admin Building At- New Mahsul Bhavan Building Shirdi,Tal-Rahta,Dist-Ahmednagar ( Part A - Sub Work 02 ) Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. (0.1 x 0.3 x 2 = 0.66 0.3 x 0.3 x 2 = 0.18 0.1 x 0.3 x 2 = 0.66 Total = 1.5 sqm Sheet Weight = 12.55 Grand Total 12.55 x 1.5 = 18.825 kg for One Box.) [6-1-19]
Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982 [6-1-15]
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 3x240V 50 Hz with optical & RS 232 port backlit LCD measure & display trivector energy load survey TOD tamper detection & logging power ON /OFF events instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs. [6-3-5]
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-21]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-22]
G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-3]
Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ ( 9 Mtr X 6 Nos. = 54 Mtr ) [8-1-13]
Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm and fixed on pole with MS clamp of 80x10 mm nut bolts washers complete as per specification no. OH-PL/VCA [8-3-12]
Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA [8-3-14]
Supplying and erecting bracket for guarding of HT OH Line made from channel iron 1600mm in length and 75x40x6mm. erected on pole complete as per specification no. OH-PL/VCA [8-3-15]
Supplying and erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps nut bolts etc. complete as per drawing. [8-3-17]
Supplying and erecting end pole D. P. Structure for 11/0.415 kV 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100mm x 116 mm x 11 m Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos.200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set L.A. A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box Transformer Belt etc.as per drawing (min. 124 Kg. iron work) with necessary clamps Nut-bolts. V cross arm top clip insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. [8-3-26]
Supplying and erecting ACSR conductor of size 6/1-2.59 mm complete. (Weasel) (127.7 kg/km) as per specification No. OH-CON/ACSR [8-4-7]
Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line complete as per specification no. OH-INS/DI [8-5-6]
Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line complete as per specification no. OH-INS/PN [8-5-9]
Supplying and erecting G.I. stay set for poles including loop insulators at inaccessible height with anchor plate 300x300x6 mm. straining screws G.l. stay wire 7/8 SWG G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. [8-6-2]
Supplying and fixing MS base plate 30x30x0.6cm size fixed to the pole base either by welding 12mm dia fixed at position. [8-6-15]
Supplying and erecting guarding lace for HT OH line with 8SWG G.l. wire to protect the HT OH line with binding wire of 20SWG G.l. wire for 75mm section on either side. [8-6-18]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4]
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. (0.102 kg/m x 600 m = 61.2 Kg) [9-2-5]
Supplying, installing, testing and commissioning of 3 phase 11/0.433 kV 50 Hz. 160 kVA Mineral oil immersed and naturally cooled outdoor type aluminium wound Non-sealed transformer delta/star connected with additional neutral brought out on load side temperature rise should not exceed 40? by thermometer in oil and 45? by the resistance method in winding at full load rating using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +2.5 to -5 in steps of 2.5% having 4 number of tap positions with standard accessories complete with test certificate with losses below 670 Watts at 50% load 1950 Watts at 100% load as per IS 1180 (part 1) 2014 with necessary permissions of Electrical Inspector as per specification no SS- TR-NSL. [10-1-4]
Supplying and erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.). [10-6-21]
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1 3 6 cement concrete 20 x 25 mm stone metal (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered with necessary curing and finishing complete. (above 6 m to 9 m poles) [16-3-3]
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1 3 6 cement concrete (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). [16-3-6]
Providing LV System For The Proposed ( P + 2 FLOORS) Central Admin Building At- New Mahsul Bhavan Building Shirdi,Tal-Rahta,Dist-Ahmednagar ( Part A - Sub Work No. 03 ) Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]
Supplying and erecting modular type T.V. socket single outlet duly erected on provided plate and box with wiring connections complete. [1-6-14]
Supplying and erecting modular type telephone socket one gang with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-15]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected. [1-6-26]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-34]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-35]
Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-1]
Supplying and erecting 10 pair 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier polythene sheathed G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW [1-8-13]
Supplying and erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW [1-8-18]
Supplying, Erecting and Commissioning of MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW [1-9-1]
Supplying, Erecting and Commissioning of 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW [1-9-11]
Supplying, Erecting and Commissioning of 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW [1-9-18]
Supplying, Erecting and Commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete. [1-9-26]
Supplying, Erecting and Commissioning of push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. [1-9-29]
Supplying, Erecting and Commissioning of IP telephone instrument as per specification complete. [1-9-30]
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1]
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC [1-10-7]
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC [1-10-16]
Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC [1-10-18]
Supplying, fixing, and configuring 8-ports managed gigabit Layer-2 switch 10/100/1000 base-T POE smart switch plus 2 SFP erected in provided rack complete. [1-11-2]
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port ethernet managed switch with web view/CLI 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS [1-11-4]
Supplying, fixing, and configuring broadband ADSL router with all accessories on provided rack as per specification No. WG-NWC/ADSL [1-11-17]
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1]
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO [1-12-2]
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP [1-12-4]
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK [1-12-17]
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK [1-12-18]
Providing Lift For The Proposed ( P + 2 FLOORS) Central Admin Building At- New Mahsul Bhavan Building Shirdi,Tal-Rahta,Dist-Ahmednagar (Part A - Sub Work No. 04 ) Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. [1-6-29]
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-5]
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-6]
Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26]
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty. [2-1-15]
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18]
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-13]
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21]
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying, Erecting and Commissioning of 2 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-1]
Supplying, fixing, and commissioning 4 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-13]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-8]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq mm copper conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-9]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-32]
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials testing & recording the results as per specification no ESE -LA [9-1-6]
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2]
SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete. [17-1-21]
SITC of Electric Traction Passenger Lift with · Rated capacity :- 8 Passenger/544 Kg · Floors :- G+2 floor (3 Stops/3 Landings) · Travel :- 3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0 mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of 1300 .mm wide x 1300 .mm deep x 1100 mm high · Lift shaft available having clear size of 1100 mm wide x 1300 mm deep, 1500 mm Pit depth, 4200 mm Overhead. Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.
Providing Fire Fighting System For The Proposed ( P + 2 FLOORS) Central Admin Building At- New Mahsul Bhavan Building Shirdi,Tal-Rahta,Dist-Ahmednagar. ( Part-A - Sub Work No. 05 ) Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. [3-11-77]
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-15]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-24]
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. [7-11-8]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Supplying, installing, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1600 to 1800 LPM at 70 to 55 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 30kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-F insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/EP [13-1-2]
Supplying, installing, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type multi stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-F insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete as per specification no. FF-MFP/JP [13-2-2]
Supplying, installing, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 1600 to 1800 LPM at 70 to 50 m head driven by 45 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Water cooled with radiator diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v 50Hz AC supply diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding residential silencer instruments and protection as per standard specification stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/DP [13-4-1]
Supplying, installing, testing and commissioning of fire pump control panel (FCP) of cubical construction floor mounted type fabricated from minimum 2 mm thick CRCA sheet compartmentalised with hinged lockable doors with enclosure protection class IP54 duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) cable alley interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories mountings and internal wiring with adequate size copper conductor cable earth terminals numbering etc. complete in all respect suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories wiring & cabling along with allied accessories with following incoming and outgoings suitable for automatic & manual operation on 415V 3 phase 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby alternate run per start in auto mode) comprises of the following features & switchgears 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-5]
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-6]
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-7]
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. [13-6-10]
Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern PN16 pressure rating screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS [13-7-8]
Supplying and erecting 100 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating as per specification no. FF-VL/SV [13-7-14]
Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating as per specification no. FF-VL/SV [13-7-15]
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-19]
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-20]
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-21]
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-24]
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-25]
Supplying gun metal double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV [13-7-36]
Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT [13-8-1]
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV [13-8-2]
Supplying and erecting 63mm dia reinforced rubber lined (R.R.L.) hose pipe 15m in length fitted with necessary accessories complete as per specification no. FF-FFA/RRL [13-8-4]
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ [13-8-8]
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC [13-8-10]
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia for supplying water in fire tank complete as per specification no. FF-FA/FMC [13-8-11]
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT [13-8-12]
Supplying and erecting 20/25mm dia gun metal air release cock with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV [13-8-13]
Supplying and erecting 100 mm dia. pressure gauge 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve erected with provided G.I. pipe elbow etc. complete as per specification no. FF-FFA/PG [13-8-14]
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve G.I. nipple elbow etc complete as per specification no. FF-FFA/PS [13-8-15]
Supplying and erecting brass orifice plate having 6 mm. thickness 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP [13-8-16]
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8 x 6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-19]
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve hose pipe hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8 x6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-20]
Supplying, installing, testing and commissioning of FR XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-10]
Supplying, installing, testing and commissioning of optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD [13-9-3]
Supplying, installing, testing and commissioning of multi sensor heat detector with smoke and heat combination (RoR + fix temperature) with base on back box necessary connections complete as per specification no. FF-FAS/HD [13-9-2]
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop with on-board LCD display with min 16 lines of text operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition suitable provision for network connectivity interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908 2021 IS 2189 2008 EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. [13-10-2]
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type) made of addressable break glass plastic square in shape surface/flush mounted with Break Glass massage embedded on the glass complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. [13-10-9]
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 reed relays EN 54 or UL Listed FF-AFAS/CRM [13-10-10]
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 Reed relays FF-AFAS/MM [13-10-11]
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 Reed relays FF-AFAS/ISM [13-10-12]
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908 2021 with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54 conforming to IS 2189 2008 IS 15908 2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. [13-10-13]
Supplying, erecting, testing and commissioning of 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR [13-11-1]
Supplying, erecting, testing and commissioning of 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC [13-11-2]
Supplying, erecting, testing and commissioning of stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector stereo jack complete as per specification no. FF-PA/MIC [13-11-3]
Supplying, erecting, testing and commissioning of rust free microphone floor stand of chrome plating/powder coating or S.S. material 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete. [13-11-4]
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC [13-11-6]
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete. [13-11-10]
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. [16-1-5]
Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. [13-15-1]
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site as required complete. [16-1-6]
Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). [16-3-5]
Supplying and erecting ABC powder type fire extinguisher as per IS 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. [999-1-341]
Supplying and installing auto glow (Viewing up to 15 mtr length) fire signages in PVC/Vinyl 4/6mm thick sheet or as per sample approved by client viz fire hydrant fire hydrant fire extinguishers fire exists fire door fire hose box fire & Electrical & safety etc size 300mm* 100 mm [999-1-380]
Supplying and installing auto glow (Viewing up to 15 mtr length) fire signages viz fire hydrant fire hydrant fire extinguishers fire exists fire door fire hose box fire & Electrical & safety etc size 450mm* 150 mm [999-1-343]
Rossette Plate powder coated in white/off white colour with 25 mm dia. Hole. [999-1-346]
Providing Air Conditioning For The Proposed ( P + 2 FLOORS) Central Admin Building At- New Mahsul Bhavan Building Shirdi,Tal-Rahta,Dist-Ahmednagar ( Part A - Sub Work No. 06 ) Supplying, installing, testing and commissioning of split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC [3-2-13]
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. [3-2-26]
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete. [3-2-27]
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system. [4-2-9]
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system. [4-2-10]
Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Providing Submersible Pump For The Proposed ( P + 2 FLOORS) Central Admin Building At- New Mahsul Bhavan Building Shirdi,Tal-Rahta,Dist-Ahmednagar ( Part A - Sub Work No. 07 ) Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10]
Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12]
Supplying, fixing, and commissioning MCB type change over switch 4 pole 25A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS [5-3-24]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nuts bolts etc. complete. [6-1-12]
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars 500V 100A having 15mm (Width) X 3 mm (Thickness) with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB [6-2-1]
Supplying and erecting 525 V 3 phase 50 Hz. MPP type capacitor having minimum overcurrent capacity of 1.8 In peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of metalised polypropylene condensers (MPP) with the standard capacities of 2 3 5 7 10 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee. [6-5-3]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-31]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP [9-1-3]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 390 LPM discharge at 55 to 11 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP [12-2-1]
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50 c/s. A.C. supply having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP [12-3-2]
Supplying and erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. [12-4-9]
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14]
Supplying and erecting Water level controller 230/415 V A.C. Four way under ground & Over head tank operation only. [12-4-15]
Supplying and erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos) [12-4-16]
Supplying and erecting automatic control panel for 3 Phase 415 volt A.C Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc . [12-4-17]
Supplying, installing, testing and commissioning of FR XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-11]
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. [16-5-6]
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete. [16-5-18]
Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. [16-6-15]
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. [16-6-21]
Providing Street light For The Proposed ( P + 2 FLOORS) Central Admin Building At- New Mahsul Bhavan Building Shirdi,Tal-Rahta,Dist-Ahmednagar ( Part A - Sub Work No. 08 ) Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14]
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 4400 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. [2-4-4]
Supplying, erecting and marking SPMCB 0.5A to 5A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-1]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-27]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-9]
Providing and erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL [8-2-12]
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-21]
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-22]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). [16-3-9]
PART-B ( EVM Godown & Training Hall Bldg.) Providing Internal Elecrification For The Proposed EVM Godown & Training Hall Building At- New Mahsul Bhavan Building Shirdi,Tal-Rahta,Dist-Ahmednagar. ( Part B-Sub Work No. 01 ) Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-10]
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-12]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting mains with 4x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]
Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-29]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2]
Supplying and erecting modular type D.P. switch 32A with indicator duly erected on provided plate and box with wiring connections complete. [1-6-8]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11]
Supplying and erecting modular type bell indicator duly erected on provided plate and box with wiring connections complete. [1-6-18]
Supplying and erecting modular type buzzer 220 / 250V duly erected on provided plate and box with wiring connections complete. [1-6-19]
Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-35]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-36]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-39]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-40]
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-5]
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-6]
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18]
Supplying and erecting inverter LED batten 20W tube light fitting with polycarbonate housing heat sink integrated HF electronic driver Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt CRI>80 CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. [2-1-22]
Supplying and erecting integrated LED Highbay Fitting 70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics having system lumens output of Min.10000 Lumens min. efficacy of 145 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-240V inbuilt surge protection of 4 kV Life class of 50 000 Hrs. at L50B50 including driver complete with 3 Year warranty as per specification No FG-ODF/FLS2. [2-6-1]
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-14]
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. [2-11-5]
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. [2-11-6]
Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC [3-3-10]
Point wiring for independent plug in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E ) FRLSH grade copper wire modular type switch earthing and required accessories as per specification No WG-PW/SW [1-7-14]
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW [1-7-15]
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW [1-7-16]
Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26]
Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 770 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-2]
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2000 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-5]
Supplying and erecting air circulator 600 mm. sweep oscillating type wall mounting 1440 RPM without speed regulator overheat protection unit totally enclosed flame proof motor suitable for 230/250 volts single phase 50 cycles A.C. supply core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. [2-10-6]
Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator metallic blades overhead protection unit totally enclosed flame proof motor with additional 3 core wire 5 meter length and hand shield type 3 pin6A. plug top complete with moisture proof treatment and ‘E’ class insulation. [2-10-9]
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) [3-5-1]
Supplying, installing, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-3]
Supplying and erecting 12V/17Ah -18Ah SMF battery with battery terminal wire duly charged with 12 months warranty complete [3-8-8]
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-1]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-4]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 8 ways /24 poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-5]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying, Erecting and Commissioning of 4 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-5]
Supplying, Erecting and Commissioning of 4 pole RCCB 63A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-6]
Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9]
Supplying, Erecting and Commissioning of 4 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-4]
Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10]
Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11]
Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-13]
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. [7-11-6]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Providing L.V. System For The Proposed EVM Godown & Training Hall Building At- New Mahsul Bhavan Building Shirdi,Tal-Rahta,Dist-Ahmednagar ( Part-B - Sub Work No. 02 ) Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]
Supplying and erecting modular type T.V. socket single outlet duly erected on provided plate and box with wiring connections complete. [1-6-14]
Supplying and erecting modular type telephone socket one gang with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-15]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected. [1-6-26]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-34]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-35]
Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-1]
Supplying and erecting 10 pair 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier polythene sheathed G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW [1-8-13]
Supplying and erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW [1-8-18]
Supplying, Erecting and Commissioning of MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW [1-9-1]
Supplying, Erecting and Commissioning of 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW [1-9-11]
Supplying, Erecting and Commissioning of 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW [1-9-18]
Supplying, Erecting and Commissioning of digital (hybrid) type EPABX of 3 x 8 extensions complete. [1-9-24]
Supplying, Erecting and Commissioning of push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. [1-9-29]
Supplying, Erecting and Commissioning of IP telephone instrument as per specification complete. [1-9-30]
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1]
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC [1-10-16]
Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC [1-10-18]
Supplying, fixing, and configuring 8-ports managed gigabit Layer-2 switch 10/100/1000 base-T POE smart switch plus 2 SFP erected in provided rack complete. [1-11-2]
Supplying, fixing, and configuring broadband ADSL router with all accessories on provided rack as per specification No. WG-NWC/ADSL [1-11-17]
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1]
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO [1-12-2]
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK [1-12-17]
PART-C ( Multipurpose Hall ) Providing Internal EI For The Proposed Multipurpose Hall Building At- New Mahsul Bhavan Building PremisesShirdi,Tal-Rahta,Dist-Ahmednagar.( Part-C- Sub Work No. 01 ) Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-7]
Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-8]
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-10]
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-11]
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-12]
Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit [1-2-1]
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit [1-2-2]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting mains with 4x 10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-5]
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14]
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-15]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-36]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-38]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-40]
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-5]
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW [1-7-6]
Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26]
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2000 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-5]
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2750 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-6]
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty. [2-1-15]
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21]
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-14]
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. [2-11-5]
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. [2-11-6]
Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator metallic blades overhead protection unit totally enclosed flame proof motor with additional 3 core wire 5 meter length and hand shield type 3 pin6A. plug top complete with moisture proof treatment and ‘E’ class insulation. [2-10-9]
Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC [3-3-10]
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) [3-5-1]
Supplying, installing, testing and commissioning of 10kVA capacity online pure sine wave with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf 3 phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-6]
Supplying, installing, testing and commissioning of 20kVA capacity online pure sine wave with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS [3-7-8]
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire duly charged with 24 months warranty complete [3-8-10]
Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire duly charged complete with 24 months warranty complete [3-8-11]
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-13]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-1]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 8 ways /24 poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-5]
triple pole and neutral distribution board (TPNDB) 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) with door 1.2mm thickness surface/flush mounted on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 [5-4-16]
Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1]
Providing and erecting floor/wall mounting MCCB panel board with door suitable for four pole incoming 250A 8 ways Four pole outgoing up to 100 A MCCBs on iron frame as per specification no SW-SWR/MCCBPB. (Excluding MCCBs) [5-7-4]
Providing and erecting 4 Pole MCCB 415V 250A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-3]
Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-29]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-20]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-28]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-23]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-19]
Supplying, erecting & terminating Supplying erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-30]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Supplying Installing Testing & Commissioning of ENTRY/ Exit LED Glowsigh with battery back up color Green battery backup 1 hours [999-1-131]
Supplying Installing Testing & Commissioning Profile SF 17x5 (MTR) supply ied alluminium profile 32mm x8mm [999-1-132]
Supplying Installing Testing & Commissioning of FL STRIP 2835/180 4k 24V IP20 5MM With bridgelux led (MTR) 2835 edison / bridgelux smd led 15watt/per fit colour temp 3k/4k ip20 make fido light. [999-1-133]
Supplying Installing Testing & Commissioning of POWER SUPPLY 4.2A/24V IP20 Meanwell Non Dimm LRS-100-24. [999-1-134]
Supplying Installing Testing & Commissioning of Step Light Profile (Per MTR) supply testing & commissioning of led aluminium profile. [999-1-135]
Supplying Installing Testing & Commissioning of Power Supply 2A/24V NON DIMM SAFFRON [999-1-136]
Supply Installing Testing and Commissioning of LED COB Light deep coned type recessed mounting with system efficacy of 1001m/w having lumens output system lumen out put of at least 4000 lumens or more should be dali dimmeble Philips Or Equvivalent [999-1-137]
Supply Installing Testing and Commissioning of Powre supply for Relay Controller similar to Dynalite DDNP1502 [999-1-138]
Supply Installing Testing and Commissioning of PDTS Network Touch Screen intelligeant control and direct access to schedulling scene editing diagnostics and local environmenatl sensing with 178mm capacitive touch screen with higher resolution rich colour proximity sensor triggers soft halo light input 12 to 24 VDC supply current 500mA 12 VDC (Item code PDTS) with Embeded Software for Controlling All devices with Touch Panel/Touch Screen IPAD with Docking Station. [999-1-139]
Supply Installing Testing and Commissioning of IP 22 Antumbra Display type 6 key User Interface provides a central LCD display to present multiple pages (upto 16) of functions and system information for workstations break out areas training rooms etc with fully programmable option for indivisual control/ group control / Scene control /Tasks etc. Wall mounted on (3.46x3.46 Size) moduler box .Front cover blank with backlight biilt in proximity and Loaded icons like presentation scenario meeting scenario aster On/Off Powersaving mode etc. along with a LED indicator for each operation Custom engraving facility.Operating on 12 V DC 40-50mA from netwoek (Item Code PADPE+DACM-V2) [999-1-141]
Providing Sound System For The Proposed Multipurpose Hall Building At- New Mahsul Bhavan Building PremisesShirdi,Tal-Rahta,Dist-Ahmednagar. ( Part-C-Sub Work No. 02 ) Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-11]
Supplying, erecting, testing and commissioning of rust free microphone floor stand of chrome plating/powder coating or S.S. material 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete. [13-11-4]
Supplying, erecting, testing and commissioning of rust free microphone table stand of chrome plating/powder coating or S.S. material up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete. [13-11-5]
Supplying and fixing 42 U floor mount server rack (Dimension-DxWxH – 800x1000x2070 mm) as per specification No. WG-NAS/RAK [1-12-29]
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC [13-11-6]
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No WG-MA/CON [1-2-8]
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete. [13-11-10]
Supplying Installation Testing & Commissioning of Line Array Loudspeaker Hanging Bracket With Accesaris [999-1-351]
Supplying Installation Testing & Commissioning of Power Amplifier Two-channel 2100W 4? Power Amplifier Peakx Plus™ Limiters provide the ultimate in system performance and protection by allowing full control over threshold attack and release Enhance
Supplying Installation Testing & Commissioning of 18 in. High Power Flying Subwoofer 18 inch 2268H Differential Drive® woofer for extended low-frequency output Large port area for reduced distortion 20 mm threaded pole socket for solid secure satellite speaker mounting Specifications Power Rating 800 W / 1600 W / 3200 W Frequency Range 31 Hz – 220 Hz Dimensions (H x W x D) 508 mm x 597 mm x 749 mm (20.0 in x 23.5 in x 29.5 in) Frequency Response (-10dB) 31 Hz – 220 Hz Recommended Crossover Frequencies 80 Hz 24 dB / octave HPF80 Hz 24 dB / octave LPF System Maximum SPL 130 dB SPL peak System Sensitivity (1w 1m) 95 dB SPL LF Driver 1 x JBL 2268H 457 mm (18 in) Differential Drive woofer Nominal Impedance 8 ohms Active Tunings Tunings available at www.jblpro.com Enclosure Rectangular 18 mm 13-ply birch plywood Suspension / Mounting Optional VRX932LA-AF line array frame kit or 10mm eyebolt Finish Black DuraFlex™ finish Grille Powder coated black 16-gauge perforated steel with acoustical transparent charcoal foam backing. Inputs Neutrik® Speakon® NL-4 (x2) [999-1-353]
Supplying Installation Testing & Commissioning of Stage Moniter Speakar Professional Powered Two-Way 12-inch PA Loudspeaker Features Transducers 912G 12” ferrite magnet woofer JBL 2408H-2 1.5 poly-annular diaphragm compression driver Updated JBL image control waveguides improve dispersion Low-noise low-distortion gain staging design Lightweight efficient Class D amplification Power 2 000 watts peak/1 000 watts RMS Frequency response 50 Hz–20 kHz 4pi (-10 dB) 65 Hz–17 kHz 4pi (-3 dB) Dispersion 90° x 50° Max SPL 132 dB Crossover frequency 2 050 Hz Specifications Frequency Range (-10dB) 50 Hz - 20 kHz (4?) Frequency Range (-3 dB) 65 Hz - 17 kHz (4?) Coverage Pattern 90° x 50° Transducer Impedence Rated Woofer 4 ? Tweeter 8 ? Max SPL 132 dB Power Rating 2000W peak / 1000W RMS [999-1-354]
Supplying Installation Testing & Commissioning of Compact 2-way Loudspeaker with 2 x 8” LF Features 1” Exit Compression Driver with PT™ Waveguide 205 mm (8 in) LF transducer Compact enclosure 750W Program Specifications Frequency Range (-10dB) 53 Hz - 20 kHz Frequency Response (±3 dB) 65 Hz – 20 kHz System Power Rating 700 W (AES rated) 375 W / 750 W / 1500 W (Continuous/Program/Peak) (IEC rated) Impedance 8 ohms Coverage Pattern /26 120° x 60°/95 90° x 50° Dimensions (H x W x D) 679.5 x 237.5 x 254.0 mm (26.8 x 9.4 x 10.0 in) Net Weight (each) 18.6 kg (40.9 lb) Crossover Modes Passive Maximum SPL (1m) 120 dB System Sensitivity (1w 1m) 94 dB SPL [999-1-355]
Supplying Installation Testing & Commissioning of Two-channel 1200W 4? Power Amplifier eakx Plus™ Limiters provide the ultimate in system performance and protection by allowing full control over threshold attack and release Enhanced Subharmonic Synth section provides user control over frequency gain and filter type for system-specific tuning 3 User-defined fan mode controls – normal early and fullspeed – for matching fan performance to a specific application Specifications Channels 2 Sensitivity 1.4V Rated Power Output (per channel) 1600W 2? 1200W 4? 650W 8? Signal to Noise Ratio (below rated 1 kHz power at 8 ohms) 100 dB (A-weighted) THD < 0.5% Frequency Response (at 1W 20 Hz - 20 kHz) + 0 dB -1 dB Crosstalk (below rated power) 20 Hz to 1 kHz >70 dB Dimensions 3.5 x 19 x 12.25 Weight 18.5 lbs (8.4 kg) Shipping Weight 21.5 lbs (9.8 kg) IEC Power Connector 15A [999-1-356]
Supplying Installation Testing & Commissioning of JBL Professional MTU-28 U?Bracket for AC28/xx Two-Way Loudspeaker [999-1-357]
Supplying Installation Testing & Commissioning of Professional Quality Imported Power Amplifier 480 W with Built in Temperature controlled Fan Overload Protection Short circuit Protection Voltage Overload Protection Short circuit Protection. Voltage 24 VDC +15% / -15% Current max 30 A Performance Output power (rms/maximum) 480 W /720 W Power reduction on backup power -1 dB Frequency response 50 Hz to 20 kHz (+1/3dB 10 dB ref. rated output) Distortion <1% rated output power 1 kHz S/N (flat at max volume) >90 dB Make-Bosch/Mipro/Ev [999-1-359]
Supplying Installation Testing & Commissioning of 32-Channel Premium Mixing Console 24 Mic Inputs with 48V Phantom Power and HPF per Channel 32 Line Inputs (24 mono and 4 stereo) 6 AUX Sends + 2 FX Sends 4 GROUP Buses + ST Bus 2 Matrix out 1 Mono out [999-1-360]
Supplying Installation Testing & Commissioning of Vocal Microphone Frequency response tailored for vocals with brightened midrange and bass roll off Uniform cardioid pickup pattern isolates the main sound source and minimizes background noise Pneumatic shock-mount system cuts down handling noise Effective built-in spherical wind and pop filter Supplied with break-resistant stand adapter which rotates 180 degrees Legendary Shure quality ruggedness and reliability Cardioid (unidirectional) dynamic Frequency response 50 to 15 000 Hz [999-1-361]
Supplying Installation Testing & Commissioning of Boundary Microphone SPECIFICATIONS Frequency Response (Figure 1)-50 to 17 000 Hz Output Impedance EIA Rated at 150 ? (180 ? actual) Sensitivity (at 1 kHz open circuit voltage) Cardioid Cartridge –27.5 dBV/Pa (42.2 mV) Supercardioid Cartridge –26.5 dBV/Pa (47.3 mV) Omnidirectional –22.0 dBV/Pa (79.4 mV) 1 Pascal=94 dB SPL Maximum Sound Pressure Level (1 kHz at 1% Total Harmonic Distortion 1 k? load) Cardioid 117.0 dB Supercardioid 116.0 dB Omnidirectional 111.5 dB Signal to Noise Ratio (referenced at 94 dB SPL) Cardioid 71.0 dB Supercardioid 72.0 dB Omnidirectional 76.5 dB Preamplifier Output Clipping Level –6 dBV (0.5 V) [999-1-362]
Supplying Installation Testing & Commissioning of Overhead Microphone SPECIFICATIONS Frequency Response (Figure 1) 50 to 17 000 Hz Polar Pattern (Figure 2) Output Impedance EIA Rated at 150 ? (180 ? actual) Sensitivity (At 1 000 Hz open circuit voltage*) Cardioid –35.0 dBV/Pa (17.8 mV) Supercardioid –33.5 dBV/Pa (21.1 mV) Omnidirectional –27.5 dBV/Pa (42.2 mV) *1 Pascal = 94 dB SPL Maximum SPL (1 kHz at 1% THD 1 k? load) Cardioid 124.2 Supercardioid 122.7 dB Omnidirectional 116.7 dB [999-1-363]
Supplying Installation Testing & Commissioning of Podium Microphone FEATURES Available with a variety of heights and mounting styles to choose from. The S/C S/S and S/N models include a silent mute switch with LED indicator a Shure Microflex exclusive. Wide dynamic range and frequency response for accurate sound reproduction across the audio spectrum Interchangeable cartridges provide the right polar pattern for every application SPECIFICATIONS Equivalent Output Noise (A-weighted) Cardioid 28.0 dB SPL Supercardioid 26.5 dB SPL Omnidirectional 20.5 dB SPL Signal to Noise Ratio (referenced at 94 dB SPL) Cardioid 66.0 dB Supercardioid 67.5 dB Omnidirectional 73.5 dB Dynamic Range at 1 kilohm load 96.2 dB 100 dB at 0 gain Common Mode Rejection 45.0 dB minimum Preamplifier Output Clipping Level (1% THD) -6.0 dBV (0.5 V) -12 dBV at 0 gain Polarity Positive sound pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of output connector Power Requirements 11 to 52 Vdc phantom 2.0 mA Environmental Requirements Operating Temperature Range -18 to 57 degrees C (0 to 135 degrees F) Relative Humidity 0 to 95%. [999-1-364]
Supplying Installation Testing & Commissioning of DriveRack Features INPUT PROCESSING dbx Compression AFS™ (Advanced Feedback Suppression) 31-Band Graphic EQ 12-Band Parametric EQ (with narrow notch capabilities) Subharmonic Synthesis Backline Delay Noise Gate OUTPUT PROCESSING Crossover (supports full range up to mono 6-way systems) 12-Band AutoEQs (8 AutoEQ bands 4 User bands) dbx Compression Automatic Gain Control Subharmonic Synthesis Noise Gate Tower Delays (up to 1000ms per output) 8-Band Parametric EQs (used for speaker tunings) dbx Limiting Driver Alignment Delays [999-1-366]
Supplying Installation Testing & Commissioning of Speaker Cable For Twisted Cable Size 2.5 Sqmm Usage/Application - Twisted Cable Size - 2.5 Sqmm Type Of Cable - Speaker Cable Electronic 2 C #14 Str TC PVC Ins PVC Jkt CL3.Electronic 2 Conductor 14AWG (42x30) Tinned Copper PVC Insulation PVC Outer Jacket CL3 [999-1-367]
Supplying Installation Testing & Commissioning of Speaker Cable For Twisted Cable Size 6 Sqmm Audio Cable 2 Conductor 10 AWG BC Unshielded CL2 Audio Cable Rated-CL2 2-10 AWG highly flexible stranded bare copper conductors with PVC insulation PVC jacket with ripcord [999-1-368]
Supplying Installation Testing & Commissioning of 3 pole female/Male cable connector with Nickel housing and silver contacts. Technical Information Product -Title NC3FXX Connection Type XLR Gender female Electrical Capacitance between contacts ? 4 pF Contact resistance ? 3 m? Dielectric strength 1 5 kVdc Insulation resistance > 10 G? (initial) Rated current per contact 16 A Rated voltage < 50 V Make-Newtrick/MX [999-1-369]
Supplying Installation Testing & Commissioning of 4 way Satge Box With XLR Chassis Connectors Make-MX/Casting/Newtric [999-1-370]
Supplying Installation Testing & Commissioning of 32 way Patch Panel Box With XLR Chassis Connectors Make-MX/Casting/Newtric[Non CSR]
Supplying Installation Testing & Commissioning of 4 pole cable connector chuck type strain relief dark grey bushing Features & Benefits Current rating 40 A rms continuousUp to 50 A audio signal duty cycle 50%Only 3 parts easy to assembleHigh impact materials - long-lasting and reliableEasy and extremely precise locking system Quick Lock Improved grip on latch1 piece strain relief chuck for 7 to 14.5 mm cable O.D.Color coding possibleImproved screw-type termination for highest pull-out forceIntegrated design guarantees [999-1-372]
Providing Stage light System For The Proposed Multipurpose Hall Building At- New Mahsul Bhavan Building PremisesShirdi,Tal-Rahta,Dist-Ahmednagar ( Part-C-Sub Work No. 03 ) Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-31]
Supplying and erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. [12-4-8]
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC [13-11-6]
SITC of 100W High Quality LED Parcan Light complete with Lamp source 3200K CCT Colour temperature CRI & TLCI Values above 95 COB LED source from Citizen/ Philips/ Osram/ Cree or reputed make (LM80 to be provided) DmX 512 dimming with 3 channel control Beam Angle of 11° / 25° / 35° Total Power Consumption of 120W High quality output replacing 1000W Halogen Par Flicker Free 100% for Tv & Film Cameras 11.7KHz Refresh Rate Linear Dimming 0 100% Fuse and Internal safety protections Strobe option Adjustable 125 times/Sec Variable Fixture provided with Yoke of Manual Adjustment 5 Pin XLR for DmX Black powder coated body. RDM Control options with latest technology (RDM ID to be specified) Certification having BIS compliant to IS 10322 (Part 5/ Sec 1) 2012 CE Certification compliant to EN60598-1 2015 EN61437-2-13 2014 LM79 Certificates from NABL Accredited laboratory. Brand embossed impact on the light body for genuine product [999-1-413]
SITC of 200W LED Profile Spot 19 Degree Light complete with 3200K CCT Colour Temperature COB LED source from Citizen/ Philips/ Osram/ Cree or reputed make (LM80 to be provided) CRI & TLCI above 95 Strobe option Adjustable 1 25 times / Sec 4 Kinds of dimming curves Black finish housing Manual Focus with 4 Beam shaping cutters Efficient and well-designed Lamp reflector Efficient Copper tube based Heat Sink for Heat Dissipation Sleek and Unique Designed Light weight body Fixture provided with Yoke of Manual Adjustment DmX 512 dimming with 1 or 3 Channel modes IP20 protection having Lux 3 Mtr above 12040 suitable to illuminate the key presenter or talent on stage. RDM Control options with latest technology (RDM ID to be specified) Certification having BIS compliant to IS 10322 (Part 5/ Sec 1) 2012 . CE Certification compliant to EN60598-1 2015 EN61437-2-13 2014 LM79 Certificates from NABL Accredited laboratory. Brand embossed impact on the light body for genuine product [999-1-414]
SITC of 54 x 3W LED Par Light RGBW Beam Angle 25° complete with LED source from Lumi led / Seoul / Nichia or reputed make (LM80 to be provided) RGBW 3W Lamp source x 54 Pcs DmX 512 dimming with 8 Channel High Bright Red Green Blue White LED’s Source Unlimited Colour Mixing through DmX 0 100% Linear dimming In built presets for different colours Strobe Mode 20 times/Sec Data DmX through 3 / 5 Pin XLR’s 65dB 130dB Sound sensing capacity Power In and Out Connections High precision colours IP20 protection Powder coated Black finish housing Having Sound Control & Master Slave Auto Run Mode Illuminate the Indoor stage with unlimited colour effects Rigidly built pressure die-casted Aluminium body. RDM Control options with latest technology (RDM ID to be specified) Certification having BIS compliant to IS 10322 (Part 5/ Sec 1) 2012 CE Certification compliant to EN60598-1 2015 EN61437-2-13 2014 LM79 Certificates from NABL Accredited laboratory. Brand embossed impact on the light body for genuine product [999-1-415]
SITC of 54x3W LED 3200K Par Light Beam Angle 25° complete with 3200K 3W Lamp source x 54 Pcs LED source from Lumi led / Seoul / Nichia or reputed make (LM80 to be provided) Having CRI TLCI Values above 95 Flicker Free for high FPS Smooth fade in and Fade out High precision steady colour No heat DmX 512 dimming with 2 Channel 0 100% Powder coated Black finish housing Rigidly built pressure die-casted Aluminium body LED Easy view display Data DmX through 3 / 5 Pin XLR’s 65dB 130dB Sound sensing capacity Power In and Out Connections Total Power Consumption of 180W Sound Active Mode Control IP20 protection. RDM Control options with latest technology (RDM ID to be specified) Certification having BIS compliant to IS 10322 (Part 5/ Sec 1) 2012 CE Certification compliant to EN60598-1 2015 EN61437-2-13 2014 LM79 Certificates from NABL Accredited laboratory. Brand embossed impact on the light body for genuine product [999-1-416]
SITC of 400W LED Blinder Light 30 Degree complete with 3200K CCT 4x100W Chip On Board LED Lamp source COB LED source from Citizen/ Philips/ Osram/ Cree or reputed make (LM80 to be provided) DmX 512 dimming with 4 /8 Channel modes CRI & TLCI Value > 90 Strobe option Adjustable 1 25 times / Sec Variable Beam Angle 30 Degree Total Power Consumption of 420W 11.7KHz Refresh Rate In built preset’s for effects Fuse and Internal safety protections Active Cooling with Low Noise Fan 5 Pin XLR for DmX High quality well designed inbuilt reflector Flicker Free 100% for Tv & Film Cameras Black finish housing IP20 protection Having Strobe option and smooth dimming illuminate Stage with uniform light intensity levels. RDM Control options with latest technology (RDM ID to be specified) Certification having BIS compliant to IS 10322 (Part 5/ Sec 1) 2012 CE Certification compliant to EN60598-1 2015 EN61437-2-13 2014 LM79 Certificates from NABL Accredited laboratory. [999-1-417]
SITC of 200W LED Fresnel Light having COB LED source from Citizen/ Philips/ Osram/ Cree or reputed make (LM80 to be provided) 3200K colour temperature High quality uniquely designed Fresnel Lens CRI TLCI and R9 value above 96 LED COB Based Source No Multiple Shadows – Single Source illumination Total Power Consumption of 220W Linear dimming 0 100% Adjustment Flicker Free for High FPS Power AC90-260V 50/60HZ Working Temperature - +40° -30° Active Cooling with Low Noise Fan DmX & RDM Control options with latest technology Fixture provided with Yoke of Manual Adjustment Manual and DMX control Option mode through 5pin xlr Black powder coated fabricated housing with normal yoke. RDM Control options with latest technology (RDM ID to be specified) Certification having BIS compliant to IS 10322 (Part 5/ Sec 1) 2012 CE Certification compliant to EN60598-1 2015 EN61437-2-13 2014 LM79 Certificates from NABL Accredited laboratory. Brand embossed impact on the light body for genuine product [999-1-418]
SITC of Light fixture mouting clamp Customized for suspending on fixed bars on stage Made up of Aluminium Die casted MS threaded T bolt with yellow passivation finish Complete with black powder coating matt black finish. Safe working load 150 KG Suitable to Batten of size 30 OD to 60 OD [999-1-419]
SITC of Light Fixture dual safety Chain made up of GI wire rope Bundled and twisted together Having load bearing capacity above 200 Kgs Sleeve on the rope. Carabiner Clip [999-1-420]
SITC of Suspender cum clamps designed made out of MS material 150mm x 150mm x 5mm MS Base plate Threaded rod Black powder coated finish All the materials under gone through 7 tank process with various chemical treatment to keep them rust free Suitable to hold various type grid & other rigging systems. [999-1-421]
SITC of Fixed stage side Ladder as per the design With an Mild Steel 40NB 48 OD black matt finish. It should hang from the roof with MS angle which is suspended from the fish plate of 5mm. Size of 600mm x 2400mm Manual movable Made out of 40NB 48 OD Mild steel pipe dual barrel Dual Barrel Arrangement Powder coated with Matt black Texture Single Construction with Cross connecting pipes Cross connecting Pipes at every 600mm Ladder can be moved along the track or adjusted as required Spud & Trolley Pivoted or Fixed Suspenders as per site conditions Round pipe welded to create square frame Heavy duty trolly to hold and rotate wing frame Material for the light bar shall be of Mild Steel Pipe. Powder coated with Matt black Texture Fixing Through Suspenders as per site conditions Ladder Length shall be of customized type as per site condition. [999-1-422]
SITC of Motorised integrated fly bar/winch of 15 Mtr length Motorised Light bar the winch shall be provided with 01 Nos. of 2 HP 3 Phes Foot Mounted Rating 0.12 TO 22KW Frame Size 63 TO 180L RPM 3000 1500 1000 750 Construction (B3) FOOT (B5) FLANGE (B14) FACE and Combination Voltage / Frequency 415V ±10% / 50 ±5% to fix the gear box which contains one shaft. This mechanism shall have drum plate of Cente Distance - 3 to 8 Ratio - 5 1 to 70 1 thickness Puly Set with 6 groves where the GI wire rope of 6mm can be winded up when the hoist moves up and down. 415V AC Motor with Brake for Motor System to lift a load of 180Kg as a safe working load which should be synchronized with Control Panel. functionality Dual barrel Made using 40NB dual construction. black texture finish paint to keep them rust free designed compact gear box 3phase AC motor with Provided with Necessary pulley guide pulleys GI wire rope with winding drum. Compact gearbox along with suitable capacity of motor unit. Upper and lower limit controller Safe working load of 200Kg. Cable management system. [999-1-423]
SITC of Motorised integrated FOH fly bar/winch of 15 Mtr length Motorised Light bar the winch shall be provided with 01 Nos. of 2 HP 3 Phes Foot Mounted Rating 0.12 TO 22KW Frame Size 63 TO 180L RPM 3000 1500 1000 750 Construction (B3) FOOT (B5) FLANGE (B14) FACE and Combination Voltage / Frequency 415V ±10% / 50 ±5% to fix the gear box which contains one shaft. This mechanism shall have drum plate of Cente Distance - 3 to 8 Ratio - 5 1 to 70 1 thickness Puly Set with 6 groves where the GI wire rope of 6mm can be winded up when the hoist moves up and down. 415V AC Motor with Brake for Motor System to lift a load of 180Kg as a safe working load which should be synchronized with Control Panel. functionality Dual barrel Made using 40NB dual construction. black texture finish paint to keep them rust free designed compact gear box 3phase AC motor with Provided with Necessary pulley guide pulleys GI wire rope with winding drum. Compact gearbox along with suitable capacity of motor unit. Upper and lower limit controller Safe working load of 200Kg. Cable management system. [999-1-424]
SITC of Power Distribution Electrical panel having a Incomer of 100 A. Floor mount / rack mount / wall mount. Miniature circuit brakers of single poles shall be fixed of different ratings from 6/10/16/25A as per the lighting fixtures. Wiring inside the module for power control protection and instrument etc. shall be done with use of 1100 V confirming to IS 694 and IS 8130ement.All welding slag grounded off and welding pits wiped smooth with plumber metal. Power panels shall be designed in such a way that the internal space is sufficient for hot air movement and the electrical component does not attain temperature more than 40 degree Celsius. Fabricated panel shall be supported with ms angles of size 25mm x 25mm with an 1.8mm thickness sheet to hold the structure. Neutral separation made using incomer of L&T or Schneider make Voltmeter Ammeter display for reading visualization Individual MCB control for 40 outgoing circuits RYB Phase indicators internally wired using IS certified wires and cables Terminal for both incoming and outgoing cable shall be suitable for 1100 volts grade aluminium/copper conductor PVC insulated and sheathed armoured cable and shall be suitable for connections. Provided with ivory connectors for the internal terminations and external outgoing connecting points Custom built as per specification and project required [999-1-425]
SITC of High quality power junction box 2 way made up of MS Sheet metal fabricated housing. Snap fit fixing /15 (2.5mm ) Total Max Rating 6/16A 250V A.C 20°C to +70°C Black powder coated fibre glands of suitable size fitted with 6/16A. Clamp arrangement for fixing or Raul plug arrangement for wall / floor fixing
SITC of High quality Dimming Out junction box 1 way made up of MS Sheet metal fabricated housing High temperature resistant insulator material All metal housing offers best overall RF protection & electromagnetic shielding Black powder coated fibre glands of suitable size fitted with 3 Pin DmX XLR Female socket Clamp arrangement for fixing or Raul plug arrangement for wall /floor fixing
SITC of DmX Loop Junction Box having 1 No. of DmX 5 Pin XLR Female Socket & 1 No. DmX XLR Male Socket fitted on to a sheet metal fabricated compact Junction box powder coated with matt black texture finish paint. High temperature resistant insulator material All metal housing offers best overall RF protection & electromagnetic shielding. Clamp arrangement for fixing or Raul plug arrangement for wall /floor fixing [999-1-428]
SITC of Black Powder coated cable trays made out of MS Sheet fabricated for a size of 40 x 150 x 40mm & 1.6 mm thickness undergone through 7 tank process with various chemical treatment to keep them rust free with perforation for heat dissipation provided with lid.
SITC of Black Powder coated cable trays made out of MS Sheet fabricated for a size of 40 x 75 x 40mm & 1.6 mm thickness undergone through 7 tank process with various chemical treatment to keep them rust free with perforation for heat dissipation provided with lid.
SITC of DmX Male Female Connectors 3 Pin having rubber sheeth protection for Cross connecting DmX wiring connections
SITC of DmX Male Termination Connector 3 Pin soldered with required capacity of resistor for signal deframing
SITC of DMX 512 Stage Lighting Controller With Midi Socket can make the library on the console 1024 DMX512 channels 96 Mating fixtures Support for fixtures re-connected with the address code Each scanner max available control channels 40 main channel + 40 trim R20 pearl light library support 60 scenes can be saved 10 scenes can be run simultaneously 600 steps in a multi-step scenario Fade in Fade out LTP sliding control 5 graphics can be stored for each scene 10 graphics can be run at the same time Supports fader scenes dimming interlock scene and point control scenarios Graphics generator dimmer P/T RGB CMY Color Gobo lris Focus Graphics Master fader Global repeat lighting Supports now black dial and fader to adjust channel values and fader dimmer Supports FAT32 format U disk read [999-1-433]
SITC of 30-way Power Marshalling Box made up of MS Sheet metal fabricated housing black powder coated and ivory connectors for the internal terminations and external outgoing connecting points fibre / brass glands of suitable size. [999-1-435]
SITC of Flat Cable Wire harness required to provide the input power to the sockets on the hoists connecting between grid level circuit box to on hoist circuit box with below specifications FRLS Multi core Copper cable 18 Cores of Power each with 2.5 Sq. mm copper wires insulated with high insulated material 2 DmX 5 core cables with low noise Width of the flat cable 120mm approx. Clips at each bending of the cable to act as retractor unit Long life no breakage smooth folding [999-1-436]
SITC of FRLS Copper unarmoured Flexible cable IS694 having 7 Core each of 1.5 Sq mm size. [999-1-438]
Supplying installing testing and commissioning FR XLPE armoured cable 12 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [999-1-439]
Providing Stage Craft System For The Proposed Multipurpose Hall Building At- New Mahsul Bhavan Building PremisesShirdi,Tal-Rahta,Dist-Ahmednagar. ( Part-C-Sub Work No. 04 ) SITC of Suspender cum clamps designed made out of MS material 150mm x 150mm x 5mm MS Base plate Threaded rod Black powder coated finish All the materials under gone through 7 tank process with various chemical treatment to keep them rust free Suitable to hold various type grid & other rigging systems. [999-1-440]
SITC of Cable Connecting Circuit Boxes for the termination of cables from Electrical panel to the grid level point made out of MS Sheet metal fabricated housing duly powder coated with matt black texture finish paint fitted with required channels and ivory connectors necessary glands etc. [999-1-442]
SITC of High quality Velvet fabric fire retardant treated as per approved colour and make with a gathering of 50% stitched as per site condition curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies (For Main Curtain) Size 26 Mtr x 6 Mtr. [999-1-443]
SITC of Glazzed Cotton fabric fire retardant treated as per approved colour and make with a gathering of 50% stitched as per site condition curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies (For Midel/Back Curtain) Size 26 Mtr x 6 Mtr. [999-1-444]
SITC of High quality Velvet fabric fire retardant treated as per approved colour and make with a gathering of 100% stitched as per site condition curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies (For Main Valance) Size 25 Mtr x 1.5 Mtr. [999-1-445]
SITC of Glazzed Cotton fabric fire retardant treated as per approved colour and make with a gathering of 50% stitched as per site condition curtain provided with eyelets at every 200/250mm for uniform fixing on to curtain trollies (For Frills) Size 16Mtr x 1.2Mtr. [999-1-446]
SITC of Glazzed Cotton fabric fire retardant treated as per approved colour and make with a gathering of 0% stitched as per site condition curtain provided with eyelets at every 200/250mm for uniform fixing. (For Wing) 6 Mtr x 1.5 Mtr [999-1-447]
SITC of On Stage Fixed Valance Bar 25 Mtrs Length Straight as per the design made out of 40NB 48 OD Mild steel pipe dual barrel supported to hang the Main Valance of the stage system duly powder coated with matt black texture finish paint. All the materials under gone through 7 tank process with various chemical treatment to keep them rust free [999-1-448]
SITC of On Stage Fixed Frill Bar 16Mtrs Length Straight as per the design made out of 40NB 48 OD Mild steel pipe dual barrel supported to hang the frill connected with MS Flat duly powder coated with matt black texture finish paint. All the materials under gone through 7 tank process with various chemical treatment to keep them rust free [999-1-449]
SITC of Fixed Wing Structure designed as per site condition for a height approx 6 Mtr x 1.5 Mtr made up of MS Square tube of 25mm or higher size rested on pivotable trolley on a track for the rotation of the wing. Adjustable floor locking screw jacks with rubber grips. Inverted 4-Wheeler Trolley with Flexi Adaptor Clamp and 360° Rotatable. [999-1-450]
SITC of Motorized Rear Curtain / Back Curten 26 Mtrs straight Centre parting as per design. This mechanism shall be provided with 01 Nos. of 1.5 HP 1440 RPM 90 B5 frame 3Ph.Foot Mounted Rating 0.12 TO 22KW Frame Size 63 TO 180L RPM 3000 1500 1000 750 Construction (B3) FOOT (B5) FLANGE (B14) FACE and Combination Voltage / Frequency 415V ±10% / 50 ±5% to fix the gear box which contains one shaft. This mechanism shall have drum plate of Cente Distance - 3 to 8 Ratio - 5 1 to 70 1 thickness Puly Set with 6 groves where the GI wire rope of 6mm can be winded up when the hoist moves up and down. 415V AC Motor with Brake for Motor System to lift a load of 180Kg as a safe working load which should be synchronized with Control Panel. functionality Dual barrel Made using 40NB dual construction. black texture finish paint to keep them rust free designed compact gear box 3phase AC motor with Provided with Necessary pulley guide pulleys GI wire rope with winding drum. Compact gearbox along with suitable capacity of motor unit. Upper and lower limit controller Safe working load of 200Kg. Cable management system. [999-1-451]
SITC of Motorized DMX operated Main Curtain With Aluminium C Track Runner & Fabricasion Curten 26 Mtrs straight Centre parting as per design. This mechanism shall be provided with 01 Nos. of 1.5 HP 1440 RPM 90 B5 frame 3Ph. 415VAC Motor with Brake for Motor System to lift a load which should be synchronized with Motor Control centre Panel. Winch shall have 3 phase motor with an RPM of 1440 KW (HP) 1.1(1.5) Frame 90S EFF 75.0% MTG B5 AMP 2.7Y Volt 415v DE BRG 62052Z DUTY S1 FREQ 50Hz NDE BRG 62052Z IP 55 AMB 50 degree. The outer surface temperature is limited shall have an Worm Reduction Gearbox with GMRV-90 80 1 90B5 Single Reduction 7.5 1 to 100 1 and the size shall be 90. It shall have an drive unit base frame to fix the gear box which contains one shaft Made up of I Track for complete length Curtain holding trollies with ball bearing for smoother noiseless movement consisting of 4 wheeler master trolley and 2 wheeler trolley placed uniformly at specific interval of200mm /250 mm throughout the track Overlap of 0.50.9 Mtrs. Motor Cable termination box Trollies uniformly distributed along the track at every 200/250mm with a master trolley. Open and close limit controller. Drive unit with suitable capacity of motor unit Wire Rope shall be of GI Wire ropes Min 3mm Dai Undergone through various chemical treatment to keep them rust free Black texture finish paint. All metal parts are powder coated [999-1-452]
Providing Transformer & De Set For The Proposed Multipurpose Hall Building At- New Mahsul Bhavan Building Premises Shirdi,Tal-Rahata,Dist-Ahmednagar ( Part-C-Sub Work No. 05 ) Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]
Supplying and erecting HT CT multifunction DLMS compliance of accuracy of class 0.5 3x63.5V 50 Hz with optical & RS 232 port backlit LCD measures kWh kVAh V I kW 6 months history of energy load survey & displays trivector energy load survey TOD tamper detection & logging power ON /OFF events instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box. [6-3-6]
Supplying, erecting, testing and commissioning of 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle painted with powder coating / epoxy paint of required shade copper bus bar size 25 x 6 mm heavy duty mechanical lock with counter meter for measuring no of times the opening of meter door top side cover (CT PT cover) interlock with meter door epoxy casted 3 nos. CT having required ratio between 10/5A to 50/5A VA10 or 15 Class 0.5S epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50 Class 0.5 suitable for provided trivector meter and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation. [6-4-1]
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-24]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-19]
Supplying, erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 11 kV(E) 3 x 185 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT [7-3-5]
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT [7-5-2]
Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT [7-5-6]
G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-4]
Supplying and laying (including excavation) half round reinforced cement concrete pipe of IS 458 2003 NP-2 class of 150 mm internal diameter in proper line level and slope including providing and fixing collars in cement mortar 1 2 and curing etc. complete. [7-6-6]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-9]
Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ [8-1-13]
Supplying and erecting MS pole bracket for guarding/LT OH line fabricated from ISM channel 75x40x6mm and 550mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT [8-3-3]
Supplying and erecting 100 x 50 x 6 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm of suitable length for 2.4 m wide DP structure and erecting on DP with 50x6mm clamp complete as per specification no. OH-PL/BKT [8-3-11]
Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm and fixed on pole with MS clamp of 80x10 mm nut bolts washers complete as per specification no. OH-PL/VCA [8-3-12]
Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA [8-3-14]
Supplying and erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps nut bolts etc. complete as per drawing. [8-3-17]
Supplying and erecting ACSR conductor of size 6/1-2.59 mm complete. (Weasel) (127.7 kg/km) as per specification No. OH-CON/ACSR [8-4-7]
Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line complete as per specification no. OH-INS/DI [8-5-6]
Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line complete as per specification no. OH-INS/PN [8-5-9]
Supplying and erecting distribution class 11 kV thyrite type lightening arrester with nut bolts on provided MS channel as per specification no. OH-INS/LA [8-5-15]
Supplying and erecting G.I. stay set for poles including loop insulators at inaccessible height with anchor plate 300x300x6 mm. straining screws G.l. stay wire 7/8 SWG G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. [8-6-2]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-2]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4]
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. [9-2-5]
Supplying, installing, testing and commissioning of 3 phase 11/0.433 kV 50 Hz. 500 kVA Mineral oil immersed and naturally cooled outdoor type Copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side temperature rise should not exceed 45? by thermometer in oil and 50? by the resistance method in winding at full load rating using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5% having 7 number of tap positions with standard accessories complete with test certificate with losses below 1510 Watts at 50% load 4300 Watts at 100% load as per IS 1180 (part 1) 2014 with necessary permissions of Electrical Inspector as per specification no SS- TR-NSL. [10-1-9]
Supplying and erecting 11 kV outdoor type gang operated air break triple pole switch 200 A capacity with 3 post pin type insulator per phase mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of C class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. [10-6-1]
Supplying and erecting 11 kV outdoor type drop out fuse with insulator complete with fuse holders fuse barrel with metal fitting fuse element mounted on M.S. channel with working current of 15A capacity complete erected on provided cross arm. [10-6-5]
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG [10-6-18]
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class GI pipe with angle iron supports chain link wire mesh (jali) complete supported on channel iron erected in foundation and painted complete as per specification no SS-AS/DLD [10-6-20]
Providing printed instruction chart for treating persons suffering from electric shock printed in English & Marathi and duly laminated complete. [10-6-22]
Supplying standard first aid box with necessary antiseptic cream medicine for use on wounds due burn crepe bandage gauge bandage medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use scissors anti-septic solution etc. (All above contents shall be of standard makes) [10-6-24]
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS 15652 – 2006 having 2 mm thickness up to 3.3 kV [10-6-25]
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 125 kVA output continuous rating 3 Phase 415 V 50c/s 0.8 p. f. A.C supply a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours along with standard accessories self-excited self-regulated screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 % with performance class G2 and maximum fuel consumption 21.4 Ltr/hr 75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters switchgears indicators connected with suitable wires/cables the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet sound absorbing material to restrict sound level up to 75 dB at 1.0 m provided with first filling of oil diesel not less than 230 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG [11-1-13]
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 100 kVA up to 125 kVA capacity Three phase 415 Volts 50Hz A.C. with all standard features safeties etc as per specification no. GEN-AMF. [11-2-11]
Supplying, installing, testing and commissioning of FR XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-11]
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. [16-1-5]
second class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1 6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually striking joints on unexposed faces raking out joints on exposed faces and watering etc. Complete. [16-2-1]
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete. [16-2-3]
Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram). [16-2-4]
Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. [16-3-1]
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1 3 6 cement concrete 20 x 25 mm stone metal (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered with necessary curing and finishing complete. (above 6 m to 9 m poles) [16-3-3]
Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1 3 6 cement concrete 20 x 25 mm stone metal 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered with necessary curing and finishing complete. (for above 9 m poles) [16-3-4]
Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). [16-3-5]
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1 3 6 cement concrete (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). [16-3-6]
Providing fire fighting hydrant and sprinkler system and smoke detection system for multipurpose hall/Evm Godown at shirdi Tal. Rahata dist. Ahmednagar ( Part C- Sub Work No. 06 ) Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No WG-MA/CON. [1-2-7]
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. [1-6-28]
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-18]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-20]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-32]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 146 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-13]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Providing Round bottom fire bucket of 9 Litres capacity as per IS 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark on provided stand/ wall hook complete. (NON CSR) [999-1-355]
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.(NON CSR) [999-1-356]
Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. [13-15-1]
Supplying and erecting ABC powder type fire extinguisher as per IS 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. [999-1-341]
Supplying, installing, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation on with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/EP [13-1-5]
Supplying, installing, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type multi stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete as per specification no. FF-MFP/JP [13-2-2]
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP (13-4-2)
Supplying, installing, testing and commissioning of fire pump control panel (FCP) of cubical construction floor mounted type fabricated from minimum 2 mm thick CRCA sheet compartmentalised with hinged lockable doors with enclosure protection class IP54 duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) cable alley interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories mountings and internal wiring with adequate size copper conductor cable earth terminals numbering etc. complete in all respect suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories wiring & cabling along with allied accessories with following incoming and outgoings suitable for automatic & manual operation on 415V 3 phase 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby alternate run per start in auto mode) comprises of the following features & switchgears 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-2]
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-3]
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-4]
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-5]
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-6]
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-7]
Providing G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-8]
Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system. [13-6-9]
Supplying fixing testing and commisioning of flexible sprinkler connection 1000 mm length unbraided flexible pipe UL Listed with following accessoires. [11-3-118]
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler 15 mm (½ ) dia. NBCM Body chrome finished 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. [13-12-1]
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-19]
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-20]
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV [13-7-21]
Supplying and erecting 75/80 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-27]
Supplying and erecting 150 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-29]
Supplying and erecting 200 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-30]
Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV [13-7-3]
Supplying and erecting 80 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV [13-7-1]
Supplying and erecting 20 mm dia gun metal gate valve complete with PN16 pressure rating as per specification no. FF-VL/GV [13-7-31]
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating as per specification no. FF-VL/GV [13-7-32]
Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating as per specification no. FF-VL/GV [13-7-33]
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV [13-7-35]
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV [13-8-2]
Supplying and erecting 63mm dia reinforced rubber lined (R.R.L.) hose pipe 15m in length fitted with necessary accessories complete as per specification no. FF-FFA/RRL [13-8-4]
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ [13-8-8]
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC [13-8-10]
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia for supplying water in fire tank complete as per specification no. FF-FA/FMC [13-8-11]
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT [13-8-12]
Supplying and erecting 20/25mm dia gun metal air release cock with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV [13-8-13]
Supplying and erecting 100 mm dia. pressure gauge 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve erected with provided G.I. pipe elbow etc. complete as per specification no. FF-FFA/PG [13-8-14]
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve G.I. nipple elbow etc complete as per specification no. FF-FFA/PS [13-8-15]
Supplying and erecting brass orifice plate having 6 mm. thickness 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP [13-8-16]
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve hose pipe hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8 x6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-20]
Supplying, installing, testing and commissioning of beam smoke detector four wire single ended reflected type with 8 receiver having digital display for easy alignment adjustable sensitivity & heater kit for transmitter/receiver and reflector with necessary connections on suitable back box. The protection range of beam detector is 70 to 100 m. [13-9-5]
Supplying, installing, testing and commissioning of optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD [13-9-3]
Supplying, installing, testing and commissioning of manual call point (Pill box) with break glass push button and flip abort switch or agent release switch in metal enclosure complete as per specification no. FF-FAAS/MCP [13-9-7]
Supplying, installing, testing and commissioning of hooters having high (100dB 1m) and low (94dB 1m) volume setting group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR [13-9-8]
Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories 16x2 Character LCD Display provision for zone wise contact and beep sound alarm suitable to operate on 120-220 V AC 0 - 49 Deg C 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP [13-9-14]
Supplying, installing, testing and commissioning of FR XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-10]
Supplying, erecting, testing and commissioning of 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR [13-11-1]
Supplying, erecting, testing and commissioning of 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC [13-11-2]
Supplying, erecting, testing and commissioning of stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector stereo jack complete as per specification no. FF-PA/MIC [13-11-3]
Supplying, erecting, testing and commissioning of rust free microphone floor stand of chrome plating/powder coating or S.S. material 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete. [13-11-4]
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC [13-11-6]
Supplying, erecting, testing and commissioning of 1.0 sq. mm speaker wire complete. [13-11-9]
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site good complete. [16-1-7]
Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. [3-11-77]
Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps) (1.2x 1.2 x0.8)= 1.15 x 6 = 6.9 cum for overhead tank (1.8 x 1.8 x 0.9)=2.91 x 2= 5.82 cum total (6.9+5.82)= 12.72 Cu-M [16-3-5]
Supplying and erecting of fire Exit & Eire Exinguisher signlge Indicating the floor-numtber in words & syslem(Fire Exiinguisher & Accessories ) [999-1-370]
Providing Air Conditioning System For The Proposed Multipurpose Hall Building At- New Mahsul Bhavan Building PremisesShirdi,Tal-Rahta,Dist-Ahmednagar ( Part C-Sub Work No. 07 ) Supply installation testing and commissioning of double-skin type horizontal floor-mounted top / side discharge air handling unit Cfm 15000 cfm oF (3 w.g. static pressure) having thermal break profile complete with air-tight casing using gaskets and self-adhesive tapes and 0.8 mm thick pre-coated outer skin and 0.6 mm thick gi inner skin 45±2 mm thick double skin panel with pressure injected CFC & HCFC free PUF having k value of 0.02 W/°C/m & density 40 kg/m³ AMCA certified energy efficient plug fans with backward curved impellers for high static pressure mounted on aluminium extruded siderail base frame EU4 pre-filter and EU7 fine filter (shall be mounted on a common frame) Multi connection DX cooling coil with anti-corrosion aluminium fins suitable high efficiency (IE3) TEFC squirrel cage induction motor PVC/nylon hinges & handles view port and marine lamp limit switch SS-304 drain pan vibration isolators/rubber pads (minimum 1 thick) inspection windows / doors mixing box and supply / return / fresh air openings fitted with aluminium volume control dampers complete all as specified and directed by the engineer-in-charge. [999-1-315]
Supply installation testing and commissioning of double-skin type horizontal floor-mounted top / side discharge air handling unit Cfm 35000 oF (3 w.g. static pressure) having thermal break profile complete with air-tight casing using gaskets and self-adhesive tapes and 0.8 mm thick pre-coated outer skin and 0.6 mm thick gi inner skin 45±2 mm thick double skin panel with pressure injected CFC & HCFC free PUF having k value of 0.02 W/°C/m & density 40 kg/m³ AMCA certified energy efficient plug fans with backward curved impellers for high static pressure mounted on aluminium extruded siderail base frame EU4 pre-filter and EU7 fine filter (shall be mounted on a common frame) Multi connection DX cooling coil with anti-corrosion aluminium fins suitable high efficiency (IE3) TEFC squirrel cage induction motor PVC/nylon hinges & handles view port and marine lamp limit switch SS-304 drain pan vibration isolators/rubber pads (minimum 1 thick) inspection windows / doors mixing box and supply / return / fresh air openings fitted with aluminium volume control dampers complete all as specified and directed by the engineer-in-charge. [999-1-316]
Supply Installation testing & commissioning of megha condensing units 38.7 Tr. Condensing unit shall be complete with hermatically sealed rotary/ tandem type compressor Including anti corrosive coating. R410A refrigerant The units should be complete with condensing unit controls control panel wiring refrigerant piping and all accessories for odu required for a complete system. The wiring and insulated refrigerant piping shall be as required as per the schematic drawing. Power supply for the ODU will be provided near unit and contractor has to take care. ODU should be BMS compactible. [999-1-317]
Supply Installation testing & commissioning of megha condensing units 82 8 Tr. Condensing unit shall be complete with hermatically sealed rotary/ tandem type compressor Including anti corrosive coating. R410A refrigerant The units should be complete with condensing unit controls control panel wiring refrigerant piping and all accessories for odu required for a complete system. The wiring and insulated refrigerant piping shall be as required as per the schematic drawing. Power supply for the ODU will be provided near unit and contractor has to take care. ODU should be BMS compactible. [999-1-318]
Supply, fabrication, installation and testing of flexible canvas connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete. [3-11-82]
Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629 1985 to be used for fabrication of boxes panel boards etc. including cutting bending drilling welding riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. [6-1-2]
Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629 1985 to be used for fabrication of boxes panel boards etc. including cutting bending drilling welding riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. [6-1-3]
Supplying and erecting GI sheet 1 mm (20 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629 1985 to be used for fabrication of boxes panel boards etc. including cutting bending drilling welding riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. [6-1-4]
Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2017. [3-11-83]
SSupply & installation of acoustic insulation of duct with open cell Nitrial rubber insulation material with density 140-160 kg/m3 10 mm THK [999-1-317]
Adjustabl Jet nozzel with RAL 9010 shade & Swirl unit for tow-step reduction of the throw distance due to air control blades with unique saw tooth edges. Flange face cover ring swirl Uriit and cap should made of ABS.plastic UL94 V-0 flame retardant & spherical nozzel casing made of galvanised sheet steel. The Sound power level of the air-regeDerate noise measured should be according to EN ISO 5135 makes-TROX TJN [999-1-318]
Supplying and erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete. [3-11-85]
Supplying, erecting, testing and commissioning of manually operated opposed blade duct mounted flanged volume control dampers of required sizes in GI construction with operating mechanism mounting arrangement rubber refrigerant kits etc. complete. [3-11-80]
Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for 1TR window/split AC unit. [3-10-25]
Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 41.3mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-89]
Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 34.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-90]
Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. [3-11-91]
Supplying, laying / fixing, testing and commissioning of of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports hangers clamps vibration isolators and fittings such as bends tees valves gauges strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages fungal growth flame spread water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete. [3-11-92]
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]
Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC [4-2-20]
Supplying and erecting 40/50 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC) thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC [4-2-21]
Miscellenous civil work such as breaking holes & wall opening as per site conditions and making good for the ducting pipes sleeves & cut-outs etc. Finish painting by others. contractor should be paint of all exposed metal surfaces of equipments and components with appropriate colour. Air-tight fire doors with minimum one hour fire rating for Air Handling unit rooms fan rooms and other equipment rooms. Cutting holes chases and the like through all types of non structural walls and finishing for all services crossings including sealing frame work fire proofing providing sleeves cover plates making good structure and finishes to an approved standard. [999-1-319]
Supplying and erecting automatic control panel for 3 Ph 415 volt A.C. Submersible/centrifugal pump set up to 20 HP consisting of Star Delta starter having relay range 13-21 Amp S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc. [12-4-21]
Providing and erecting 4 Pole MCCB 415V 630A rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-5]
Providing and erecting 4 Pole MCCB 415V 200A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-2]
Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1]
Supplying and erecting terminal spreaders suitable for 4 pole above 630A up to 800A MCCB (Set of 8) [5-11-10]
Supplying and erecting terminal spreaders suitable for 4 pole above 250A up to 400A MCCB (Set of 8) [5-11-8]
Supplying and erecting terminal spreaders suitable for 4 pole up to 100A MCCB (Set of 8) [5-11-6]
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB. [5-11-15]
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB. [5-11-14]
Supplying, erecting and marking SPMCB 0.5A to 5A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-1]
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1]
Supplying and erecting self-locking arrangement with keys in duplicate made of brass of grade 1 compliance to IS 729-1979 duly erected flush with surface of panel / cupboard [6-1-20]
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB [6-2-11]
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display external CT operated calibrated for suitable to operate on 500V 0 to 1000A having accuracy class of 0.5 AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. [6-3-7]
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. [6-3-8]
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2]
Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green 230 / 250V on provided box / panel with necessary material wiring & connections etc. [6-5-5]
Supplying and erecting LED type indicating pilot lamp with LED colour blue 230 / 250 V on provided box / panel with necessary material wiring & connections etc. [6-5-6]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982 [6-1-15]
Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 400A [5-10-28]
Supply Installation Testing & Commissioning of Ahu & Odus central control panal ( PC monitoring systems ) System should have facilities for ahu on indication compressor on indication start stop temperature setting mode contrl group control emergency stop BMS access and fault . [999-1-320]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-23]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-21]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-17]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-16]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-31]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-14]
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS 15652 – 2006 having 2 mm thickness up to 3.3 kV [10-6-25]
Providing Street Light For The Proposed Multipurpose Hall Building At- New Mahsul Bhavan Building Premises Shirdi,Tal-Rahata, Dist-Ahmednagar ( Part C - Sub Work No. 08 ) Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14]
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 4400 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. [2-4-4]
Supplying, erecting and marking SPMCB 0.5A to 5A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-1]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-27]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-9]
Providing and erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL [8-2-12]
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-21]
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-22]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). [16-3-9]
Providing Submersible Pump For The Proposed ( P + 2 FLOORS) Central Admin Building At- New Mahsul Bhavan Building Shirdi,Tal-Rahta,Dist-Ahmednagar ( Part A - Sub Work No. 09 ) Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10]
Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12]
Supplying, fixing, and commissioning MCB type change over switch 4 pole 25A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS [5-3-24]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nuts bolts etc. complete. [6-1-12]
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars 500V 100A having 15mm (Width) X 3 mm (Thickness) with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB [6-2-1]
Supplying and erecting 525 V 3 phase 50 Hz. MPP type capacitor having minimum overcurrent capacity of 1.8 In peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of metalised polypropylene condensers (MPP) with the standard capacities of 2 3 5 7 10 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee. [6-5-3]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-31]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP [9-1-3]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 390 LPM discharge at 55 to 11 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP [12-2-1]
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50 c/s. A.C. supply having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP [12-3-2]
Supplying and erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. [12-4-9]
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14]
Supplying and erecting Water level controller 230/415 V A.C. Four way under ground & Over head tank operation only. [12-4-15]
Supplying and erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos) [12-4-16]
Supplying and erecting automatic control panel for 3 Phase 415 volt A.C Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc . [12-4-17]
Supplying, installing, testing and commissioning of FR XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-11]
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. [16-5-6]
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete. [16-5-18]
Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. [16-6-15]
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. [16-6-21]
Harsh Constructions Pvt Ltd
M/s. DeltaTechs Construction Private Limited
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid