Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.1 L+₹1.2 L (10.5%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹14.6 L+₹2.7 L (23.2%)Rejected-Finance 94 D POCKET J AND K DILSHAD GARDEN DELHI DELHI 110095 UDYAM DL 02 0018675 07AHCPD1811D1Z7 B R | SHAHDARA | DELHI | 110095 | L3 | Rejected-Finance L3 | |
| 4 | L4₹14.7 L+₹2.9 L (24.2%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹17.4 L+₹5.5 L (46.5%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹17,000
Closing Date
13 Aug 2020, 2:30 pmClosed
DGM(PJ-CONTRACT)
Indian Oil Corporation Limited (Pipelines Division) A-1, Udyog Marg, Sector-1, NOIDA (UP) 201 301, INDIA
Maintenance of Notifier Fire Alarm system and Apollo Fire alarm system installed at Indian Oil Bhawan, Noida.
2020_PLHO_120720_1
PLCC/Fire_Alarm/HR/20049
Open Tender
Instrumentation - All
Works
730 days
PLHO Noida
Please refer Tender documents.
4 documents required · 4 mandatory
₹17,000
11 Nov 2020
23 Jul 2020
14 Aug 2020
23 Jul 2020
13 Aug 2020
1 Aug 2020
Amount
Maint of Apollo fire alarm system
Comprehensive Maintenance (Apollo): Comprehensive maintenance contract of Apollo addressable Fire Alarm and detection system including all smoke/ heat detectors (Below false ceiling and above false ceiling type), duct detectors, loop sounders, Manual call points, isolators, response indicators, cabling, Fire alarm panel etc installed at the 4th and 5th floor of Indian Oil Bhawan Noida including the monthly preventive maintenance visit and emergency visit as required as per the term and condition of the contract and upto the satisfaction of EIC.
Maint of Notifier Fire alarm system
Non Comprehensive Maintenance (Notifier): Maintenance of Notifier addressable Fire Alarm and detection system including all smoke/ heat detectors (Below false ceiling and above false ceiling type), duct detectors, directional sounders, Manual call points, isolators, modules, response indicators, cabling, Fire alarm panel, digital voice evacuation system, hooters etc as a whole installed at basement to 10th floor (except 4th & 5th floor) at Indian Oil Bhawan Noida including the monthly preventive maintenance visit and emergency visit as required as per the term and condition of the contract and upto the satisfaction of EIC.
Supply of spares for notifier fire alarm
Multi-sensor detector with acclimate feature (with dual thermal element and a photo element) with mounting base, LED, Address Switch to programme the detectors, mounting junction box, complete as required. (Model no- FAPT-851 + B501 or as per site requirement as per direction of Engineer-In-Charge)
Analog Addressable air duct smoke detector with an efficient housing design and sampling tubes complete as required. (Model no- DNRE + FSP-851 or as per site requirement as per direction of Engineer-In-Charge)
Addressable Manual Call Station for initiation of fire alarm. With mounting LED, Address Switch to programme the detectors, mounting junction box, complete as required. (Model No - F-MCP-GLASS or as per site requirement as per direction of Engineer-In-Charge)
Fault isolator module for isolating shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement, with mounting MS junction box, complete as required. (Model no- ISOX or as per site requirement as per direction of Engineer-In-Charge )
Addressable control modules for driving outputs like Hooters, firefighter jacks, AHU, dampers etc. With mounting MS junction box, completeas required. (Model no - FCM-1 or as per site requirement as per direction of Engineer-In-Charge)
Addressable monitor modules to give input to FAS, with mounting MS junction box, complete as required. (Model no - FMM-1 or as per site requirement as per direction of Engineer-In-Charge)
Response Indicator
Directional Sounders with 20 hz to 20 khz operating frequecy with minimum 8 distinct sound patterns to indicate corridors, Exit doors, Move upward, move down ward etc. to direct Occupants for fast & safe Evacuation as specified in NFPA 72 - 2010 edition, with mounting MS junction box, complete as required. (Model no - PF-24V or as per site requirement as per direction of Engineer-In-Charge)
2 C X 1.5 Sq mm Twisted Shielded copper multi stranded armoured, FRLS cable.
Fire panel supervised 70 db-84 db Ceiling-Mounted Hooter Cum Speakers as specified & same make as of panel. (Model no- P2RL or as per site requirement as per direction of Engineer-In-Charge)
Auxillary Power Supply unit for sounders etc complete as required (Model no- AMPS -24E or as per site requirement as per direction of Engineer-In-Charge)
Amplifier set including auxilliary power supply unit for Notifier panel complete as required (Model no- DAA2-5070E or as per site requirement as per direction of Engineer-In-Charge)
CARE SYSTEMS
National Safety Engineers
BOL-BOM CONSTRUCTION
ARC SERVICES
Ascent Networks Pvt Ltd
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .