| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | ₹26.2 L | L1 | Accepted-AOC THE LOWEST BIDDER |
| 2 | L2₹43.3 L+₹17.1 L (65.3%)Rejected-Finance | ₹43.3 L+₹17.1 L (65.3%) | L2 | Rejected-Finance NOT THE LOWEST BIDDER |
| 3 | L3₹43.3 L+₹17.1 L (65.3%)Rejected-Finance NADUA GAON POST NADUA DIKOM DIST DIBRUGARH ASSAM 786 101 | DIBRUGARH | DIBRUGARH | ASSAM | 786101 | ₹43.3 L+₹17.1 L (65.3%) | L3 | Rejected-Finance NOT THE LOWEST BIDDER |
| 4 | L4₹43.5 L+₹17.3 L (66.1%)Rejected-Finance | ₹43.5 L+₹17.3 L (66.1%) | L4 | Rejected-Finance NOT THE LOWEST BIDDER |
| 5 | L5₹44.7 L+₹18.6 L (70.9%)Rejected-Finance | ₹44.7 L+₹18.6 L (70.9%) | L5 | Rejected-Finance NOT THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Karman Infra Projects L2 | DEVI DAYAL CONSTRUCTION CO L1 | PARM BUILDERS L4 | M/S United Builders L3 | LOKESH ELECTRICAL L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, n exc 1.5 m wide and more than 1.5 m n exc 3.0 m in depth; for foundation, laying of cables etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 3.0 m in depth and getting out complete all as specified and directed | 1.19 | Cum | 150 ₹178.2 Lowest | 500 ₹594 | 450 ₹534.6 | 250 ₹297 | 300 ₹356.4 |
| 2.00 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr in Charge. | 0.6 | Cum | 3,500 ₹2,116.8 Lowest | 4,500 ₹2,721.6 | 4,000 ₹2,419.2 | 5,000 ₹3,024 | 5,000 ₹3,024 |
| 3.00 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr in Charge. | 6.05 | Cum | 2,300 ₹13,910.4 | 2,000 ₹12,096 Lowest | 2,800 ₹16,934.4 | 5,500 ₹33,264 | 7,000 ₹42,336 |
| 4.00 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping complete all as specified and directed by Engr in Charge. | 0.91 | Cum | 2,500 ₹2,278.12 Lowest | 4,000 ₹3,645 | 4,000 ₹3,645 | 6,000 ₹5,467.5 | 7,000 ₹6,378.75 |
| 5.00 | Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for foundation, laying of cables and getting out in soft/loose soil all as specified and as directed by Engr-In-Charge. | 533 | Cum | 100 ₹53,300 Lowest | 100 ₹53,300 Lowest | 130 ₹69,290 | 200 ₹1,06,600 | 800 ₹4,26,400 |
| 6.00 | M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
Note:- Measurement shall be taken after gentling puning of sand. | 111 | Cum | 400 ₹44,400 | 450 ₹49,950 | 380 ₹42,180 Lowest | 1,000 ₹1,11,000 | 1,200 ₹1,33,200 |
| 7.00 | Supply and laying PCC cable cover class HV type 1 flat size 300 mmx180mmx40mm complete all as specified and directed by Engineer-in-charge. | 3,164 | Each | 8 ₹25,312 Lowest | 15 ₹47,460 | 15 ₹47,460 | 15 ₹47,460 | 50 ₹1,58,200 |
| 8.00 | Supply and laying PCC cable cover class LV type 1 flat size 250mmx150mmx40mm complete all as specified and directed by Engineer-in-charge. | 7,933 | Each | 6 ₹47,598 Lowest | 10 ₹79,330 | 10 ₹79,330 | 20 ₹1,58,660 | 50 ₹3,96,650 |
| 9.00 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified. | 363 | Cum | 40 ₹14,520 | 30 ₹10,890 Lowest | 50 ₹18,150 | 50 ₹18,150 | 120 ₹43,560 |
| 10.00 | Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified. | 170 | Cum | 50 ₹8,500 | 30 ₹5,100 Lowest | 50 ₹8,500 | 50 ₹8,500 | 1,280 ₹2,17,600 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 Jul 2026, 6:00 pmClosed
Garrison Engineer (East) Mathura
Garrison Engineer (East) Mathura
REPAIR/MAINTENANCE AND IMPROVEMENT TO MAIN RECEIVING STATION AND CONNECTED FEEDER AND LT ELECTRICAL DISTRIBUTION SYSTEM IN THE AOR OF GE EAST MATHURA
2026_MES_768075_2
1584/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (E) Mathura
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (E) Mathura
₹90,000
Yes
5 Sept 2026
3 Jul 2026
27 Jul 2026
3 Jul 2026
25 Jul 2026
9 Jul 2026
3 Jul 2026 - 9 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating in trenches, n exc 1.5 m wide and more than 1.5 m n exc 3.0 m in depth; for foundation, laying of cables etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 3.0 m in depth and getting out complete all as specified and directed | - | Cum | - | - |
| 2 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr in Charge. | - | Cum | - | - |
| 3 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr in Charge. | - | Cum | - | - |
| 4 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping complete all as specified and directed by Engr in Charge. | - | Cum | - | - |
| 5 | Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for foundation, laying of cables and getting out in soft/loose soil all as specified and as directed by Engr-In-Charge. | 533 | Cum | - | - |
| 6 | M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
Note:- Measurement shall be taken after gentling puning of sand. | 111 | Cum | - | - |
| 7 | Supply and laying PCC cable cover class HV type 1 flat size 300 mmx180mmx40mm complete all as specified and directed by Engineer-in-charge. | 3,164 | Each | - | - |
| 8 | Supply and laying PCC cable cover class LV type 1 flat size 250mmx150mmx40mm complete all as specified and directed by Engineer-in-charge. | 7,933 | Each | - | - |
| 9 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified. | 363 | Cum | - | - |
| 10 | Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified. | - | Cum | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
BOQ_869406.xls
BOQ • 0.34 MB
Makelist.pdf
Additional Documents • 1.17 MB
Tender1584.pdf
Tender Documents • 3.10 MB
Amendment.pdf
PDF • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .