RequiredOEM Authorization Certificate Bid to RA enabled Yes Portable Ultrasound Machine ( 3 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Product certification Both EU CE (With verified number) and US FDA * Certification number and date - * Confirmity to Manufacturer's Certification ISO 9001 & ISO 13485 * Confirmity to Performance and safety IEC 60601-2-37 or equivalent BIS * 1/6 standards specific to the device Performance Parameters Product Description Portable ultrasound scanners are commonly used for a wide range of point-of-care ultrasound (POCUS) applications. POCUS refers to the use of ultrasound by the treating physician or other care giver as opposed to the treating physician referring the patient to an ultrasound specialist. Unlike the comprehensive examinations performed by imaging professionals in radiology or cardiology settings
RequiredPOCUS exams are typically performed to answer specific clinical questions. The use of ultrasound in the emergency department (ED) is a typical example of POCUS. * UMDNS Code and names(Hint: This is for indicating the relevant universal medical devices nomenclature for the category of prouct ) Scanning Systems
RequiredUltrasonic
RequiredPortable ( 18-143) * Scope of supply Portable ultrasonic scanning systems provide two- dimensional (2-D) B- mode images of soft tissues without subjecting patients to ionizing radiation. It intends to primarily for abdominal
Requiredobstetric/gynecologic (OB/GYN)
Requiredsmall-parts
Requiredand vascular imaging * Types of Probes & Features Applications- Abdomen
Requiredabdominal vascular
Requiredurology
RequiredOB/GYN
Requiredneonatal brain
Requiredsmall parts (breast
Requiredthyroid
RequiredYes * 2/6 scrotal
Requiredprostate
RequiredMSK) Flat linear array 5-10 MHz (±2) * Convex array 2.5-5 MHz (±2) * Frequency Range of FOV TV 1-15 MHz * Scanning Depth ≥30cm * Scan Modes Dual Imaging Yes * Power Doppler Yes * Directional Power Doppler Yes * PW Yes * Sample Volume 0.5-20 mm * HPRF Yes * Digital Beam Forming Yes * B-steer Yes * THI Yes * Duplex Yes * Autotrace & Measurement Yes * Gray Scale 256 * Dynamic Range 20~280 dB * Gain 0~255 * IMAGE DISPLAY AND PROCESSING Monitor Type LCD LCD Monitor Size
Requiredinch 10 to 12 10 to 12 Backlit Keyboard Yes * Adjustable transmit focus Yes * Grayscale levels 256 * Image magnification (zoom) Yes * Real-time image Yes * Frozen image Yes * Transducer Socket 1 1
Required2 Flash Memory Yes * USB connector Yes * "Facility for high definition digital acquisition
Requiredreview and editing of complete patient studies" Yes * Digital storage hard ≥500 GB * 3/6 drive size WEIGHT
Requiredkg (lb) without trolley 3.4 * Type of processor i7 or latest * Power Requirements Power input
RequiredVAC 220-240VAC
Required50Hz fitted with Indian plug * Power backup Inbuilt battery Inbuilt battery Back up time in minutes 120 120 Miscellaneous Parameters Warranty in years 5 5 Number of installations of the Portable USG machines in Central State/PSU Govt Hospitals( Note: Seller should supply a performace certificate of the device to the buyer if demanded after placement of order) More than 3 More than 3 User/Technical/Mainten ance manuals to be supplied in English in hard and soft copy Yes * Demonstration of equipment and training to be provided after completing supplies & Installation before acceptance Yes * The Principal Manufacturer must have direct Presence/approved service center In India Yes * Copies of reports and certifications to be furnished to buyer on demand at time of supplies Yes * Certificate from the principal that spare parts will be available for next 10 years shall be provided at the time of supplies Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. 4/6