Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹26.5 L+₹82,900 (3.23%)Rejected-Finance 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L2 | Rejected-Finance BEING NOT L1 BIDDER | |
| 3 | L3₹29.1 L+₹3.4 L (13.1%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L3 | Rejected-Finance BEING NOT L1 BIDDER | |
| 4 | L4₹30.4 L+₹4.8 L (18.5%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 BIDDER | |
| 5 | L5₹30.6 L+₹4.9 L (19.1%)Rejected-Finance 138A STANLEY PARK OTTUPATTARAI POST COONOOR 643 105 THE NILGIRIS TAMIL NADU | THE NILGIRIS | TAMIL NADU | 643105 | L5 | Rejected-Finance BEING NOT L1 BIDDER |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
5 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DSSC WELLINGTON
GE DSSC WELLINGTON BARRACKS-POST, WELLINGTON, THE NILGIRIS, TAMIL NADU,PIN-643231
MAINT REPAIRS TO LT DISTRIBUTION SYSTEM AND INCL ALLIED WORKS UNDER GE DSSC WELLINGTON
2022_MES_568218_1
8289/E8
Open Tender
Civil Works
Item Rate
270 days
WELLINGTON
PLEASE REFER TENDER DOCUMENTS AND NIT
8 documents required · 8 mandatory
₹500
GE DSSC WELLINGTON
₹59,000
Yes
17 Feb 2023
9 Dec 2022
7 Jan 2023
9 Dec 2022
5 Jan 2023
23 Dec 2022
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for taking out/laying of UG Cables, GI Pipe etc. and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick with excavated soil complete all as specified and as directed.
Removing of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
M & L for providing sand cushioning for protection of UG cable in trenches with Coarse River Sand/ Riddled Earth of approved quality as approved in writing by GE including filling, spreading and punning down to desired thickness complete all as specified and as directed. Note : Punned thickness only will be measured and paid separately.
Supply and laying sub class "B" bricks in trenches for protection of UG Cable with width equal to length of bricks, laid dry & flat complete all as specified and as directed.
Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2.0 core in trenches through GI pipe and fixed with pole structure or in LT Panel MCCB any size and any type with lugs & connecting accessories incl taking down old cable complete all as specified & as directed. Make for Sl Item Nos 6 to 15: HAVELLS/GLOSTER/POLYCAB/ FINOLEX/ KEI. Note :- Necessary earthwotk, PCC etc shall be measured & Paid separately under relevant items of works
Description all as per Item Sl No 6 here in above but of size 10 Sqmm 4.0 core complete all as specified and as directed.
Description all as per Item Sl No 6 here in above but of size 16 Sqmm 4.0 core complete all as specified and as directed.
Description all as per Item Sl No 6 here in above but of size 25 Sqmm 4.0 core complete all as specified and as directed.
Description all as per Item Sl No 6 here in above but of size 35 Sqmm 3.5 core complete all as specified and as directed.
Description all as per Item Sl No 6 here in above but of size 50 Sqmm 3.5 core complete all as specified and as directed.
Description all as per Item Sl No 6 here in above but of size 70 Sqmm 3.5 core complete all as specified and as directed.
Description all as per Item Sl No 6 here in above but of size 95 Sqmm 3.5 core complete all as specified and as directed.
Description all as per Item Sl No 6 here in above but of size 120 Sqmm 3.5 core complete all as specified and as directed.
Description all as per Item Sl No 6 here in above but of size 150 Sqmm 3.5 core complete all as specified and as directed.
M & L for boring under road manually with labour suitable for inserting upto 100 mm bore pipe at a depth 0.75 to 1.0 mtr complete all as specified and as directed.
M & L for cutting the existing hardstanding /PCC/ WBM road at a depth of not less than 60 cm & 30 cm in width for passing of HT/ LT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed.
Note for Item Nos 1, 16 & 17 : Any damages made to the existing services of MES/WCB/TNEB/Other Depts like HT/LT UG cables, Water Supply/Sewage Pipe lines, OFC/BSNL/ITRC/Signal communication cables etc. during the excavation/boring/road cuting etc. progress of the work shall be made good with proper jointing kits etc. as per original to the entire satisfaction of Engr-in-Charge & GE & the cost of the same is deemed to be included in the unit quoted rates. Decision of the AO shall be final & binding in this matter.
M & L for GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 80 mm complete all as specified and directed. Make : Tata /Jindal /Prakash. Note : Wherever GI Protection pipes are to be placed/fitted above earths surface, cost of necessary clamping /fixing arrangements to the entire satisfaction of Engr-in-Charge is deemed to be included in the unit quoted rates.
Description all as per Item Sl No 18 here in above but of bore 50 mm complete all as specified and as directed.
M & L for cutting grass, bushes, creapers, weeds, unwanted plants /growths, area cleaning etc in and arround Electric Supply Installations, LT Panels, Feeder Pillar Boxes or any other locations as decided by Engr-In-Charge/GE and removing rubbish off the premises complete all as specified and to the entire satisfaction of the Engr-in-Charge. Note : Any damages made to the existing services of MES/WCB/TNEB/Other Depts like HT/LT UG cables, Water Supply/Sewage Pipe lines, OFC/BSNL/ITRC/Signal communication cables etc. during the progress of the work shall be made good with proper jointing kits etc. as per original to the entire satisfaction of Engr-in-Charge & GE & the cost of the same is deemed to be included in the unit quoted rates. Decision of the Accepting Officer shall be final and binding.
M & L for preparation of old painted steel surfaces of outdoor/indoor type LT/HT Panels, Feeder Pillar/Junction boxes, Change-over Boxes etc. of any size/type etc. after cleaning of oils, wax, lubricants, grease, rusty scales, spider webs, dusts etc. complete & applying one coat of synthetic enamel paint of approved colour & grade using spray gun & neatly writing distribution details (if applicable) complete all as specified & as directed by the Engr-in-Charge.
M & L for preparation of old painted steel surfaces of LT/HT/Security/Street light steel tubular poles incl MS Clamps, cross arms, GI Pipe brackets etc. of any size/type etc. after cleaning/removal of oils, wax, lubricants, grease, rusty scales, spider webs, dusts etc. & applying one coat of Aluminium paint & neatly writing pole numbers complete all as specified and as directed.
M & L for straight through joint, heat shrink type for LT UG Cable incl joint kits suitable for Aluminium conductor cable of size 25 to 50 Sqmm 4/3.5 core incl earthwork, taking down, preparation of damaged cable including testing complete all as specified and as directed. Make: Denson /3M /Yamuna /Raychem.
Description all as per Item Sl No 23 here in above but suitable for Aluminium conductor cable of size 70 to 150 Sqmm 3.5 core complete all as specified and as directed.
Description all as per Item Sl No 23 here in above but suitable for Aluminium conductor cable of size 185 to 300 Sqmm 3.5 core complete all as specified and as directed.
S & F in repairs copper cable lugs for the following sizes after removing the old /burnt out cable lugs of cable from MCCBs /Changeover /Transformer LT bushing and connecting back cables in MCCBs/Changeover /Transformer LT bushing for 16 Sqmm to 25 Sqmm complete all as specified and as directed.
Description all as per Item Sl No 26 here in above but 35 Sqmm to 50 Sqmm complete all as specified and as directed.
Description all as per Item Sl No 26 here in above but 70 Sqmm to 95 Sqmm complete all as specified and as directed.
Description all as per Item Sl No 26 here in above but 120 Sqmm to 185 Sqmm complete all as specified and as directed.
Description all as per Item Sl No 26 here in above but 240 Sqmm to 300 Sqmm complete all as specified and as directed.
S & F 4 pole Power Contactors MCX 31/32 AC-1 aux contacts (2 No + 2 NC) Rating Fr 4 Cat No CS97020 setting and making cut in existing panel complete all as specified and directed by the Engr-in-Charge. Make: L&T /Havells /Legand or techno-commercially equiv in ABB/Siemens
S & F MCCB , 4 pole,63A rating (Ics = 100% Icu), 415Volts, 25 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed by the Engr-in-Charge. Make: L&T/Havells/Legrand or techno-commercially equiv in ABB/Siemens
S & F MCCB, 4 pole,100A rating (Ics = 100% Icu), 415Volts, 36 KA Breaking capacity, with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed by the Engr-in-Charge. Make: L&T /Havells/Legrand or techno-commercially equiv in ABB/Siemens
S & F MCCB, 4 pole,160A rating (Ics = 100% Icu), 415Volts, 36 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed by the Engr-in-Charge. Make: L&T/Havells/Legrand or techno-commercially equiv in ABB/Siemens
S & F MCCB, 4 pole,250A rating (Ics = 100% Icu), 415Volts, 36 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed by the Engr-in-Charge. Make: L&T/Havells/Legrand or techno-commercially equiv in ABB/Siemens
S & F MCCB, 4 pole,400A rating (Ics = 100% Icu), 415Volts, 36 KA Breaking capacity,with adjustable thermal and fixed magnetic setting and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specifiedd and directed by the Engr-in-Charge. Make: L&T/Havells/Legrand or techno-commercially equiv in ABB/Siemens
M & L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc., all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.
Note : On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory.
S & F SPN DB 02 Way IP 43 sheet metal enclosures DBs and making good the disturbed surfaces will all other acessories including all connecting items all as specified and directed by Engr-in-Charge. Make : L& T/Havells/Legrand
S & F MCB SPN C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KAS all specified and directed by Engr-in-Charge. Make : L& T/Havells/Legrand
Supply, install, testing & commissioning of LT busbar junction box "out-door type" of size 750 mm (height) x 600 mm (breadth) x 300 mm (depth) (minimum dimensions), factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The box shall be provided with ventilation facility in the form of louvers for better heat dissipation & high grade aluminum bus-bar of rating 400A of length 600mm, min spacing of 80mm between the busbars & wrapped with coloured PVC tape /sleeves of rating in conformity to the Incoming cable rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.00 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Phase, 4 wire system 415 /440 volts grade including I/C & O/G cable opening on bottom & at both sides including cable glands of suitable sizes with suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) incl taking down old unsv box of any size/type complete all as specified & as directed.
Notes :- (i) Design / drawing / BOM of the Panel Board showing the dimensions is to be obtained from the Manufacturer / Supplier & is to be got approved from the Engr-in-Charge & GE before placing final order to the manufacturer. (ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
M & L for repairs to feeder pillar box/LT panel etc, taking out old unserviceable and fixing of new hinges (if any) by welding/bolt nuts,addn/altn to MCCB enclosure cover with one incoming and No of out goings by grinding,cutting and painting all as shown and diretced, repairs to door lock by replacing unsv locks, extension of aluminium bus bars for incoming/outgoing MCCBs as per existing shapes and size, spray painting with two coats of approved grade & color synthetic enamel paint after scrapping incl preparation of old painted surfaces & fixing 02 nos (front & back) danger notice plate as per standard size complete all as specified and directed.
Supply, install, testing & commissioning of on load change over switch 4 pole (I-O-II) in sheet mental enclosure modular construction type, confirming to IS/IEC 60947-3, rated current 200 A, 415 V, with supporting angle iron frame , PCC (1:3:6) type C2 foundation necessary earth work (if any) incl taking down and all as specified and directed by Engr-Charge. Make : L & T, Cat No : CO22000OSOO or equivalent of ABB/SIEMENS.
Description all as per Item Sl No 42 here in above but suitable for Aluminium conductor cable of size 160 Amp complete all as specified and as directed. Make : L & T, Cat No : CO21600OSOO or equivalent of ABB/ SIEMENS
rvelectricals
Sreekrupa Enterprises
Saket Enterprises
Shree Jayam Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .