Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC | L1 | Accepted-AOC DUE TO LOWEST BID | |
| 2 | L2₹47.3 L+₹7.0 L (17.3%)Rejected-Finance | L2 | Rejected-Finance DUE TO HIGHER BID | |
| 3 | L3₹48.7 L+₹8.3 L (20.7%)Rejected-Finance | L3 | Rejected-Finance DUE TO HIGHER BID | |
| 4 | L4₹49.4 L+₹9.0 L (22.3%)Rejected-Finance | L4 | Rejected-Finance DUE TO HIGHER BID | |
| 5 | L5₹49.7 L+₹9.3 L (23.1%)Rejected-Finance | L5 | Rejected-Finance DUE TO HIGHER BID |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
31 Aug 2022, 6:00 pmClosed
GE WEST FEROZEPUR CANTT
GE WEST FEROZEPUR CANTT
SPECIAL REPAIR TO SEWAGE LINE AND MAIN HOLE CHAMBER AT UNIT LOCATION OF Q AND Q ZONE OF 3 GR UNDER AGE BR II OF GE WEST FEROZEPUR CANTT
2022_MES_536693_2
802022/GE-56/E8
Open Tender
Civil Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST FEROZEPUR CANTT
₹96,000
Yes
15 Sept 2022
19 Aug 2022
2 Sept 2022
19 Aug 2022
31 Aug 2022
26 Aug 2022
Amount
Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in soft/loose soil complete all as specified.
Earth work in excavation for all kind of soil by mechanical means(Hydraulic excavator) in foundation trenches or drain (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out excavated soil and disposal of surplus excaveted soil as directed, within a lead of 50m as directed by Engineer-in-charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and exc 1.5 metre but not exceeding 3 metre depth and not exc 10 Sqm on plan, for shafts, wells, cesspits, manholes, pier holes, etc and getting out,compete all as specified.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and exc 3 metre but not exceeding 4.5 metre depth and not exc 10 Sqm on plan, for laying of cable and getting out,compete all as specified.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge .
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas including getting out and disposal of excavated earth lead upto 50 m and lift exc 1.5 metre but not exceeding 3 metre, as directed by Engineer-incharge .
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas including getting out and disposal of excavated earth lead upto 50 m and lift exc 3 metre but not exceeding 4.5 metre, as directed by Engineer-incharge .
Returning, filling in, including spreading, leveling, watering and well ramming soft/loose soil in layers n. exc 25 cm thickness
Removing excavated soil n exc 50 m and depositing where directed at a level n exc 1.50 m above the starting point
Demolition and breaking up salt glazed stoneware (SGSW) drain pipes set in cement mortar internal dia of pipe 200 mm.
Demolition and breaking up salt glazed stoneware (SGSW) drain pipes set in cement mortar internal dia of pipe 150 mm.
M & L cement concrete 1:3:6 type C2 as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid & tested for 250 mm bore pipe
M & L cement concrete 1:3:6 type C2 as in bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested for 250 mm bore pipe complete all as specified.
M & L cement concrete 1:3:6 type C2 as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid & tested for 150 mm bore pipe complete all as specified.
M & L cement concrete 1:3:6 type C2 as in bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested for 150 mm bore pipe complete all as specified.
M & L 250 mm dia reinforced concrete pipes,class NP2 laid and jointed complete with collars in trenches as specified
All as peer ser item No 16 above but 150 mm bore pipe.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for & forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished and reforming branching as required for 150 mm dia pipes
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for & forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished and reforming branching as required for 250 mm dia pipes
Rendering/plastering, 15mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces,, surfaces finished even and smooth without using extra cement complete all as specified.
Demolition of PCC of any description and in any position as in not otherwise specifically provided for
Cement concrete (1:4:8) type D2 40mm graded agg in foundations, filling and mass concrete complete all as specified and directed
M&L for cement concrete type B2 1:2:4 (40mm graded aggregate) in surface channels and drains complete all as specified and directed
Providing cement concrete 1:2:4 type B1 (20mm graded agg) in win- dow or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, ier aps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces,including chamfers, weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match complete all as specified.
Dismantling of 100mm cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required. complete all as specified and directed
S&F cast iron soil, waste and vent pipes of 100 mm bore in any length with or without ears with cement joints fixed to wall complete all as specified and directed.
All as per ser item No 26 above but fixing only
S&F CI bends of 100 mm bore diminishing pieces or tapers including jointing with CM 1:3 and making good complete all as specified.
S&F 100mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches.
S&F cast iron soil, waste and vent pipes of 75 mm bore in any length with or without ears with cement joints fixed to wall complete all as specified.
All as per ser item No 30 but fixing only
S&F CI bends of 75 mm bore diminishing pieces or tapers including jointing with CM 1:3 and making good complete all as specified.
S&F 75mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches
Demolition of brick work built in cement mortar of any specification and in any position complete all as specified.
Brick work in cement mortar 1:6 using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6 metre mean radius complete all as specified.
All as per ser item No 35 but except bricks.
M/L RCC 1:2:4 type B1 using 20mm graded aggregate as in Precast cover slab , shelves and similar articles and setting in mortarcomplete with joints to match complete all as specified
S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified.
Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floor topping, 75 mm thick, complete all as specified.
Cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in floor topping, 100 mm thick, surface finished even and smooth without using extra cement complete all as specified.
M&L for cleaning of blockage IWCs / EWC, bathroom / kitchen by cleaning the nahani traps / gully traps and CI / PVC pipe line upto the 1st Manhole. All the mud / sludge / Kitchen waste / plants roots to be cut/ removed and getting out by washing the traps, CI waste pipe throughly by opening the cleaning eyes lids properly . The sludge/ waste received during cleaning process to be removed at a distance not exceeding 100m from the bldg and Bleaching powder to be spread over waste and burred under the Soil / Earth . Earth work shall be included in the unit rate.
Cleaning and desludging / de-watering of septic tanks /Manholes and soakage well of any depth by using honey sucker followed by mechanical roding followed by hydraulic jet pressure machine etc as required,with the entire satisfaction of Engr -in- charge and re-fixing the manholes cover to its original position complete all as specified and directed.
M/s Manoj Construction Co.
CHETAK CONSTRUCTION COMPANY
JAWAHAR CONSTRUCTION COMPANY
KAMALJIT SINGH CONTRACTOR
M/s Bansi Lal
M/S CHAWLA CONSTRUCTION COMPANY
KAILASH CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .