Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC 1 6 MOITRI SARANI RABINDRA NAGAR KOLKATA 700 065 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700065 | ₹2.0 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹2.0 Cr+₹4.6 L (2.36%)Rejected-Finance 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | ₹2.0 Cr+₹4.6 L (2.36%) | L2 | Rejected-Finance HIGHEST |
| 3 | L3₹3.4 Cr+₹1.5 Cr (75.8%)Rejected-Finance | ₹3.4 Cr+₹1.5 Cr (75.8%) | L3 | Rejected-Finance HIGHEST |
Tender Value
Refer Docs
EMD Value
₹3.0 L
Closing Date
10 Dec 2021, 2:00 pmClosed
Superintending Engineer PWD Electrical
Superintending Engineer PWD North Bengal Electrical Circle P.W.D Inspection Bungalow Annex Building 1ST Floor Kutchery Road Venus More Siliguri
Construction of proposed Damanpur Polytechnic at Alipurduar District E.I work incl. S.I.T.C of Sub station work D.G set Lightning arrester etc.
2021_WBPWD_350434_1
WBPWD/SENBEC/NIT-34/2021-2022
Open Tender
ELECTRICAL WORKS ORG
Item Rate
120 days
Damanpur Polytechnic at Alipurduar
Please refer Tender documents.
6 documents required · 6 mandatory
₹3.0 L
Siliguri
8 Feb 2022
12 Nov 2021
13 Dec 2021
12 Nov 2021
10 Dec 2021
25 Nov 2021
23 Nov 2021
Amount
SUB-HEAD 1 -FIXING OF LIGHT FITTINGS
Fixing only pendent light fitting complete with lamp, shade and 24/0.2 mm (1.5 sqmm) flexible copper wire incl. S&F pendent holder
Fixing only bulk head ceiling fitting on wall /ceiling by screws etc as per GS.
Fixing only single/twin florescent light fitting complete with allaccessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required
Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit as per GS
SUB-HEAD 2 - SUPPLY OF LIGHT FITTINGS
[All LED Fittings must be Five years warranty ]
Supply & Delivery Single LED Fittings With LED tube ( Philips Make, Cat No.TMC 501 P 1xT-LED 22W P3241 incl. 1x MAS LED (PC body) tube 1200mm 18W865 T8 I--2100lm. Or Equivalent product of Crompton/Wipro having similar specification in all respect)
Supply & Delivery double LED Fittings with LED tube ( Philips Make, Cat No.TMC 501 P 2xT-LED 22W P3242 incl. 2x MAS LED (PC body) tube 1200mm 18W865 T8 I--2100lm Or Equivalent product of Crompton/Wipro having similar specification in all respect)
supply and fixing of 9 watt, 240 V, LED Lamp (Philips/CG/ Syska)
Supply & Delivery surface mounted LED down light ( Philips make - CIRRUS MINI/CG/Bajaj ) Connection.SM 200C LED 11S 6500 PSU OD WH
SUB-HEAD 3 -- FIXING OF FANS
Fixing only ceiling fan complete with blades, canopy, fork, rubberbush etc. incl. S&F connecting wire for down rod upto 30 cm incl.painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
SUB-HEAD 4 -- SUPPLY OF FANS
Supply & Delivery of 1200 mm sweep as per IS 374:1979 complete with all accessories including S2(P2) type capacitor as per IEC 60252-1 with upto date amendents, and with safety wires for secondary suspension of fans complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [Make-Crompton/Usha/Orient]
Supply & Delivery of 1400 mm sweep as per IS 374:1979 complete with all accessories including S2(P2) type capacitor as per IEC 60252-1 with upto date amendents, and with safety wires for secondary suspension of fans complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [Make-Crompton/Usha/Orient]
SUB-HEAD 5 -- MISCELENEOUS
Supplying & Fixing 240 V AC superior type Gong Bell (Anchor) as per GS
Supplying and fixing 415V, 63A TPN SFU with sheet steel enclosure on angle iron on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse. [Make:- L&T/Siemens]
SUB-HEAD 6 -- EARTHING
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50mmx25 mm x 6 mm on wall as per GS
SUBhead-7.1 SITC OF CUBICLE TYPE LT PANEL( LIGHT PANEL-1 &2)
SITC of of LT, Cubicle Type, Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz, as per size, design & drawing to be approved by EIC. The panel board will be fabricated by CPRI approved panel maker as per detail specification below. ( uploaded in the specification section) and following switches. I/C-250A MCCB-01 Nos, O/G- 160A, MCCB-06 Nos, 63A MCCB-02 Nos
SITC of of LT, Cubicle Type, Floor Mounted , totally enclosed, fully compertmentalized electrical control panel suitable for operation at 415 Volt, 50 Hz, as per size, design & drawing to be approved by EIC. The panel board will be fabricated by CPRI approved panel maker as per detail specification below. ( uploaded in the specification section) and following switches. I/C-315A MCCB, O/G-200A, MCCB-04 Nos, 160A, MCCB-02 Nos, 63A MCCB-01 Nos
SUB-HEAD 10 -- SITC OF LIGHTNING PROTECTION SYSTEM-I)
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet / Roof / Wall with GI Saddles1100 mm apart incl. mending good the damages to building works
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart including mending good damages to building work
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS [ For Soft Soil ]
Earthing with 50 mm dia GI pipe ( Tata Medium ) 3.64 mm thick x 3.04 Mts long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.
Extra for providing masonery enclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CIhinged inspection cover of size 36.56 cm x 35.56 cm withlocking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate / pipe electrode .
Providing and laying G.I. tape / strip 32 mm X 6 mm from earth electrode directly in ground as required.
SUB HEAD 11: SITC OF DG SET(J)
SITC of 3Ø Silent Type Diesel Generating Set having Prime power Rating of 200 KVA at 415V, 50Hz, 0.8 lagging Power Factor on the existing foundation comprising of Engine, alternator, AMF panel, Base frame, Fuel tank, Battery, Acoustic Enclosure and other accessories as per attached details specification
SITC of Air Circuit Breaker, Horizontal Manual Draw Out type, 4 pole, 630 Amps, 415 volts, Icu@415V=Ics=Icw for 1 sec = 50kA rating manually operated with interlocked doors, automatic safety shutters, mechanical ON / OFF and service / test / isolated position indicators and frame earthing contact, with microprocessor release for overcurrent, earth fault and short circuit protection, 1 no. independent manual spring closing mechanism, conforming to IS 13947 - 2 - 1993,1 no. shunt trip coil 220 Volts AC, in sheet steel enclosure with suitable arrangement for fixing.
Providing cement concrete foundation for the DG set with 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size)[M20 grade ] including excavation, providing base concrete with 1:5:10 cement concrete, required centering/ shuttering, finishing the exposed portion etc. as reqd. ( Item will be paid based on measurements for 1:2:4 CC, but excluding the 1 : 5: 10 leveling course of base concrete) as per direction of E-in-Charge and manufacturer recommendation.
Supplying and fixing exhaust gas piping (115MM Diameter ). welded black MS, B class pipe conforming to IS: 3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50 mm thick wiremesh and aluminium cladding etc., as per requiremement of pollution control norms and required as per direction of Engineer-in-Charge and manufacturer recomendation.
Fabrication and fixing of MS angle ladder type structure fabricated out of 50mm x 50mm x 6mm angle iron for support of exhaust gas pipe of existing DG set to the required height including grouting in 1:3:6 (1 cement : 3 graded stonenaggregate: 6 coarse sand) cement concrete in ground and support on building, welding, grinding, painting etc. as required. (The measurement shall be made in running meter of MS angle iron only and converted to weight in Kg)
Supply, Delivery including transportation of HSD Oil
Supply, Delivery including transportation of Mobil Oil
S & Delivery of 200 Ltr. Capacity Container made of heavy guage M.S. Sheet container.
S & Delivery of best quality oil hand pump with 1” dia PVC flexible pipe (12’ ft. approx)
SUB-HEAD 12- SITC OF STREET LIGHTING SYSTEM(B)
Supply & Delivery of Hot Dip Galvanised (as per IS:2629 / IS 2633 / IS 4759 and with its latest amendment ) Octagonal Pole made of HT steel ( sheet thickness -3mm ) conforming to grade S355 of BSEN 10025 alongwith welded base plate of required size conforming to IS: 226 / 2062 with integrated Control box with required sizes studs for termination of 2 core 10 /4 Core 16 sq mm Al (Armoured ) cable incld S&F 1 No 6 Amp SP MCB ( C-Series ) for each out going circuit to the fittings with proper pad locking arrangement for the following pole -- 7 Mtr Long [ Top Dia ( A / F ) - 70 mm, Bottom Dia ( A / F ) -130 mm ] Base Plate Size : 200 mm x 200mm x 12 mm.. ( Make : Bajaj, Philips, Valmont, CG, Transrail/Bansal ).
Errection of the following Octagonal pole by designing and Casting RCC ( M 20 ) foundation of suitable size as specified below considering the safe soil bearing capacity at site as T/sq m, including excavation of earth, providing, cutting, bending and placing in position reinforcement as per drawing and providing pipe for cable entry and exit as required and providing and fixing of 4 Nos foundation bolts ( J Type ) as specified below and as per drawing on ground surface including back filling and cleaning extra earth -7 Mtr Long [ Foundation size - 500 mm X 500 mm X 1200 mm, J Bolt Size - M 20 X 600 ]
SITC of single arm hot dip galvanized steel overhang bracket ( Swan Neck Type ) at the top of the pole having 1 M length complete with all fixing arrangements as required including painting (a) Single Arm
SITC of road lighting luminaire ( IP 65 ) with peanut lens and high power LED and to ensure uniform distribution, higher spacing between poles and maintenance free system andsystem lumen output will be 7000 lumen suitable for use with 230Volt 50Hz AC supply etc as required. ( Make - Philips Model No. BRP 410 ) or equivalent product of Crompton/Wipro having similar specification in all respect.
SITC of Gate lighting luminaire with IP 65 Crompton Make, Cat. No.LPT0-40-WW Or Equivalent product of Philips/Wipro having similar specification in all respect.
Supply & Delivery 1.1 KV Grade 2 core 10 Sq.mm XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable and conforming to IS: 7098(Part-I):1988/1554(Part-I):1988/ 5831:1984/ 3961(Part-I):1967/ 3975:1970/ 10810:1984/ 3975:1970 /8130:1984/ 3961:1967/ 10418:1982/10810:1984 as amended upto date, in respect of component materials and tests. [Nicco / Gloster/Polycab/Havells/RR Kable]
Laying of one No. 2 Core 10 Sq.mm cable in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :2 Core10 Sq. mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :(a) 2 Core10 Sq. mm
S & L of 1.1 KV grade 3 X 1.5 Sq mm FR single core multi stranded copper wire for connection from loop box to fittings through 13 mm dia polythene pipe
Finishing of the PVC insulated wire(3 X 1.5sqmm) ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
S & F of medium gauge G.I pipe (ISI medium) having the following diameter [32 mm Diameter] for protection of cable with necessary fitting and jointing materials as required.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as below (ISI medium G.I pipe)
SUB HEAD 13: SITC OF 11KV VCB PANEL & TRANSFORMERS(C)
Supply & Delivery Indoor-type, floor mounted,metal clad, single tier, fully compartmentalized,free standing, 11 kV VCB Panel with 3 Nos VCBs (1 Incomer + 2 Outgoing), totally enclosed and fully interlocked , horizontal drawout, horizontal / vertical isolation type breaker as per IS 13188, as ammended upto date and as per detail specification attached ( uploaded in the specification section) , suitable for use on 11 KV, 3 Phase,50 Hz AC supply to energise 2 X200 KVA Dry Type Transformers. [ Make : ABB / Siemens / CGL].
Installation & commissioning of the above 11 kV VCB Panel with P.T & all the accessories, incl. carriage, by placing in position, assembling, lining up, levelling and checking all instruments, relays, correctly set according to requirement.
11KV / 415V, DRY TYPE TRANSFORMER
Supply & Delivery of Cast Resin Dry Type 11KV / 415V, 200KVA, 3 Phase, 50Hz, Dyn11,copper wound , Class F insulation associated with winding temparature indicator/Controller, having cable end box in the HV 7LV sides and all accessories and confirming to IS 11171-1985 & IS - 2026 with latest modification (if any) & CBIP Specification as per detail specification attach(Uploaded in the Specification in the Specification section [ Make: ABB/Voltamp ( Varoda)/CGL].
Installation & commissioning of 11 KV/ 415 volt, 200 KVA distribution transformer incl. carriage to the substation building within a lead of 30mtr by placing in position and fixing after leveling fitting all components, connecting, checking & set of all instrument, relays according to requirement as instructed by the EIC incl. S&F base channels etc.
Making testing arrangement and submitting the test report for high voltage testing of specified voltage incl. checking & testing of all HT / LT equipments by authorized firm of Directorate of Electricity & commissioning the installation after obtaining the Approval of Directorate of Electricity.The scope shall be also included the necessary approval from Authority also.
SUBHEAD-14-- SITC OF LT MAIN PANEL IN THE SUBSTATION
SITC of floor mounted Indoor type extensible cubical MV switchboard,fabricated by CPRI approved panel maker having compartmentalized design, fabricated out of 14 SWG ( 2.0 mm ) nominal thickness CRCA sheet steel,front and back openable, hinged, single shuttered, with incoming ACBs & Outgoing MCBS and all accessories as per size, design & drawing to be approved by EIC and conforming to IS with latest modification and as per detail specification attached ( uploaded in the specification section) and following switches. I/C-630 A, ACB-2No. Bus Coupler-630A -1No O/G-415 volts,315 Amps, 4 Pole MCCB-1 Nos 415 volts,250 Amps, 415 volts, 4 Pole MCCB-4 Nos 415 volts,160Amps, 4 Pole MCCB- 5 Nos 63 Amps, 415 volts, 4 Pole MCCB - 2 Set
SUB HEAD 15 - HT/ LT CABLING IN SUBSTATION
Supplying and laying of 1 No. 11KV (E/UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable confirming to IS 7098, of earthed system of following size in the existing Masonary Open Duct as required.[ From Supplier HT Gear to Consumer HT Gear and to Transformer]. [ Make : Nicco / Gloster ]
a) 3 Core x 240 Sq.mm xlpe
Making heatshrinkable joints to the ends of the following XLPE HT cable at the transformer end as well as at the VCB ends supplying with necy. jointing kits, sockets, sleeves, anti-corrossive paste, wires, solders, jointing compounds, rubber sheets etc. incl. supplying of necy. tools & tackeles for crimping the end sockets, soldering irons & making of glands at the both end of the cable as per directions of EIC
b) 3 Core x 240 Sq.mm
Supplying and Laying of following size PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing Masonary Open Duct. [ From TR to main panel].[ Make : Nicco / Gloster
a) 4 Core x 300 sq.mm
Supplying and fixing compression type gland complete with brassgland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
a) 4 Core x 300sq.mm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
a) 4 Core x 300sq.mm.
Supply & Drawing 1.1 KV Grade 7 Core 1.5 sq.mm PVC Armoured Copper Cable from Transformer WT relay to VCB WT relay for Power & Control Supply as per direction of EIC
COPPER PLATE EARTHING
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode [FOR TRANSFORMER NEUTRAL AND DG SET EARTHING]
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S.
Supply & fixing earth busbar of galvanized (Hot dip) MS flat 65 mm x 8 mm on wall having clearence of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Insulating the 65 x 8 mm M.S. flat incl. S&F black heat shrink PVC sleeves etc. The PVC tube sleeve to be inserted on the GI flat and heat shrinked by heating apparatus by skilled technician carefully without damaging the PVC sleeve as per direction of the EIC (for transformer neutral earth bus bar).
Providing and fixing 25mm X 5mm copper strip in 40mm dia GI pipe from earth electrode includingS &F 40 mm dia GI Pipe with brass nut, bolt, spring, washer, excavation and re-filling etc as reqd.
Supply & fixing 75x45 X 4.4 mm "C" channel having length of 2 mtr. each channel incl. nuts, bolts and washer etc.
S & F special type earth electrode clamp made of GI flat with nuts, bolts,, washer etc. suitable for 80 mm dia GI pipe earth.
SUB HEAD - 16( SAFETY EQUIPMENT )
Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscription in signal red colour on front side as required.
a) High Voltage - size 250mm x 200mm
b) Medium Voltage - size 200mm x 150mm
Providing and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS 15222-2002 and cylinders fully charged of following capacity(4.5 Kg ) [Make - Fire Shield/ Ceasefire]
Supply and fixing of foam fire extinguishers conforming to IS 4989-2006, Portable type 9 lit capacity hanged on wall with bracket complete as required. [Make - Fire Shield/ Ceasefire]
Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required (approx. Front area 1.20 sq.mt.)
Providing of set of 4 nos. 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint 'FIRE' and mounted on MS angle iron frame with bracket and suitable base of appropriate size & capacity I/c filling sand etc.
Providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 13115-1991.
Supply and fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as reqd. (approximate front area 1.20 sq.metre).
Providing of rubber mat 2 mtrs Length x 1 m. wide and 12mm thick to withstand 15 KV dielectric strength as per IS 15652-2006.
Providing of rubber mat 2 mtrs Length x 1 m. wide and 6mm thick to with stand 3.3 KV dielectric strength as per IS 15652-2006.
S/F of 860 mm wide and 8 mm thick M.S checker plate including painting for covering the trench.
S&F 11kv grade Rubber Hand Gloves.
SUB HEAD 17- LT CABLING FROM SUBSTATION
Supply & Delivery 1.1 KV Grade XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size and conforming to IS: 7098(Part-I):1988/1554(Part-I):1988/ 5831:1984/ 3961(Part-I):1967/ 3975:1970/ 10810:1984/ 3975:1970 /8130:1984/ 3961:1967/ 10418:1982/10810:1984 as amended upto date, in respect of component materials and tests. [Nicco / Gloster/Polycab/Havells/RR Kable]
4 CX120 Sq. mm [ SUBSTATION TO Work Shop Qubical panel ]
4 CX 300 Sq. mm [ SUBSTATION TO DG ]
4 CX 95 Sq. mm
4 Core 70 Sq. mm
4Core 25 Sq. mm
4Core 10Sq. mm
Laying of cable on wall/surface incl. S & F MS saddles with earthing attachment in 2x10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
upto 3/4 core 25 sqmm
above 50 sqmm to 95 sqmm
above 90 sqmm and upto150 sqmm
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
(i) With out angle iron support
100x50x1.25mm (18SWG)
(ii) With 25x25x3mm angle iron support
200x50x1.25mm (18SWG)
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.
From 70sqmm to 150sqmm
Laying of the following cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Upto 4c x 35 sqmm
Above 4C x 35 sqmm and upto 4Cx185 Sq.mm
above 185 Sq.mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 core 300 sqmm cable
4 Core 120 Sq. mm
4 Core 70 Sq. mm
4Core 25 Sq. mm
4Core 10 Sq. mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
4 core 10 sqmm cable
4 core 25 sqmm cable
4 core 50 sqmm cable
4 core 70 sqmm cable
4 core 120 sqmm cable
4 core 300 sqmm cable
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
50mm dia
65mm dia
80mm dia
100mm dia
Sub-Head-18 SITC of AC Machines
Supply & Delivery of Hi-wall Split Air Conditioner having following specification. Cooling Capacity(KCal/Hr) - 6000 KCal/Hr or higher STAR Rating - Minimum BEE leveling-3 Star or more (2018) IS compliance - IS 1391 Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condensor Coil : Copper Operating Outdoor Temparature = 50ºC and above Power Supply - 230V,50Hz ( +Tolerrance as per applicable standard) [Make: Mitsubishi Electric / General /Toshiba]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including S&F of necessary fixing arrangement for indoor and outdoor unit, duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrial rubber insulation - 3 mtr (ii) necessary copper cable (FRLS type - make : Finolex/ Havells/Polycab/RR Kabel ) - 3mtr
Supply & Fixing of extra refrigerant copper pipe between the indoor and outdoor units of the split type AC unit etc as required with 12.5mm thick nitrile rubber insulation over it along with other accessories on wall.
Supply & Fixing of 25/26 mm dia. CPVC HD pipe extra as drain pipe for Split type AC/Cassette Type AC as required for condensed water.
Supply & Fixing AC starter unit 240v, 25 amp, overload protection (Make-Ultratech , OLP30)
Supply, fabrication & fixing 3 Nos, M.S. U-Channel of 6mm thick of size (100 mm x40mm x 40mm) of 1 mtr length for making platform for installation of outdoor unit of the Cassette type unit/Split Unit incl. drilling 2 nos holes in each channel including cutting holes the wall & grouting the same with Cement concrete (1: 11/2:3) etc. fabricated with horizontal angle of 50mm x 50mm x 6mm of 2mtr length including supporting angle 50mm x 50mm x 6mm in each platform in outer edge for transmitting the load centrally through 2 nos (50mm x 50mm x 6mm) angle inserted into the exiting wall. The platform should be baricated with verticle angle of 25 mm x 25mm x 6mm of 1 mtr. length fabricated on the surface of each horizontal channel & angles &interconnected by 25mm x 25mm x 5mm MS patti. Area of platform is 1m x 0.8 X0.5 Mtr.
Supply & Delivery of Ceiling Suspended Ductable type Split Airconditioners having Microprocessor Based Control System and the following specification
Capacity - 8.5 Tonnage (upto +1 TR acceptable)
Rated Cooling Capacity - 102000 BTU/Hr.
No of IDU - 1 No
Air-flow / IDU - 3400 CFM
No of ODU - 1 No.
Compressor - 1 No Scroll Compressor
Refrigerent - R 410A
Condenser & Cooling Coil : Copper coil
Power Supply : 415V, 50 Hz, 3 Ph AC (with applicable tolarance)
Make - Carrier/ Voltas/ Blue Star/ Mitsubishi Electric / Hitachi/ Trane/ YORK / DIAKIN
Installation Testing and Commissioning of 8.5 TR. Ceiling Suspended Ductable Split Air Conditioners by making scaffolding arrangement as per site condition, Supply of necessary Refrigerant, connecting Control & power cabling & other necessary materials to complete the job.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required
Supply, installation, testing and commissioning of GI Non-return damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications for stand by units
Supply, installation, testing and commissioning of Flexible Canvas Connection as per direction of the EIC.
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Package/VRV/VRF/RAC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal ( Make-Tata Steel/Sail/Jindal ) rectangular/ round ducting complete with neoprene rubber gaskets,elbows,splitter dampers, vanes, hangers, supports etc as per approved drawings and specifications of following sheet complete as required
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Duct tharmal insulation by supplying and fixing of 19mm thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
Supply, laying and termination of 1.1 kv grade following size PVC insulated PVC sheathed unarmoured Copper Cable (make:-Finolex/RR Kable/Polycab/Havells/Gloster)
3C X 4 SqMM
Supply & Fixing PVC drain Pipe 32 MM dia Make appd by EIC
Supply, installation, testing and commissioning of Flexible Canvas Connection as per direction of the EIC.
Supply, fabrication & fixing 3 Nos, M.S. U-Channel of 6mm thick of size (100 mm x40mm x 40mm) of 1 mtr length for making platform for installation of outdoor unit of the Cassette type unit/Split Unit incl. drilling 2 nos holes in each channel including cutting holes the wall & grouting the same with Cement concrete (1: 11/2:3) etc. fabricated with horizontal angle of 50mm x 50mm x 6mm of 2mtr length including supporting angle 50mm x 50mm x 6mm in each platform in outer edge for transmitting the load centrally through 2 nos (50mm x 50mm x 6mm) angle inserted into the exiting wall. The platform should be baricated with verticle angle of 25 mm x 25mm x 6mm of 1 mtr. length fabricated on the surface of each horizontal channel & angles &interconnected by 25mm x 25mm x 5mm MS patti. Area of platform is 3Mtr x 1Mtr.
Fabrication work , supply installation, testing & commisining of ducting complete with splitter dampers , turning vanes insulation supports etc.
SITC of Al powder coated diffuser
Terms and condition
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
CHAKRABORTY ENTERPRISE
M/S SUPARNA ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .