Repair / maintenance of outgoing 1000 AMP LT control Panel unit 3 and unit no 5 and repair servicing to vacuum circuit breaker of 2.5MVA power transformer unit no 01 and unit no 02 and HT control panel 01 and 02 installed at Lift Irrigation Station R
2024_IFC_269186_1
ENIT 52
Open Tender
Electrical and Maintenance Works
Item Wise
15 days
Executive Engineer mechanical division RTIC Jammu
Please refer Tender documents.
8 documents required · 8 mandatory
₹200
Executive Engineer mechanical division RTIC Jammu
₹3,000
Yes
Executive Engineer mechanical division RTIC Jammu
21 Feb 2025
30 Dec 2024
14 Jan 2025
31 Dec 2024
13 Jan 2025
31 Dec 2024
31 Dec 2024
Amount
Repair / maintenance of 1000 amp. Control Panel Air circuit breaker system installed in unit No-3 circuited with 4000AMP Control Panel (unit no-1) and LT control panel air circuit breaker system installed in unit no 5 circuited with 4000AMP Control Panel (unit no-2) Dismantling/extracting of air circuit breaker system of 1000 amp. LT. control panel. Dismantling of Conductors, Bus Bar, Switches, voltage relay, and thermal magnetic relay, single phase preventer, HRC fuses indicator, amp meter and voltmeter and damaged wiring. Reconditioning / Repairs of damaged conductor accessories like terminal connection closing coil, overload indicator, shunt coil, under voltage coil overload relay, Bus bar strip and other allied spares required to be replaced. Job includes proper insulation of the new provided wiring system and complete servicing of 1000 amp. ACB at site and reassembling the same and testing on full load.
Repair/servicing to Vacuum Circuit Breakers of 2.5 MVA power transformer unit 01 and unit 02 by way of its dismantling and extracting out the damaged/burnt tripping coil and HRC fuses of unit no 01 and 02. Providing and fitting of new tripping coil closing coil, closing push buttons and HRC fuses of suitable capacity. Replacement of Anti-pumping relay 36 volt in place of worn-out/damaged one of reputed make as per IS Standard in unit no 1 and 2. Complete painting of both the VCB by way of cleaning the outer surface of VCB using emery paper, wire brush and scratching of old paint to remove rust, dust etc. to make surface ready for painting and then applying two coats of superior quality paint .Job includes complete servicing of Vacuum Circuit Breaker of unit no 01 and unit 02 including cost of material. Labour charges, testing and commissioning at site
Repair / servicing of HT control panel unit no. 1 by way of replacement of one no numerical Relay (MIT Relay) in place of damaged one for over current and earth fault relay and complete checking / servicing of HT control panel 01 and 02 by way of checking of ammeter, Voltmeter, power factor meters, MVAR meters and MW meters, semaphores Auxiliary relay for buchholz, alarm and trip including control cables from yard to control room. Replacement of control switches, indicator lamps. Job includes cost of material and labour charges and charges for all tools and tackles required for execution of jobs at site.
PERFECT ELECTRICAL WORKS (BID ID -2308951)
N B Engineering and Electric Works (BID ID -2309390)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .