| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC | L1 | Accepted-AOC REASONABLE QUOTE | |
| 2 | L2₹29.0 L+₹2.3 L (8.50%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹29.7 L+₹3.0 L (11.2%)Rejected-Finance | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹30.2 L+₹3.5 L (13.0%)Rejected-Finance | L4 | Rejected-Finance NOT L1 |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
27 Aug 2020, 6:00 pmClosed
GE Jorhat
GE Jorhat
SPECIAL REPAIR TO BLDG NO.T-5 T-6 (ORS LIVING ACCN) OF CERTAIN UNIT AT BHALUKMARA IN JORHAT MILITARY STATION UNDER GE JORHAT
2020_MES_360988_1
8955/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE Jorhat
AS per NIT
4 documents required · 4 mandatory
₹500
GE Jorhat
₹59,000
Yes
29 May 2021
15 Jul 2020
28 Aug 2020
15 Jul 2020
27 Aug 2020
25 Jul 2020
15 Jul 2020 - 15 Jul 2020
Amount
Dismantling of Asbestos cement (corrugated, semi corrugated etc) sheets in roof covering complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as directed.
Dismantling old particle boards/plywood as in shelves boarding , any description, fixed in any position with nails if fixed with screws complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Demolition of cement concrete ( reinforced) in any postion and any description complete all as directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frame) n. exc. 1.5 Sq. M each, complete all as directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frame) exc. 1.5 Sq. M but not exc. 4.0 Sq M each, complete all as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil ,complete all as specified and directed.
Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all asspecified and directed.
Materials and Labour for reinforced cement concrete M-20 nominal mix in chajjas,complete all as specified and directed.
M&L for PCC (1:2:4) type B-I with using 20 mm graded aggregate as in benching, kerbs copings, edging of drain , hold fast etc including necessary form work wherever required all complete as specified and as directed.
Use and waste of form work to chullah hoods, chajjas,troughs and similar items including edges for fair finished surfaces of concrete, flat, complete all as specified and directed.
Material and Labour for Vitrified Ceramic Tiles, , 10 mm thick (square/rectangular) polished area of each tile not exceeding 0.36 Sq M, on floors, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match colour over and including 20 mm thick screed bed or bedding layer of cement mortar (1:6), complete all as specified and directed.
Material and Labour for Vitrified Ceramic Tiles,, 10 mm thick (square/rectangular) polished area of each tile not exceeding 0.36 Sq M, on vertical surfaces of wall such as dados, skirting etc., set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match colour over and including 15 mm thick screed bed or bedding layer of cement mortar (1:3), complete all as specified and directed.
Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in in cement mortar (1:4), complete all as specified and directed.
Material and Labour for pre-painted, galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self-tapping screws, complete all as specified and directed.Make(Tata bluescope/Sexena Marine Tech/Dyna )
Material and Labour for pre-painted, galvalume aluminium zinc coating GI based plain steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self-tapping screws, complete all as specified and directed.(Tata bluescope/Sexena Marine Tech /Dyna)
Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed
Supply and Fix, pressed steel frames, size 125 x 60mm, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified and directed.
Supply and Fix, pressed steel frames, size 105 x 60mm, for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified and directed.
Supply and fix Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and directed.
Supply and fix Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
Supply and Fix,steel ventilator with top hung shutter including hinges, steel peg stay, complete with glazing bars, dovetailed or welded, including taking down existing unserviceable one including making good disturbed surfaces as per existing specfication complete all as specified and directed.
Supply and Fix, factory made wire gauzed PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded prelam PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
Supply and Fix, 35 mm thick, Factory made flush shutters, solid core construction, with particle board core and plywood face panels,both faces is covered with decorative face veneer with lipping/frame to match, complete all as specified and directed.
Supply and fix Aluminium anodized barrel tower bolts of extruded section, 150 mm long complete all as specified and directed.
Supply and Fix, aluminium handles, cast type, anodized, 150 mm size, complete all as specified and directed.
Supply and Fix, aluminium handles, Fabricated type, anodized, 150 mm size, complete all as specified and directed.
Supply and Fix,4 mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sq M in each pane complete all as specified and directed.
S & F for 4.0mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq m in each pane complete all as specified and directed.
Supply and Fix, Aluminium Alloy, anodised, sliding door bolt, length of bolt 300 mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
Supply and Fix, floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring and with overall length of cover plate 150 mm, fixed in floor, complete all as specified and directed.
S & F in repair 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
Materials and Labour for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Grade E-165 complete all as specified and directed.
Supply and Fix, stainless steel wire cloth, 0.36mm nominal dia. of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
M&L providing and fixing of false ceiling with powder coated exposed GI grid suspension system (E-grid T-2420 or equivalent of Armstrong having load carrying capacity of 12.5 Kg/M3 with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200/600 mm long and Wall Angle. The wall angle shall be fixed on PVC dash fasteners on the perimeter of the wall with steel screws with distance 300 mm c/c. The main runners to be placed @ 1200 mm, the cross tee 1200 mm will be inserted in the pre-cut slots of Main Runner at regular interval of 600 mm to form a modular grid of 1200x600mm. Additional cross tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm x 600 mm with and including 6 mm thick HSPC (High pressure steam cured) oceanic pre primed, self embossed, textured designer board, water, termite & fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 2 to 3 mm dia or as per manufacturer,s instructions GI bar hangers fixed with steel dash through fasteners from purlins with butterfly clips (wt 0.007 kg/clip), hold down clips (wt-0.0035 Kg/clip), with provn of light fixture complete all as per manufacturer instructions and as directed. Make Armstrong or equivalent make
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
Material and Labour for applying two coats of synthetic enamel paint over a coat of pink primer on new wood or wood based surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface other than fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on other than fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - (Water proofing compound will be deemed to be included quoated rates)
M&L for preparation of new plastered or un -plastered from walls, and applying two coats acrylic distemper on walls, over and including a coat of 3mm thick white wall care putty over a coat of primer complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M&L for complete removal of existing treatment from walls/ceiling, and applying two coats acrylic distemper on walls/celing, over and including a coat of 2 mm thick white wall care putty with and including a coat of primer complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
Material and Labour for applying two coats of cement-based paint, white or tinted to new plastered surfaces on walls including priming with alkali resistant priming paint and including preparation of surfaces complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Taking down copper/aluminium sub main wiring complete and removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for concealed type wiring using approved colour coding as per IS for one light/ fan/ bell point controlled by one switch with1.5 Sqmm (Nominal area) PVC insulated, unsheathed, multistranded copper, conductor cable FRLSH (1100Volts grade) drawn in and including heavy duty PVC rigid conduits of 20/25 mm dia with all fittings and accessories alongwith PVC insulated multi stranded copper conductor of size 1.5 Sqmm as earth continuity conductor including fixing of 1. 22mm thick MS sunk terminal box duly flushed to wall with 3mm thick plastic laminated/ebonite sheet cover fixed with brass screws,cap and washers complete all as specified and as directed. Note:- (i) The chases in the wall shall be cut with elect cutter (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge
All as per item No- 49 as above but for one 3/5 pin socket outlet 5 Amps on the same board with other switches.
All as per item No- 49 here-in-before but for switch socket combination 5 Amps 2/3/5 Pin point on independent board.
M&L for concealed type wiring using approved colour coding as per IS for switch socket combination 15 amps 5/6 Pin point on Independent board with 4 Sqmm (Nominal area) PVC insulated, unsheathed, multistranded copper, conductor cable FRLSH (1100Volts grade) drawn in and including heavy duty PVC rigid conduits of 20/25 mm dia with all fittings and accessories alongwith PVC insulated multi stranded copper conductor of size 2.5 Sqmm as earth continuity conductor including fixing of 1. 22mm thick MS sunk terminal box duly flushed to wall with 3mm thick plastic laminated/ebonite sheet cover fixed with brass screws,cap and washers complete all as specified and as directed. Note:- (i) The chases in the wall shall be cut with elect cutter (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge
M & L wiring for circuit/Sub main wiring concealed type with two single core cable PVC insulated cable with 6.00 Sqmm (Nominal area) multi stranded copper conductor FRLSH cable 1100 volts grade including earth continuity conductor using PVC insulated cable of stranded copper conductor of size 4 Sqmm connected to common earth dolly and drawing into and including steel conduits of size 20/25 mm dia medium grade including making good the disturbed surfaces to match with existing surfaces complete all as specified and as directed. Note:- (i) The chases in the wall shall be cut with elect cutter (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge
Supply and Fix, switch piano, flush button, single pole, one way, 5 Amps, complete all as specified and directed.
Supply and Fix, switch piano, flush button, single pole, one way, 15 Amps, complete all as specified and directed.
S & F Socket outlet, 2 in 1, 3 pin, 5 Amp complete all as specified and directed.
S & F Socket outlet, 2 in 1, 3 pin, 15 Amp complete all as specified and directed.
Supply and Fix, ceiling rose, three terminal, PVC/ Polycarbonate insulated body, complete all as specified and directed.
Supply and Fix stepped type electronic fan regulator, flush type, on existing phenolic laminated sheet etc. as required , complete all as specified and directed.
Supply and laying common burnt clay building bricks, sub-class ‘B’ designation 75, old size bricks, in cable trenches, as cable protection, complete all as specified and directed.
Supply and filling in approved dry sand in cable trenches before and after the cables are laid, as in sand cushioning to cables, complete all as specified and directed.
Supply,laying, jointing and testing of LT, XLPE insulated, PVC sheathed, armoured, heavy duty electric cables with aluminium conductor for working voltage up to and including 1100 volts, of cross sectional area 35 sq. mm, 4 core, including with suitable size of lugs including taking out existing one complete all as specified and directed.
Supply and Fix lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings,complete all as specified and directed.
Supply and Fix, LED lamp, 15 Watts, lumen output 770 lm, colour temp 6500 K, lamp current 0.04 amp, lamp base cap B22, complete all as specified and directed.
S&F Decorative ultra slim linear LED lighting fixture with co extruded polycarbonate body environmental friendly, E-lite LED GREEN 20W, 240 Volt, LED tube light as per Havells Cat No. LUMILINEBS20WLED865SPCWH or equivalent of philips/Bajaj/wipro and including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 Sq mm, 3 core, 1100 Volts grade, from light fitting to point outlet, complete all as specified and directed.
Supply and Fix, LED roadway luminaire, 25 Watts, with pressure die-cast aluminium housing,IP-66, high power LEDs as light source and electronic driver, all as per Cat No. LR02-291-XXX-57-XX of Make ‘Wipro’ or Equivalent Model of Make Havells/Bajaj/Philips and including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.75 Sq mm, 3 core, 1100 Volts grade, from light fitting to point outlet, complete all as specified and directed.
Supply and Fix, Heavy Duty Exhaust Fan with self closing metallic louvers, 380 mm sweep, 1400 RPM, Single Phase, 230 V, 50 Hz, Make ‘Havells’ or equivalent Model of Make ‘Usha’ / ’Crompton Greaves’/’Almonard’ and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 1.50 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan complete all as specified and directed.Note: Cost of cutting and making hole for fixing exhaust fan shall be deemed to included in quoated rates
Supply and Fix, double door, sheet metal enclosure for DBs for mounting of MCB for 415 Volts, 4 way, with 200 Amps rated bus bar, Triple Pole & Neutral, with and including taking down unserviceable one complete all as specified and directed. [Cat No.DBTPN004DD of Make L&T or equivalent Model of Make Legrand/Siemens]
Supply and Fix, miniature circuit breaker (MCBs) three pole and neutral, 415 Volts, 10KA, 63 Amps "C" series complete all as specified and directed.
Supply and Fix, miniature circuit breaker (MCBs), single pole and neutral, 240 Volts,10KA, 40 Amps "C" series complete all as specified and directed.
Supply and Fix, double door, sheet metal enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 200 Amps rated bus bar, Single Pole & Neutral, , including dismantling taking down unserv. DB complete all as specified and directed Cat No.DBSPN008DD of Make L&T or equivalent Model of Make Legrand/Siemens]
Supply and Fix, miniature circuit breaker (MCBs), DP, 240 Volts,10KA, 40 Amps C curve complete all as specified and directed.
Supply and Fix, miniature circuit breaker (MCBs), single pole, 240 Volts,10KA, 6-32 Amps "C" series complete all as specified and directed.
Taking out existing unserviceable armoured electric cables,1100 volts,cross sectional area 35 sq. mm, 3 ½ core from trenches/ducts/poles etc.,complete all as directed.
Supply and Hanging, ceiling fan, rating 240 V, 50 Hz, Single Phase, 1200 mm sweep with down rod, canopy, fan blades and accessories, BEE 5 Star Rated, all as per Model “Usha Energia 32 5 star ” of Make ‘USHA’ or equivalent Model of Make ‘Havells’/’Crompton Greaves’/’Almonard’ , and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan complete all as specified and directed.
Supplying, installing, testing & commissioning, storage water heater (geyser), 50 litres capacity, standing loss less than 0.562 Kwh per day for 45⁰C difference of temperature as per IS 2082 (five-star rated as per BEE), reheating time less than 60 minutes, mixing factor less than 20%, shock proof high density PUF insulation body material, glass lined inner tank material having warranty 7 years on tank material, 4 years on heating element and 2 years on other spares parts comprising following fittings (a) glass coated incoloy element (b) capillary type thermostat (c) digital display unit (d) thermal cutout (e) multifunction valve (f) earth leakage circuit breaker (g) magnesium anode rod cathodic protection (h) flexible cable of suitable length with 3-pin plug of 16A capacity (i) drain plug (j) fusible plug fitted on the crown of water heater with operating temperature between 100⁰C to 110⁰C including fixing by grouting and fastener complete all as specified and as directed.
Materials and Labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanised steel earth lead wire 4 mm dia. by means of bolts, nuts check nuts and washers of galvanised steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009)
MS J B CONSTRUCTION AND CO
M/S GOPAL ROY AND CO
Eastern Transort Agency
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .