Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹22.4 L+₹2.4 L (12.2%)Rejected-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L2 | Rejected-AOC higher rate | |
| 3 | L3₹22.5 L+₹2.5 L (12.5%)Rejected-AOC B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L3 | Rejected-AOC higher rate |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
2 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NEW DELHI
GE NEW DELHI
CA NO GE/ND27/202223 REPAIR/ MAINT OF COOLING APPLIANCES WINDOW TYPE /SPLIT TYPE/ CASSETTE TYPE ACs AT HQ IDS UNDER GE NEW DELH
2022_MES_532230_1
GE/ND-27/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE NEW DELHI
REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹80,000
Yes
8 Sept 2022
20 Jun 2022
4 Aug 2022
20 Jun 2022
2 Aug 2022
4 Jul 2022
Amount
Labour for checking and attending complaints of ACs, water coolers, Refrigerators etc of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed.(any parts required for replacement shall be measured and paid separately under respective items) Note:-The contractor should detail minimum one AC Mechanic & one helper to attend complaints daily in HQ IDS,DAIRA.During working hours .
All minor complaints to be attended within 2 hours. If the complaint not attended/not completed with in 2 hours, recovery will be done as follows:- Attended between 2-4 hours @Rs 1000 between 4-12 hours @Rs 2000 For next every 12 hours @Rs 5000
Servicing of Window type AC 1.5/2 Ton capacity of any make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of AC(two times in a year )pre summer drive and pre winter drive ). Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
All as per item No 2 above but Split AC of any type and 1.5/2 Ton capacity. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
Supply only in replacement starting capacitor 80-100 Mfd suitable for AC 1.5/2 Ton Make : Usha/Epcos/Havells
Supply only in replacement Running capacitor 36 mfd 230 volt suitable for AC 1.5/2 Ton Make : Havells/Epcos/Tesla
Supply only in replacement running capacitor 45 mfd 230 volt suitable for AC 1.5/ 2 Ton . Make : Havells/Epcos/Tesla
Supply only n replacement Running capacitor 6 mfd 230 volt Make : Usha/Epcos/Havells
Supply& only n replacement multi Running capacitor 50+6 mfd 230 volt Make : Usha/Epcos/Havells
Supply only in replacement Running capacitor 4 mfd 230 volt Make : Usha/Epcos/Tesla
Supply & charging gas refrigerant R-1434/R-22/R 410 A/ R-32 or as existing to window type AC up to 2 Ton capacity including removing of leakage if any and testing complete all as specified & directed by Engineer-in-charge. Make- Maffron/Refron
All as per item No 10 above but for Split AC of any type and 1.5/2 Ton capacity. Make- Maffron/Refron
All as per item No 10 above but for VRF AC ( 16 Nos 1.5 HP indoor and two no's outdoor 20HP and 16 HP ) of any type and 1.5/2 Ton capacity. Make- Maffron/Refron
Supply only in replacement starting relay suitable for 1.5/2 Ton capacity AC Make : Renutrol/Classic/Indfos
Supply only in replacement over load protector suitable for 1.5 Ton capacity AC Make : Pacific/renutrol/Hitech
Supply only in replacement thermostat switch suitable for 1.5/2 Ton capacity AC Make : Pacific/renutrol/Indfos
M&L for taking down of defective /unserviceable Rotary/reciprocating compressor of window type AC capacity 1.5/2 TR and replacing the same with new compressor Rotary/Reciprocating type capacity 1.5/2 TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make :Kirloskar/ Carrier/Tecumseh/Copeland/ make existing at site
M&L for taking down of defective /unserviceable Rotary /Reciprocating compressor of split type AC capacity 1.5 /2 TR and replacing the same with new compressor as per the existing type and capacity 1.5 /2TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/Carrier/Tecumseh/Copeland/ make existing at site
M&L for taking down of defective /unserviceable compressor of Inverter type split AC capacity 1.5 /2 TR and replacing the same with new compressor as per the existing type and capacity 1.5 /2TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/Carrier/Tecumseh/Copeland/ make existing at site
Supply & fix in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity any type split AC type Acs
Supply & fix in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity window type Acs
M&L for taking down existing unsv blower motor (Indoor) capacity 1/4,1/5 HP single/double shaft as per existing and refixing with new blower motor in replacement as per existing model on site suitable for Split type ACs 1.5/2 Ton complete all as specified and directed. Make : LG/Career/Voltas/Hitachi.
M&L for taking down existing unsv out door fan motor and fixing of new fan motor capacity 1/4,1/5 HP single/double shaft as per existing model suitable for any type Split ACs 1.5/2 Ton complete all as specified and directed. Make : LG/Career/Voltas/Hitachi.
Supply & fix replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 70/.0076 (2.5 sqmm). Make:- Kalinga/Polycab/Havells/Finolex
Supply & fix replacement PVC insulated flexible copper conductor 4 core 1100V Grade of size 70/.0076 (2.5 sqmm). Make:- Kalinga/Polycab/Havells/Finolex
Supply & fix in replacement condenser fan blade made out of aluminium /plastic suitable for upto 2 Ton capacity window type Acs.
Supply & fix in replacement condenser fan blade made out of aluminium /plastic suitable for upto 2 Ton capacity and for any type split Acs.
Supply & fix in replacement of evaporating air blower made out of aluminium/plastic suitable for upto 2 Ton capacity for window type AC all as specified and directed
Supply & fix in replacement of evaporating air blower made out of aluminium/plastic suitable for upto 2 Ton capacity for any type Split AC all as specified and directed
Supply only in replacement of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split AC units. Make:- Supreme/Gulf-o-flex/Superlon.
Supply only in replacement of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split AC units. Make:- Supreme/Gulf-o-flex/Superlon.
M & L for replacement of front grill suitable for window type ACs upto 2 Ton capacity of any Make as per existing size and shape.
M & L for replacement of reverse valve system suitable to 1.5/2 Ton split/window AC for heating option and includes copper pipe connection .(Gas charging shall be paid and measured under respective item)
M&L for taking down existing condensing coil by removing it from existing outdoor unit by using LPG blower and fixing of new condensing coil of suitable size/capacity for 1.5/2 Ton any type split Acs . Complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
M&L for taking down existing evaporating coil by removing it from existing indoor unit by using LPG blower and fixing of new evaporating coil of suitable size of existing make, capacity for 1.5/2 Ton any type split Acs. Complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
M&L for taking down existing condensing coil by removing it from existing outdoor unit by using LPG blower and fixing of new condensing coil of suitable size/capacity for 1.5/2 Ton window type Acs in replacement as per existing size/shape and as per existing make. Complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
M&L for taking down existing evaporating coil by removing it from existing indoor unit by using LPG blower and fixing of new evaporating coil of suitable size/capacity for 1.5/2 Ton window type Acs in replacement as per existing size/shape and as per existing make. Complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
M&L for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas R-12/22/134a for water cooler, Split type/Window type AC/ Deep Freezer /Refrigerator any size any capacity as on site complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement brass flare nut/connector heavy duty of size 6 mm/9 mm (1/4", 1/2") as per existing make.
M&L for Replacement of control processing board( Remote control kit) with hand set including replacement of current transformer, ICs, diodes, resistances, sensors etc complete for 1.5/2 Ton split type ACs of any make & model.
M&L for replacement of unsv display along with PCB suitable for Split type AC 1.5/2 TR with new PCB along with display unit. Make-Hitachi/Voltas/Carrier/Daikin
M&L for opening and taking down existing unsv PCB along with display unit and fixing of new PCB along with display unit suitable for Indoor unit of Inverter AC of capacity1.5/2 Ton split type AC . complete all as specified and directed by Engr-in-Charge.
M&L for opening and taking down existing unsv PCB and fixing of new PCB suitable for Outdoor unit of 1.5/2 Ton split type AC inverter AC. complete all as specified and directed by Engr-in-Charge.
M&L for taking down unsv condenser fan motor of outdoor unit inverter type and supply and fix in replacement DC motor 125 W suitable for outdoor unit of Inverter type AC of capacity 1.5/2.0 Ton. Complete all as specified and as directed by Engr-in-Charge
M&L for taking down existing unsv compressor of Inverter type AC 1.5/2 TR and replacement of same by new hermetically sealed rotary compressor of capacity suitable for Inverter type AC 1.5/2 Ton refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge
Supply and fixing window AC kit 1.5/2.0 TR with sensor complete with condensing coil, blower and motor suitable to existing model and make AC all as specified and directed. Make:- LG, Napolean & Skoda
S & F split type AC indoor unit kit 1.5 /2 TR capacity complete with cooling coil, blower with motor, PCB and remote complete with fixing plate suitable to existing model and make AC all as specified and directed. Make- Hitachi/LG/Daikin
S & F split type AC outdoor kit 1.5 / 2 TR complete with condensing coil, condenser fan motor suitable to existing model and make iron grill, suitable for outdoor unit and flair nuts for connection of Copper pipe all as specified and directed. Make- Hitachi/LG/Daikin
Supply & fix in replacement direction changer louver motor ( swing motor) suitable for any type split type Acs 1.5/2 capacity as per existing make and model
Supply & fix in replacement cordless Remote for any type split ACs suitable for 1.5/2 Ton AC as per sample. Make- Hitachi/Voltas/LG
Supply & fix in replacement cordless Remote for ACs suitable for 1.5/2 Ton window AC as per sample. Make- Hitachi/Voltas/LG
M&L for comprehensive checking of entire VRF units once in a quarter capacity 32 HP installed at South Hutments including replacement of PCB kit of indoor units (16 Nos ) fan motor, compressor as per existing , brazing to joints. gas top up, repair to display along with connected accessories, short circuiting of wiring rectification and its replacement, including repair/ replacement to LCD display servicing or descaling of cooling fins and removal of dirt by pressure washing etc. It comprises 16 no's indoor unit .complete all as specified and directed. Note: Entire work shall be carried out by OEM /OEM authorised dealer
Servicing of Water cooler/Refrigerators of 80/165/310 ltr capacity of any make / model by cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning, greasing, oiling of fan motor and checking of electric circuit for smooth functioning Twice a year complete all as specified and directed by Engr-in-Charge
Supply & charging the gas refrigerant R-134 or as existing to water coolers up to 80 ltr capacity including removing of leakage if any and testing complete all as specified & directed
Taking down of defective /unserviceable reciprocating compressor of Water Cooler 80 L and replacing the same with new compressor reciprocating type capacity upto 80 Ltrs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make:- LG/Kirloskar/Hitachi/Tecumseh/Copeland
M&L for taking down existing condensing coil from water cooler of any capacity and replacement by new Condenser coil as per existing capacity including brazing and dehydration by creating vacuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system. Complete all as specified and as directed by Engr-in-Charge
M&L for taking down fan motor of water cooler capacity upto 80 Litres and replacement of the same by new fan motor as per existing on site upto capacity 80 litres along with fan blade and along with all mountings complete all as specified and as directed by Engr-in-Charge
M&L for taking down existing unsv condensing coil from Refrigerators of any capacity and replacement by new Condenser coil as per existing capacity upto 310 Ltrs including brazing and dehydration by creating vacuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system. Complete all as specified and as directed by Engr-in-Charge
M&L for taking down unsv fan motor of refrigerators of any capacity upto 310 Litres and replacement of the same by new fan motor as per existing on site upto capacity 310 litres along with fan blade and along with all mountings complete all as specified and as directed by Engr-in-Charge
M&l for Taking down of defective /unserviceable reciprocating compressor of Refrigerator capacity upto 310 Ltrs and replacing the same with new compressor reciprocating type capacity 310 Ltrs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/LG/Tecumseh
Supply & charging the gas refrigerant R-134a or as existing to Refrigerators up to 310 ltr capacity including removing of leakage if any and testing complete all as specified & directed
Supply only in replacement of unsv starting relay suitable for 165 to 310 ltr capacity Refrigerator
Supply only in replacement of unsv over load protector suitable for Refrigerator capacity upto 310 ltrs
Supply only in replacement thermostat switch suitable for Refrigerator capacity upto 310 L
S & F In replacement Voltage stabilizer 2 to 5 KVA copper wounded comprising of digital display ,digital ammeter and digital voltmeter suitable for 1.5/2 TR split/window AC complete all as specified and directed
S&F in replacement of plug top 3 pin, 15 Amps, 230 volts, 50 Hz AC complete all as specified.
M&L in replacement modular Plug & socket board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz , with MCB SP 20-32 Amps complete all as specified and as directed by Engr-in-Charge. Make- Havells/Legrand
S&F in replacement of PVC insulated and PVC sheathed, flexible copper conductor cable 3 core, 1100 volts grade, multi stranded type of size 6.0 sqmm complete all as specified.
S & f body of desert cooler suitable for 65 ltr capacity made of metallic stell sheet 2mm thick comprising of three removable covers complete all as specified and directed
S & F heavy duty motor suitable for 65ltr capacity desert cooler comprising three nos blade made of metalic steel complete all as specified and directed
S & F water pumping motor suitable for 65 ltr capacity desert cooler comrising of three numbers rubber pipe connected to motor and outer surface complete all as specified and directed
M&L for taking down of desert cooler and Servicing of Desert cooler of any type/ capacity cleaning of tank, painting with black paint after cleaning including checking of electric circuit for smooth functioning of desert cooler complete all as specified and directed.
Supply and fix in replacement of desert cooler pad (in set of three) suitable for cooler of any make/size as required at site complete all as specified & directed.
Material & labour taking down of desert cooler fan motor and transporting the unsv motor to workshop for rewinding of desert cooler fan motor with supper enamelled copper winding wire of same gauge including replacement of insulating material, bushes, bearing and shaft after taking out burnt wire including transportation to civil workshop complete all as specified & directed.
Supply & fix in replacement item of ON/OFF switch of desert cooler complete all as specified.
Supply & fix in replacement of item of step type desert cooler regulator complete all as specified.
Supply & fix in replacement of drain pipe PVC flexible, spring type of size 15/20 mm dia as per site requirement complete all as specified.
M & L for Shifting of window type ACs 1.5 /2.0 TR capacity including removing of connected accessories all as directed by Engr -in- charge
M & L for Shifting of Split type Acs 1.5 /2.0 TR capacity including removing of indoor unit, out door unit and connected accessories all as directed by Engr -in- charge
M& L for cutting of walls to fix the window AC 1.5/2 TR as per existing shape and size and maintaining the surface as per existing condition complete all as specified and directed Note :Rate of plywood ,cement putty and paint included in the quoted rates
SNOWY ENGINEERING INC
HONEY COLLECTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .