Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC AT PO DAKRA DISTT RANCHI JHARKHAND 829210 | RANCHI | JHARKHAND | 829210 | L1 | Accepted-AOC The L1 bidder is techno-commercially qualified. The quoted rate has been accepted by the Competent Authority, NK Area. | |
| 2 | L2₹7.1 L+₹47,767 (7.22%)Rejected-Finance 00 C O LAKHAN LAL AGRAWAL RATU ROAD NEAR KABLISTHAN RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical AT PO DAKRA KHALARI DIST RANCHI JHARKHAND PIN 829210 | RANCHI | JHARKHAND | 829210 | - | Rejected-Technical Technically disqualified. |
Tender Value
₹7.1 L
EMD Value
₹8,900
Closing Date
9 May 2025, 5:00 pmClosed
SO EnM NK
GM OFFICE, NK AREA
Rearrangement and maintenance of 11kV Overhead line from KDH Old Substation to Rohini Substation to ensure uninterrupted 11kV power supply during monsoon under Rohini OCP, NK Area
2025_CCL_334669_1
GM (NK)/EnM/e-NIT/2025-26/25
Open Tender
Electrical and Maintenance Works
Item Rate
21 days
Rohini OCP, NK Area
As per NIT
2 documents required · 2 mandatory
₹8,900
8 Jun 2025
28 Apr 2025
10 May 2025
29 Apr 2025
9 May 2025
29 Apr 2025
29 Apr 2025 - 5 May 2025
Amount
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required. Above 8.00 Metre and upto 10.00 Metre.
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required. Above 10.00 Metre and upto 12.00 Metre.
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc as required.
Supplying and erection of stay set complete (galvanized) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supply of Clamps, bolts, nuts etc.
Erection of double pole 3 wire cross arm for 11KV over head lines as required
Erection of disc / pin insulator for 11 KV over head lines as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 33 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required
Supply 6 SWG G.I wire
Erection of G.I. Wire No. 8 SWG including binding etc. as required
Dismantling of pole / street light standard / strut embedded in cement concrete foundation etc as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
Erection of cradle guard as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Dismantling of over head lines comprising of copper / aluminium over head conductor, G.I. wire, cross arms, insulators etc as required
Tree trimming / Branch cutting under Overhead lines.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
Total impact of GST for the purpose of CTC
M/S PRAVEEN KUMAR (BID ID -1151485)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .