Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹35.8 L+₹85,754 (2.45%)Rejected-Finance HOUSE NO 2 SATGAON MAIN ROAD NEAR BAILEY WATER FACTORY P O UDAYAN VIHAR DIST KAMRUP METRO GUWAHATI ASSAM 781171 | GUWAHATI | KAMRUP METRO | ASSAM | 781171 | L2 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹41.8 L
EMD Value
₹83,650
Closing Date
22 Dec 2021, 6:00 pmClosed
GE Narangi
GE Narangi C/O 99 APO
PROVN OF RAIN SHED AT BLDG NO 58 AND STORAGE ACCN NEAR BLDG NO T 11 UNDER GE NARANGI
2021_MES_490352_1
8703/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE Narangi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Narangi
₹83,650
Yes
15 Feb 2022
25 Nov 2021
25 Dec 2021
25 Nov 2021
22 Dec 2021
9 Dec 2021
Amount
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surfaces in soft/loose soil complete all as specified & as directed.
M&L surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil.complete all as specified and directed.
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.
Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
M&L fo rsand filling under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L for hardcore of broken or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified and as directed.
M&L for PCC 1:2:4, type B2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
M&L for reinforced cement concrete M-25 design mix as in foundations, including rafts, footings, foundation beams; plinth beams bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete M-25 design mix as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for reinforced cement concrete M-25 design mix as in beams, seimic bands, cantilevers, bressumers and lintels complete all as specified as directed.
M&L for reinforced cement concrete 1:2:4 type B-1 using 20mm graded aggregated as in slabs supported on walls , beams and columns in floors, roofs, landings, balconies, casnopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for reinforced cement concrete M-25 design mix as in slabs supported on walls , beams and columns in floors, roofs, landings, balconies, casnopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for reinforced cement concrete M-25 design mix as in chajjahs complete all as specified as directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces complete all as specified and directed.
M&L formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressumers, lintels over 1.5m clear span, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc. for fair finished flat surfaces of concrete complete all as specified and as directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works, not exceeding 200mm thick ( Horizontal or sloping) complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia as in reinforcement bar complete all as specified and as directed.
M & L for mild steel TMT bars 6 to 8mm mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia as in reinforcement bar complete all as specified and as directed.
M&L for mild steel TMT bars 6 mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour as directed having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, eave board fixed with self tapping screw as specified and directed.
S&F Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified & as directed.
S&F Rolledmld steel roof trusses ( framed) trussed purlins, crane gantries, rails and fastenings and heavy brackets framing ( Beam, tee, angle, channel or flat section) including distace pieces, cleats etc confirming to Fe 410-W ( Gde E-250 Quality A)complete all as specified & as directed.
S&Fmld steel confirming to Fe 290 grade E-165 as in wind ties fixed at eaves and ridge level etc complete all as specified & as directed.
S&FMild steel framed work such as grills,gratings,etc.with ends of bars shouldered and/or riveted,or forged into spikes,framed guard bars, barred iron doors,ladders, framed balusters, walk ways,railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165.
M&L brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L for 100mm thick PCC type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base complete all as specified and directed.
M & L for 100mm thick PCC 1:2:4, type B1 (using 20mm graded stone aggregate) as in floor complete all as specified and as directed.
M&L for providing 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in plinth protection. Plinth protection shall be laid in alternate bays n exc 2 sqm, 10 mm thick joints shall be provided, joint shall be filled with bitumen mastic, bitumen mastic shall comprises of 1 part of hot bitumen 85/25 and 3 parts of sand all by weight finished cement concrete surface even and fair without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying a coat of wall care putty of 1mm average thickness and sanding the surface till smooth finish surface is obtained and a coat of alkali resistant primer and two coats of oil bound distemper complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying three coats of white wash complete all as specified and directed.
M&L coloured Non-skid ceramic tiles 7 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match existing surfaces over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L coloured Non-skid ceramic tiles 7 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38Sqm as in vertical surfaces such as skirting. dados etc . set and jointed in neat cement slurry and pointed in white or coloured cement to match existing surfaces over and including 10mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured joint free tiles in vertical surface 300x 200x 7mm/ 450X 350X 7mm thick with and including 10mm thick CM 1:4 backing coat, set and jointed in neat cement slurry and pointed in white or colour cement to match etc complete all as directed.
M&L for 10mm thick Vitrified tiles light shade area of each tile n exc 0.36sqm laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L for 20mm thick granite ( any type) machine cut ,as in vertical surfaces like skirting , dados, steps, jambs, pillars, window cills, cookong platforms and the like laid over cement screed of 15mm thick in CM 1:4 including pointing in white cement 1:2 using marble dust with admixtures of pigments match the shade of granite stone including rubbing and polishing complete all as specified and as directed.
M&L pre-polished cement concrete chequered tiles area of each tiles exc 0.06 Sqm but n exc 0.11 Sqm and 25 mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with pigment to match with the tiles over and including screed bed of 15 mm thick in cement mortar (1:6) complete all as specified and directed.
S&F suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner shall not be placed at more than 450mm from the adjacent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid complete all as specified and as directed.
S&F in repair False ceiling with 12mm thick of size 600mm X 900mm Plaster of paris sheets fixed with machine screws on and including GI channel 16 gauge grid work main joists placed at 750mm, centre to centre and cross joists 450mm centre to centre hanging with 6mm dia GI wire suspenders roof " J" hook bolts and nuts and treating the POP sheets with thin layer of POP with gypsum binder till smooth surface is acheived and applying two coats of plastic emulsion paint of approved colour over a coat of primer matching with the colour of ceiling sheets complete all as specified and as directed.
S&F decorative flowers design/ moulding using POP of dia not exceeding 40cm in circular shape as per approved design fixed in position including preparing the surface and applying two coats of plastic emulsion paint over a coat of primer matching with the colour of ceiling sheets complete all as specified and as directed.
S&F decorative cornices/ moulding using POP of cross sectional dimension exceeding 13sqcm and not exceeding 25 sqcm as per approved pattern and design fixed in position including preparing the surface and applying two coats of plastic emulsion paint over a coat of primer matching with the colour of ceiling sheets complete all as specified and as directed.
M&L for anodized aluminium push pull type partly panelled and partly glazed door shutter (single leaf / double leaf) having top rail of section 85.00mm×44.45mm×2.00mm, bottom rail of section 85.00mm×44.45mm×2.00mm thick, door verticals of section 44.45mm×44.45mm×2.00mm thick and lock rail of section 85.00 mm× 44.45mmx2.00mm thick with aluminium anodized frame of section 63.50mm x 33.10mmx2.50mm thick including necessary jointing cleats, glazing clips, rubber packing snap beading, screws, handle and locking arrangements etc, including 12mm thick pre laminated particle board, interior grade pre laminated with decorative face laminations both sides on bottom panel and 5.5 mm thick float glass tinted quality on top panel and including 1 No of aluminium door closer per leaf (Diecast) body hydraulically regulated designation No 3 universal type complete all as specified and as directed. (Note : Door closer shall be measured and paid separately)
M & L three track aluminium sliding window with approved make of following extruded section of anodised glazed shutter of aluminium section A series M-2014 as per standard engineeering practice including all accessories including 4.00mm thick tinted glass panes, rubber beading etc complete all as specified and as directed. (i) Top and bottom shutter - 37.5x15x1.3mm thick ( 20690). (ii) Shutter interlock - 37.50x23x1.30mm thick ( 20689). (iii) Shutter side ( Handle) - 37.5x23.7 x1.3mm thick ( 20689) (iv) Frame bottom - 75x26x1.00mm thick ( 20671) (v) Frame top and sides - 75x26x1.00mm thick ( 20672).
M&L for preparation of new or previously untreated surfaces of steel and steel based surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel and steel based surfaces of any description, not otherwise described not exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
S&F GI tubing 25mm dia light grade for cable protection and fixing to existing pole with mild steel flat iron clamp of size 25x3mm including nuts bolts etc complete all as specified and directed.
S&F GI tubing 32mm dia light grade for cable protection and fixing to existing pole with mild steel flat iron clamp of size 25x3mm including nuts bolts etc complete all as specified and directed.
M & L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) laid/fixed in and including concealed in PVC rigid conduit on walls/ceiling, and also including sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for One light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item No 55 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board.
All as per item serial No 55 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches.
All as per item No 55 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
S&F switch piano, flush type single pole one way 5 Amps 240 volt complete all as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as directed.
S&F switch socket combination outlet , 2-in-1, 5 Amp flush type complete all as directed.
S&F switch socket combination multipurpose, 5 in 1, , 5 & 16 Amp flush type complete all as directed.
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as directed.
S&F stepped type electronic fan regulator, two module size, flush type complete all as directed.
M & L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) laid/fixed in and including PVC conduit of not less than 20mm dia with all fittings and accessories including suitable modular PVC box or pressed steel modular boxes made out of 1.6mm thick mild sttel including cover plate with frame laid /fixed in concealed on walls/ceiling, for One light/fan/exhaust fan/ bell point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item serial No 65 here-in-before but One 3 pin socket outlet 5 amps on the same board with other switches
All as per item serial No 65 here-in-before but One socket outlet 3 pin 5 Amp on independent board.
All as per item serial No 65 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable for 6 pin 15 Amp socket outlet on independent board and earth continuity wire with 2.5 sqmm cable.
All as per item No 65 here-in-before but wiring with 4 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination modular outlet on independent board with 4 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
S&F modular switch1 module 6 Amps 240 V single pole one way 240 volt complete all as directed.
S&F modular socket outlet 3 pin, 2-in-1, 6 Amps 2 module complete all as directed.
S&F modular switch socket combination outlet , 2-in-1, 6 Amp 3 module complete all as directed.
S&F modular switch socket combination multipurpose, 5 in 1, , 5 & 16 Amp 3 module complete all as directed.
S&F modular stepped type electronic fan regulator, two module size, flush type complete all as directed.
Supply and fixing in repairs modular north west outlet tiny trip C-25, 2 pole MCB 240 V 50Hz single phase motor startar current range from 11 Amp to 18 Amp 240V 50 Hz AC including top complete all as specified and directed.
S&F wall decorative fixtures in durable plastic body and designer mesh in gold finish suitable for 9 W LED lamp of B-22 including lamp of 9 W complete all as specified and directed. Make : Havells Cat No. LHFOECE1TZ1B014 or in equivalent of Bajaj/CG/Philips
S&F LED luminaires 600mmX600mm, 35/36 Watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders, LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable sizecomplete all as specified and as directed.
S&F round shape 12 Watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders, LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable sizecomplete all as specified and as directed.
S&F round shape 6 Watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders, LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable sizecomplete all as specified and as directed.
S&F regal batten for LED Tube rod pre-wired including LED tube double sided 1x20W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable & fix on 2 no. of PVC block complete all as directed. (Make:- Havells, Model No: REGALBATTENT8UPTO1X22WDSBSWH+CRSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Bajaj / Philips / GE / Crompton)
Supply and fixing building security light bracket made of GI pipe 40 mm bore medium grade (bend to shape), 2.00 metre long and fixed with Ms flat iron clamp(clamp shall be 40 x 5mm), nuts, bolts and washers on pole complete all as specified and directed.
Supply and fixing building security liminaires WSPD 48 Watts epoxy powder coated pressure die cast aluminium housing with weather proof gasket for LEDs and control gear compartments, pressure die cast aluminium frame with heat resistant toughened clear glass fixed with SS screws. CRee LED/Equivalent colour temp-5700 K +/-300 K lens , IP-66, lumen efficiancy >100, lm/w. surge protection, 4 KV internal ( built in) with twin core conductor complete all as specified and directed including testing on completeion. Make: Havells Cat No. ENDURAPEARNEOSL48WLED757SASYTOPC or equivalent in Philips/WIPRO/CG.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I complete all as specified and directed.
S&F Ceiling fan with blades, down rod, electronic regulator and accessories 230 V 1200mm sweep with minimum air delivery 210 CFM with service value 6.00 BEE five star rated with bushless direct current motor ( BLDC) complete all as specified and directed. Make : Usha/Orient/ Havells
S&F MCB DB, double door sheet metal enclosure TPN 4 way with 200 A rated bus bar with provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F MCB DB, double door sheet metal enclosure SPN 8 way with 200 A rated bus bar complete and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA, C-series marked fixing in DBs (DBs catered separately in this Schedule) (Make :- Legrand/ Siemens/Schnider/L&T)
S&F MCB Tripple pole & neutral 40 to 63 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F MCBs, SPN 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 3 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 3 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid)
M&L for Sub class ‘B’ old size well burnt brick laid flat in trenches over the cable for protection of LT cable complete all as specified and as directed.
LAXMI CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .