| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC HOUSE NO 415 ALIKAN ROAD MANDI DABWALI SIRSA HARYANA 125104 | MANDI DABWALI | SIRSA | HARYANA | 125104 | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹28.6 L+₹2.3 L (8.68%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹33.7 L+₹7.4 L (28.3%)Rejected-Finance WARD NO 13 NEW SURATGARH | SURATGARH | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹33.8 L+₹7.5 L (28.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹34.3 L+₹8.0 L (30.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹96,900
Closing Date
11 Nov 2023, 6:00 pmClosed
Lt Col Priyesh Srivastava
GE AF SURATGARH
REPAIR/REPLACEMENT OF ELECTRICAL WIRING, FITTING AND FIXURES AT CERTAIN OMQS AND PROVISION OF DEFICIENT GEYSERS AND CEILING FANS AT MD ACCN AT AF STN SURATGARH
2023_MES_624267_1
8113/E8
Open Tender
Civil Works
Item Rate
180 days
Suratgarh
As per tender documents
10 documents required · 10 mandatory
₹500
GE AF SURATGARH
₹96,900
Yes
18 Nov 2023
20 Oct 2023
13 Nov 2023
20 Oct 2023
11 Nov 2023
4 Nov 2023
Amount
BOQ (REPAIR/REPLACEMENT OF ELECTRICAL WIRING, FITTING AND FIXURES AT CERTAIN OMQS AND PROVISION OF DEFICIENT GEYSERS AND CEILING FANS AT MD ACCN AT AF STN SURATGARH.)
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litter, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and directed.
S&F Ceiling fan of sweep 1200 mm, Mounting Type Downrod Mount;Low Power consumption 51 W, Speed 380 RPM, Air delivery 210 CFM,100% copper motor, double ball bearings, dynamically balanced blades,corrosion resistant high performance along with powder-coated blades for enhanced aesthetics consisting of 1 motor, set of 3 blades, set of 2 canopy, 1 down rod, 1 shackle assembly complete all as specified and directed.
S&F Exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers , complete all as specified and directed.
S&F in replacement sheet metal enclosures single pole and neutral earth enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps, 240 volts, complete all as specified and directed. Note : Cost of cutting, chasing and make good to existing surfaces are deemed to be included in the quoted rate by the contractor.
M&L for sub-main wiring (concealed) with two single core 4 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonry work to make good including 25 mm dia non-metallic PVC conduit fixed in wall including 2.5 sqmm copper earth continuity wire, accessories and connecting to earth dolly complete all as specified and directed by Engr-in-charge.
M&L for PVC Connections of 15mm size with PTMT nuts of length 450mm, complete all as specified and directed.
M&L for CP Bib tap cast copper alloy/brass fancy type of size 15mm bore with crutch or butterfly handle screwed down, screwed for iron pipeor for brass ferrule and fixed to position complete all as specified and directed.
M&L CP Stop cock/valves cast copper alloy/brass fancy type inside threaded 15 mm bore to connected position, complete all as specified and directed.
S&F GI pipe of size 15mm bore medium grade ISI marked including all fittings on wall in reqd position, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separate and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
Dismantling and taking down fluorescent tube light single/double of any wattage or size fitting for repair or replacement of burnt/worn out accessories or carrying to MES store (Accessories or components to be provided free for replacment by department), complete all as specified and directed.
Taking down unserviceable sub main wiring of any type/size including wires, conduits/batten etc, complete all as specified and directed.
Taking down unserviceable DB's box including MCB's of any size/rating, complete all as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volts grade FRLS cable of copper conductor multi stranded of size 1.5 sqmm (Nominal size) drawn through and including non metallic rigid PVC conduit medium grade, ISI marked not less then 20 mm dia with all accessories like tee, straight joint, L bend etc concealed in wall , ceiling , floor etc, pressed MS Sunken boxes in wall of required size and colour for switches and sockets, 1.5 sqmm (Nominal size) PVC insulated (green insulation) copper conductor FRLS earth continuity cable drawn with wiring and connected to common earth dolly all as specified for one light point/ceiling fan/exhaust fan controlled by one SP switch including making good distrubed surface, complete all as specified and directed. Note :- Cost for MS Sunken Boxes and Hylum sheets and cutting, chieseling and making good to existing surfaces shall deemed to be included in the quoted rate.
All as per Srl item No 14 here-in-before but for one light point controlled by Two, two way switch, complete all as specified and directed.
All as per Srl item No 14 here-in-before but for one bell point controlled by one bell push, complete all as specified and directed.
All as per Srl item No 14 here-in-before but for one 5 pin socket out let, 6 Amps on same board with the cable 1.5 sqmm size, complete all as specified and directed.
All as per Srl item No 14 here-in-before but for one 5 pin socket out let, 6 Amps on Independent board with the cable 1.5 sqmm size, complete all as specified and directed.
All as per Srl item No 14 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor FRLS cable PVC insulated including earth wire 2.5 Sq mm copper conductor FRLS cable connected to earth dolly complete, all as specified and directed.
S&F switch piano flush button single pole one way 5 amp 240 volts, complete all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 amps, flush type, 240 volts complete all as specified and directed.
S&F Socket outlet, flush type 2 in 1, 3 pin, 5 amps, 240 volts complete all as specified and as directed.
S&F switch piano flush type single pole two way 5 amps 240 volts, complete all as specified and directed.
S&F switch piano flush button single pole one way 15 amp 240 volts, complete all as specified and directed.
S&F bell push switch, single pole, one way flush type, 5 Amps, 240 volts complete all as specified and directed.
S&F of ceiling rose, surface type, 65mm x 50mm, 3 terminal complete all as specified and directed by Engr-in-Charge.
S&F of bell multi music type, 230 volt AC, single pole, complete, all as specified and directed by Engr-in-Charge.
S&F of lamp holder, PVC/polycarbonate type, insulated body with back plate of batten fitting complete all as specified and directed by Engr-in-Charge.
S&F of LED bulb 09 watt, complete all as specified and directed.
S&F LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED bulkhead luminaire 10 watt, wall/surface mounted complete with LED lamp 10 watt, all accessories, pre-wired including providing flexible copper wire, twin core cable PVC insulated sheathed, complete all as specified and directed.
S&F LED sleek mirror light fitting 10 watt provided with high output diffuser 2 feet, 230 Volts complete LED tube rod 10 watt with all accessories, pre wired and including connecting up with twin core copper conductor cable complete all as specified and directed by Engr-in-Charge.
Taking down ceiling fans of any sweep and any size including cable connections and disconnecting of fan blades and removing the fan with blades deposit to store yard as it is in working condition for further hanging in its original position or any other position including as per direction of Engineer-in-Charge including it's fitting and fixtures after carrying out service includes cleaning, greasing and oiling, painting of fan with one coat of synthetic enamel spraying painting including marking of MES number with black paint after preparation of surface reassembling the fan etc including testing complete all as specified and directed by Engr- in-charge. Note :- Any damage has to be made good by the contractor to make the item functional after testing.
S&F step fan regulator, 120W 230 volts, 50 HZ, AC. supply complete all as specified and directed.
Taking down exhaust fans of any sweep and any size including cable connections and removing the exhaust fan with blades deposit to store yard as it is in working condition for further fixing in its original position or any other position as per direction of Engineer-in-Charge including it's fitting and fixtures after carrying out service i.e. cleaning, greasing and oiling, painting of exhaust fan with one coat of synthetic enamel spraying painting including marking of MES number with black paint after preparation of surface reassembling the fan etc including testing complete all as specified and directed . Note :- Any damage has to be made good by the contractor to make the item functional after testing.
M&L for submain wiring with two single core 6.0 sq mm PVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit of size not less than 25mm dia, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 6.0 sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and directed. Note- (a) The two runs of single core cable and specified earth continuity conductor and PVC conduit with fitting acessories will be measured as one run. (b) Cost of cutting, chasing and make good to existing surfaces are deemed to be included in the quoted rate by the contractor.
S&F sheet metal enclosure for distribution board SPN (when MCBs to be used) 12 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed by Engr-in-Charge. Make: Havells/Leagrand/C&S. Note :- Cost of cutting, chasing and make good to existing surfaces are deemed to be included in the quoted rate by the contractor.
S&F sheet metal enclosure for distribution board SPN (when MCBs to be used) 8 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and directed by Engr-in-Charge. Note : Cost of cutting, chasing and make good to existing surfaces are deemed to be included in the quoted rate by the contractor.
S&F MCB SP, 6-32A,10KA complete all as specified and directed.
S&F MCB SPN, 32A ,10KA complete all as specified and directed .
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge, 8 mesh per linear inch, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with XPM JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified and directed.
Contract Amount shall be derived after affecting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
M/s Rohit Construction Co.
AGGARSAIN BUILDERS
Aman Enterprises
B K CONTRACTORS
Gupta Suppliers
Rasvinderpalandco
SRI SAI CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .