| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.4 L+₹29,835 (1.85%)Rejected-AOC KTA ROAD LAMBA LINE JUNGLIGHAT PO PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-AOC L2 | |
| 3 | L3₹17.4 L+₹1.4 L (8.40%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹17.6 L+₹1.5 L (9.26%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹18.8 L+₹2.7 L (16.6%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
20 Jul 2020, 6:00 pmClosed
GE (I) CAMBELL BAY
GE (I) CAMBELL BAY
REPAIRS AND REPLACEMENT OF INTERNAL WIRING AND LED FITTINGS AND MAINTENANCE OF SUMMER APPLIANCES AND MISCELLANEOUS EM SERVICES AT ARMY LAND UNDER GE (I) CAMBELL BAY
2020_MES_348302_2
8680/E8
Open Tender
Civil Works
Item Rate
180 days
CAMBELL BAY
As per NIT
8 documents required · 8 mandatory
₹500
GE (I) CAMBELL BAY
₹32,000
Yes
6 Aug 2020
3 Jul 2020
22 Jul 2020
5 Jul 2020
20 Jul 2020
8 Jul 2020
Amount
Taking down old unserviceable point wiring, (light, fan, socket or power) complete including all fittings & fixtures such as switch, ceiling rose, pendants, regulator, socket, etc., and making good the disturbed surface of wall, floors, ceiling etc to match with the existing including touch up of paint/white wash all as specified and directed by Engineer- in-charge.
Material and labour for point wiring with 1.5 sqmm PVC insulated,unsheathed FRLS multistrand copper conductor cable 1100 votls grade drawn into and including non metallic rigid PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour/ casing Caping as per site requirement with all conduit fittings and fixing accessories including 2.0 mm thick MS sheet terminal boxes (2 Coats of black paint over one coat of red oxide) with 3.0 mm thick phenolic laminated sheet for mounting switches, sockets, fan regulators etc including 1.5Sqmm FRLS multistrand copper conductor cable as continuous earth wire complete for One light point controlled by one switch complete all as specified and directed
Ditto All as per Item No. 2 but for One fan point controlled by one switch.
Ditto All as per Item No. 2 but for One socket 5 Amps on same board.
Ditto All as per Item No. 2 but for One socket 5 Amps on independent board.
Ditto All as per item No. 2 but for point wiring with 2.5 Sqmm cable for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
Supply & Fix Switch piano, flush type, single pole, one way, 5 Amp complete all as specified and directed.
Supply & Fix Switch socket combination 2 in 1, 5 Amps, flush type complete all as specified and directed.
Supply & Fix Switch Socket combination 2 in 1, 3 pin, 5 and 15 Amp, flush type, universal complete all as specified and directed.
Supply & Fix Stepped type electronic fan regulator with 5 steps, flush type complete all as specified and directed.
Supply & Fix Ceiling rose PVC/ Polycarbonate insulated body with three terminals complete all as specified and directed.
Supply & Fix Surface mounting 10 Watt LED Luminaries with epoxy white powder coated CRCA sheet steel housing with reeded translucent acrylic diffuser and 1 x 10 Watt LED fitting including taking down old unserviceable fittings of any type complete all as specified and as directed . Make : CG, Bajaj, Wipro or Equivalent
Supply and fix surface mounting 20Watt LED Tube light fitting, nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W, the luminaire shall have a rated system lifetime of 50,000 burning hours at L70, the luminaire should have a color temperature of 6500K and CRI>83, pre wired connection up to tube light fitting with connecting up with copper 2 core flexible cord of minimum size 1.0 Sqmm and white in colour and the luminaire shall meet IP20 rating with THD < 10% and PF > 0.95, the total power consumption should not exceed 20Watt (including driver) including taking down old unserviceable fittings of any type including round block complete all as specified and as directed. Make : Phillips/Havells/WIPRO or Equivalent
Material and labour for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 2x4.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 4.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire including taking out old wire complete as directed by Engineer in Charge.
Material and labour for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 2x6.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 6.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire including taking out old wire complete as directed by Engineer in Charge.
Material and Labour for cutting chases for concealed conduit point wiring,sub main wiring and sinkings for boxes but not exeeding 10 cm girth and making good to walls,floors with cement mortar 1:3 and apply white wash or distemper matching with existing colour as directed by Engineer in Charge.
Supply & Fix Sheet metal enclosure for DB SPN, double door 240V, 4 way with 200 Amps rated bus bar complete as directed by Engineer in Charge. Make -Legrand/L&T/Havells or Equivalent
Supply & Fix Sheet metal enclosure for DB SPN, double door 240V, 8 way with 200 Amps rated bus bar complete as directed by Engineer in Charge. Make -Legrand/L&T/Havells or Equivalent
Supply & Fix Sheet metal enclosure for DB TPN, double door 240V, 4 way with 200 Amps rated bus bar complete as directed by Engineer in Charge. Make -Legrand/L&T/Havells or Equivalent
Supply & Fix MCB SP 6 to 32 Amps 10 KA, "C" Series complete as directed by Engineer in Charge. Make -Legrand/L&T/Havells or Equivalent
Supply & Fix MCB DP 32 Amps 10 KA, "C" Series complete as directed by Engineer in Charge. Make -Legrand/L&T/Havells or Equivalent
Supply & Fix MCB TPN 40 to 63 Amps 10 KA, "C" Series complete as directed by Engineer in Charge. Make -Legrand/L&T/Havells or Equivalent
Taking down of unserviceable PCB (permanent circuit board) and providing new PCB for AC of 1.5 / 2.0 Ton capacity complete as directed by Engineer in Charge.
Taking out of unserviceable swing motor and providing new swing motor of same quality and charecteristics suitable for any make of AC 1.5/2.0 Ton split/window type complete as directed by Engineer in Charge.
Material & Labour for shifting of split ACs of capacity 1.5/2 Ton alongwith all accessories to new location and fixing, testing complete all as directed. Note :- Gas charging, if required shall be paid separately under relevant items.
Dismantling old and providing new copper tubes of size 1/4 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
Dismantling old and providing new copper tubes of size 1/2 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
Dismantling old and providing new copper tubes of size 3/8 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
Dismantling old and providing new copper tubes of size 5/8 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
Taking out unserviceable MCCBs of any size and any description from the feeder pillar boxes and Supply and fix Moulded Case Circuit Breaker (MCCB) four pole, 415 Volts of capacity 63Amps with thermal magnetic release with breaking capacity 16KA complete all as specified and directed.
Taking out unserviceable MCCBs of any size and any description from the feeder pillar boxes and Supply and fix Moulded Case Circuit Breaker (MCCB) four pole 415 Volts of capacity 100Amps with thermal magnetic release with breaking capacity 25KA complete all as specified and directed. Make -Legrand/L&T/Havells oe Equivalent Note: Makes of MCCBs are as per site requirement for Item No. 28 &29.
Taking down the ceiling fans/Exhaust fans of any sweep carefully from its original position and refixing the same after carried out the repairs/rewinding and painting complete as directed by Engineer in Charge.
Dismantling motor of Ceiling Fan/Exhaust fan of any sweep and over hauling complete by cleaning all dust/grease with kerosene or petrol,replacement of unserviceable bearings, bushes,split pins and nut and bolts and applying new grease for bearings, reassembling the motor and fixing the blades and testing complete as directed by Engineer in Charge. Note: Items required for repair such as Bearings, bushes shall be measured and paid separately under respective items.
Supply only ball bearing for Ceiling Fan/Exhaust fan.
Supply only GM bush for Ceiling Fan/Exhaust fan.
Supply and Fix capacitor 2.5 MFD for Ceiling Fan complete all as specified and directed.
Supply and Fix capacitor 4.0 MFD for Exhaust fans of size upto 450mm sweep complete all as specified and directed.
Supply and Fix MS clamp with rubber bush suitable for hanging for Ceiling fans complete all as specified and directed.
Material and labour for preparation old surfaces of Ceiling fan and Exhaust fan of any sweep and painting the with one coat of synthetic enamelled paint by spraying including filling all cavities with filler as directed by Engineer in Charge.
Material & Labour for dismantling the motor of ceiling Fans of 1200mm/1400mm Sweep by unscrewing, removing stator, rotor, bearings separately without damaging any parts, rewinding the same with fine quality of super enamelled copper winding wire of suitable size & Capacity including, varnishing, drying etc., and refixing the stator and rotor perfectly to rotate smoothly and connection complete including taking out burned unserviceable copper winding wire complete all as as directed by Engineer in Charge.
Ditto All as per item No.40 above but for Exhaust fans upto 380 mm sweep.
Disconnect and remove unserviceable thermostat and supply and fix thermostat suitable for existing window/split type air conditioner of capacity 1.5 TR complete all as specified and directed.
Disconnect and remove unserviceable starting capacitor and supply and fix starting capacitor 100/120 MFD suitable for window/split type air conditioner of capacity 1.5TR complete all as specified and directed.
Disconnect and remove unserviceable running capacitor and supply and fix running capacitor 36 MFD suitable for window/ split type air conditioner of capacity 1.5 TR complete all as specified and directed.
Disconnect and remove unserviceable compressor and supply and fix sealed compressor including bracing the suction/discharge line suitable for existing window/split type air conditioner of capacity 1.5TR and testing on completion complete all as specified and directed. Make: - Tecumesh/copland/Kirloskar.
Disconnect and remove unserviceable condenser and supply and fix condenser including bracing the suction/discharge line suitable for existing window/split air conditioner of capacity 1.5TR and testing on completion, complete all as specified and directed. Make: - Opel/Accent/Skoda.
Material & labour for filling up & charging of R-22/R-32/R-134A/R-410 refrigerant or any type of gas as per site requirement for window/spilt type air conditioner of capacity 1.5TR, refrigerator and water cooler of capacity 80/40 litres after leak testing of complete system and making good by bracing complete all as specified and directed.
Removing the defective fan motor of window/split AC 1.5 TR and Supply and fix fan motor with blade including all connection and testing complete all as specified and directed.
Taking out unserviceable heating element of any description from geyser and supply and fix new heating element of 1500 watts in its original position and testing complete as directed by Engineer in charge
Taking out unserviceable thermostat of any description from geyser and supply and fix new themostat in its original position and testing complete as directed by Engineer in charge
Dismantling and Taking out old unserviceable post lamp fittings and Supply & Fix integral 40 Watt LED post top lanterns with black ABS plastic spigot spun aluminium canopy, with opal acrylic difuser and accessories integral,Fedora hat post top lantern with clear acrylic complete as directed by Engineer in charge Make : CG, Phillips, GE or Equivalent.
Supply fixing 60Watt LED street light/building security light with pressure die cast aluminum housing & toughened glass with IP-66 degree of protection, Individual LED's must have pea nut lenses for better throw across & along the road, with luminaire efficiency of greater than 85 Lumen/Watt (Minimum lumen output of luminaire should be 3800Lumens), color rendering (CRI) of ≥ 75 and co-related colour temperature (CCT ) of 5700K (± 500K), The luminaire should have 5KV surge protection, PF ≥ 0.95, and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V should be provided, Luminaire should have top maintainable driver compartment for easy access to driver during maintenance, The Driver used must be a constant current driver with efficiency of ≥ 85%, The manufacturers LOGO must be Embossed/ Engraved in the housing of the luminaire with and including bracket for street light fittings made out of 40 mm dia GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 40x5 mm flat iron including GI Nuts, bolts and washers and painting of clamps complete all as specified and directed Make : CG LSTP-60-CDL-M or equivalent in Wipro and Philips.
Taking out the existing fittings of any type on ceilings and Supply & Fix 36 Watt LED Luminaire suitable for 600x600mm modular ceiling grid including frame of suitable size for LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 5000 total lumen, The 36 Watt system shall be operating at 220-240V AC supply having internal driver, IP20,surge protection 2KV ,ambient temperature 20 to 45 degree C, frequency of 50 to 60 Hz, The system efficiency must be between 80-100 lumen/watt, with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread, CRI minimum 80, PF should be greater than 0.95, THD < 10%, Indivisual LED's should not be visible for glare free output, colour temperature 6500k complete all as specified and as directed. Make :CG, Phillips, GE or Equivalent.
Supply & Fix Energy saving ceiling fan of 1200 mm sweep with double ball bearing in opal white color and BEE 5 star rated complete including provision of 3 core copper wire of size 1.5 sqmm , connected from ceiling rose to fan and marking MES No in black paint complete all as specified and as directed. Make:- BAJAJ Model No 250487 grace LX 1200 MM WHITE or equivalent.
Dismantling and taking out old unserviceable Earthing and Material & Labour for earthing with galvanised steel earth plate electrode 60cmX60cmX6mm burried earth pit not less than 2.25m depth below normal ground level with to edge of the plate vertically to depth of not less than 1.5 m below ground level connected to & including Galvanised earth wire 4.0mm dia by mean of GI bolts & nuts etc with provision of charcoal and salt etc, all as per electrical plate No-3 of SSR-2010 including RCC cover and MS angle iron frame, watering with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc. complete all as specified and directed by Engineer-in-charge. Note : 1. Refilling of the earth pit shall be carried out with black cotton soil. 2. GI wire 4.0mm dia & GI protection pipe upto 7.5 m length will be measured under this item.
Material & Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required 4.0 mm galvanised iron wire complete including taking down existing old GI wire complete all as specified and directed by Engineer In Charge
An Amount of Rs. 20,083/- towards Schedule of Credit shall be deducted to arrive the Contract Sum.
kakolil trade agencies
RSL Construction
bansal construction
M/s Kamal Electrical
V CHINNA DURAI
Tropical Refrigeration
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .